Copal ET130M10-Z Standard size toggle switch Datasheet

ET
Standard Size Toggle Switch
ET
RoHS Compliant
■ Introduction
The ET series is Copalʼs standard size high capacity
toggle switch. The ET series are available in various
current rating, switching functions, and terminals.
The housing is made of self-extinguishing phenol
resin which has excellent heat resistance, arc
resistance, and tracking resistance. The contacts are
designed to eliminate chattering and bouncing to
prevent insulation deterioration.
■Part Numbering
E
T
2
Series code Actuator shape No. of poles
Fig.
No. of poles
1
2
3
4
6
1 pole
2 poles
3 poles
4 poles
6 poles
Fig.
25
K
Current
Swiching function
AC125V AC250V
12 − Z
Terminal styles
AC125V AC250V
Fig.
03
3A
−−
15
15A
10A
05
5A
3A
20
20A
12A
06
6A
(2A)
25
25A
15A
10
10A
(7A)
30
30A
(25A)
Fig.
Terminal style
None
TAB # 250
10
Screw Terminal
12
Solder Terminal
13
Plate Connect SolderTerminal
32
Solder Terminal
1 pole 2 poles
4 poles
3 poles 6 poles
A
K
B
L
C
M
D
N
E
P
F
R
G
S
H
T
Key way
ON
ON
OFF
ON
ON
ON
(ON)
ON
Key way
−−
−−
−−
−−
OFF
−−
OFF
OFF
Key way
OFF
(OFF)
(ON)
ON
ON
(ON)
(ON)
(ON)
■Terminal Style and Dimentions
TAB # 250
(Style:−)
Screw Terminal(Style:10)
M3.5 × 0.6
M4 × 0.7
M4.5 × 0.75
ET115・215 Type ET120・220 Type ET125・225・230 Type
(ON)
and
(OFF)
:Momentary.
7SLHZLYLMLY[V7MVY*VTTVU:WLJPÄJH[PVUZ
Solder Terminal
Style:12
Style:32
Solder Terminal
(Style:12・13) ET103 □12 Type ET103 □ 32 Type
ET206□12
ET Series Selection Table
Part No.
Appearance
No. of
poles
Rating
Switching function
Terminal style
Page
SolderTerminal
Solder
ET103
1
AC125V
3A
ON
ON
−
OFF
−
ON
(Cut two-wire)
419
SolderTerminal
Solder
ET105
419
1
AC125V
AC250V
ET205
5A
3A
ON
−
OFF
ON
−
ON
ON − OFF − ON
421
2
ET110
1
ET210
2
ET115
1
OFF TAB # 250
−
ON
ON
−
ON
ON − OFF − ON
AC125V 10A
AC250V 7A
(ON)
−
ON
(ON)− OFF −(ON)
ON − OFF −(ON)
Screw
Terminal(M3.5×0.6)
Screw(M3.5×0.6)
ON − ON − OFF
AC125V 10A
420
422
420
SolderTerminal
Solder
ET215
2
ET315
3
ET415
OFF
−
ON
−
ON
(OFF)
−
OFF
(ON) Solder
SolderTerminal
−
ON
ON
AC125V 15A
AC250V 10A
ON − OFF − ON
−
ON
(ON)
(ON)− OFF −(ON)
ON − OFF −(ON)
422
424
426
4
ET415
Plate type
ET120
1
ET125
1
OFF TAB # 250
−
ON
ON
−
ON
ON − OFF − ON
AC125V 20A
AC250V 12A
(ON)
−
ON
(ON)− OFF −(ON)
Screw(M4.5×0.75)
ON − OFF −(ON) Screw Terminal(M4.5×0.6)
421
AC125V 25A
AC250V 15A
ET225
2
420
ON
−
OFF
ON
−
ON
ON − OFF − ON
SolderTerminal
Solder
423
Part No.
Appearance
ET325
No. of
poles
Rating
Switching function
Solder Terminal
Solder
3
AC125V 25A
AC250V 15A
ET425
ET206
ET220
Terminal style
2
424
ON
−
OFF
ON
−
ON
ON − OFF − ON
427
4
2
Page
AC125V
6A
ON
−
OFF
AC125V
AC250V
6A
2A
ON
−
ON
Solder
Solder
Terminal
421
OFF
−
ON
−
ON
(OFF)
−
OFF
(ON)
−
ON
ON
AC125V 20A
AC250V 12A
ON − OFF − ON
−
ON
(ON)
(ON)− OFF −(ON)
ON − OFF −(ON)
TAB # 250
Screw(M4×0.7)
Screw
Terminal(M4×0.7)
423
Solder
Solder Terminal
Screw
Terminal(M4.5×0.75)
Screw(M4.5×0.75)
ET230
423
2
AC125V 30A
AC250V 25A
ET330
3
ET310
3
Solder
Solder
Terminal
425
TAB # 250
AC125V 10A
AC250V 7A
ET410
ON
−
OFF
ON
−
ON
ON − OFF − ON
ON
−
OFF
ON
−
ON
ON − OFF − ON
Solder
Solder
Terminal
424
425
4
ON
−
(ON)
(ON)− OFF −(ON)
ON − OFF −(ON)
ET410
Plate type
ET420
Solder Solder
Terminal
426
4
AC125V 20A
AC250V 12A
ET420
Plate type
ON
−
OFF
ON
−
ON
ON − OFF − ON
427
ET610N
Plate type
6
AC125V 10A
AC250V 7A
ON
−
ON
427
ET620N
Plate type
6
AC125V 20A
AC250V 12A
ON
−
ON
428
● Ratings are based on resistance load.
