DCQAW100 SERIES Up to 90 Watts, Quarter-Brick DC/DC Converters Rev D FEATURES Size: 2.28 x 1.45 x 0.50 inches (57.9 x 36.8 x 12.7 mm) Applications: • Railway Systems • Measurement • Telecom/Datacom • Industry Control Systems • IPC • Automation • Military • Soft Start • Single Outputs • Input Under Voltage Protection • High Efficiency up to 90% • Remote ON/OFF Control • 4:1 Ultra Wide Input Voltage Ranges • No Minimum Load Required • Low Stand-by Power Consumption • Industry Standard Quarter-brick Package • Compliant to RoHS II & Reach • Up to 90 Watts Maximum Output Power • 2250VDC I/O Basic Insulation • Short Circuit, Over Voltage, Over Load, & Over Temp. Protection • UL60950-1, EN60950-1, IEC60950-1, EN45545-2 & EN50155 Safety Approvals • CE Marked • Optional Heatsinks Available (Suffix “HS”) • Threaded (Standard) or Thru-Hole (Optional) Inserts Available • Railway Applications DESCRIPTION The DCQAW100 series of DC/DC power converters provides up to 90 Watts of output power in a 2.28” x 1.45” x 0.5” industry standard quarter-brick package. This series has single output models with 4:1 wide input voltage ranges of 8.5-36VDC, 16.5-75VDC, and 40-160VDC. Some features include high efficiency up to 90%, 2250VDC I/O basic insulation, and remote ON/OFF control. These converters are also protected against input under voltage, short circuit, over voltage, over load, and over temperature conditions. All models are RoHS compliant and have UL60950-1, EN60950-1, IEC60950-1, EN45545-2 and EN50155 safety approvals. Several different options are available for this series including negative logic remote ON/OFF, heatsinks, and thru-hole inserts. MODEL SELECTION TABLE Model Number DCQAW100-24S33 DCQAW100-24S05 DCQAW100-24S12 DCQAW100-24S15 DCQAW100-24S24 DCQAW100-24S30 DCQAW100-24S48 DCQAW100-48S33 DCQAW100-48S05 DCQAW100-48S12 DCQAW100-48S15 DCQAW100-48S24 DCQAW100-48S30 DCQAW100-48S48 DCQAW100-110S33 DCQAW100-110S05 DCQAW100-110S12 DCQAW100-110S15 DCQAW100-110S24 DCQAW100-110S30 DCQAW100-110S48 Input Voltage 24 VDC (8.5 - 36 VDC) 48 VDC (16.5 - 75 VDC) 110 VDC (40 - 160 VDC) Output Voltage 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC 30 VDC 48 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC 30 VDC 48 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC 30 VDC 48 VDC Output Current Min Load Max Load 0mA 25A 0mA 18A 0mA 7.5A 0mA 6A 0mA 3.7A 0mA 3A 0mA 1.8A 0mA 25A 0mA 18A 0mA 7.5A 0mA 6A 0mA 3.7A 0mA 3A 0mA 1.8A 0mA 23A 0mA 17A 0mA 7A 0mA 5.5A 0mA 3.5A 0mA 2.8A 0mA 1.8A Output Ripple & Noise 75mVp-p 75mVp-p 100mVp-p 100mVp-p 200mVp-p 200mVp-p 300mVp-p 75mVp-p 75mVp-p 100mVp-p 100mVp-p 200mVp-p 200mVp-p 300mVp-p 75mVp-p 75mVp-p 100mVp-p 100mVp-p 200mVp-p 200mVp-p 300mVp-p No Load Input Current 25mA 25mA 25mA 25mA 25mA 25mA 25mA 15mA 15mA 15mA 15mA 15mA 15mA 15mA 8mA 8mA 8mA 8mA 8mA 8mA 8mA Output Power 82.5W 90W 90W 90W 88.8W 90W 86.4W 82.5W 90W 90W 90W 88.8W 90W 86.4W 75.9W 85W 84W 82.5W 84W 84W 86.4W Efficiency 88% 89% 89% 89% 89% 89% 88% 88% 89% 89% 90% 90% 90% 90% 88% 89% 89% 89% 89% 89% 89% Maximum Capacitive Load 75,000µF 36,000µF 6250µF 4000µF 1540µF 1000µF 380µF 75,000µF 36,000µF 6250µF 4000µF 1540µF 1000µF 380µF 70,000µF 