INNOVATION SOLUTIONS SUPPORT RELIABILITY • Lifetime Warranty • UL508 approved • SEMI F47 Compliant (high line AC) • Universal Input (85 - 265VAC) • High Efficiency • RoHS Compliant Design Key Market Segments & Applications Factory Automation HWS Series Single Output Industrial Power Supplies Test & Measurement Automated Service Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots Burn-in & Test, Automated Test, Instrumentation, Measurement, Detection HWS Features and Benefits Features Benefits • Lifetime Warranty • High Efficiency • Wide Range AC Input • Lower Cost of Ownership • Easier System Cooling • Supports Global Use Specifications MODELS ITEMS Input Voltage range Input Current (Typ) (1) Inrush Current 100/200VAC Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense Indicator Operating Temp. (no cover) Storage Temperature Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Line Dip Conducted & Radiated Immunity Weight (Typ) Size (WxHxD) Warranty Notes: HWS15 A A V ms mA EMI g mm HWS30 HWS50 HWS100 HWS150 85 - 265VAC (47 - 63Hz) or 120 - 370VDC 0.4 / 0.2 0.8 / 0.4 0.7 / 0.35 1.3 / 0.65 1.9 / 0.95 14 / 28 Meets EN61000-3-2 <0.02%/oC >104% Yes (See page 2) 20 <0.5mA (Typ 0.3mA at 100VAC, 0.5mA at 230VAC) No Yes Green LED = ON -10C to +70C, derate linearly to 20% load from 50C to 70C -30 to +85C Operating: 30 - 90%RH, Non operating 10 - 95%RH Convection Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. >100M at 25C & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1m/s2 -UL60950-1, CSA60950-1, EN60950-1, EN50178, Built to meet UL508 CE Mark Complies with SEMI F47 (200VAC line only) EN55011 / EN55022-B, FCC-B, VCCI-B IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 4), -5(Level 3,4), -6(Level 3), -8(Level4, -11 180 220 280 450 500 26.5x82x80 26.5x82x95 26.5x82x120 28x82x160 37x82x160 Lifetime Warranty (See Lambda’s terms & conditions) (1) 100/200VAC See website for HWS/ME medical EN/UL60601-1 approved models and HWS/HD heavy duty / harsh environment models with -40 degree C startup HWS SERIES 1 Model Selector Model HWS15-3/A HWS30-3/A HWS50-3/A HWS100-3/A HWS150-3/A HWS15-5/A HWS30-5/A HWS50-5/A HWS100-5/A HWS150-5/A HWS15-12/A HWS30-12/A HWS50-12/A HWS100-12/A HWS150-12/A HWS15-15/A HWS30-15/A HWS50-15/A HWS100-15/A HWS150-15/A 1.2m/s Forced Air HWS15-24/A HWS30-24/A HWS50-24/A HWS100-24/A HWS150-24/A HWS15-48/A HWS30-48/A HWS50-48/A HWS100-48/A HWS150-48/A Voltage Adjust Range Max Curr. A Load Reg mV 3.3V 3.3V 3.3V 3.3V 3.3V 5V 5V 5V 5V 5V 12V 12V 12V 12V 12V 15V 15V 15V 15V 15V 24V 24V 24V 24V 24V 48V 48V 48V 48V 48V 2.97 - 3.96 2.97 - 3.96 2.97 - 3.96 2.97 - 3.96 2.97 - 3.96 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 50°C 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 3 6 10 20 30 3 6 10 20 30 1.3 2.5 4.3 8.5 13 1 2 3.5 7 10 55°C 0.65 1.3 2.2 4.5 6.5 0.33 0.65 1.1 2.1 3.3 40 40 40 40 40 40 40 40 40 40 96 96 96 96 96 120 120 120 120 120 192 192 192 192 192 384 384 384 384 384 Line Reg mV 20 20 20 20 20 20 20 20 20 20 48 48 48 48 48 60 60 60 60 60 60°C 96 96 96 96 96 192 192 192 192 192 Ripple Noise mV Over voltage V 120 120 120 120 120 120 120 120 120 120 150 150 150 150 150 150 150 150 150 150 200 200 200 200 200 200 200 200 200 200 4.13-4.95 4.13-4.95 4.13-4.95 4.13-4.95 4.13-4.95 6.25-7.25 6.25-7.25 6.25-7.25 6.25-7.25 6.25-7.25 15-17.4 15-17.4 15-17.4 15-17.4 15-17.4 18.8-21.8 18.8-21.8 18.8-21.8 18.8-21.8 18.8-21.8 65°C 30-34.8 30-34.8 30-34.8 30-34.8 30-34.8 55.2-64.8 55.2-64.8 55.2-64.8 55.2-64.8 55.2-64.8 Eff. typ % 100/200 VAC 68/71 70/73 76/78 78/81 78/81 77/79 77/80 82/83 83/86 83/86 80/81 81/83 81/83 83/86 83/86 80/81 81/83 81/83 83/86 83/86 70°C 82/83 83/86 82/84 84/87 85/88 80/80 82/83 83/85 84/87 85/88 Options Suffix Description Blank /A /R Screw terminals, no cover Screw terminals, cover Remote on/off (50-150W only) Example: HWS50-24/RA Full size drawings and more information available at www.lambda-europe.com/hws HWS15 Outline Drawing 2 HWS SERIES HWS30 Outline Drawing HWS50 Outline Drawing HWS100 Outline Drawing HWS150 Outline Drawing Note: All fixing holes M3 tapped max. depth 6mm HWS SERIES 3 LAMBDA EUROPE AUSTRIA LAMBDA ELECTRONICS GmbH Aredstraße 22 A-2544 Leobersdorf Telephone: Facsimile: +43 (0) 2256 655 84 +43 (0) 2256 645 12 www.lambda-austria.com FRANCE LAMBDA SAS ZAC des Delaches, BP1077 - Gometz le Chatel 91940 Les Ulis Telephone: Facsimile: Web: +33 (0) 1 60 12 71 65 +33 (0) 1 60 12 71 66 www.lambda-f.com GERMANY LAMBDA GmbH Karl-Bold-Straße 40 D-77855 Achern Telephone: Facsimile: Web: +49 (0) 78 41 666 0 +49 (0) 78 41 5000 www.lambda-germany.com ISRAEL NEMIC LAMBDA LTD Kibbutz Givat Hashlosha 48800 Telephone: Facsimile: Web: +972 (0) 3 902 4333 +972 (0) 3 902 4777 www.nemic.co.il ITALY LAMBDA s.r.l. Via dei Lavoratori 128/130, 20092, Cinisello Balsamo (Mi) Telephone: Facsimile: Web: +39 (0) 02 61 29 38 63 +39 (0) 02 61 29 09 00 www.lambda-italy.com SWEDEN LAMBDA SCANDINAVIA PO Box 546, Rallarvägen 41 SE-184 25. Akersberga Telephone: Facsimile: Web: +46 (0) 8 598 94 090 +46 (0) 8 540 66 096 www.lambda-scandinavia.com UK LAMBDA UK Kingsley Avenue Ilfracombe Devon EX34 8ES Telephone: Facsimile: Web: +44 (0) 1271 856666 +44 (0) 1271 864894 www.lambda-gb.com LAMBDA NORTH AMERICA visit www.lambdapower.com for a list of Lambda offices and distributors LAMBDA ASIA visit www.densei-lambda.com for a list of Lambda offices and distributors LOCAL DISTRIBUTION 4 HWS Series (15-150W) Iss4 Jan08 H RIIEESS DW LPS SSEER