● Refer to P.428 for UL-recognized and CSA, PSEJLY[PÄLKWYVK\J[Z
(ON)
and
(OFF)
:Momentary.
ET
■Panel Cut-Out Dimensions
●Refer to P.429 for a list of accessories.
Panel thickness : 5.5mm max.
Note : Panel thickness should be 5.5 mm max. unless
otherwise specified.
With Locking Ring
Without Locking Ring
ET103□32(1 pole)
Key way
Switching
function
Key way
Key way
Part No.
M12×1
(1)(4)
(3)(6)
Terminal numbers are shown on the bottom of the switch.
★ ET103A32−Z
ON
−
OFF
Connecting terminals
1−4
−
−
★ ET103V32−Z
ON
−
ON
Connecting terminals
1−4
−
3−6
Terminal pins No.3 and No.6 are not available in switches with
Switching Function “A”.
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET103A32
AC1500V
30mΩ Max.
ET103V32 AC125V 3A (DC2V 100mA) 1 minute
(Cut two-wire)
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
10,000
cycles
ET103□12(1 pole)
Key way
Switching
function
M12×1
Key way
Key way
Part No.
(1)(4)
(3)(6)
Terminal numbers are shown on the bottom of the switch.
ET103A12−Z
ON
−
OFF
Connecting terminals
1−4
−
−
★ ET103V12−Z
ON
−
ON
Connecting terminals
1−4
−
3−6
Terminal pins No.3 and No.6 are not available in switches with
Switching Function “A”.
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET103A12
30mΩ Max.
AC1500V
AC125V 3A
(DC2V 100mA) 1 minute
ET103V12
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
10,000
cycles
L dimensions
Terminal pin No.2 is not available in switches with Switching Function “A”.
ET105□12(1 pole)
Terminal
style
M12×1
Part No.
(1)
ET105A12−Z
ET105D12−Z
ET105E12−Z
(2)
Solder Terminal
24.6±1
24.6±1
24.6±1
(3)
Key way
Key way
Part No.
■:WLJPÄJH[PVUZ
Rating
Key way
Switching
function
Terminal numbers are shown on the bottom of the switch.
Initial contact
resistance
Dielectric
strength
ET105A12
AC125V 5A 20mΩ Max.
AC1500V
ET105D12
AC250V 3A (DC2V 100mA) 1minute
ET105E12
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
☆ ET105A12−Z
ON
−
OFF
Connecting terminals
1−3
−
−
☆ ET105D12−Z
☆ ET105E12−Z
ON
ON
−
OFF
ON
ON
Connecting terminals
2−3
−
2−1
☆:Semi-standard products.
★:Made to order products.
ET
Terminal pin No.2 is not available in switches with Switching
Function “A”.
ET110(1 pole)
L dimensions
Part No.
M12×1
1
0.5
ET110A■・D■−Z
ET110E■−Z
ET110F■−Z
ET110G■・H■−Z
29
2
3
Switching
function
0.5
ET110A■−Z
Connecting terminals
■:WLJPÄJH[PVUZ
ET110A■
ET110D■
ET110E■
ET110F ■
ET110G■
ET110H■
Initial contact
resistance
Dielectric
strength
AC125V 10A
AC250V 7A 20mΩ Max.
AC1500V
AC125V 10A(DC2V 100mA) 1 minute
Insulation
resistance
Electrical
life
30,000
cycles
100MΩ Min.
(DC500V)
20,000
cycles
AC250V 7A
ET115(1 pole)
TAB#250
−
−
27.6±1
27.6±1
Key way
ScrewTerminal Solder Terminal
−
−
−
25.4±1
Key way
24.6±1
24.6±1
24.6±1
24.6±1
Key way
Part No.
Terminal numbers are shown on the bottom of the switch.
Rating
Terminal
style
Terminal pin No.2 is not available in switches with
Switching Function “A”, “B”, or “C”.
OFF
−
−
−
OFF
−
OFF
OFF
ON
ON
(ON)
(ON)
(ON)
Connecting terminals
−
2−1
2−3
■:Refer to “Table of Part Numbers” on P.428 for a full list of part numbers.
L dimensions
Terminal
style
ET115A■・D■−Z
ET115E■−Z
ET115B■−Z
ET115C■・F〜H■−Z
0
−
ET110D■−Z
ON
ET110E■−Z
ON
ET110F■−Z
ON
ET110G■−Z (ON)
ET110H■−Z
ON
Part No.
