LK-P VDE 1a 10A TV-5 rated power relays LK-P RELAYS FEATURES 1. High switching capacity: 10 A 277V AC 2. High insulation resistance between contact and coil 1) Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC60065) 2) Surge withstand voltage between contact and coil: 10,000 V 3. Popular terminal pitch in AV equipment field 4. Space-saving slim type Base area: Width 11 × Length 24 mm Width .433 × Length .945 inch RoHS compliant 5. Conforms to the various safety standards UL, CSA, VDE, TÜV and SEMKO approved TYPICAL APPLICATIONS • Audio visual equipment TVs, VTRs • Office equipment LBP, CRT • Home appliances Refrigerator, Air conditioner ORDERING INFORMATION LKP 1a F LK-P relay Contact arrangement 1a: 1 Form A Protective construction F: Flux-resistant type Nominal coil voltage (DC) 5V, 9V, 12V, 24V Notes: Certified by UL, CSA, TÜV and SEMKO VDE approved type is available. Please consult us for details. TYPES Contact arrangement 1 Form A Nominal coil voltage 5V DC 9V DC 12V DC 24V DC Part No. LKP1aF-5V LKP1aF-9V LKP1aF-12V LKP1aF-24V Notes: 1. Standard packing Carton: 100 pcs. Case: 500 pcs. 2. 18 V DC types are also available. Please consult us for details. RATING 1. Coil data Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) 5V DC 9V DC 12V DC 24V DC 70%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) Panasonic Corporation Nominal operating current [±10%] (at 20°C 68°F) 106.4mA 58.8mA 44.2mA 22.1mA Automation Controls Business Unit Coil resistance [±10%] (at 20°C 68°F) 47Ω 153Ω 272Ω 1,087Ω Nominal operating power Max. applied voltage (at 20°C 68°F) 530mW 6.5V DC 11.7V DC 15.6V DC 31.2V DC industrial.panasonic.com/ac/e/ ASCTB199E 201202-T LK-P 2. Specifications Characteristics Contact Rating Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Min. switching capacity (reference value)*1 Insulation resistance (Initial) Breakdown voltage (Initial) Specifications 1 Form A Max. 100 mΩ (By voltage drop 6 V DC 1A) AgSnO2 type 10A 277V AC, 5A 30V DC 2,770VA, 150W 277V AC, 30V DC 10A (AC), 5A (DC) 100mA, 5V DC Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. Between open contacts Between contact and coil 1,000 Vrms for 1 min. (Detection current: 10 mA) 4,000 Vrms for 1 min. (Detection current: 10 mA) Max. 45°C 113°F (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 10A, at 70°C 158°F) Temperature rise (coil) Electrical characteristics Surge breakdown voltage*2 (Between contact and coil) (Initial) Operate time (at nominal voltage) (at 20°C 68°F) (Initial) Release time (at nominal voltage) (at 20°C 68°F) (Initial) Expected life Conditions Max. 15 ms (excluding contact bounce time.) Max. 5 ms (excluding contact bounce time) (Without diode) 200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 1.5 mm Min. 2×106 Min. 105 (ON/OFF = 1.5s : 1.5s at rated load) Ambient temperature: –40°C to +70°C –40°F to +158°F, Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature), Air pressure: 86 to 106kPa 20 times/min. (at nominal switching capacity) Approx. 12 g .42 oz Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times/min.) Electrical Shock resistance Mechanical characteristics 10,000 V Conditions for operation, transport and storage*3 Max. operating speed Unit weight * Specifications will vary with foreign standards certification ratings. Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. REFERENCE DATA 1. Max. switching power 2. Coil temperature rise 3. Ambient temperature characteristics and coil applied voltage Sample: LKP1aF-12V, 6 pcs. Point measured: coil inside Contact current: 5 A, 10 A Contact current: 10 A 60 220 Temperature rise, °C Contact current, A 55 10 1 50 20°C 10A 20°C 5A 45 70°C 10A 70°C 5A 40 35 30 Coil applied voltage, %V 100 Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F) 180 140 100 Cold start 60 Pick-up voltage 25 0 10 100 Contact voltage, V ASCTB199E 201202-T 20 Panasonic Corporation 0 100 120 Coil applied voltage, %V Automation Controls Business Unit 20 0 10 20 30 40 50 60 70 Ambient temperature, °C industrial.panasonic.com/ac/e/ 80 LK-P 4. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: room temperature 100 Life, ×104 250V AC resistive load 10 1 0 2 4 6 8 10 Contact current, A 5. Electrical life test (10 A 277 V AC, resistive load) Change of pick-up and drop-out voltage 12 Circuit: 12V DC Contact welding detection and Miscontacting detection circuit 45 10 Pick-up voltage 8 Max. 6 x Min. 4 Drop-out voltage Max. x Min. 2 0 0 DIMENSIONS (mm inch) 50 5 No. of operations, ×104 The CAD data of the products with a CAD Data 10 40 35 30 25 20 Max. 15 x 10 Min. 5 0 0 5 No. of operations, ×104 PC board pattern (Bottom view) 2-0.9 dia. 2-.035 dia. 16.5 .650 0.5 .020 1.65 .065 Max. 24.0 .945 16.5 .650 20.0 .787 Tolerance: ±0.1 ±.004 4 .157 0.3 .012 2-1.3 dia. 2-.051 dia. 7.5 .295 Max. 25.0 .984 0.5 dia. .020 dia. 10 mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions CAD Data Contact resistance, mΩ Pick-up and drop-out voltage, V Sample: LKP1aF-12V, 6 pcs. Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: 20°C 68°F 277V AC Change of contact resistance Schematic (Bottom view) 0.4 .016 Max. 11.0 .433 1.0 .039 7.5 .295 20.0 .787 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: General tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 SAFETY STANDARDS UL/C-UL (Recognized) File No. Contact rating E43149 10A 277V AC 5A 30V DC CSA (Certified) File No. Contact rating LR26550 10A 277V AC etc. 5A 30V DC File No. 40014390 VDE (Certified) TV rating (UL/CSA) Contact rating File No. Rating 10A 250V AC (cosφ =1.0) UL TV-5 E43149 CSA LR26550 TÜV (Certified) SEMKO (Certified) File No. Rating File No. Contact rating B 11 05 10A 250V AC (cosφ =1.0) 807779 3/100A 250V AC 13461 299 5A 30V DC (0ms) 5/40A 250V AC 10A 250V DC For Cautions for Use. Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB199E 201202-T