34,000µF 5830µF 3670µF 1460µF 930µF 380µF NOTES 1. Input Source Impedance: The power modules will operate to specifications without external components, assuming that the source voltage has very low impedance and reasonable input voltage regulation. Highly inductive source impedances can affect the stability of the power module. Since real-world voltage sources have finite impedance, performance is improved by adding an external filter capacitor. - For 24VDC & 48VDC input models we recommend using Nippon Chemi-con KY series, 100µF/100V. - For 110VDC input models we recommend using Ruby-con BXF series, 39µF/200V. 2. If remote sense is not being used, sense pins should connect to the output pins with the same polarity. 3. The DCQAW100 series can only meet EMI Class A or Class B with external components added. Please contact factory for more information. 4. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. - For 24VDC & 48VDC input models we recommend 2pcs of aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V - For 110VDC input models we recommend 3pcs of aluminum electrolytic capacitor (Ruby-con BXF series, 100µF/250V) 5. Both positive logic and negative logic remote ON/OFF control is available. Positive logic remote ON/OFF comes standard; for negative logic remote ON/OFF add the suffix “R” to the model number (Ex: DCQAW100-48S24R). 6. Optional heatsinks available. See page 5 for ordering details. 7. M3 x 0.5 threaded-thru inserts come standard. For Ø.126 thru-hole inserts add the suffix “TH” to the model number (Ex: DCQAW100-48S24TH). Models with thru- hole inserts cannot be equipped with a heatsink. 8. BASE-PLATE GROUNDING: EMI can be reduced when you connect two screw bolts to the shield plane. CAUTION: This power module is not internally fused. An input line fuse must always be used. 09/18/2017 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 1 of 7 DCQAW100 SERIES Up to 90 Watts, Quarter-Brick DC/DC Converters Rev D SPECIFICATIONS: DCQAW100 SERIES All specifications are based on 25°C, Nominal Input Voltage, and Full Load unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ 8.5 16.5 40 24 48 110 Max Unit INPUT SPECIFICATIONS Input Voltage Range Start-Up Voltage Shutdown Voltage Input Surge Voltage (1sec, max.) Input Current Input Filter (See Note 1) 24VDC nominal input models 48VDC nominal input models 110VDC nominal input models 24VDC nominal input models 48VDC nominal input models 110VDC nominal input models 24VDC nominal input models 48VDC nominal input models 110VDC nominal input models 24VDC nominal input models 48VDC nominal input models 110VDC nominal input models No Load 7.3 15.5 33.0 36 75 160 9 18 43 7.7 8.1 15.9 16.3 34.5 36.0 50 100 185 See Table Pi type VDC VDC VDC VDC OUTPUT SPECIFICATIONS Output Voltage Voltage Accuracy Line Regulation Low line to high line at full load Load Regulation No load to full load Voltage Adjustability Remote Sense (See Note 2) Output Power Output Current Minimum Load Maximum Capacitive Load 3.3V & 5V Output Models Others Maximum output deviation is inclusive of remote sense % of Vo (nom) -1.0 -0.1 -0.2 -0.1 -20 See Table +1.0 +0.1 +0.2 +0.1 +10 10 See Table See Table % % % % % 