Panasonic LKP1AF-9V 1a 10a tv-5 rated power relay Datasheet

LK-P
VDE
1a 10A TV-5 rated
power relays
LK-P RELAYS
FEATURES
1. High switching capacity: 10 A 277V
AC
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC60065)
2) Surge withstand voltage between
contact and coil: 10,000 V
3. Popular terminal pitch in AV
equipment field
4. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
RoHS compliant
5. Conforms to the various safety
standards
UL, CSA, VDE, TÜV and SEMKO
approved
TYPICAL APPLICATIONS
• Audio visual equipment
TVs, VTRs
• Office equipment
LBP, CRT
• Home appliances
Refrigerator, Air conditioner
ORDERING INFORMATION
LKP 1a
F
LK-P relay
Contact arrangement
1a: 1 Form A
Protective construction
F: Flux-resistant type
Nominal coil voltage (DC)
5V, 9V, 12V, 24V
Notes: Certified by UL, CSA, TÜV and SEMKO
VDE approved type is available. Please consult us for details.
TYPES
Contact arrangement
1 Form A
Nominal coil voltage
5V DC
9V DC
12V DC
24V DC
Part No.
LKP1aF-5V
LKP1aF-9V
LKP1aF-12V
LKP1aF-24V
Notes: 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
2. 18 V DC types are also available. Please consult us for details.
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
5V DC
9V DC
12V DC
24V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
Panasonic Corporation
Nominal operating
current
[±10%] (at 20°C 68°F)
106.4mA
58.8mA
44.2mA
22.1mA
Automation Controls Business Unit
Coil resistance
[±10%] (at 20°C 68°F)
47Ω
153Ω
272Ω
1,087Ω
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
530mW
6.5V DC
11.7V DC
15.6V DC
31.2V DC
industrial.panasonic.com/ac/e/
ASCTB199E 201202-T
LK-P
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (reference value)*1
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Specifications
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
10A 277V AC, 5A 30V DC
2,770VA, 150W
277V AC, 30V DC
10A (AC), 5A (DC)
100mA, 5V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts
Between contact and coil
1,000 Vrms for 1 min. (Detection current: 10 mA)
4,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 45°C 113°F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 10A, at 70°C 158°F)
Temperature rise (coil)
Electrical
characteristics
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Expected life
Conditions
Max. 15 ms (excluding contact bounce time.)
Max. 5 ms (excluding contact bounce time) (Without diode)
200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 2×106
Min. 105 (ON/OFF = 1.5s : 1.5s at rated load)
Ambient temperature: –40°C to +70°C –40°F to +158°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Air pressure: 86 to 106kPa
20 times/min. (at nominal switching capacity)
Approx. 12 g .42 oz
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Electrical
Shock resistance
Mechanical
characteristics
10,000 V
Conditions for operation, transport and storage*3
Max. operating speed
Unit weight
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
1. Max. switching power
2. Coil temperature rise
3. Ambient temperature characteristics and coil
applied voltage
Sample: LKP1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 5 A, 10 A
Contact current: 10 A
60
220
Temperature rise, °C
Contact current, A
55
10
1
50
20°C 10A
20°C 5A
45
70°C 10A
70°C 5A
40
35
30
Coil applied voltage, %V
100
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature set as
115°C 239°F)
180
140
100
Cold start
60
Pick-up voltage
25
0
10
100
Contact voltage, V
ASCTB199E 201202-T
20
Panasonic Corporation
0
100
120
Coil applied voltage, %V
Automation Controls Business Unit
20
0
10
20
30
40
50
60
70
Ambient temperature, °C
industrial.panasonic.com/ac/e/
80
LK-P
4. Life curve
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: room temperature
100
Life, ×104
250V AC resistive load
10
1
0
2
4
6
8
10
Contact current, A
5. Electrical life test
(10 A 277 V AC, resistive load)
Change of pick-up and drop-out voltage
12
Circuit:
12V DC
Contact
welding
detection
and Miscontacting
detection
circuit
45
10
Pick-up voltage
8
Max.
6
x
Min.
4
Drop-out voltage
Max.
x
Min.
2
0
0
DIMENSIONS (mm inch)
50
5
No. of operations, ×104
The CAD data of the products with a
CAD Data
10
40
35
30
25
20
Max.
15
x
10
Min.
5
0
0
5
No. of operations, ×104
PC board pattern (Bottom view)
2-0.9 dia.
2-.035 dia.
16.5
.650
0.5
.020
1.65
.065
Max. 24.0
.945
16.5
.650
20.0
.787
Tolerance: ±0.1 ±.004
4
.157
0.3
.012
2-1.3 dia.
2-.051 dia.
7.5
.295
Max. 25.0
.984
0.5 dia.
.020 dia.
10
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
Contact resistance, mΩ
Pick-up and drop-out voltage, V
Sample: LKP1aF-12V, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C 68°F
277V AC
Change of contact resistance
Schematic (Bottom view)
0.4
.016
Max. 11.0
.433
1.0
.039
7.5
.295
20.0
.787
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
SAFETY STANDARDS
UL/C-UL (Recognized)
File No.
Contact rating
E43149
10A 277V AC
5A 30V DC
CSA (Certified)
File No.
Contact rating
LR26550
10A 277V AC
etc.
5A 30V DC
File No.
40014390
VDE (Certified)
TV rating (UL/CSA)
Contact rating
File No.
Rating
10A 250V AC (cosφ =1.0) UL
TV-5
E43149
CSA
LR26550
TÜV (Certified)
SEMKO (Certified)
File No.
Rating
File No.
Contact rating
B 11 05
10A 250V AC (cosφ =1.0) 807779
3/100A 250V AC
13461 299 5A 30V DC (0ms)
5/40A 250V AC
10A 250V DC
For Cautions for Use.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB199E 201202-T