Kemet CX05D225K T322 and t323 series milâ prfâ 49137/1 and 5 (cx01 and cx05 style) Datasheet

Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF–49137/1 and 5
(CX01 and CX05 Style)
Overview
The KEMET T322 and T323 Series (CX01 and CX05 Style)
offers a complete line of extended range molded solid tantalum
capacitors designed specifically for high speed automatic
insertion applications. These capacitors offer an extremely high
capacitance-to-volume ratio while still maintaining excellent
performance characteristics. Supplied in six axial lead tubular
case sizes, these capacitors are ideally suited for use in printed
wiring boards and all applications requiring a high degree of
packaging density and can be supplied in bulk packaging or
lead-taped on reels. The 322/T323 Series dimensions and tight
lead wire-to-body concentricity permit installation by the same
automatic insertion equipment used for diodes and resistors.
These capacitors are available in working voltages of 2, 4, 6, 10,
15, 20, 25, 35 and 50 volts. The operating temperature range
-55°C to +85°C at full rated voltage and with 2/3 85°C rated
voltage at 125°C. The gold color epoxy permits laser marking with
outstanding permanency and legibility. T323 Series capacitors are
qualified under MIL–PRF–49137/1 and 5 as Military Style CX01
and CX05. Typical applications include decoupling, blocking,
bypassing and filtering in commercial computers, data processing,
communications, and other electronic equipment. This product is
well-suited for decoupling required by high speed computers due
to its low ESR/impedance at high frequencies.
Benefits
Applications
•
•
•
•
•
Typical applications include decoupling, blocking, bypassing
and filtering in commercial computers, data processing,
communications, and other electronic equipment. This product is
well-suited for decoupling required by high speed computers due
to its low ESR/impedance at high frequencies.
Taped and reeled per EIA Specification RS–296
Laser-marked case
Qualified to MIL–PRF–49137/1 and 5 (CX01 and CX05 Style)
Capacitance values of 0.1 μF to 330 μF
Tolerances of ±5%, ±10% and ±20% (M and K only tolerances
available for T323 Series)
• Voltage rating of 2 – 50 VDC
• Operating temperature range of -55˚C to +85˚C
• Case sizes: A, B, C, D, E, F
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
1
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Ordering Information
T
Capacitor
Class
T=
Tantalum
32X
A
474
Series
Case
Size
Capacitance Code
(pF)
Capacitance Rated Voltage Failure Rate/Military
Tolerance
(VDC)
Product
A, B,
C, D,
E, F
First two digits
represent significant
figures. Third digit
specifies number of
zeros to follow.
J = ±5%
K = ±10%
M = ±20%
Axial Molded Polar
Solid Tantalum.
Insert appropriate
number to replace
letter ""X"" = 322
or 323 (CX01 or
CX05).
M
035
002 = 2
004 = 4
006 = 6
010 = 10
015 = 15
020 = 20
025 = 25
035 = 35
050 = 50
A
Not Applicable
T
Termination Finish
T = 100% tin
S = standard
(solder-coated
nickel)
Packaging
(When necessary)
Reeling per EIA
Specification RS296
Blank = Bulk
7200 = Reel
MIL–PRF–49137/1/5 (CX01 and CX05 Style)
CX
05
D
225
K
Capacitor Class
Series
Rated Voltage
(VDC)
Capacitance
Code (pF)
Capacitance
Tolerance
CX = MIL-PRF
01 = T322
05 = T323
D=6
F = 10
H = 15
J = 20
K = 25
M = 35
N = 50
First two digits
represent significant
figures. Third digit
specifies number of
zeros to follow.
