VIMARLOW NL2012T Thermoelectric module Datasheet

Technical Data Sheet for NL2012T
Thermoelectric Module
NOMINAL PERFORMANCE IN NITROGEN
Hot Side Temperature (°C)
Δ Tmax (°C):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
PRODUCT FEATURES
•
•
•
•
27
77
2.4
1.2
5.4
4.18
50
88
2.5
1.2
6.1
--
ORDERING OPTIONS
RoHS EU Compliant
Pretinned metallized ceramic surface(s) with 117°C solder.
Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
Elevated temperature burn-in with test data provided.
Model Number
NL2012T-01
NL2012T-02
NL2012T-03
Description
Both Surfaces are Metallized
Hot Side Exterior is Metallized
No Metallization
OPERATION CAUTIONS
INSTALLATION
For maximum reliability, storage and operation below
85°C in a non-condensing environment is recommended.
To minimize thermal stress, use linear/proportional
temperature control or a similar method rather than an
ON/OFF method.
Recommended mounting methods: Bonding with thermal
epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEM Installation Guide.
II-VI Marlow – Dallas, TX USA
214-340-4900
877-627-5691
[email protected]
Marlow Industries Europe
GmbH - Germany
+49 (0) 6150 5439 - 403
[email protected]
II-VI Japan Inc.
81 43 297 2693 (tel)
[email protected]
www.ii-vi.co.jp
MI Form 005-0808 Rev. B
II-VI Singapore Pte., Ltd.
(65) 6481 8215 (tel)
[email protected]
Marlow Industries China, II-VI
Technologies Beijing
86-10-643 98226
[email protected]
DOC # 102-0300 REV K - PAGE 1 OF 2
www.marlow.com
Hot Side Temperature 27°C
40.0
20.0
0.0
6.0
4.0
2.0
0.0
0.0
Q=0
T=0
0.2
0.4 0.6 0.8 1.0
CURRENT (AMPS)
80.0
T (C)
60.0
100.0
60.0
40.0
20.0
0.0
VOLTAGE (VDC)
80.0
T (C)
Hot Side Temperature 50°C
HEAT
LOAD
(WATTS)
0.00
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
100.0
VOLTAGE (VDC)
TYPICAL PERFORMANCE CURVES
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
1.2
HEAT
LOAD
(WATTS)
0.00
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
6.0
4.0
2.0
0.0
0.0
Q=0
T=0
0.2
0.4 0.6 0.8 1.0
CURRENT (AMPS)
1.2
MECHANICAL CHARACTERISTICS
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691.
Beryllium Oxide Handling
Precautions
Beryllium oxide can be toxic only when
dust, mist, or fumes containing particles
small enough to enter the lungs are
inhaled. For the user, precautions required
are to avoid grinding, machining or
pulverizing the material by mechanical,
thermal, or chemical processing.
marlow industries, inc.
R
All units are in inches and [ ] are in millimeters unless otherwise stated.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
Marlow reserves the right to make product changes without notice.
MI Form 005-0808 Rev. B
DOC # 102-0300 REV K - PAGE 2 OF 2
www.marlow.com