29
ON
1−3
Switching
function
TAB#250
27.6
27.6±1
−
−
±1
Key way
ScrewTerminal Solder Terminal
25.4±1
25.4±1
−
25.4±1
Key way
24.6±1
24.6±1
24.6±1
24.6±1
Key way
0
Part No.
ET115A■−Z
ET115B■−Z
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
ET115A■
ET115D■
ET115E■
ET115B■
ET115C■
ET115F ■
ET115G■
ET115H■
Initial contact
resistance
Dielectric
strength
Insulation
resistance
Electrical
life
AC125V 15A
AC250V 10A
30,000
cycles
20mΩ Max.
AC1500V
AC125V 15A(DC2V 100mA) 1minute
AC250V 10A
100MΩ Min.
(DC500V)
20,000
cycles
Terminal pin No.2 is not available in switches with
Switching Function “A”.
ET120(1 pole)
ON
ON
−
−
Connecting terminals
1−3
−
−
ET115C■−Z
OFF
−
(ON)
Connecting terminals
−
−
1−3
−
OFF
−
OFF
OFF
ON
ON
(ON)
(ON)
(ON)
−
2−1
ET115D■−Z
ON
ET115E■−Z
ON
ET115F■−Z
ON
ET115G■−Z (ON)
ET115H■−Z
ON
Connecting terminals
■:Refer to “Table of Part Numbers” on P.428 for a full list of part numbers.
L dimensions
Terminal
style
Part No.
29
0
ET120A■・D■−Z
ET120F■〜H■−Z
Switching
function
0
Connecting terminals
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
Insulation
resistance
Electrical
life
(ON)
:Momentary.
100MΩ Min.
(DC500V)
20,000
cycles
■ shows the terminal style “(blank)”, “10”, or “12”.
−
27.6±1
Key way
ScrewTerminal Solder Terminal
−
27.8±1
Key way
24.6±1
24.6±1
Key way
ON
−
OFF
1−3
−
−
−
−
OFF
OFF
ON
(ON)
(ON)
(ON)
−
2−1
ET120D■−Z
ON
ET120F■−Z
ON
ET120G■−Z (ON)
ET120H■−Z
ON
Connecting terminals
ET120A■ AC125V 20A
ET120D■ AC250V 12A 20mΩ Max.
AC1500V
ET120F■ AC125V 20A(DC2V 100mA) 1 minute
ET120G■
ET120H■ AC250V 12A
TAB#250
Part No.
ET120A■−Z
Terminal numbers are shown on the bottom of the switch.
2−3
OFF
(OFF)
2−3
■:Refer to “Table of Part Numbers” on P.428 for a full list of part numbers.
ET
Terminal pin No.2 is not available in switches with Switching
Function “A”.
ET125(1 pole)
L dimensions
Terminal
style
Part No.
ET125A■−Z
ET125D■−Z
ET125E■−Z
ScrewTerminal Solder Terminal
27.6±1
28.8±1
24.6±1
−
28.8±1
24.6±1
29
0.5
M12×1
TAB#250
Switching
function
ET125A■−Z
Connecting terminals
Terminal numbers are shown on the bottom of the switch.
ET125D■−Z
ET125E■−Z
■:WLJPÄJH[PVUZ
Initial contact
resistance
Dielectric
strength
ET125A■
AC125V 25A 20mΩ Max.
AC1500V
ET125D■
AC250V 15A(DC2V 100mA) 1minute
ET125E■
ET205(2 poles)
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
Key way
Key way
Part No.
0.5
Rating
Key way
Connecting terminals
ON
−
OFF
1−3
−
−
ON
ON
−
OFF
ON
ON
2−3
−
2−1
■:Refer to “Table of Part Numbers” on P.428 for a full list
of part numbers.
Terminal pins No.2 and No.5 are not available in switches with
Switching Function “K”.
Switching
function
Key way
Key way
Key way
Part No.
★ ET205K12−Z
ON
24
0.5
Connecting terminals 1−3 4−6
★ ET205N12−Z
★ ET205P12−Z
0.
Key Way
ON
ON
Connecting terminals 2−3 5−6
−
OFF
−
−
−
OFF
ON
ON
−
2−1 5−4
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET205K12
AC125V 5A 20mΩ Max.
AC1500V
ET205N12
AC250V 3A(DC2V 100mA) 1 minute
ET205P12
ET206□12(2 poles)
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
Terminal pins No.3 and No.6 are not available in switches
with Switching Function “K”.
Switching
function
Key way
Key way
Key way
Part No.
M12×1
★ ET206K12−Z
ON
Connecting terminals 2−1 5−4
★ ET206N12−Z
ON
Connecting terminals 2−1 5−4
−
OFF
−
−
−
ON
−
2−3 5−6
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
ET206K12 AC125V 6A
Initial contact
resistance
Dielectric
strength
AC1500V
20mΩ Max.
AC125V 6A(DC2V 100mA) minute
ET206N12
AC250V 2A
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
10,000
cycles
■ shows the terminal style “(blank)”, “10”, or “12”.
☆:Semi-standard products.
★:Made to order products.
