Powerbox C1505 Overvoltage protection with auto restart Datasheet

C1500 Series
EURO CASSETES
4 0 0 - 6 0 0 W AT T S A C / D C - D C / D C - B AT T E R Y C H A R G E R S S I N G L E O U T P U T
FEATURES
•
•
•
•
•
•
•
DC input 10 - 380 V
AC input 1 or 3-phase, 47 - 400 Hz
DC output 5-400V
Continuous short circuit protection
Overvoltage protection with auto restart
Industrial grade components
Compact and robust design
DC/DC CONVERTERS
400 W
500 W
600 W
INPUT VDC
OUTPUT VDC
10 –16
VDC
OUTPUT
AMPS
18 – 36
VDC
OUTPUT
AMPS
36 – 75
VDC
45 – 90
VDC
80 –160
VDC
160 – 320
VDC
320 – 380
VDC
OUTPUT
AMPS
ADJ.
RANGE
C 1500
C 1501
C 1502
C 1503
C 1504
C 1505
C 1509
C 1506
C 1507
C 1507 J
C 1508
C 1508 J
40
25
24
20
15
13
7
5.5
3
2
1.4
1
C 1520
C 1521
C 1522
C 1523
C 1524
C 1525
C 1529
C 1526
C 1527
C 1527 J
C 1528
C 1528 J
60
38
33
25
18
15
8
6.5
3.3
2.5
1.6
1.3
C 1530
C 1531
C 1532
C 1533
C 1534
C 1535
C 1539
C 1536
C 1537
C 1537 J
C 1538
C 1538 J
C 1540
C 1541
C 1542
C 1543
C 1544
C 1545
C 1549
C 1546
C 1547
C 1547 J
C 1548
C 1548 J
C 1550
C 1551
C 1552
C 1553
C 1554
C 1555
C 1559
C 1556
C 1557
C 1557 J
C 1558
C 1558 J
C 1570
C 1571
C 1572
C 1573
C 1574
C 1575
C 1579
C 1576
C 1577
C 1577 J
C 1578
C 1578 J
C 1580 Z
C 1581 Z
C 1582 Z
C 1583 Z
C 1584 Z
C 1585 Z
C 1589 Z
C 1586 Z
C 1587 Z
C 1587 ZJ
C 1588 Z
C 1588 ZJ
80
50
42
34
23
20
11
9
4.5
3
2.4
1.5
5
9
12
15
24
28
48
60
110
200
220
400
4.5 – 5.5
8 – 10
11 – 13
14 – 16
23 – 26
26 – 30
45 – 55
58 – 68
100 – 130
190 – 200
200 – 250
380 – 400
AC/DC POWER SUPPLIES
BATTERY CHARGERS
600 W
600 W
INPUT VAC, 1-PHASE
INPUT VAC,
3-PHASE
+ 15%
115 ± 20% 230
– 20%
115 ± 20%
230 + 15%
– 20%
3X200 + 15%
– 20%
C 1580
C 1560
C 1581
C 1561
C 1582
C 1562
C 1583
C 1563
C 1584
C 1564
C 1585
C 1565
C 1589
C 1569
C 1586
C 1566
C 1587
C 1567
C
1587 J
C 1567 J
C 1588
C 1568
C 1568 J C 1588 J
C 1590
C 1591
C 1592
C 1593
C 1594
C 1595
C 1599
C 1596
C 1597
C 1597 J
C 1598
C 1598 J
C 1560 V
C 1561 V
C 1562 V
C 1563 V
C 1564 V
C 1565 V
C 1569 V
C 1566 V
C 1567 V
C 1567 VJ
C 1568 V
C 1568 VJ
Doc. No. PBC9 Rev.C 28-4-11
INPUT VAC, 1-PHASE
OUTPUT VDC
OUTPUT
AMPS
80
50
42
34
23
20
11
9
4.5
3
2.4
1.5
ADJ.
RANGE
5
9
12
15
24
28
48
60
110
200
220
400
4.5 – 5.5
8 – 10
11 – 13
14 – 16
23 – 26
26 – 30
45 – 55
58 – 68
100 – 130
190 – 200
200 – 250
380 – 400
115 ±
20%
230 +
15%
– 20%
B 1561
B 1562
B 1564
B 1566
B 1567
B 1568
B 1581
B 1582
B 1584
B 1586
B 1587
B 1588
INPUT VAC,
3-PHASE
OUTPUT VDC
OUTPUT
115 ± 20% 3X200 + 15% AMPS
230 + 15%
– 20%
– 20%
B 1591
B 1592
B 1594
B 1596
B 1597
B 1598
Powering Progress – www.powerbox.com.au
B 1561 V
B 1562 V
B 1564 V
B 1566 V
B 1567 V
B 1568 V
34
18
9
7.5
4
2
NOM.
BATTERY
VOLTAGE
RANGE
12
24
48
60
110
220
12 – 16
24 – 32
48 – 64
60 – 80
110 – 145
220 – 290
Euro Series
OPTIONS
INPUT
Option “i” (inrush current limiting): A thermistor is connected in series with the
input lines which changes its resistance from high to low when it gets hot. It does
not reduce the current surge if the input power is interrupted for a short period of
time not allowing the thermistor to cool down. Thermistors are fitted as standard
to all mains input models except for 1-phase input of models > 2.5kW.
Thermistors are available up to 45A. For higher input current an electronic inrush
current limitation can be offered.
Option “y” (sys-reset): This logic signal is a combination of power fail and DC-ok
as specified for VME systems.
Option “r” (relay): A relay instead of a logic signal is provided for failure
indication.`
PROGRAMMING & MONITORING
Option “ie” electronic inrush current limiting An electronic circuit limits the inrush
current.