K = ±10%
M = ±20%
Performance Characteristics
Item
Performance Characteristics
Operating Temperature
Rated Capacitance Range
Capacitance Tolerance
Rated Voltage Range
DF (120 Hz @ 25°C)
ESR and Impedance (100 kHz @ 25°C)
Leakage Current
-55°C to 125°C
0.1 – 330 μF @ 120 Hz/25°C
J Tolerance (5%), K Tolerance (10%), M Tolerance (20%)
2 – 50 V
Refer to Part Number Electrical Specification Table
Refer to Part Number Electrical Specification Table (for reference only) Refer to Part Number Electrical Specification Table (@ rated voltage up to +85°C and 2/3 of rated
voltage applied at 125°C)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
2
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Dimensions – Millimeters (Inches)
Metric will govern
Case Size
D Maximum
L Maximum
W
A
0.095 (2.41)
0.260 (6.6)
0.020 (.51)
B
0.110 (2.79)
0.290 (7.37)
0.020 (.51)
C
0.180 (4.57)
0.345 (8.76)
0.020 (.51)
D
0.180 (4.57)
0.420 (10.67)
0.020 (.51)
E
0.280 (7.11)
0.530 (13.46)
0.025 (.64)
F
0.300 (7.62)
0.710 (18.03)
0.025 (.64)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
3
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Table 1 – Ratings & Part Number Reference
Rated
Voltage
Rated
Cap
VDC
µF
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
4.7
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
3.3
3.9
4.7
4.7
4.7
5.6
5.6
5.6
6.8
6.8
6.8
8.2
8.2
8.2
10.0
10.0
10.0
12.0
12.0
12.0
15.0
15.0
15.0
18.0
22.0
27.0
33.0
33.0
VDC
µF
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
DC
Leakage
DF
A
A
A
B
B
B
B
B
B
C
C
C
C
A
A
A
B
B
B
B
B
B
C
C
C
C
D
D
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
(See below for
part options)
T322A685(1)002A(2)
T322A825(1)002A(2)
T322A106(1)002A(2)
T322B126(1)002A(2)
T322B156(1)002A(2)
T322B186(1)002A(2)
T322B226(1)002A(2)
T322B276(1)002A(2)
T322B336(1)002A(2)
T322C396(1)002A(2)
T322C476(1)002A(2)
T322C566(1)002A(2)
T322C686(1)002A(2)
T322A475(1)004A(2)
T322A565(1)004A(2)
T322A685(1)002A(2)
T322B825(1)004A(2)
T322B106(1)004A(2)
T322B126(1)004A(2)
T322B156(1)004A(2)
T322B186(1)004A(2)
T322B226(1)004A(2)
T322C276(1)004A(2)
T322C336(1)004A(2)
T322C396(1)004A(2)
T322C476(1)004A(2)
T322D566(1)004A(2)
T322D686(1)004A(2)
T322A335(1)006A(2)
T322A395(1)006A(2)
T322A475J006A(2)
T322A475K006A(2)
T322A475M006A(2)
T322B565J006A(2)
T322B565K006A(2)
T322B565M006A(2)
T322B685J006A(2)
T322B685K006A(2)
T322B685M006A(2)
T322B825J006A(2)
T322B825K006A(2)
T322B825M006A(2)
T322B106J006A(2)
T322B106K006A(2)
T322B106M006A(2)
T322B126J006A(2)
T322B126K006A(2)
T322B126M006A(2)
T322B156J006A(2)
T322B156K006A(2)
T322B156M006A(2)
T322C186(1)006A(2)
T322C226(1)006A(2)
T322C276(1)006A(2)
T322C336J006A(2)
T322C336K006A(2)
(see below for
part options)
µA @ 25°C
Max/5 Minimum
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.8
0.9
1.1
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.7
0.9
1.1
1.2
1.5
1.8
2.2
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.7
0.7
0.9
1.1
1.3
1.5
1.5
µA @ 25°C
Max/5 Minimum
% @ 25°C
120 Hz Maximum
10
10
10
10
10
10
10
10
10
10
10
10
10
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
% @ 25°C
120 Hz Maximum
KEMET Part Number
DC
Leakage
DF
Case Code/