ET
ET210(2 poles)
Terminal pins No.2 and No.5 are not available in switches
with Switching Function “K”.
L dimensions
Terminal
style
Part No.
ET210K■・N■−Z
ET210P■−Z
ET210R■〜T■−Z
ET210PA −Z
24
0.5
M12×1
Switching
function
0.5
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
ET210K■
ET210N■
ET210P■
ET210R■
ET210S■
ET210T■
ET210PA12
Initial contact
resistance
Dielectric
strength
AC125V 10A
AC250V 7A
AC1500V
20mΩ Max.
AC125V 10A(DC2V 100mA) 1 minute
AC250V 7A
Insulation
resistance
Electrical
life
30,000
cycles
100MΩ Min.
(DC500V)
ET215(2 poles)
Key way
28.4±1
28.4±1
28.4±1
−
Key way
27.6±1
27.6±1
27.6±1
27.6±1
Key way
−
OFF
Connecting terminals 1−3 4−6
−
−
ET210N■−Z
ON
ET210P■−Z
ON
ET210R■−Z
ON
ET210S■−Z (ON)
ET210T■−Z
ON
−
OFF
−
OFF
OFF
ON
ON
(ON)
(ON)
(ON)
Connecting terminals 2−3 5−6
−
2−1 5−4
ON
OFF
5−6
−
★ ET210PA12−Z
ON
ON
Connecting terminals 2−3 5−6
20,000
cycles
AC125V 10A
30.6±1
30.6±1
30.6±1
−
ScrewTerminal Solder Terminal
Part No.
ET210K■−Z
Rating
TAB#250
■:Refer to “Table of Part Numbers” on P.428 for a full list
of part numbers.of part numbers.
Terminal pins No.2 and No.5 are not available in switches with
Switching Function “K”, “L”, or “M”.
L dimensions
Terminal
style
Part No.
0.5
ET215K■・N■−Z
ET215P■−Z
ET215 L・M
R〜T ■−Z
24
Switching
function
TAB#250
30.6±1
30.6±1
−
Key way
ScrewTerminal Solder Terminal
28.4±1
28.4±1
28.4±1
Key way
27.6±1
27.6±1
27.6±1
Key way
Part No.
0.5
ET215K■−Z
ET215L■−Z
Connecting terminals 1−3 4−6
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
ET215K■
ET215N■
ET215P ■
ET215L ■
ET215M■
ET215R■
ET215S■
ET215T■
Dielectric
strength
Insulation
resistance
30,000
cycles
AC125V 15A
AC250V 10A
20mΩ Max.
AC1500V
AC125V 15A(DC2V 100mA) 1 minute
AC250V 10A
(ON)
and
(OFF)
:Momentary.
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
■ shows the terminal style “(blank)”, “10”, or “12”.
OFF
(OFF)
−
−
−
(ON)
−
−
1−3 4−6
ET215N■−Z
ON
ET215P■−Z
ON
ET215R■−Z
ON
ET215S■−Z (ON)
ET215T■−Z
ON
−
OFF
−
OFF
OFF
ON
ON
(ON)
(ON)
(ON)
Connecting terminals 2−3 5−6
−
2−1 5−4
Connecting terminals
Initial contact
resistance
−
−
OFF
ET215M■−Z
Rating
ON
ON
■:Refer to “Table of Part Numbers” on P.428 for a full list
of part numbers.of part numbers.
ET
ET220(2 poles)
Terminal pins No.2 and No.5 are not available in switches with
Switching Function “K”, “L”, or “M”.
L dimensions
Terminal
style
Part No.
ET220K■・N■−Z
ET220P■−Z
ET220R■〜T■−Z
ET220M■−Z
M12×1
Switching
function
TAB#250
−
−
30.6±1
−
ScrewTerminal Solder Terminal
−
−
30.8±1
−
Key way
Key way
27.6±1
27.6±1
27.6±1
27.6±1
Key way
Part No.
ET220K■−Z
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
ET220K■
ET220N■
ET220P■
ET220L ■
ET220M■
ET220R■
ET220S■
ET220T■
Initial contact
resistance
Dielectric
strength
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
AC125V 20A
AC250V 12A
AC1500V
20mΩ Max.
AC125V 20A(DC2V 100mA) 1 minute
AC250V 12A
ET225(2 poles)
ON
Connecting terminals 1−3 4−6
−
OFF
−
−
ET220M■−Z
OFF
−
(ON)
Connecting terminals
−
−
1−3 4−6
ET220N■−Z
ON
ET220P■−Z
ON
ET220R■−Z
ON
ET220S■−Z (ON)
ET220T■−Z
ON
−
OFF
−
OFF
OFF
ON
ON
(ON)
(ON)
(ON)
Connecting terminals 2−3 5−6
−
2−1 5−4
■:Refer to “Table of Part Numbers” on P.428 for a full list
of part numbers.
Terminal pins No.2 and No.5 are not available in switches
with Switching Function “K”.
L dimensions
Terminal
style
Part No.
