Current Transducer HLSR-P/SP33 series IPN = 10 ... 50 A Ref: HLSR 10-P/SP33, HLSR 20-P/SP33, HLSR 32-P/SP33, HLSR 40-P/SP33, HLSR 50-P/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Applications ●● Open loop multi-range current transducer ●● AC variable speed and servo motor drives ●● Voltage output ●● Static converters for DC motor drives ●● Galvanic separation between primary and secondary ●● Battery supplied applications ●● Low power consumption ●● Uninterruptible Power Supplies (UPS) ●● Compact design for through-hole PCB mounting ●● Switched Mode Power Supplies (SMPS) ●● Factory calibrated ●● Power supplies for welding applications ●● High bandwidth, very low loss magnetic core. ●● Combiner box ●● MPPT. Special feature Standards ●● Single supply +3.3 V. ●● EN 50178: 1997 Advantages ●● Extremely low profile: h = 12 mm ●● Low foot-print ●● IEC 61010-1: 2010 ●● IEC 61326-1: 2012 ●● UL 508: 2010. ●● Low offset drift Application Domain ●● Over-drivable Vref. ●● Industrial. N°97.J3.13.033.0, N°97.J3.17.033.0, N°97.J3.J3.033.0, N°97.J3.23.033.0, N°97.J3.25.033.0 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 1/12 www.lem.com HLSR-P/SP33 series Absolute maximum ratings Parameter Symbol Unit Value Supply voltage (not destructive) UC V 8 Supply voltage (not entering non standard modes) UC V 6.5 Primary conductor temperature TB °C 120 UESD kV 2 ESD rating, Human Body Model (HBM) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. UL 508: Ratings and assumptions of certification File # E189713 Volume: 2 Section: 5 Standards ●● CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01 ●● UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15 Ratings Parameter Symbol Primary involved potential Unit Value V AC/DC 600 Max surrounding air temperature TA °C 105 Primary current IP A According to series primary current Secondary supply voltage UC V DC 5 Output voltage Vout V 0 to 5 Conditions of acceptability 1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2 environment. 2 - A suitable enclosure shall be provided in the end-use application. 3 - The terminals have not been evaluated for field wiring. 4 - These devices are intended to be mounted on a printed wiring board of end use equipment. The suitability of the connections (including spacings) shall be determined in the end-use application. 5 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the terminals. 6 - Any surface of polymeric housing have not been evaluated as insulating barrier. 7-L ow voltage control circuit shall be supplied by an isolating source (such as a transformer, optical isolator, limiting impedance or electro-mechanical relay). Marking Only those products bearing the UR Mark should be considered to be Listed or Recognized and covered under UL's Follow-Up Service. Always look for the Mark on the product. Page 2/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Insulation coordination Parameter Symbol Unit Value Rms voltage for AC insulation test 50/60 Hz/1 min Ud kV 4.3 Impulse withstand voltage 1.2/50 µs ÛW kV 8 Clearance (pri. - sec.) dCI mm >8 Shortest distance through air Creepage distance (pri. - sec.) dCp mm >8 Shortest path along device body Clearance (pri. - sec.) - mm 8 When mounted on PCB with recommended layout Case material - - V0 Comparative tracking index Comment According to UL 94 600 CTI Application example - - 600 V CAT III PD2 Reinforced insulation, non uniform field according to EN 50178, IEC 61010 Application example - - 1000 V CAT III PD2 Simple insulation, non uniform field according to EN 50178, IEC 61010 Application example - - 600 V CAT III PD2 Symbol Unit Min Ambient operating temperature TA °C −40 105 Ambient storage temperature TS °C −40 105 Mass m g According to UL 508 Environmental and mechanical characteristics Parameter Typ Max Comment 5 Page 3/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Electrical data HLSR 10-P/SP33 At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9). Parameter Symbol Unit Primary nominal rms current IPN A Primary current, measuring range IPM A Number of primary turns NP - 1 Resistance of primary jumper @ TA = 25 °C RP mΩ 0.21 Resistance of primary jumper @ TA = 105 °C RP mΩ 0.29 Supply voltage UC V Current consumption IC mA Reference voltage (output) Vref V 1.63 Reference voltage (input) Vref V 0.5 Vout − Vref V −1.15 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Capacitive loading CL nF 0 6 Electrical offset voltage @ IP = 0 VOE mV −5 5 Electrical offset current referred to primary IOE mA −109 109 Temperature coefficient of Vref TCVref ppm/K −150 150 Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 Temperature coefficient of IOE TCIOE mA/K −1.63 1.63 Theoretical sensitivity Gth mV/A Sensitivity error εG % −0.5 0.5 Output voltage range @ IPM Temperature coefficient of G Min Typ Max 10 −25 3.135 25 3.3 3.465 19 25 1.65 1.67 Internal reference 1.7 External reference 1.15 Over operating temperature range 200 300 series 2 5 series ppm/K −200 200 εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.8 0.8 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.25 0.25 Reaction time @ 10 % of IPN tra µs tr µs BW kHz Output rms voltage noise spectral density 100 Hz … 100 kHz eno µV/√ Hz Output voltage noise DC … 10 kHz DC … 100 kHz DC … 1 MHz Vno mVpp Accuracy @ IPN Vout − Vref −40 °C … 105 °C 460 mV @ IPN 46 TCG Frequency bandwidth (−3 dB) For UC = 3.3 V ±5 % T jumper = 120 °C Linearity error 0 … IPN Response time @ 90 % of IPN Comment Factory adjustment 2 @ 50 A/µs 2.5 @ 50 A/µs 450 16 9 22 40 X % of IPN −1 1 Accuracy @ IPN @ TA = +85 °C X85 °C % of IPN −3.2 3.2 See formula note 1) Accuracy @ IPN @ TA = +105 °C X105 °C % of IPN −3.9 3.9 See formula note 1) Note: 1) Accuracy @ TA (% of IPN) = X + ( TCIOE TCG × (TA –25) + × 100 × (TA –25)). 10000 1000 × IPN Page 4/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Electrical data HLSR 20-P/SP33 At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9). Parameter Symbol Unit Min Primary nominal rms current IPN A Primary current, measuring range IPM A Number of primary turns NP - 1 Resistance of primary jumper @ TA = 25 °C RP mΩ 0.21 Resistance of primary jumper @ TA = 105 °C RP mΩ 0.29 Supply voltage UC V Current consumption IC mA Reference voltage (output) Vref Reference voltage (input) Typ Max Comment 20 −50 50 For UC = 3.3 V ±5 % T jumper = 120 °C 3.135 3.3 19 25 V 1.63 1.65 1.67 Internal reference Vref V 0.5 1.7 External reference Vout − Vref V −1.15 1.15 Over operating temperature range Vref output resistance Rref Ω 130 200 300 series Vout output resistance Rout Ω 2 5 series Capacitive loading CL nF 0 6 Electrical offset voltage @ IP = 0 VOE mV −5 5 Output voltage range @ IPM 3.465 IOE mA −217 217 Temperature coefficient of Vref TCVref ppm/K −150 150 Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 Temperature coefficient of IOE TCIOE mA/K −3.26 3.26 Gth mV/A Electrical offset current referred to primary Theoretical sensitivity Sensitivity error −40 °C … 105 °C 460 mV @ IPN 23 εG % −0.5 0.5 TCG ppm/K −200 200 Linearity error 0 … IPN εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.8 0.8 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.25 0.25 Reaction time @ 10 % of IPN tra µs Temperature coefficient of G Vout − Vref Factory adjustment 2 @ 50 A/µs 2.5 @ 50 A/µs Response time @ 90 % of IPN tr µs Frequency bandwidth (−3 dB) BW kHz Output rms voltage noise spectral density 100 Hz … 100 kHz eno µV/√ Hz Output voltage noise DC … 10 kHz DC … 100 kHz DC … 1 MHz Vno mVpp X % of IPN −1 1 Accuracy @ IPN @ TA = +85 °C X85 °C % of IPN −3.2 3.2 See formula note 1) Accuracy @ IPN @ TA = +105 °C X105 °C % of IPN −3.9 3.9 See formula note 1) Accuracy @ IPN TCG 450 8 6 13 23 TCI Note: 1) Accuracy @ TA (% of IPN) = X + ( 10000 × (TA –25) + 1000OE× I × 100 × (TA –25)). PN Page 5/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Electrical data HLSR 32-P/SP33 At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9). Parameter Symbol Unit Primary nominal rms current IPN A Primary current, measuring range IPM A Number of primary turns NP - 1 Resistance of primary jumper @ TA = 25 °C RP mΩ 0.21 Resistance of primary jumper @ TA = 105 °C RP mΩ 0.29 Supply voltage UC V Current consumption IC mA Reference voltage (output) Vref V 1.63 Reference voltage (input) Vref V 0.5 Vout − Vref V −1.15 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Capacitive loading CL nF 0 6 Electrical offset voltage @ IP = 0 VOE mV −5 5 Electrical offset current referred to primary IOE mA −348 348 Temperature coefficient of Vref TCVref ppm/K −150 150 Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 Temperature coefficient of IOE TCIOE mA/K −5.22 5.22 Theoretical sensitivity Gth mV/A Sensitivity error εG % −0.5 0.5 Output voltage range @ IPM Temperature coefficient of G Min Typ Max 32 -80 3.135 80 3.3 3.465 19 25 1.65 1.67 Internal reference 1.7 External reference 1.15 Over operating temperature range 200 300 series 2 5 series ppm/K −200 200 εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.8 0.8 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.25 0.25 Reaction time @ 10 % of IPN tra µs tr µs BW kHz Output rms voltage noise spectral density 100 Hz … 100 kHz eno µV/√ Hz Output voltage noise DC … 10 kHz DC … 100 kHz DC … 1 MHz Vno mVpp Accuracy @ IPN Vout − Vref −40 °C … 105 °C 460 mV @ IPN 14.375 TCG Frequency bandwidth (−3 dB) For UC = 3.3 V ±5 % T jumper = 120 °C Linearity error 0 … IPN Response time @ 90 % of IPN Comment Factory adjustment 2 @ 50 A/µs 2.5 @ 50 A/µs 450 5 4 10 16 X % of IPN −1 1 Accuracy @ IPN @ TA = +85 °C X85 °C % of IPN −3.2 3.2 See formula note 1) Accuracy @ IPN @ TA = +105 °C X105 °C % of IPN −3.9 3.9 See formula note 1) TCG Note: 1) Accuracy @ TA (% of IPN) = X + ( × (TA –25) + 10000 TCIOE 1000 × IPN × 100 × (TA –25)). Page 6/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Electrical data HLSR 40-P/SP33 At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9). Parameter Symbol Unit Primary nominal rms current IPN A Primary current, measuring range IPM A Number of primary turns NP - 1 Resistance of primary jumper @ TA = 25 °C RP mΩ 0.21 Resistance of primary jumper @ TA = 105 °C RP mΩ 0.29 Supply voltage UC V Current consumption IC mA Reference voltage (output) Vref V 1.63 Reference voltage (input) Vref V 0.5 Vout − Vref V −1.15 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Capacitive loading CL nF 0 6 Electrical offset voltage @ IP = 0 VOE mV −5 5 Electrical offset current referred to primary IOE mA −435 435 Temperature coefficient of Vref TCVref ppm/K −150 150 Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 Temperature coefficient of IOE TCIOE mA/K −6.52 6.52 Theoretical sensitivity Gth mV/A Sensitivity error εG % −0.5 0.5 TCG ppm/K −200 200 Linearity error 0 … IPN εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.8 0.8 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.25 0.25 Reaction time @ 10 % of IPN tra µs 2 @ 50 A/µs Response time @ 90 % of IPN tr µs 2.5 @ 50 A/µs Frequency bandwidth (−3 dB) BW kHz Output rms voltage noise spectral density 100 Hz … 100 kHz eno µV/√ Hz Output voltage noise DC … 10 kHz DC … 100 kHz DC … 1 MHz Vno mVpp X % of IPN −1 1 Accuracy @ IPN @ TA = +85 °C X85 °C % of IPN −3.2 3.2 See formula note 1) Accuracy @ IPN @ TA = +105 °C X105 °C % of IPN −3.9 3.9 See formula note 1) Output voltage range @ IPM Temperature coefficient of G Accuracy @ IPN Note: 1) Accuracy @ TA (% of IPN) = X + ( TCG × (TA –25) + TCIOE 10000 1000 × IPN Min Typ Max Comment 100 For UC = 3.3 V ±5 % 40 −100 3.135 T jumper = 120 °C 3.3 3.465 19 25 1.65 1.67 Internal reference 1.7 External reference 1.15 Over operating temperature range 200 300 series 2 5 series Vout − Vref −40 °C … 105 °C 460 mV @ IPN 11.5 Factory adjustment 450 4.5 4 9 14 × 100 × (TA –25)). Page 7/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Electrical data HLSR 50-P/SP33 At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9). Parameter Symbol Unit Primary nominal rms current IPN A Primary current, measuring range IPM A Number of primary turns NP - 1 Resistance of primary jumper @ TA = 25 °C RP mΩ 0.21 Resistance of primary jumper @ TA = 105 °C RP mΩ 0.29 Supply voltage UC V Current consumption IC mA Reference voltage (output) Vref V 1.63 Reference voltage (input) Vref V 0.5 Vout − Vref V −1.15 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Capacitive loading CL nF 0 6 Electrical offset voltage @ IP = 0 VOE mV −5 5 Electrical offset current referred to primary IOE mA −543 543 Temperature coefficient of Vref TCVref ppm/K −150 150 Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 Temperature coefficient of IOE TCIOE mA/K −8.15 8.15 Theoretical sensitivity Gth mV/A Sensitivity error εG % −0.5 0.5 Output voltage range @ IPM Temperature