Case Size
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
Military Part Number
KEMET Part Number
CX05D475K
CX05D475M
T323A475K006A(2)
T323A475M006A(2)
CX01D565K
CX01D565M
T323B565K006A(2)
T323B565M006A(2)
CX01D685K
CX01D685M
T323B685K006A(2)
T323B685M006A(2)
CX01D825K
CX01D825M
T323B825K006A(2)
T323B825M006A(2)
CX01D106K
CX01D106M
T323B106K006A(2)
T323B106M006A(2)
CX01D126K
CX01D126M
T323B126K006A(2)
T323B126M006A(2)
CX05D156K
CX05D156M
T323B156K006A(2)
T323B156M006A(2)
CX05D336K
T323C336K006A(2)
Military Part Number
KEMET Part Number
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
(1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
4
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated
Cap
VDC
µF
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15
15
33.0
39.0
47.0
47.0
47.0
56.0
68.0
82.0
100.0
120.0
150.0
180.0
220.0
270.0
330.0
2.2
2.7
3.3
3.3
3.3
3.9
4.7
5.6
6.8
8.2
10.0
10.0
10.0
12.0
15.0
18.0
22.0
22.0
22.0
27.0
27.0
27.0
33.0
33.0
33.0
39.0
39.0
39.0
47.0
47.0
47.0
56.0
68.0
82.0
100.0
120.0
150.0
180.0
220.0
1.5
1.8
VDC
µF
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
DC
Leakage
DF
C
D
D
D
D
D
D
E
E
E
E
E
E
F
F
A
A
A
A
A
B
B
B
B
B
B
B
B
C
C
C
C
C
C
D
D
D
D
D
D
D
D
D
D
D
D
E
E
E
E
E
E
F
F
A
A
(See below for
part options)
T322C336M006A(2)
T322D396(1)006A(2)
T322D476J006A(2)
T322D476K006A(2)
T322D476M006A(2)
T322D566(1)006A(2)
T322D686(1)006A(2)
T322E826(1)006A(2)
T322E107(1)006A(2)
T322E127(1)006A(2)
T322E157(1)006A(2)
T322E187(1)006A(2)
T322E227(1)006A(2)
T322F277(1)006A(2)
T322F337(1)006A(2)
T322A225(1)010A(2)
T322A275(1)010A(2)
T322A335J010A(2)
T322A335K010A(2)
T322A335M010A(2)
T322B395(1)010A(2)
T322B475(1)010A(2)
T322B565(1)010A(2)
T322B685(1)010A(2)
T322B825(1)010A(2)
T322B106J010A(2)
T322B106K010A(2)
T322B106M010A(2)
T322C126(1)010A(2)
T322C156(1)010A(2)
T322C186(1)010A(2)
T322C226J010A(2)
T322C226K010A(2)
T322C226M010A(2)
T322D276J010A(2)
T322D276K010A(2)
T322D276M010A(2)
T322D336J010A(2)
T322D336K010A(2)
T322D336M010A(2)
T322D396J010A(2)
T322D396K010A(2)
T322D396M010A(2)
T322D476J010A(2)
T322D476K010A(2)
T322D476M010A(2)
T322E566(1)010A(2)
T322E686(1)010A(2)
T322E826(1)010A(2)
T322E107(1)010A(2)
T322E127(1)010A(2)
T322E157(1)010A(2)
T322F187(1)010A(2)
T322F227(1)010A(2)
T322A155(1)015A(2)
T322A185(1)015A(2)
(see below for
part options)
µA @ 25°C
Max/5 Minimum
1.5
1.9
2.3
2.3
2.3
2.7
3.3
3.9
4.8
5.0
5.0
8.6
10.0
10.0
10.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.7
0.8
0.8
0.8
1.0
1.2
1.4
1.5
1.5
1.5
2.2
2.2
2.2
2.6
2.6
2.6
3.1
3.1
3.1
3.8
3.8
3.8
4.4
5.0
5.0
8.0
9.6
10.0
10.0
10.0
0.5
0.5
µA @ 25°C
Max/5 Minimum
% @ 25°C
120 Hz Maximum
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
4
6
6
6
6
6
6
6
6
8
8
8
8
8
8
4
4
% @ 25°C
120 Hz Maximum
KEMET Part Number
DC
Leakage
DF
Case Code/
Case Size
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
Military Part Number
KEMET Part Number
CX05D336M
T323C336M006A(2)
CX05D476K
CX05D476M
T323D476K006A(2)
T323D476M006A(2)
CX05F335K
CX05F335M
T323A335K010A(2)
T323A335M010A(2)
CX05F106K
CX05F106M
T323B106K010A(2)
T323B106M010A(2)
CX05F226K
CX05F226M
T323C226K010A(2)
T323C226M010A(2)
CX05F276K
CX05F276M