ET225K■・N■−Z
ET225P■−Z
Switching
function
TAB#250
30.6±1
ScrewTerminal Solder Terminal
31.8±1
Key way
Key way
27.6±1
Key way
Part No.
ET225K■−Z
Terminal numbers are shown on the bottom of the switch.
ET225N■−Z
ET225P■−Z
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET225K■
AC125V 25A 20mΩ Max.
AC1500V
ET225N■
AC250V 15A(DC2V 100mA) 1 minute
ET225P■
ET230(2 poles)
Insulation
resistance
100MΩ Min.
(DC500V)
ON
Connecting terminals 1−3 4−6
Electrical
life
20,000
cycles
ON
ON
Connecting terminals 2−3 5−6
−
OFF
−
−
−
OFF
ON
ON
−
2−1 5−4
■:Refer to “Table of Part Numbers” on P.428 for a full list
of part numbers.
Terminal pins No.2 and No.5 are not available in switches
with Switching Function “K”.
Switching
function
Key way
Key way
Key way
Part No.
★ ET230N■−Z
★ ET230P■−Z
M12×1
ON
ON
Connecting terminals 2−3 5−6
−
OFF
ON
ON
−
2−1 5−4
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET230N10 AC250V 25A 20mΩ Max. AC1500V
ET230P10 AC125V 30A(DC2V 100mA) 1minute
(ON)
:Momentary.
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
■ shows the terminal style “(blank)”, “10”, or “12”.
★:Made to order products.
ET
ET310(3 poles)
Terminal pins No.2, No.5, and No.8 are not available in
switches with Switching Function “A”.
L dimensions
Terminal
style
Part No.
ET310A■−Z
ET310D■−Z
ET310E■−Z
M12×1
Switching
function
TAB#250
ScrewTerminal Solder Terminal
34±2
36.4±1
Key way
−
Key way
29.1±1
Key way
Part No.
ET310A■−Z
Terminal numbers are shown on the bottom of the switch.
Connecting terminals
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET310A■
AC125V 10A 20mΩ Max.
AC1500V
ET310D■
AC250V 7A(DC2V 100mA) 1minute
ET310E■
ET315□12(3 poles)
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
ET310D■−Z
ET310E■−Z
Connecting terminals
ON
1−3 4−6
7−9
ON
ON
2−3 5−6
8−9
−
OFF
−
−
−
OFF
ON
ON
2−1 5−4
8−7
−
■:Refer to “Table of Part Numbers” on P.428 for a full list
of part numbers.
Terminal pins No.2, No.5, and No.8 are not available in
switches with Switching Function “A”.
Switching
function
Key way
Key way
Key way
Part No.
★ET315A12−Z
Connecting terminals
M12×1
★ET315D12−Z
★ET315E12−Z
★ET315F12−Z
★ET315G12−Z
★ET315H12−Z
Terminal numbers are shown on the bottom of the switch.
Connecting terminals
■:WLJPÄJH[PVUZ
Rating
ET315A12
ET315D12
ET315E12
ET315F12
ET315G12
ET315H12
Initial contact
resistance
Dielectric
strength
AC125V 15A
AC250V 10A 20mΩ Max.
AC1500V
AC125V 15A(DC2V 100mA) 1minute
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
ON
1−3 4−6
7−9
ON
ON
ON
(ON)
ON
2−3 5−6
8−9
−
OFF
−
−
−
OFF
−
OFF
OFF
ON
ON
(ON)
(ON)
(ON)
2−1 5−4
8−7
−
AC250V 10A
ET325□12(3 poles)
Terminal pins No.2, No.5, and No.8 are not available in
switches with Switching Function “A”.
Switching
function
Key way
Key way
Key way
Part No.
★ET325A12−Z
M12×1
Connecting terminals
★ET325D12−Z
★ET325E12−Z
Connecting terminals
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET325A12
AC125V 25A 20mΩ Max.
AC1500V
ET325D12
AC250V 15A(DC2V 100mA) 1 minute
ET325E12
★:Made to order products.
(ON)
:Momentary.
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
■ shows the terminal style “(blank)” or “12”.
ON
1−3 4−6
7−9
ON
ON
2−3 5−6
8−9
−
OFF
−
−
−
OFF
ON
ON
2−1 5−4
8−7
−
ET
ET330□12(3 poles)
Terminal pins No.2, No.5, and No.8 are not available in
switches with Switching Function “A”.
L dimensions
Terminal
style
Part No.
ET330A■−Z
ET330D12−Z
ET330E 12−Z
M12×1
Switching
function
TAB#250
ScrewTerminal Solder Terminal
33.9±2
−
Key way
−
Key way
29.1±1
Key way
Part No.
ET330A■−Z
Terminal numbers are shown on the bottom of the switch.
Connecting terminals
☆ET330D12−Z
★ET330E12−Z
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET330A■
AC125V 30A 20mΩ Max.
AC1500V
ET330D12
AC250V 25A(DC2V 100mA) 1minute
ET330E12
ET410□12(4 poles)
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
Connecting terminals
ON
1−3 4−6
7−9
ON
ON
2−3 5−6
8−9
−
OFF
−
−
−
OFF
ON
ON
2−1 5−4
8−7
−
■:Refer to “Table of Part Numbers” on P.428 for a full list
of part numbers.
