Technical Data Sheet for NL2012T Thermoelectric Module NOMINAL PERFORMANCE IN NITROGEN Hot Side Temperature (°C) Δ Tmax (°C): Qmax (watts): Imax (amps): Vmax (vdc): AC Resistance (ohms): PRODUCT FEATURES • • • • 27 77 2.4 1.2 5.4 4.18 50 88 2.5 1.2 6.1 -- ORDERING OPTIONS RoHS EU Compliant Pretinned metallized ceramic surface(s) with 117°C solder. Thermistor mounted on edge of cold side ceramic. (Calibration available.) Elevated temperature burn-in with test data provided. Model Number NL2012T-01 NL2012T-02 NL2012T-03 Description Both Surfaces are Metallized Hot Side Exterior is Metallized No Metallization OPERATION CAUTIONS INSTALLATION For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method. Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEM Installation Guide. II-VI Marlow – Dallas, TX USA 214-340-4900 877-627-5691 [email protected] Marlow Industries Europe GmbH - Germany +49 (0) 6150 5439 - 403 [email protected] II-VI Japan Inc. 81 43 297 2693 (tel) [email protected] www.ii-vi.co.jp MI Form 005-0808 Rev. B II-VI Singapore Pte., Ltd. (65) 6481 8215 (tel) [email protected] Marlow Industries China, II-VI Technologies Beijing 86-10-643 98226 [email protected] DOC # 102-0300 REV K - PAGE 1 OF 2 www.marlow.com Hot Side Temperature 27°C 40.0 20.0 0.0 6.0 4.0 2.0 0.0 0.0 Q=0 T=0 0.2 0.4 0.6 0.8 1.0 CURRENT (AMPS) 80.0 T (C) 60.0 100.0 60.0 40.0 20.0 0.0 VOLTAGE (VDC) 80.0 T (C) Hot Side Temperature 50°C HEAT LOAD (WATTS) 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 100.0 VOLTAGE (VDC) TYPICAL PERFORMANCE CURVES ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN 1.2 HEAT LOAD (WATTS) 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 6.0 4.0 2.0 0.0 0.0 Q=0 T=0 0.2 0.4 0.6 0.8 1.0 CURRENT (AMPS) 1.2 MECHANICAL CHARACTERISTICS For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691. Beryllium Oxide Handling Precautions Beryllium oxide can be toxic only when dust, mist, or fumes containing particles small enough to enter the lungs are inhaled. For the user, precautions required are to avoid grinding, machining or pulverizing the material by mechanical, thermal, or chemical processing. marlow industries, inc. R All units are in inches and [ ] are in millimeters unless otherwise stated. For customer support or general questions please contact a local office or visit our website at www.marlow.com. Marlow reserves the right to make product changes without notice. MI Form 005-0808 Rev. B DOC # 102-0300 REV K - PAGE 2 OF 2 www.marlow.com