T323D276K010A(2)
T323D276M010A(2)
CX05F336K
CX05F336M
T323D336K010A(2)
T323D336M010A(2)
CX05F396K
CX05F396M
T323D396K010A(2)
T323D396M010A(2)
CX05F476K
CX05F476M
T323D476K010A(2)
T323D476M010A(2)
Military Part Number
KEMET Part Number
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
(1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
5
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated
Cap
VDC
µF
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
2.2
2.2
2.2
2.7
3.3
3.9
4.7
5.6
6.8
6.8
6.8
8.2
10.0
12.0
15.0
15.0
15.0
18.0
22.0
22.0
22.0
27.0
33.0
33.0
33.0
39.0
47.0
56.0
68.0
82.0
100.0
120.0
150.0
1.0
1.2
1.5
1.5
1.5
1.8
2.2
2.7
3.3
3.9
4.7
4.7
4.7
5.6
6.8
8.2
10.0
12.0
12.0
12.0
15.0
15.0
15.0
VDC
µF
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
DC
Leakage
DF
A
A
A
B
B
B
B
B
B
B
B
C
C
C
C
C
C
D
D
D
D
D
D
D
D
E
E
E
E
E
E
F
F
A
A
A
A
A
B
B
B
B
B
B
B
B
C
C
C
C
D
D
D
D
D
D
(See below for
part options)
T322A225J015A(2)
T322A225K015A(2)
T322A225M015A(2)
T322B275(1)015A(2)
T322B335(1)015A(2)
T322B395(1)015A(2)
T322B475(1)015A(2)
T322B565(1)015A(2)
T322B685J015A(2)
T322B685K015A(2)
T322B685M015A(2)
T322C825(1)015A(2)
T322C106(1)015A(2)
T322C126(1)015A(2)
T322C156J015A(2)
T322C156K015A(2)
T322C156M015A(2)
T322D186(1)015A(2)
T322D226J015A(2)
T322D226K015A(2)
T322D226M015A(2)
T322D276(1)015A(2)
T322D336J015A(2)
T322D336K015A(2)
T322D336M015A(2)
T322E396(1)015A(2)
T322E476(1)015A(2)
T322E566(1)015A(2)
T322E686(1)015A(2)
T322E826(1)015A(2)
T322E107(1)015A(2)
T322F127(1)015A(2)
T322F157(1)015A(2)
T322A105(1)020A(2)
T322A125(1)020A(2)
T322A155J020A(2)
T322A155K020A(2)
T322A155M020A(2)
T322B185(1)020A(2)
T322B225(1)020A(2)
T322B275(1)020A(2)
T322B335(1)020A(2)
T322B395(1)020A(2)
T322B475J020A(2)
T322B475K020A(2)
T322B475M020A(2)
T322C565(1)020A(2)
T322C685(1)020A(2)
T322C825(1)020A)2)
T322C106(1)020A(2)
T322D126J020A(2)
T322D126K020A(2)
T322D126M020A(2)
T322D156J020A(2)
T322D156K020A(2)
T322D156M020A(2)
(see below for
part options)
µA @ 25°C
Max/5 Minimum
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.7
0.8
0.8
0.8
1.0
1.2
1.4
1.5
1.5
1.5
2.2
2.6
2.6
2.6
3.2
4.0
4.0
4.0
4.7
5.0
6.7
8.2
9.8
10.0
10.0
10.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.8
0.8
0.8
0.9
1.1
1.3
1.6
1.9
1.9
1.9
2.4
2.4
2.4
µA @ 25°C
Max/5 Minimum
% @ 25°C
120 Hz Maximum
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
% @ 25°C
120 Hz Maximum
KEMET Part Number
DC
Leakage
DF
Case Code/
Case Size
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
Military Part Number
KEMET Part Number
CX05H225K
CX05H225M
T323A225K015A(2)
T323A225M015A(2)
CX05H685K
CX05H685M
T323B685K015A(2)
T323B685M015A(2)
CX05H156K
CX05H156M
T323C156K015A(2)
T323C156M015A(2)
CX06H226K
CX06H226M
T323D226K015A(2)
T323D226M015A(2)
CX05H336K
CX05H336M
T323D336K015A(2)
T323D336M015A(2)
CX05J155K
CX05J155M
T323A155K020A(2)
T323A155M020A(2)
CX05J475K
CX05J475M
T323B475K020A(2)
T323B475M020A(2)
CX05J126K
CX05J126M
T323D126K020A(2)
T323D126M020A(2)
CX05J156K
CX05J156M
T323D156K020A(2)
T323D156M020A(2)
Military Part Number
KEMET Part Number
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
(1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