Terminal pins No.2, No.5, No.8, and No.11 are not available in
switches with Switching Function “K”.
Switching
function
Key way
Key way
Key way
Part No.
★ET410K12−Z
33.5
Connecting terminals
★ET410N12−Z
★ET410P12−Z
★ET410R12−Z
★ET410S12−Z
▲ET410T12−Z
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
ET410K12
ET410N12
ET410P12
ET410R12
ET410S12
ET410T12
Connecting terminals
Initial contact
resistance
Dielectric
strength
AC125V 10A
AC250V 7A 20mΩ Max.
AC1500V
AC125V 10A(DC2V 100mA) 1 minute
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
ON
1−3 4−6
7−9 10−12
ON
ON
ON
(ON)
ON
2−3 5−6
8−9 11−12
−
OFF
−
−
−
OFF
−
OFF
OFF
ON
ON
(ON)
(ON)
(ON)
2−1 5−4
8−7 11−10
−
AC250V 7A
ET410□13(4 poles)
Switching Viewed from part No. and rating marking side
function
Part No.
ON
2−3 5−6
Connecting terminals
8−9 11−12
2-M3×0.5
33.5
★ET410R13−Z
−
−
(ON)
2−1 5−4
8−7 11−10
■Panel Cut-Out Dimensions
(Plate mounting type)
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
ET410R13
Initial contact
resistance
Dielectric
strength
AC125V 10A 20mΩ Max.
AC1500V
AC250V 7A(DC2V 100mA) 1 minute
■ shows the terminal style “(blank)”, “10”, or “12”.
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
(ON)
:Momentary.
▲:Inquiry products. ☆:Semi-standard products. ★:Made to order products.
ET
ET415□12(4 poles)
Terminal pins No.2, No.5, No.8, and No.11 are not available in
switches with Switching Function “K”.
Switching
function
Key way
Key way
Key way
Part No.
★ET415K12−Z
Connecting terminals
★ET415N12−Z
★ET415P12−Z
Connecting terminals
ON
1−3 4−6
7−9 10−12
ON
ON
2−3 5−6
8−9 11−12
−
OFF
−
−
−
OFF
ON
ON
2−1 5−4
8−7 11−10
−
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET415K12
AC125V 15A 20mΩ Max.
AC1500V
ET415N12
AC250V 10A(DC2V 100mA) 1minute
ET415P12
ET415□13(4 poles)
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
Terminal pins No.2, No.5, No.8, and No.11 are not available in
switches with Switching Function “K”.
Switching Viewed from part No. and rating marking side
function
Part No.
★ET415K13−Z
2-M3×0.5
Connecting terminals
★ET415N13−Z
▲ET415P13−Z
Connecting terminals
ON
1−3 4−6
7−9 10−12
ON
ON
2−3 5−6
8−9 11−12
−
OFF
−
−
−
OFF
ON
ON
2−1 5−4
8−7 11−10
−
Terminal numbers are shown on the bottom of the switch.
■Panel Cut-Out Dimensions
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET415K13
AC125V 15A 20mΩ Max.
AC1500V
ET415N13
AC250V 10A(DC2V 100mA) 1minute
ET415P13
ET420□12(4 poles)
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
(Plate mounting type)
Terminal pins No.2, No.5, No.8, and No.11 are not available in
switches with Switching Function “K”.
Switching
function
Key way
Key way
Key way
Part No.
★ET420K12−Z
Connecting terminals
★ET420N12−Z
★ET420P12−Z
Connecting terminals
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Rating
Initial contact
resistance
Dielectric
strength
ET420K12
AC125V 20A 20mΩ Max.
AC1500V
ET420N12
AC250V 12A(DC2V 100mA) 1minute
ET420P12
★:Made to order products.
▲:Inquiry products.
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
ON
1−3 4−6
7−9 10−12
ON
ON
2−3 5−6
8−9 11−12
−
OFF
−
−
−
OFF
ON
ON
2−1 5−4
8−7 11−10
−
ET
ET420□13(4 poles)
Terminal pins No.2, No.5, No.8, and No.11 are not available in
switches with Switching Function “K”.
Switching Viewed from part No. and rating marking side
function
Part No.
★ET420K13−Z
2-M3×0.5
Connecting terminals
★ET420N13−Z
★ET420P13−Z
Connecting terminals
ON
1−3 4−6
7−9 10−12
ON
ON
2−3 5−6
8−9 11−12
−
OFF
−
−
−
OFF
ON
ON
2−1 5−4
8−7 11−10
−
■Panel Cut-Out Dimensions
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Initial contact
resistance
Rating
Dielectric
strength
ET420K13
AC125V 20A 20mΩ Max.
AC1500V
ET420N13
AC250V 12A(DC2V 100mA) 1minute
ET420P13
ET425□12(4 poles)
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
(Plate mounting type)
Terminal pins No.2, No.5, No.8, and No.11 are not available in
switches with Switching Function “K”.