0 Minimum input and constant resistive load Measured with a 22µF/25V X7R MLCC Measured with a 22µF/25V X7R MLCC Ripple & Noise (20MHz BW) Measured with a 4.7µF/50V X7R MLCC Measured with a 2.2µF/100V X7R MLCC Transient Response Recovery Time 25% load step change 3.3V & 5V Output Models 12V & 15V Output Models 24V & 30V Output Models 48V Output Models Start-Up Time Power Up Remote On/Off Constant resistive load Temperature Coefficient -0.02 % See Table 75 100 200 300 250 75 100 75 100 +0.02 mVp-p µs ms %/°C PROTECTION Short Circuit Protection Over Load Protection Over Voltage Protection Over Temperature Protection Continuous, automatic recovery 110 140 % 115 130 % +110 °C % of rated Iout; hiccup mode % of Vo (nom); hiccup mode GENERAL SPECIFICATIONS Efficiency Switching Frequency Nominal input voltage and full load 1 minute (reinforced insulation) 1 minute (basic insulation) 500VDC Isolation Voltage Isolation Resistance Isolation Capacitance 110VDC nominal Input to Output input models Input/Output to Base-plate Input to Output Others Input/Output to Base-plate 270 3000 1500 2250 2250 1 See Table 300 330 kHz VAC VAC VDC VDC GΩ pF 1500 REMOTE ON/OFF (See Note 5) Positive Logic (standard) Referenced to –Input pin Negative Logic (optional) Referenced to –Input pin Input Current of Remote Control Pin Nominal Vin Remote OFF State Input Current Nominal Vin 09/18/2017 DC/DC ON DC/DC OFF DC/DC ON DC/DC OFF -0.5 Open or 3~12 VDC Short or 0~1.2VDC Short or 0~1.2 VDC Open or 3~12VDC 1 3 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] mA mA Page 2 of 7 Rev D DCQAW100 SERIES Up to 90 Watts, Quarter-Brick DC/DC Converters SPECIFICATIONS: DCQAW100 SERIES All specifications are based on 25°C, Nominal Input Voltage, and Full Load unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min ENVIRONMENTAL SPECIFICATIONS Operating Base-Plate Temperature Storage Temperature Range Thermal Impedance (See Note 6) Relative Humidity Thermal Shock Shock Vibration MTBF Typ -40 -55 Without Heatsink Vertical direction by natural With 0.24” Height Heatsink convection (20LFM) With 0.5” Height Heatsink Mounted on 2U iron base-plate 9 7.1 5.5 2.8 5 MIL-HDBK-217F, Full load Max Unit +105 +125 °C °C °C/W 95 % RH MIL-STD-810F EN61373, MIL-STD-810F EN61373, MIL-STD-810F 507,000 hours PHYSICAL SPECIFICATIONS Weight 2.26oz (64g) 2.28in x 1.45in x 0.50in (57.9mm x 36.8mm x 12.7 mm) Aluminum base-plate with plastic case Silicon (UL94-V0) Dimensions (L x W x H) Case Material Potting Material SAFETY & EMC CHARACTERISTICS Safety Approvals EMI (See Note 3) EN55011, EN55032 ESD EN61000-4-2 Radiated Immunity Fast Transient (See Note 4) EN61000-4-3 EN61000-4-4 Surge (See Note 4) EN61000-4-5 Conducted Immunity Power Frequency Magnetic Field EN61000-4-6 EN61000-4-8 IEC60950-1, UL60950-1, EN60950-1, EN50155, EN45545-2 Class A, Class B Air ±8kV Contact ±6kV 20 V/m ±2kV EN55024: ±2kV EN50155: ±2kV 10 Vrms 100A/m continuous; 1000A/m 1 sec Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A CHARACTERISTIC CURVES DCQAW100-24S05 Derating Curve DCQAW100-24S05 Derating Curve w/ 0.24” Heatsink DCQAW100-24S05 Efficiency vs Input Voltage DCQAW100-24S05 Efficiency vs Output Load 09/18/2017 