6
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated
Cap
VDC
µF
20
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
35
35
35
35
35
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
82.0
100.0
0.47
0.56
0.68
0.82
1.0
1.0
1.0
1.2
1.5
1.5
1.5
1.8
1.8
1.8
2.2
2.2
2.2
2.7
3.3
3.3
3.3
3.9
4.7
5.6
6.8
6.8
6.8
8.2
10.0
10.0
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
0.1
0.12
0.15
0.18
0.22
VDC
µF
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
DC
Leakage
DF
D
D
E
E
E
E
E
E
F
F
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
D
D
E
E
E
E
E
E
F
F
A
A
A
A
A
(See below for
part options)
T322D186(1)020A(2)
T322D226(1)020A(2)
T322E276(1)20A(2)
T322E336(1)020A(2)
T322E396(1)020A(2)
T322E476(1)20A(2)
T322E566(1)020A(2)
T322E686(1)020A(2)
T322F826(1)020A(2)
T322F107(1)020A(2)
T322A474(1)025A(2)
T322A564(1)025A(2)
T322A684(1)025A(2)
T322A824(1)025A(2)
T322A105J025A(2)
T322A105K025A(2)
T322A105M025A(2)
T322B125(1)025A(2)
T322B155J025A(2)
T322B155K025A(2)
T322B155M025A(2)
T322B185J025A(2)
T322B185K025A(2)
T322B185M025A(2)
T322B225J025A(2)
T322B225K025A(2)
T322B225M025A(2)
T322B275(1)025A(2)
T322B335J025A(2)
T322B335K025A(2)
T322B335M025A(2)
T322C395(1)025A(2)
T322C475(1)025A(2)
T322C565(1)025A(2)
T322C685J025A(2)
T322C685K025A(2)
T322C685M025A(2)
T322C825(1)025A)2)
T322C106J025A(2)
T322C106K025A(2)
T322C106M025A(2)
T322D126(1)025A(2)
T322D156(1)025A(2)
T322E186(1)025A(2)
T322E226(1)025A(2)
T322E276(1)025A(2)
T322E336(1)025A(2)
T322E396(1)025A(2)
T322E476(1)025A(2)
T322F566(1)025A(2)
T322F686(1)025A(2)
T322A104(10035A(2)
T322A124(1)035A(2)
T322A154(1)035A(2)
T322A184(1)035A(2)
T322A224(1)035A(2)
(see below for
part options)
µA @ 25°C
Max/5 Minimum
2.9
3.5
4.3
5.0
6.2
7.5
8.9
10.0
10.0
10.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.7
0.7
0.7
0.8
0.9
1.1
1.4
1.4
1.4
1.4
1.5
1.5
1.5
2.4
3.0
3.6
4.4
5.4
6.6
7.9
9.4
10.0
10.0
0.5
0.5
0.5
0.5
0.5
µA @ 25°C
Max/5 Minimum
% @ 25°C
120 Hz Maximum
6
6
6
6
6
6
6
6
8
8
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
3
3
3
3
3
% @ 25°C
120 Hz Maximum
KEMET Part Number
DC
Leakage
DF
Case Code/
Case Size
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
Military Part Number
KEMET Part Number
CX05K105K
CX05K105M
T323A105K025A(2)
T323A105M025A(2)
CX05K155K
CX05K155M
T323B155K025A(2)
T323B155M025A(2)
CX05K185K
CX05K185M
T323B185K025A(2)
T323B185M025A(2)
CK05K225K
CK05K225M
T323B225K025A(2)
T323B225M025A(2)
CX05K335K
CX05K335M
T323B335K025A(2)
T323B335M025A(2)
CX05K685K
CX05K685M
T323C685K025A(2)
T323C685M025A(2)
CX05K106K
CX05K106M
T323C106K025A(2)
T323C106M025A(2)
Military Part Number
KEMET Part Number
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
(1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
7
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated
Cap
VDC
µF
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
50
50
0.27
0.33
0.33
0.33
0.39
0.47
0.47
0.47
0.56
0.56
0.56
0.68
0.68
0.68
0.82
0.82
0.82
1.0
1.0
1.0
1.2
1.2
1.2
1.5
1.5
1.5
1.8
2.2
2.7
3.3
3.3
3.3
3.9
3.9
3.9
4.7
4.7
4.7
5.6
6.8
6.8
6.8
8.2
10.0
10.0
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
0.1
0.1
VDC
µF
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