Switching
function
Key way
Key way
Key way
Part No.
★ET425K12−Z
12M×1
Connecting terminals
★ET425N12−Z
★ET425P12−Z
Connecting terminals
ON
1−3 4−6
7−9 10−12
ON
ON
2−3 5−6
8−9 11−12
−
OFF
−
−
−
OFF
ON
ON
2−1 5−4
8−7 11−10
−
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Initial contact
resistance
Rating
Dielectric
strength
ET425K12
AC125V 25A 20mΩ Max.
AC1500V
ET425N12
AC250V 15A(DC2V 100mA) 1minute
ET425P12
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
20,000
cycles
ET610N13(6 poles)
Switching Viewed from part No. and rating marking side
function
Part No.
☆ET610N13−Z
4-M3×0.5
ON
−
ON
−
2−1 5−4
8−7 11−10
14−13 17−16
2−3 5−6
34.5
Connecting terminals 8−9 11−12
14−15 17−18
■Panel Cut-Out Dimensions
Terminal numbers are shown on the bottom of the switch.
(Plate mounting type)
■:WLJPÄJH[PVUZ
Rating
ET610N13
Initial contact
resistance
Dielectric
strength
AC125V 10A 20mΩ Max.
AC1500V
AC250V 7A(DC2V 100mA) 1 minute
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
5,000
cycles
☆:Semi-standard products. ★:Made to order products.
ET
ET620N13(6 poles)
Switching Viewed from part No. and rating marking side
function
Part No.
★ET620N13−Z
4-M3×0.5
ON
34.5
2−3 5−6
Connecting terminals 8−9 11−12
14−15 17−18
−
ON
−
2−1 5−4
8−7 11−10
14−13 17−16
■Panel Cut-Out Dimensions
Terminal numbers are shown on the bottom of the switch.
■:WLJPÄJH[PVUZ
Initial contact
resistance
Rating
ET620N13
(Plate mounting type)
Dielectric
strength
AC125V 20A 20mΩ Max.
AC1500V
AC250V 12A(DC2V 100mA) 1 minute
Insulation
resistance
Electrical
life
100MΩ Min.
(DC500V)
5,000
cycles
■UL・CSA・ / Table of Part Numbers
Terminal Style
TAB terminals
★
★
★
★
★
★
☆
★
Screw terminals ★
★
★
▲
★
★
★
☆
☆
☆
☆
☆
★
★
★
Solder terminals
★
★
★
★
★
★
☆
★
▲
★
★
☆
Part No.
※1.
ET110F−Z
ET110G−Z
★
ET110H−Z
★
ET115A−Z
29.4 ▲
ET115D−Z
★
ET115E−Z
★
ET110G10−Z
★
ET115A10−Z
★
ET115C10−Z
★
ET115D10−Z
ET115E10−Z
★
ET115F10−Z
☆
ET115H10−Z
★
ET103A12−Z 21.0 ★
ET103A32−Z 21.0 ★
ET103V12−Z 21.0 ★
ET103V32−Z
★
ET105A12−Z
★
ET105D12−Z 25.8
ET105E12−Z
☆
ET110A12−Z 25.8 ☆
ET110D12−Z
☆
ET110E12−Z
☆
ET110F12−Z
★
ET110G12−Z
★
ET115A12−Z 25.9 ★
ET115B12−Z
★
ET115C12−Z
☆
ET115D12−Z 25.9 ▲
ET115E12−Z 25.9 ★
ET115F12−Z
☆
ET115G12−Z
★
ET115H12−Z 25.0 ★
ET120A12−Z
ET120D12−Z
★
ET120F12−Z
★
ET120G12−Z
ET120H12−Z
▲
ET125A12−Z 25.9 ★
Part No.
※1.
−
★
ET120G−Z
☆
ET125A−Z
26.6 ★
ET125D−Z
★
ET210S−Z
☆
ET215K−Z
39.3 ★
ET120G10−Z
★
ET125A10−Z
▲
ET125D10−Z
★
−
▲
ET215K10−Z
★
ET215N10−Z
★
ET215P10−Z
★
ET125D12−Z 26.0 ★
ET125E12−Z
★
ET205K12−Z
★
ET205N12−Z
★
ET205P12−Z
☆
ET206K12−Z 26.1
ET206N12−Z 26.3
ET210K12−Z
★
ET210N12−Z 38.0 ☆
ET210P12−Z 37.9 ☆
ET210R12−Z
★
ET210S12−Z
★
ET210T12−Z
★
ET210PA12−Z
★
ET215K12−Z 37.9 ★
ET215L12−Z
★
ET215M12−Z
★
ET215N12−Z 38.1 ★
ET215P12−Z 37.8 ★
ET215R12−Z
★
ET215S12−Z 38.4 ☆
ET215T12−Z
★
ET220K12−Z
★
−
★
ET220M12−Z
★
ET220N12−Z
★
Part No.
※1.
