JZC-22F JZC-22F2 JZC-22F3 CH0050402—2000 20.3×16.8×20.2 JZC-22F 22.5×16.8×20.2 JZC-22F2 20.0×16.0×20.3 JZC-22F3 E158859 VDE 40001299 R9452085 Features Small size, light weight .Low coil power consumption. Switching capacity can reach 20A. PC board mounting. Suitable for household electrical appliance, automation system, electronic equipment, instrument and meter application. TV-5fTV-8 Remote control TV receivers, monitor display, audio equipment high and rushing current application. Ordering Information JZC-22F S C 5 D DC12V 1 2 3 4 5 6 1 Part number:JZC-22F JZC-22F2 JZC-22F3 2 Enclosure:S: Sealed type;F: Dust cover 3 Contact arrangement:A:1A;B:1B;C:1C 4 Contact Rating:7A,12A,15A/120VAC 28DC; 6A,7A/220VAC;6A/250VAC TV-5; (JZC-22F2:20A/125VAC 28VDC;10A/220VAC) ; (JZC-22F3:20A/125VAC 28VDC;16A/277VAC TV-8) 5 Coil power consumption:L:0.36W;D:0.45W 6 Coil rated Voltage(V):DC:3,6,9,12,24,48 Contact Data Contact Arrangement Contact Material Contact Rating Max. Switching Power Max. Switching Voltage Contact Resistance & Voltage drop Operation Electrical life Mechanical 1ASPSTNO 1BSPSTNC 1CSPDT(B-M) AgCdO AgSnO2 resistive:5A,12A,15A,20A/120VAC,28VDC; 3A;6A,7A,10A/220VAC ; inductive:10A/250VAC; 15A/28VDC (rushing current 80A) (JZC-22FT only) lamp:TV-5 note:1) 20A/125VDC,28VDC &10A/220VAC JZC-22F2 only 2) 20A/125V,28VDC,16A/277VAC&TV-8 JZC-22F3 only 420W 1800VA 110VDC 380VAC Max. Switching Current:20A rushing current 80A አ100m item 3.12 of IEC255-7 105 item 3.30 of IEC255-7 107 item 3.31 of IEC255-7 Coil Parameter Dash numbers 003-360 006-360 009-360 012-360 024-360 048-360 003-450 006-450 009-450 012-450 024-450 048-450 Coil voltage VDC Rated Max. 3 6 9 12 24 48 3 6 9 12 24 48 3.9 7.8 11.7 15.6 31.2 62.4 3.9 7.8 11.7 15.6 31.2 62.4 Coil resistance ±10% Pickup voltage VDC(max) (75%of rated voltage ) 25 100 225 400 1600 6400 20 80 180 320 1280 5120 2.25 4.50 6.75 9.00 18.0 36.0 2.25 4.50 6.75 9.00 18.0 36.0 release voltage VDC(min) (10% of rated voltage) 0.3 0.6 0.9 1.2 2.4 4.8 0.3 0.6 0.9 1.2 2.4 4.8 Coil power consumption W Operate Time ms Release Time ms 0.36 15 5 0.45 15 5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 93 www.dblectro.com JZC-22F JZC-22F2 JZC-22F3 Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 100M min (at 500VDC) Item 7 of IEC255-5 50Hz 750VJZC-22F3 :1000V 50Hz 1500V 50Hz 2500VJZC-22F2 &JZC-22F3 100m/s2 11ms 10~55Hz double amplitude 1.5mm 10N 2352 30.5s -40~70JZC-22F3 :85 85% (at 40) 13g . 16g(JZC-22F2) 10g(JZC-22F3) Item 6 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca Qualification inspection: Perform the qualification test as specified in the table Safety approvals Safety approval Load UL&CUR 15A/125VAC,28VDC;TV-5 of IEC255-19-1 and minimum sample size 24. VDE 10A/250VAC 28VDC TüV CCEE 6A/250VAC 6A/250VAC Dimensions (Unit: mm) Mounting (Bottom views) Wiring diagram (Bottom views) Dimensions mm 0.4 0.5 0.7 1.0 1.3 2.0 2.55 3.5 4.5 6.0 12.0 12.2 16.8 20.2 20.3 22.5 NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. Reference Data www.dblectro.com inch 0.016 0.020 0.027 0.039 0.051 0.079 0.100 0.138 0.177 0.236 0.472 0.480 0.661 0.795 0.799 0.866