Option “sd” (series diode): A series diode protects the module against input
voltage of wrong polarity (additional power losses).
PROGRAMMING SERIES 200-5800, 6600
Of output voltage
from 0 to 100%
Option “ad” (anti-parallel diode): To avoid the power losses of a series diode a diode is
provided with opposite polarity in parallel to the input blowing an internal or external
fuse if the module is connected to a supply with wrong polarity.
Option “au” (auto-ranging) For standard dual AC input models the range of
115/230Vac is to be selected by connecting the input line to different pins on the
connector. With auto-ranging the unit senses the input voltage and provides
automatically the correct connection.
Of output current
from 0 to 100%
By external signal, 0-10Vdc
eu1
By external signal, 4-20mA
eu2
By 270° potentiometer
eu3
By 10 turn potentiometer
eu4
By external signal, 0-10Vdc
ei1
By external signal, 4-20mA
ei2
By 270° potentiometer
ei3
By 10 turn potentiometer
ei4
Isolating amplifier for programming
Option “p” (power fail): A signal (logic or relay) is given if the input voltage (AC or
DC) drops below the specified limit. In AC input units we sense the rectified input
voltage so that a power fail alarm will not be triggered if at light loads mains
power returns before the input capacitors are substantially discharged.
Option “r” (relay): A relay instead of a logic signal is provided for failure indication.
OUTPUT
Option “dd” (decoupling diode): For redundant operation the outputs of two or
more units are paralleled behind de-coupling diodes so that an internal fault of
one module does not affect the operation of the others. These diodes cause power
losses.
Option “cs” (active current sharing): An additional control circuit provides active
current sharing via an interconnecting wire between converters that operate in
parallel. Active current sharing should be used for multi-output units operating in
parallel.
Option “csi” (current sharing interrupt): Option “csi” will effect the removal of the
“cs” signal. Should there be an instance where a unit is not supplying the load,
then the effect of its “cs” signal is removed, and the load voltage is unaffected by
this condition.
Option “h1” (inhibit): A terminal connected to the negative input line also shuts off the
converter. This can also be used in conjunction with a thermal trip which shuts the unit
down.
Programming via interface RS232 or IEEE488
MONITORING SERIES 200-5800, 6600
Of output voltage
from 0 to 100%
By external signal, 0-10Vdc
mu1
By external signal, 4-20mA
mu2
Of output current
from 0 to 100%
By external signal, 0-10Vdc
mi1
By external signal, 4-20mA
mi2
Isolating amplifier for programming
iso
Programming via interface RS232 or IEEE488
CHARGER PROGRAMMING (ALL SERIES)
Temperature compensated charging voltage(sensor not included)
Not interchangeable due to fixed
resistor values
Temperature sensor
Interchangeable, IC controlled
Automatic selection of charging characteristic (float / equalize
charge) with timer
Additionally: Manual selection of charging characteristic
Additionally: Boost charge operation (manually activated with
time delayed return to normal operation)
Option “h2” (inhibit): Operation of the unit is inhibited if a voltage signal
(5V/10mA) is applied in reference to the negative line of the (main) output.
Option “rco” (reducing current limiting at over temperature) A circuit reduces the
current limiting level at higher temperature (to be specified).
Option “d” (DC-ok, one output): A logic signal is given if the output voltage (main
output in multi-output systems) is below the specified limit.
Option “m” (DC-ok, all outputs): In multi-output systems a logic signal is provided
if the voltage of any output is below the specified limit.
Option “ac” (AC ok) A logic signal connected to relay contacts is given if the
output voltage of an inverter is below the specified limit.
Doc. No. PBC9 Rev.C 28-4-11
iso
Powering Progress – www.powerbox.com.au
tc
ts1
ts2
ch1
ch2
ch3
EURO CASSETES
E U R O O P T I O N S P E C I F I C AT I O N S
EURO CASSETES
Euro Series
E U R O O P T I O N S P E C I F I C AT I O N S
PROGRAMMING / MONITORING- SERIES 6400
Programming of output voltage By external signal, 0-10Vdc
and current from 0-100%
including isolation
By external signal, 4-20mA
e1
Programming of output voltage By 270° potentiometer
from 0-100%
By 10 turn potentiometer
eu3
Programming of output current By 270° potentiometer
from 0-100%
By 10 turn potentiometer
ei3
Monitoring of output voltage
and current from 0-100%
including isolation
Remote on/off programming
and monitoring of output
voltage and current from
0-100% including isolation
By external signal, 0-10Vdc
m1
By external signal, 4-20mA
m2
By external signal, 0-10Vdc
em1
By external signal, 4-20mA
em2
Via RS232 and IEEE488
em3
Improved tolerance
Between reference (external
signal) and measured value /
between measured value and
displayed signal: voltage 0.2%
and current 0.5%.
e2
eu4
ei4
tol
ENVIRONMENT
Option “t” (tropical protection):The unit is given additional protection by a heavy
coat of varnish on the printed circuit board(s) and components.
Option “c” (extended temperature range):The circuit is designed and tested for
operation at an ambient temperature as low as –40 °C.
Option “ms” (increased mechanical strength): Screws are secured by Locktite and
heavy components are fastened by ties and/or glue. Modules with the “ms” option
meet the standard EN61373 regarding shock and vibration.
MECHANICS
Standard mounting “Eurocassette” pluggable module for 19” sub-racks 84TE
Option “w” (wall mounting): Module is screwed against a mounting plate for
installation in a cabinet. The load connections are typically a terminal block.
Option “cha” (chassis mount) Module is designed for installation to a structure or
within cabinet. Screw type connectors are supplied with the module.
Option “din” (DIN rail mount) Module is designed for DIN rail mounting to a
structure or within Cabinet. Screw type connectors are supplied with the module.