Bel ABC225-1T12L Rohs compliant Datasheet

The ABC225 Series of open-frame power supplies, with its wide
universal 90-264 VAC input range and high power density, is available
at 225 W of output power and a variety of single and multiple output
voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory
approvals for environmentally-friendly end products.
These power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
•
2 x 4 x 1 Inches Form Factor
•
225 W with Forced Air Cooling
•
Efficiencies up to 94%
•
-40 to 70 °C Operating Temperature
•
12 V Fan Output, Thermal Shut-Down Feature
•
3.37 Million Hours, Telcordia - SR332-Issue 3 MTBF
•
Standby Power <0.5 W
•
RoHS Compliant
•
CE Marked
•
Instrumentation
•
Renewable Energy
•
Lighting
•
Test and Measurement
•
Industrial Applications
•
Robotics
•
Applied Computing
•
Wireless Communication
ABC225 Series
2
MODEL NUMBER1
DESCRIPTION
ABC225-1T12L
ABC225-1012L
ABC225-1T15L
ABC225-1015L
ABC225-1T24L
ABC225-1024L
ABC225-1T30L
ABC225-1030L
ABC225-1T48L
ABC225-1048L
ABC225-1T58L
ABC225-1058L
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
VOLTAGE
MAX. LOAD
(CONVECTION)
(112.5 W)
MAX. LOAD
(CONVECTION)
(120 W)
MAX. LOAD
(13 CFM)
MIN. LOAD
RIPPLE &
NOISE2
12 V
9.37 A
10.0 A
18.75 A
0.0 A
1%
15 V
7.5 A
8.0 A
15 A
0.0 A
1%
24 V
4.68 A
5.0 A
9.37 A
0.0 A
1%
30 V
3.75 A
4.0 A
7.5 A
0.0 A
1%
48 V
2.34 A
2.5 A
4.68 A
0.0 A
1%
58 V
1.94 A
2.07 A
3.88 A
0.0 A
1%
COVER-225-XBC3 metal cover kit accessory
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Input Voltage
Universal
(Derate from 100% at 100 VAC to 90% at 85 VAC)
85-264 VAC / 390 VDC
Input Frequency
47-63 Hz
Input Current
115 VAC:
230 VAC:
2.2 A max.
1.1 A max.
No Load Power
Typical
< 0.5 W
115 VAC:
230 VAC:
264 VAC:
Typical (N.A. For Class II Option)
Touch current:
25 A
45 A
75 A
300 µA
<100 µA
Power Factor
With Full Load
>0.95
Switching Frequency
PFC:
PWM:
70 to 130 kHz
50-80 kHz
Inrush Current
Leakage Current
1
For Class II (without input Earth pin) add suffix -2 (e.g.: ABC225-1012L-2). Ensure non-metallic mounting stud when installing a Class II
product.
2
Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage
and load ranges.
3
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
[email protected]
ABC225 Series
3
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Output Power4
With 13 CFM:
Convection:
48 V:
24 V, 30 V:
12 V, 15 V:
225 W:
110 W:
225 W
Up to 120 W
94%
93%
92%
10 ms
16 ms
Efficiency
Hold-up Time
Line Regulation
+/-0.5%
Load Regulation
+/-0.5%
Transient Response
25% step load change, at 0.1A/µs slew rate,
50% duty cycle, 50 Hz = 4%
Recovery time < 5 ms
Rise Time
Typical
55 ms
Set Point Tolerance5
Output Voltage Adjustment
+/-1%
6
+/-3%
Over Current Protection
>110%
Over Voltage Protection
Short Circuit Protection
110 to 140%
Hiccup mode
Conducted Emissions
EN55032-B, CISPR22-B, FCC PART15-B
Pass
Radiated Emissions
EN 55032 A;
with external core (King core K5B RC 25x12x15-M in input cable)
Pass
Level B
Input Current Harmonics
EN 61000-3-2
Class D
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Isolation Voltage
Input to Output: (For ITE application)
Input to GND: (Not Applicable For Class II Option)
3000 VAC
1500 VAC
Safety Standard(s)
Approved to the latest edition of the following standards:
CSA/UL60950-1, EN60950-1 and IEC60950-1; Class1 SELV.
Agency Approvals
Nemko, UL, C-UL
CE mark
Complies with LVD Directive
4
Combined output power of main output, fan supply shall not exceed max. Power rating.
Fan supply output voltage tolerance including set point accuracy, line & load regulation is +/-10% and Ripple & noise is less than 10%.
6
Adjustment potentiometer is located on the SMT side of the PCB.
5
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00554_AG
Asia-Pacific
+86 755 298 85888
ABC225 Series
4
PARAMETER
Operating Temperature7
DESCRIPTION / CONDITION
SPECIFICATION
Start-up is guaranteed, with spec deviation, see Fig. 1
-40 to +70°C
-40 to 0°C
Storage Temperature
-40 to +85°C
Cooling
With 13 CFM forced air cooling
With natural convection cooling at 100 to 264 VAC
225 W
Up to 120 W
Relative Humidity
Noncondensing
5% to 95%
Altitude
Operating:
Nonoperating:
16,000 ft.
40,000 ft.
Reliability
MTBF according to Telcordia -SR332-issue 3:
3.37 million hours
Convection load: 120 W up to 40 °C
De-rate between 40-50 °C @ 0.625% per °C
De-rate above 50 °C @ 2.33% per °C
Forced air cooled load: 225 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Figure 1. Derating Curve
Figure 2. Efficiency Graph at 115 VAC
7
Figure 3. Efficiency Graph at 230 VAC
Output ripple can be more than 10% of the output voltage.
[email protected]
ABC225 Series
CONNECTOR
PIN
5
DESCRIPTION/CONDITION
MANUFACTURER / PN
AC Line
Not Fitted
AC Neutral
Molex: 26-60-4030
Mating: 09-50-3031; Pins: 08-50-0106
AC Input Connector
J1
Pin 1
Pin 2
Pin 3
DC Output Connector
J2
Pin 1,2,3
Pin 4,5,6
V1 +VE
V1 - VE
Pin 1
Pin 2
FAN +VE
FAN - VE
Aux (Fan) Output
J3
Screw Terminal (Option 1)
Molex Connector (Option 2)
Molex: 39357 Series or equivalent
Molex: 26-60-4060
Mating: 09-50-3061; Pins: 08-50-0106
AMP :640456-2
Mating: 640440-2
PARAMETER
DESCRIPTION/CONDITION
Weight
200 g approx.
Dimensions
50.8 x 101.6 x 25.4 mm (2 x 4 x 1 inch)
Cooling8
225 W with 13 CFM forced air cooling (refer Mechanical Drawing)
Up to 120 W with natural convection cooling (refer Derating Curve)
Figure 4. Mechanical Drawing – Screw Terminal (Option 1)
8
225 W with 13CFM forced air cooling and 120 W with natural convection cooling at 100 to 264 VAC.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00554_AG
Asia-Pacific
+86 755 298 85888
6
ABC225 Series
Figure 5. Mechanical Drawing – Molex Connector (Option 2)
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
Stand off, used to mount PCB has OD of 5.4 mm max.
2
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
3
Washer, if used, to have dia of 6.5 mm max.
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
[email protected]