SPECIFICATIONS


Ranges from 20 to 350 bar (300 to 5,000 psi)

Operating temperature up to 125 °C (257 °F)

±0.25%

Miniature Design and Light Weight
±1% Total Error Band
Available male threads such as :
M5x0.8
10-32 UNF
M8x1
5/16-24 UNF



0.5 to 4.5V amplified output
The EB100 uses TE’s UltraStable technology that provides
stability over a wide temperature range and performance
previously available only in much higher priced sensors. The
UltraStable technology employs a silicon-based strain gage,
isolated from the media by an oil-filled capsule and a stainless
steel diaphragm. The high stability offers excellent repeatability
and minimal hysteresis.
APPLICATIONS

Combined errors of linearity, hysteresis & repeatability
The EB100 pressure transducer is the smallest design proposed
by TE Connectivity from the UltraStable line. It sets a new price /
performance standard for demanding commercial and heavy
industrial applications where high accuracy, small size and low
weight are desirable. This series is suitable for measurement of
liquid or gas pressure, including difficult media such as
contaminated water, steam, and mildly corrosive fluids.
FEATURES



Unique pressure reference version Absolute
Motor Sport: Oil, Coolant, Fuel, Brake
Systems
Hydraulic/Pneumatic Systems
Automotive Test Stands
Military/Aerospace Test Stands
The 100% stainless steel media isolation covers all but the most
corrosive environments, offering excellent durability. Custom
OEM designs are available including various ports and output
options.
On request, Instruction documents can be provided to ease the
selection and use of our sensors and provide helpful tips.
SENSOR SOLUTIONS ///EB100_en
08/2016
Page 1
EB100
High Accuracy Miniature Pressure Transducer
STANDARD RANGES
Ranges (FS)
bar
psi
20
300
35
500
70
1K
100
1.5K
200
3K
350
5K
Pressure Reference
Pressure Overload
(rated pressure)
Burst Pressure
(rated pressure)
2 x FS
3 x FS
2 x FS
3 x FS

2 x FS
3 x FS
2 x FS
3 x FS

2 x FS
3 x FS
2 x FS
3 x FS
abs. (type3)