DCQAW100-24S05 Derating Curve w/ 0.5” Heatsink Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 3 of 7 DCQAW100 SERIES Up to 90 Watts, Quarter-Brick DC/DC Converters Rev D OUTPUT VOLTAGE ADJUSTMENT Output is adjustable for 10% trim up or -20% trim down of nominal output voltage by connecting an external resistor between the TRIM pin and either the +SENSE or -SENSE pins. With an external resistor between the TRIM and -SENSE pin, the output voltage set decreases. With an external resistor between the TRIM and +SENSE pin, the output voltage set point increases. Maximum output deviation is +10% inclusive of remote sense. The external Trim resistor needs to be at least 1/8W of rated power. Trim Up Equation 5.11VOUT(100 + ∆%) (511+ 10.22∆%) RU = − KΩ ∆% 1.225∆% Trim Down Equation 511 RD = − 10.22KΩ ∆% TRIM UP 3.3V Output Models ΔV (%) 1 Vout (V) 3.333 RU (kΩ) 869.117 2 3.366 436.331 3 3.399 292.07 4 3.432 219.939 5 3.465 176.66 6 3.498 147.808 7 3.531 127.198 8 3.564 111.742 9 3.597 99.72 10 3.630 90.103 5V Output Models ΔV (%) 1 Vout (V) 5.05 RU (kΩ) 1585.35 2 5.10 797.994 3 5.15 535.542 4 5.20 404.316 5 5.25 325.58 6 5.30 273.09 7 5.35 235.596 8 5.40 207.476 9 5.45 185.605 10 5.50 168.109 12V Output Models ΔV (%) 1 Vout (V) 12.12 RU (kΩ) 4534.55 2 12.24 2287.19 3 12.36 1538.08 4 12.48 1163.52 5 12.60 938.78 6 12.72 788.956 7 12.84 681.939 8 12.96 601.676 9 13.08 539.25 10 13.20 489.309 15V Output Models ΔV (%) 1 Vout (V) 15.15 RU (kΩ) 5798.49 2 15.30 2925.42 3 15.45 1967.73 4 15.60 1488.89 5 15.75 1201.58 6 15.90 1010.04 7 16.05 873.229 8 16.20 770.619 9 16.35 690.812 10 16.50 626.966 24V Output Models ΔV (%) 1 Vout (V) 24.24 RU (kΩ) 9590.32 2 24.48 4840.11 3 24.72 3256.7 4 24.96 2465 5 25.20 1989.98 6 25.44 1673.3 7 25.68 1447.1 8 25.92 1277.45 9 26.16 1145.5 10 26.40 1039.94 30V Output Models ΔV (%) 1 Vout (V) 30.3 RU (kΩ) 12118.2 2 30.6 6116.57 3 30.9 4116.02 4 31.2 3115.74 5 31.5 2515.58 6 31.8 2115.47 7 32.1 1829.68 8 32.4 1615.33 9 32.7 1448.62 10 33 1315.25 48V Output Models ΔV (%) 1 Vout (V) 48.48 RU (kΩ) 19701.9 2 48.96 9945.94 3 49.44 6693.96 4 49.92 5067.97 5 50.40 4092.38 6 50.88 3441.99 7 51.36 2977.42 8 51.84 2628.99 9 52.32 2357.99 10 52.80 2141.19 TRIM DOWN 09/18/2017 All models ΔV (%) RD (kΩ) 1 500.78 2 245.28 3 160.113 4 117.53 5 91.98 6 74.947 7 62.78 8 53.655 9 46.558 10 40.88 ΔV (%) RD (kΩ) 11 36.235 12 32.363 13 29.088 14 26.28 15 23.847 16 21.718 17 19.839 18 18.169 19 16.675 20 15.33 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 4 of 7 Rev D DCQAW100 SERIES Up to 90 Watts, Quarter-Brick DC/DC Converters MECHANICAL DRAWING PIN 1 2 3 4 5 6 7 8 DEFINE - Vin Ctrl + Vin - Vout - Sense Trim + Sense + Vout DIAMETER 0.04 Inch 0.04 Inch 0.04 Inch 0.06 Inch 0.04 Inch 0.04 Inch 0.04 Inch 0.06 Inch Notes: 1. All dimensions in inch [mm] 2. Tolerance :x.xx±0.02 [x.x±0.5] x.xxx±0.01 [x.xx±0.25] 3. Pin pitch tolerance ±0.01 [0.25] 4. Pin dimension tolerance ±0.004[0.10] 5. The screw locked torque:MAX 3.5kgf-cm [0.34N-m] RECOMMENDED PAD LAYOUT Notes: All dimensions in inch[mm] Pad size(lead free recommended) Through hole 1.2.3.5.6.7: ∅0.051[1.30] Through hole 4.8: ∅0.075[1.90] Through hole of mounting: ∅0.126[3.20] Top