DC
Leakage
DF
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
C
C
D
D
D
D
D
D
D
D
E
E
E
E
E
E
F
F
A
A
(See below for
part options)
T322A274(1)035A(2)
T322A334J035A(2)
T322A334K035A(2)
T322A334M035A(2)
T322A394(1)035A(2)
T322A474J035A(2)
T322A474K035A(2)
T322A474M035A(2)
T322B564J035A(2)
T322B564K035A(2)
T322B564M035A(2)
T322B684J035A(2)
T322B684K035A(2)
T322B684M035A(2)
T322B824J035A(2)
T322B824K035A(2)
T322B824M035A(2)
T322B105J035A(2)
T322B105K035A(2)
T322B105K035A(2)
T322B125J035A(2)
T322B125K035A(2)
T322B125M035A(2)
T322B155J035A(2)
T322B155K035A(2)
T322B155M035A(2)
T322C185(1)035A(2)
T322C225(1)035A(2)
T322C275(1)035A(2)
T322C335J035A(2)
T322C335K035A(2)
T322C335M035A(2)
T322C395J035A(2)
T322C395K035A(2)
T322C395M035A(2)
T322C475J035A(2)
T322C475K035A(2)
T322C475M035A(2)
T322C565M035A(2)
T322D685J035A(2)
T322D685K035A(2)
T322D685M035A(2)
T322D825(1)035A(2)
T322D106J035A(2)
T322D106K035A(2)
T322D106M035A(2)
T322E126(1)035A(2)
T322E156(1)035A(2)
T322E186(1)035A(2)
T322E226(1)035A(2)
T322E276(1)035A(2)
T322E336(1)035A(2)
T322F396(1)035A(2)
T322F476(1)035A(2)
T322A104J050A(2)
T322A104K050A(2)
(see below for
part options)
µA @ 25°C
Max/5 Minimum
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.8
0.9
0.9
0.9
1.1
1.1
1.1
1.3
1.3
1.3
1.6
1.9
1.9
1.9
2.3
2.8
2.8
2.8
3.3
4.2
5.0
6.2
7.5
9.2
10.0
10.0
0.5
0.5
µA @ 25°C
Max/5 Minimum
% @ 25°C
120 Hz Maximum
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
3
3
% @ 25°C
120 Hz Maximum
KEMET Part Number
DC
Leakage
DF
Case Code/
Case Size
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
Military Part Number
KEMET Part Number
CX05M334K
CX05M334M
T323A334K035A(2)
T323A334M035A(2)
CX05M474K
CX05M474K
T323A474K035A(2)
T323A474K035A(2)
CX01M564K
CX01M564M
T323B564K035A(2)
T323B564M035A(2)
CX01M684K
CX01M684M
T322B684K035A(2)
T322B684M035A(2)
CX01M824K
CX01M824M
T323B824K035A(2)
T323B824M035A(2)
CX01M105K
CX01M105M
T323B105K035A(2)
T323B105M035A(2)
CX01M125K
CX01M125M
T323B125K035A(2)
T323B125M035A(2)
CX05M155K
CX05M155M
T323B155K035A(2)
T323B155M035A(2)
CX05M335K
CX05M335M
T323C335K035A(2)
T323C335M035A(2)
CX05M395K
CX05M395M
T323C395K035A(2)
T323C395M035A(2)
CX05M475K
CX05M475M
T323C475K035A(2)
T322C475M035A(2)
CX05M685K
CX05M685M
T323D685K035A(2)
T323D685M035A(2)
CX05M106K
CX05M106M
T323D106K035A(2)
T323D106M035A(2)
CX05N104K
T323A104K050A(2)
Military Part Number
KEMET Part Number
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
(1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
8
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated
Cap
VDC
µF
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
0.1
0.12
0.15
0.15
0.15
0.18
0.22
0.22
0.22
0.27
0.33
0.33
0.33
0.39
0.39
0.39
0.47
0.47
0.47
0.56
0.68
0.68
0.68
0.82
1.0
1.0
1.0
1.2
1.5
1.5
1.5
1.8
2.2
2.2
2.2
2.7
3.3
3.3
3.3
3.9
4.7
4.7
4.7
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
VDC
µF
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
DC
Leakage
DF
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
D
D
D
D
D
D
D
D
E
E
E
E
F
F
F
F
(See below for
part options)
T322A104M050A(2)
T322A124(1)050A(2)
T322A154J050A(2)
T322A154K050A(2)
T322A154M050A(2)