PERFORMANCE SPECIFICATIONS (typical values at temperature 23±3°C)
PARAMETERS
VALUES
NOTES
Combined Non-Linearity, Hysteresis, and Repeatability
±0.25 %FS
Long Term Stability (1 year)
±0.1 %FS
Total Error Band (TEB over CTR)
±1 %FS
Bandwidth (-3 dB)
120 Hz
Isolation resistance @50Vdc
50 MΩ
Compensated Temperature Range (CTR)
-20 to +125 °C (-4 to+257 F)
Operating Temperature Range (OTR)
-40 to +125 °C (-40 to +257 F)
Storage Temperature
-40 to +125 °C (-40 to +257 F)
Vibration (20 to 200Hz)
20 g
3
Shock (11ms)
50 g
4
Pressure Cycles (Zero to Full Scale)
1 Million
Weight (without cable)
15 grams +21 grams per meter of cable
Ingress Protection
IP66
Media Compatibility
Fluids compatible with 17-4PH, 316 S.S. and FKM Fluoroelastomer
1
2
Notes
1. Best fit straight line for all pressure ranges except for 200 bar (3 kpsi) = +/-0.35% and 350 bar (5 kpsi) = +/-0.5%.
2. TEB includes all accuracy errors, thermal errors, span and zero tolerances.
3. Per MIL-STD-810C, Procedure 514.2, Figure 514.2-2, Curve L.
4. 1/2 sine per MIL-STD 202F Method 213B condition A.
CE compliance
IEC 55022 Emissions Class A & B
IEC 61000-4-2 Electrostatic Discharge Immunity (2kV contact/2kV air)
IEC 61000-4-3 EM Field Immunity (3V/m)
IEC 61000-4-4 Electrical Fast Transient Immunity (0.5kV)
IEC 61000-4-6 Conducted Immunity (3V)
SUPPLY VOLTAGE
ELECTRICAL CONNECTION OPTIONS (table 1)
Code
Supply voltage
Signal
Code
Connection
U
8 to 30 V (current < 5 mA)
0.5 – 4.5 V
M
1 metre of shielded cable (PFA)
P
5 metres of shielded cable (PFA)
R
10 metres of shielded cable (PFA)
S
1 metre of shielded cable (PFA) fully covered by shrink tube
model Raychem DR25 or equivalent
SENSOR SOLUTIONS ///EB100_en
08/2016
Page 2
EB100
High Accuracy Miniature Pressure Transducer
DIMENSIONS
PHYSICAL (table 2)
Model
Pressure port
Length "C"
Hex."D"
O-ring supplied
Installation torque max
N
M5x0.8
6.6 (.26”)
11 (.433")
Ø3.5x1.5 FKM Fluoroelastomer
1 Nm (9 In-Pounds)
V
10-32 UNF-2A
6.6 (.26”)
11 (.433")
Ø3.5x1.5 FKM Fluoroelastomer
1 Nm (9 In-Pounds)
S
M8X1
7.6 (.30”)
11 (.433")
Ø6.07x1.63 FKM Fluoroelastomer
3 Nm (27 In-Pounds)
Q
5/16-24 UNF-2A
7.6 (.30”)
11 (.433")
Ø6.07x1.63 FKM Fluoroelastomer
3 Nm (27 In-Pounds)
P
M10x1
8.2 (.32")
13 (.512")
Ø7.65x1.63 FKM Fluoroelastomer
5 Nm (27 In-Pounds)
X
3/8-24 UNF-2A
8.2 (.32")
13 (.512")
Ø7.65x1.63 FKM Fluoroelastomer
5 Nm (27 In-Pounds)
INSTALLATION & CONNECTION
RECOMMENDED PRESSURE FITTING DESIGN (1)
Thread "A"
Dim. “B”
Dim. “C”
Dim. “D”
M5x0.8(2)
6.35 mm
1.5 mm
0.2 mm
0.25”
0.059”
0.008”
M8x1
9.1 mm
1.9 mm
0.3 mm
5/16-24 UNF-2A
0.358”
0.074”
0.012”
10.7 mm
1.9 mm
0.3 mm
10-32
UNF(2)
M10x1
3/8-24 UNF-2A
0.421"
0.074”
0.012”
1. Tolerances on dimensions = ± 0.05 mm (0.002”)
This pressure fitting design is only a recommendation but it stays under customer's responsibility.
2. For model M5x0.8 or 10-32 UNF used with pressure higher than 200 bar (3k psi) it is recommended to replace O-ring by
bonded ring (ref: MSE05417) and to design the pressure fitting without O-ring chamber.
WIRING: SHIELDED CABLE 4 LEADS AWG26
RED
+SUPPLY
GREEN
+OUTPUT
WHITE
-OUTPUT
BLACK
-SUPPLY
The shield is not connected to sensor’s body.
SENSOR SOLUTIONS ///EB100_en
08/2016
Page 3
EB100
High Accuracy Miniature Pressure Transducer
ORDERING INFORMATION
EB1
U
M
-
0000
1
5
-
100B
G
Model
Supply
Voltage
Connection Type
-
0000
Calibration
Certificate
Pressure
Port
-
Pressure
Range
Pressure
Type
M = 1 Meter Cable
P = 5 Meter Cable
R = 10 Meter Cable
S = 1 Meter Cable
fully covered by
shrink tube
Raychem DR25 or
equivalent
-
0 = No calibration
certificate
1 = With calibration
certificate
S = M8x1
Q = 5/16-24 UNF
N = M5x0.8
V = 10-32 UNF Male
P = M10x1 Male
X = 3/8-24 UNF Male
EB1
U = 8 to 30V
-
300P
500P
01KP
1K5P
03KP
05KP
020B
035B
070B
100B
200B
350B
A = Absolute
The psi range models are only supplied with imperial thread design.
The bar range models are only supplied with metric thread design.
NORTH AMERICA
EUROPE
ASIA
Measurement Specialties, Inc.,
a TE Connectivity company
45738 Northport Loop West
Fremont, CA 94538
Tel: +1 800 767 1888
Fax: +1 510 498 1578
[email protected]
MEAS France SAS,
a TE Connectivity company
4 Rue Gaye Marie
31027 Toulouse, France
Tel: +33 (5) 822 822 00
Fax: +33 (5) 820 821 51
[email protected]
Measurement Specialties (China) Ltd.,
a TE Connectivity company
No. 26 Langshan Road
Shenzhen High-Tech Park (North) Nanshan District,
Shenzhen, 518057
China
Tel: +86 755 3330 5088
Fax: +86 755 3330 5099
[email protected]
TE.com/sensorsolutions
Measurement Specialties, Inc., a TE Connectivity company.
Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein
might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes
no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard
Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse
of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
© 2015
TE Connectivity Ltd. family of companies
SENSOR SOLUTIONS ///EB100_en
All Rights Reserved.
08/2016
Page 4
Similar pages