coefficient of G Min Typ Max 50 −125 3.135 125 3.3 3.465 19 25 1.65 1.67 Internal reference 1.7 External reference 1.15 Over operating temperature range 200 300 series 2 5 series ppm/K −200 200 εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.8 0.8 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.25 0.25 Reaction time @ 10 % of IPN tra µs tr µs BW kHz Output rms voltage noise spectral density 100 Hz … 100 kHz eno µV/√ Hz Output voltage noise DC … 10 kHz DC … 100 kHz DC … 1 MHz Vno mVpp Accuracy @ IPN Vout − Vref −40 °C … 105 °C 460 mV @ IPN 9.2 TCG Response time @ 90 % of IPN For UC = 3.3 V ±5 % T jumper = 120 °C Linearity error 0 … IPN Frequency bandwidth (−3 dB) Comment Factory adjustment 2 @ 50 A/µs 2.5 @ 50 A/µs 450 4 3.3 7.3 12 X % of IPN −1 1 Accuracy @ IPN @ TA = +85 °C X85 °C % of IPN −3.2 3.2 See formula note 1) Accuracy @ IPN @ TA = +105 °C X105 °C % of IPN −3.9 3.9 See formula note 1) Note: 1) Accuracy @ TA (% of IPN) = X + ( TCG × (TA –25) + 10000 TCIOE 1000 × IPN × 100 × (TA –25)). Page 8/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Maximum continuous DC current IP (A) 60 40 HLSR 10-P/SP33 HLSR 20-P/SP33 HLSR 32-P/SP33 HLSR 40-P/SP33 HLSR 50-P/SP33 20 0 -40 -20 0 20 40 60 80 100 120 140 TA (°C) Important notice: whatever the usage and/or application, the transducer jumper temperature shall not go above the maximum ratings of 120 °C as stated in page 2 of this datasheet. Definition of typical, minimum and maximum values Minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values shown in “typical” graphs. On the other hand, measured values are part of a statistical distribution that can be specified by an interval with upper and lower limits and a probability for measured values to lie within this interval. Unless otherwise stated (e.g. “100 % tested”), the LEM definition for such intervals designated with “min” and “max” is that the probability for values of samples to lie in this interval is 99.73 %. For a normal (Gaussian) distribution, this corresponds to an interval between −3 sigma and +3 sigma. If “typical” values are not obviously mean or average values, those values are defined to delimit intervals with a probability of 68.27 %, corresponding to an interval between −sigma and +sigma for a normal distribution. Typical, minimum and maximum values are determined during the initial characterization of the product. Page 9/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Measuring range versus external reference voltage HLSR 10-xx/SP33 HLSR 20-xx/SP33 75 150 125 Uc = 3.3 V Uc = 3.14 V Uc = 2.97 V 25 0 100 Uc = 3.3 V Uc = 3.14 V Uc = 2.97 V 75 IP (A) IP (A) 50 50 25 0 -25 -25 -50 -50 -100 -75 -125 -75 0.5 0.7 0.9 1.1 1.3 1.5 -150 1.7 0.5 Vref (V) 1.1 1.3 1.5 1.7 HLSR 40-xx/SP33 150 125 Uc = 3.3 VA Uc = 3.14 V Uc = 2.97 V 100 75 25 0 -25 Uc = 3.3 V Uc = 3.14 V Uc = 2.97 V 125 100 75 50 IP (A) 50 IP (A) 0.9 Vref (V) HLSR 32-xx/SP33 150 0.7 25 0 -25 -50 -50 -75 -75 -100 -100 -125 -125 -150 -150 0.5 0.7 0.9 1.1 Vref (V) 1.3 1.5 0.5 1.7 0.7 0.9 1.1 Vref (V) 1.3 1.5 1.7 HLSR 50-xx/SP33 150 Uc = 3.3 V Uc = 3.14 V Uc = 2.97 V 125 100 75 IP (A) 50 25 0 -25 -50 -75 -100 -125 -150 0.5 0.7 0.9 1.1 Vref (V) 1.3 1.5 1.7 Page 10/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series PCB footprint (in mm. General linear tolerance ±0.2 mm) dCI dCp Assembly on PCB ●● Recommended PCB hole diameter ●● Maximum PCB thickness ●● Wave soldering profile No clean process only. 1.6 mm for primary pins 1 mm for secondary pins 2.4 mm maximum 260 °C for 10 s Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage.This transducer is a build-in device, whose conducting parts must be inaccessible after installation.A protective housing or additional shield could be used.Main supply must be able to be disconnected. Page 11/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HLSR-P/SP33 series Dimensions (in mm. General linear tolerance ±0.2 mm) Connection Uc V V out ref IP Remarks ●● Vout is positive with respect to Vref when positive IP flows in direction of the arrow shown on the drawing above ●● Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: Products/Product Documentation. Page 12/12 7September2015/Version 7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com