ETC1 D205RP Short circuit protected regulated, 2w sip dc/dc converter Datasheet

D200RP Series
Short Circuit Protected
Regulated, 2W SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
● 2W Output Power
● Short Circuit Protection
● Tight Line/Load Regulation
● 1,000 VDC Isolation
● Miniature SIP Case
● >1.5 MHour MTBF
● 15 Standard Models
Parameter
Conditions
5 VDC Input
Input Voltage Range
Min.
Typ.
Max.
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
24 VDC Input
21.6
24.0
26.4
Input Filter
Units
VDC
π (Pi) Filter
Reverse Polarity Input Current
0.3
A
Max.
Units
±2.0
%
±0.5
%
Output
Parameter
Conditions
Min.
Typ.
Output Voltage Accuracy
Line Regulation
For Vin Min to Max
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Output Power Protection
±0.5
%
75
mV P - P
±0.02
%/ºC
Max.
Units
120
%
Temperature Coefficient
Output Short Circuit
Continuous
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,000
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
VDC
MΩ
60
pF
40
kHz
Environmental
Parameter
Min.
Typ.
Max.
Units
Operating Temperature Range
Conditions
Ambient
-25
+25
+71
ºC
Operating Temperature Range
Case
-25
+85
ºC
-40
+125
ºC
95
%
Storage Temperature Range
Cooling
Humidity
MicroPower Direct
Free Air Convection
RH, Non-condensing
Physical
232 Tosca Drive
Stoughton, MA 02072
USA
Case Size
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Reliability Specifications
1.26 x 0.32 x 0.55 Inches (32.0 x 8.0 x 14.0 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
Parameter
MTBF
0.17 Oz (4.8g)
Conditions
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
1.5
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Min.
5 VDC Input
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
-0.7
Typ.
Max.
Units
9.0
12 VDC Input
-0.7
18.0
24 VDC Input
-0.7
30.0
VDC
1.5 mm From Case For 10 Sec
260
ºC
All Models
450
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D201RP
D202RP
D203RP
D204RP
D205RP
D211RP
D212RP
D213RP
D214RP
D215RP
D221RP
D222RP
D223RP
D224RP
D225RP
Notes:
Input
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
5
4.5 - 5.5
606
80
5
4.5 - 5.5
606
80
5
4.5 - 5.5
571
80
5
4.5 - 5.5
571
80
5
4.5 - 5.5
588
80
12
10.8 - 13.2
253
45
12
10.8 - 13.2
253
45
12
10.8 - 13.2
238
45
12
10.8 - 13.2
238
45
12
10.8 - 13.2
246
45
24
21.6 - 26.4
130
25
24
21.6 - 26.4
130
25
24
21.6 - 26.4
122
25
24
21.6 - 26.4
122
25
24
21.6 - 26.4
118
25
1. Output load regulation is specified for a load change
of 20% to 100%.
2. When measuring output ripple, it is recommended
that an external 0.33 μF ceramic capacitor be placed
from the +Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units.
However, they may not meet all specifications.
4. These do not require external components to operate,
but the use of a low ESR capacitor (approximately
10 uF, ESR <1.0Ω at 100 kHz) mounted close to the
converter input pins is recommended.
5. It is recommended that a fuse be used on the input of
a power supply for protection. See the table above for
the correct rating.
Capacitive
Load
Voltage
(VDC)
5.0
9.0
12.0
15.0
24.0
5.0
9.0
12.0
15.0
24.0
5.0
9.0
12.0
15.0
24.0
Output
Current
(mA, Max)
400.0
222.0
167.0
133.0
83.0
400.0
222.0
167.0
133.0
83.0
400.0
222.0
167.0
133.0
83.0
Current
(mA, Min)
40.0
22.0
17.0
13.0
10.0
40.0
22.0
17.0
13.0
10.0
40.0
22.0
17.0
13.0
10.0
Efficiency
(%, Typ)
66
66
70
70
68
66
66
70
70
68
64
64
68
68
70
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
200
200
200
200
200
Derating Curve
Pin Connections
μF Max
470
Pin
Function
1
+Vin
2
NC
3
NC
9
NC
10
-Vout
11
+Vout
12
-Vin
Mechanical Dimensions
NC: No Connection
Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.01 (±0.25)
Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
■
TEL: (781) 344-8226
■
FAX: (781) 344-8481
■
E-Mail: [email protected]