view pad 1.2.3.5.6.7: ∅0.064[1.63] Top view pad 4.8: ∅0.094[2.38] Top view pad of mounting:Groove R0.065[1.65]L0.157[4.00] Bottom view pad 1.2.3.5.6.7: ∅0.102[2.60] Bottom view pad 8: ∅0.150[3.80] Bottom view pad 4: ∅0.130[3.30] Bottom view pad of mounting:Groove R0.065[1.65]L0.252[6.40] 09/18/2017 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 5 of 7 DCQAW100 SERIES Up to 90 Watts, Quarter-Brick DC/DC Converters Rev D FUSE CONSIDERATION This power module operates in a variety of thermal environments. However, sufficient cooling should be provided to help ensure reliable operation of the unit. Heat is removed by conduction, convection, and radiation to the surrounding environment. Proper cooling can be verified by measuring the point as the figure below. The temperature at this location should not exceed 105ºC. When operating, adequate cooling must be provided to maintain the test point temperature at or below 105ºC. Although the maximum point temperature of the power modules is 105ºC, you can limit this temperature to a lower value for extremely high reliability. ■ Thermal test condition with vertical direction by natural convection (20LFM). ■ The iron base-plate dimension is 19” x 3.5” x 0.063” (the height is EIA standard 2U). ■ The heat-sink is optional and P/N: 7G-0029B-F, 7G-0030B-F. 7G-0031B-F, 7G-0032B-F BASE PLATE THERMAL CONSIDERATION This power module is not internally fused. An input line fuse must always be used. This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of sophisticated power architecture. To maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. Input line fuse suggestions are below: Model 24VDC nominal input models 48VDC nominal input models 110VDC nominal input models Fuse Rating (A) 20A 10A 4A Fuse Type Fast-Acting Fast-Acting Slow-Blow Table is based on the information provided in this data sheet on inrush energy and maximum DC input current at low Vin. HEATSINK OPTIONS Vertical Fin Orientation (Suffix Options: H2, H3) Horizontal Fin Orientation (Suffix Options: H, H1) Note: Models with thru-hole inserts cannot be equipped with a heatsink Note: Models with thru-hole inserts cannot be equipped with a heatsink 09/18/2017 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 6 of 7 DCQAW100 SERIES Up to 90 Watts, Quarter-Brick DC/DC Converters Rev D MODEL NUMBER SETUP 48 S 05 R H (1) Output Power Input Voltage Output Quantity Output Voltage Remote ON/OFF Hole Thread & Heatsink Options 100 100 Watts : 24: 8.5~36 VDC DCQAW 100 Series Name - S: Single Output 48: 16.5~75 VDC 33: 3.3 VDC None: Positive Logic None: 05: 5 VDC 110: 40~160 VDC 12: 12 VDC R: Negative Logic M3x0.5 Threaded-thru Inserts TH: Ø.126 Thru-hole Inserts (1) H: 0.24” Horizontal Heatsink 15: 15 VDC H1: 0.5” Horizontal Heatsink 24: 24 VDC H2: 0.24” Vertical Heatsink 30: 30 VDC H3: 0.5” Vertical Heatsink 48: 48 VDC (1) Models with thru-hole inserts cannot be equipped with a heatsink. COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 09/18/2017 (603)778-2300 (888)597-9255 (603)778-9797 [email protected] www.wallindustries.com 37 Industrial Drive Exeter, NH 03833 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 7 of 7