T322A184(1)050A(2)
T322A224J050A(2)
T322A224K050A(2)
T322A224M050A(2)
T322A274(1)050A(2)
T322B334J050A(2)
T322B334K050A(2)
T322B334M050A(2)
T322B394J050(2)
T322B394K050A(2)
T322B394M050A(2)
T322B474J050A(2)
T322B474K050A(2)
T322B474M050A(2)
T322B564(1)050A(2)
T322B684J050A(2)
T322B684K050A(2)
T322B684M050A(2)
T322B824(1)050A(2)
T322B105J050A(2)
T322B105K050A(2)
T322B105M050A(2)
T322C125(1)050A(2)
T322C155J050A(2)
T322C155K050A(2)
T322C155M050A(2)
T322C185(1)050A(2)
T322C225J050A(2)
T322C225K050A(2)
T322C225M050A(2)
T322D275(1)050A(2)
T322D335J050A(2)
T322D335K050A(2)
T322D335M050A(2)
T322D395(1)050A(2)
T322D475J050A(2)
T322D475K050A(2)
T322D475M050A(2)
T322E565(1)050A(2)
T322E685(1)050A(2)
T322E825(1)050A(2)
T322E106(1)050A(2)
T322F126(1)050A(2)
T322F156(1)050A(2)
T322F186(1)050A(2)
T322F226(1)050A(2)
(see below for
part options)
µA @ 25°C
Max/5 Minimum
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.9
0.9
0.9
1.1
1.3
1.3
1.3
1.6
1.9
1.9
1.9
2.2
2.7
3.2
4.0
4.8
6.0
7.2
8.8
µA @ 25°C
Max/5 Minimum
% @ 25°C
120 Hz Maximum
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
% @ 25°C
120 Hz Maximum
KEMET Part Number
DC
Leakage
DF
Case Code/
Case Size
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
Military Part Number
KEMET Part Number
CX05N104M
T323A104M050A(2)
CX05N154K
CX05N154M
T323A154K050A(2)
T323A154M050A(2)
CX05N224K
CX05N224M
T323A224K050A(2)
T323A224M050A(2)
CX05N334K
CX05N334M
T323B334K050A(2)
T323B334M050A(2)
CX05N394K
CX05N394M
T323B394K050A(2)
T323B394M050A(2)
CX05N474K
CX05N474M
T323B474K050A(2)
T323B474M050A(2)
CX05N684K
CX05N684M
T323B684K050A(2)
T323B684M050A(2)
CX05N105K
CX05N105M
T323B105K050A(2)
T323B105M050A(2)
CX05N155K
CX05N155M
T323C155K050A(2)
T323C155M050A(2)
CX05N225K
CX05N225M
T323C225K050A(2)
T323C225M050A(2)
CX05N335K
CX05N335M
T323D335K050A(2)
T323D335M050A(2)
CX05N475K
CX05N475M
T323D475K050A(2)
T323D475M050A(2)
Military Part Number
KEMET Part Number
CX01 & CX05 Capacitors per
MIL–PRF–49137/1 & 5
(1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
9
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Recommended Voltage Derating Guidelines
85°C to 125°C
VR
66% of VR
120%
100%
% Working Voltage
% Change in Working DC
Voltage with Temperature
-55°C to 85°C
80%
% Change in Working DC Voltage with
Temperature
60%
67%
40%
20%
0%
-55
25
45
85
Temperature (°C)
105
125
Ripple Current/Ripple Voltage
Permissible AC ripple voltage and current are related to equivalent
series resistance (ESR) and the power dissipation capabilities of
the device. Permissible AC ripple voltage that may be applied is
limited by following criteria:
1. Dissipated power must not exceed the limits specified for the
Series.
2. The positive peak AC voltage plus the DC bias voltage, if any,
must not exceed the DC voltage rating of the capacitor.
3. The negative peak AC voltage in combination with bias
voltage, if any, must not exceed the allowable limits specified for
reverse voltage.
Thermal capacities for the various case sizes have been
determined empirically and are listed below. The “ripple voltage”
permissible may be calculated from the impedance and ESR data
shown in the respective product section.