ET215N−Z
40.0
ET215P−Z
39.7 ▲
ET220R−Z
★
ET220S−Z
ET225K−Z
39.4
ET225N−Z
ET215L10−Z
★
ET215R10−Z
★
ET215S10−Z
ET215T10−Z
★
ET220R10−Z 53.6 ★
ET220S10−Z
ET225K10−Z
ET220P12−Z
★
ET220R12−Z
★
ET220S12−Z
▲
ET220T12−Z
★
ET225K12−Z 38.1 ★
ET225N12−Z 38.6 ★
ET225P12−Z
★
ET310A12−Z 54.0 ★
ET310D12−Z 54.6 ▲
ET310E12−Z
★
ET315A12−Z
★
ET315D12−Z 54.7 ★
ET315E12−Z
★
ET315F12−Z
★
ET315G12−Z
★
ET315H12−Z
★
ET325A12−Z
★
ET325D12−Z
★
ET325E12−Z
☆
ET330A12−Z
★
ET330D12−Z 54.2
ET330E12−Z
ET410K12−Z 56.5
ET410N12−Z 57.4
ET410P12−Z
ET410R12−Z 56.5
Part No.
ET225P−Z
ET310E−Z
ET330A−Z
−
−
−
ET225N10−Z
ET225P10−Z
−
ET230N10−Z
ET230P10−Z
−
−
ET410R13−Z
ET410S12−Z
ET410T12−Z
ET415K12−Z
ET415K13−Z
ET415N12−Z
ET415N13−Z
ET415P12−Z
ET415P13−Z
ET420K12−Z
ET420K13−Z
ET420N12−Z
ET420N13−Z
ET420P12−Z
ET420P13−Z
ET425K12−Z
ET425N12−Z
ET425P12−Z
ET610N13−Z
ET620N13−Z
−
−
−
−
−
−
※1.
−
−
−
54.4
56.9
57.6
56.8
55.0
106.0
105.0
−
−
−
−
−
−
(ZZOV^UPU[OLHIV]L[HISLUV[HSSWYVK\J[ZHYL<3YLJVNUPaLKVY*:(JLY[PÄLK7SLHZLJOLJR^P[O`V\YSVJHSZHSLZYLWYLZLU[H[P]LPM`V\OH]LHU`X\LZ[PVUZ
Note: For overseas standards, see P.627.
※1 : Switch mass (g) : includes accessories = hex nut, locking ring, lock washer and terminal screw
★:Made to order products.
☆:Semi-standard products.
▲:Inquiry products.
ET
■Electrical Appliance and Material Safety Law Listed Products
For appliances
Circuit Part No.
For general appliances
For motors
For electronic appliances
For appliances
License number model
AC125V AC250V AC125V AC125V
ET110G10−Z
10A
7A
−
−
41−10290
Circuit Part No.
For general appliances
For electronic appliances
For motors
AC125V AC250V AC125V AC125V
ET115A10−Z
400W
2A
15A
10A
SPST
−
−
ET115C10−Z
400W
ET115D10−Z
2A
ET115E10−Z
SPDT ET115F10−Z
15A
10A
−
ET125D10−Z
15A
ET215L10−Z
15A
10A
ET225K10−Z
25A
−
−
ET125A10−Z
41−15338
ET215K10−Z
41−10665
DPST
ET115H10−Z
ET120G10−Z
25A
41−15368
20A
12A
−
−
41−10463
25A
15A
750W
5A
41−15369
■Standard Accessories
−
Hex Nut
Hex Nut
Lockwasher
Locking Ring
Part No.
140008010235
140008010221
140008030055
140008020065
Dimensions
Nickel plated
Zinc plated
Zinc plated
5A
2A
41−15369
−
−
41−10296
15A
750W
5A
41−15371
−
−
−
41−15370
−
Zinc plated
ET115
ET215
140000080639
140008030057
ET120
ET220
140000080651
140008030058
ET125
ET225
ET230
140000080652
140008030060
《Supplied separately》
ET・8B
Type
Part No.
41−10665
750W
400W
■Optional Accessories
ET
Plate
Part Name
41−15368
《Supplied with switch》
Part Name
Finish
License number model
140008040021
ET
Plate
Waterproof boot
Boot
Bushing
140008040025
Red 140000610335
Gray 140000610334
Black 140000610333
140000610080
140008010244
Dimensions
Red
Red
Black
Black
Type
ET
Part Name
Hex Nut
Part No.
140008010238
⑵ Waterproof boot
■7HJRHNPUN:WLJPÄJH[PVU
①The boot is fixed to the switch with the
built-in screw.
Plastic bag
②The boot cannot be used for platemounting switches.
Dimensions
Chromium
■Handling Precautions
1. :VSKLYPUN:WLJPÄJH[PVUZ
⑴Manual Soldering
Device : Soldering iron
420℃, Max.; 3 seconds, Max.
2.Flux Cleaning
⑴ Solvent : Fluorine or Alcohol type.
⑵ The ET series are not washable. To wash
the PC board, clean the soldering surface
of the PC board with a brush so that the
switch is not exposed to the cleaning
solution.
Optional Accessories
:Optional Accessories.
Similar pages