Temperature Compensation Multipliers
for Maximum Power Dissipation
T ≤ 25°C
1.00
T ≤ 85°C
0.90
T ≤ 125°C
0.40
T= Environmental Temperature
Maximum allowable rms ripple voltage or current may be
determined as follows:
I(max) = √P max/R
E(max) = √P max/R
I = rms ripple current (amperes)
E = rms ripple voltage (volts)
P max = Maximum power dissipation (watts)
R = ESR at specified frequency (ohms)
Case Size
Maximum Power Dissipation
(Pmax) Watts @ 25°C
A
B
C
D
E
F
0.060
0.070
0.080
0.090
0.100
0.110
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
10
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Optimum Solder Wave Profile
Capacitor Marking
105 M
+ 25 K
1535
Capacitance Code, Tolerance
Polarity, Voltage & KEMET trademark
DateCode (YY/WW)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
11
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Storage
Tantalum hermetically sealed capacitors should be stored in normal working environments. While the capacitors themselves are quite
robust in other environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres,
and long term storage. In addition, packaging materials will be degraded by high temperature– reels may soften or warp and tape peel
force may increase. KEMET recommends that maximum storage temperature not exceed 40ºC and maximum storage humidity not
exceed 60% relative humidity. Temperature fluctuations should be minimized to avoid condensation on the parts and atmospheres
should be free of chlorine and sulphur bearing compounds. For optimized solderability capacitors stock should be used promptly,
preferably within three years of receipt.
Tape & Reel Packaging Information
KEMET offers standard reeling of Solid Tantalum Capacitors for automatic insertion or lead forming machines per EIA Specification
RS-296E.
Table 2 – Packaging Quantity
Case Size
Standard Bulk Standard Reel
Reel C-Spec
Quantity
Quantity
Ammo Pack
Quantity
Ammo Pack
C-Spec
A
300
4500
2000
C-7293
B
250
4000
2000
Class I
C
100
2500
1000
C-7442
D
100
2500
1000
Class II
E
100
500
250
C-7443
F
100
500
250
Class III
C-7200
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
12
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Figure 2
Figure 3
12"
(30.48cm)
*
0.059" to 0.315"
Greater Than
Component
Length
White (+)
(Anode)
Blue ( –)
(Cathode)
0.047" Maximum
(1.20)
Hub
0.655" ±0.010
Hole
(15.9 ±0.25)
*
3 1 /4 "
(82.6)
1/ "
8
(3.18)
See Table 3
"B"
See Table 3
"A"
0.250" Nominal
(6.35)
Table 3 – Tape Dimensions
Component Body Diameter
Component
Pitch "A"
Inside Tape Spacing "B" ±1.5 mm (0.059")
0.020" or (±0.5 mm)
I
II
III
0" (0 mm) to 0.197" (5 mm)
0.200" or (5 mm)
2.062"
2.500"
2.874"
0.197" (5.01 mm) to 0.394" (10 mm)
0.400 or (10 mm)
(52.4 mm)
(63.5 mm)
(73 mm)
Capacitors are reeled so that positive leads are oriented as shown in Figure 3. Kraft paper (50lb. test minimum) is inserted between
the layers of capacitors wound on reels for component pitch ≤ 0.200" sizes and corrugated paper (70 lb. test minimum), single faced is
inserted for component pitch ≥ 0.400" sizes. Capacitor lead length may extend only a maximum of .031" (0.8 mm) beyond the tape’s
edges. Capacitors are centered in a row between the two tapes and will deviate only ±0.031" (0.79 mm) from the row center. Figures
1 and 2 show the KEMET standard chipboard tape reel. A minimum of 36" (91.5 cm) leader tape is provided at each end of the reeled
capacitors. Universal splicing clips are used to connect the tape.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
13
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Sasso Marconi, Italy
Tel: 39-051-939111
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Skopje, Macedonia
Tel: 389-2-55-14-623
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Wyboston, United Kingdom
Tel: 44-1480-273082
Taipei, Taiwan
Tel: 886-2-27528585
Espoo, Finland
Tel: 358-9-5406-5000
Southeast Asia
Singapore
Tel: 65-6701-8033
2835 KEMET Way
Simpsonville, SC 29681
Northeast
Wilmington, MA
Tel: 978-658-1663
Southeast
Lake Mary, FL
Tel: 407-855-8886
Central
Novi, MI
Tel: 248-994-1030
Beijing, China
Tel: 86-10-5877-1075
Shanghai, China
Tel: 86-21-6447-0707
Seoul, South Korea
Tel: 82-2-6294-0550
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Irving, TX
Tel: 972-915-6041
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
14
Tantalum Through-Hole Capacitors – Molded Axial
T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style)
Disclaimer
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are
not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use. The Information is intended for use only
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2039_T322_AXIAL_T323 • 9/9/2015
15
Similar pages