Mean Well ENC-120-12 120w programmable desktop type battery charger Datasheet

120W Programmable Desktop Type Battery Charger
UL60950-1
ENC-120
series
IEC60950-1
■ Features
Charger for lead-acid batteries (flooded, Gel and AGM)
and li-ion batteries (lithium iron and lithium manganese)
Built-in 3 stage programmable charging curve
Universal AC input / Full range
Built-in active PFC function
Fanless design, cooling by free air convection
Built-in temperature compensation function
Protection: Short circuit / Over voltage /Over temperature /
■ Applications
Radio system backup solution
Electric scooter charger
Surveillance system
Battery under voltage / Battery over voltage / Battery reverse
polarity protection
3 years warranty
■ Description
ENC-120 is a single output 120W AC/DC desktop type charger with 3 stage charging curve. In addition to
the embedded pre-defined charging curves, the default curve is programmable and thus able to accommodate
different types of batteries, such as lead-acid batteries (gel, flooded and AGM) and li-ion batteries
(lithium iron and lithium manganese). With the rugged mechanical design along with the high efficiency
circuitry, ENC-120 operates for the ambient temperature range -30~+70℃ under free air convection.
■ Model Encoding
ENC - 120 - 24
Nominal voltage
Rated wattage
Series name
File Name:ENC-120-SPEC 2017-02-17
120W Programmable Desktop Type Battery Charger
ENC-120
series
SPECIFICATION
MODEL
OUTPUT
ENC-120-24
ENC-120-48
BOOST CHARGE VOLTAGE(Vboost)(default) 14.4V
ENC-120-12
28.8V
57.6V
FLOAT CHARGE VOLTAGE(Vfloat)(default) 13.8V
27.6V
55.2V
CHARGE VOLTAGE RANGE Note.3 9 ~ 15V
18 ~ 30V
36 ~ 60V
OUTPUT CURRENT(CC) (default) 8A
4A
2A
RATED POWER
115.2W
115.2W
15 ~ 40AH
10 ~ 20AH
115.2W
RECOMMENDED BATTERY
CAPACITY (AMP HOURS) Note.4 30 ~ 80AH
LEAKAGE CURRENT FROM
<1mA
BATTERY (Typ.)
VOLTAGE RANGE
Note.5 90 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
INPUT
PROTECTION
127 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)
89%
1.25A/115VAC
90%
COLD START 65A at 230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
SHORT CIRCUIT
Note.6 Protection type : Shut down O/P voltage, re-power on to recover
OVER VOLTAGE
Note.7
15.5 ~ 18.2V
REVERSE POLARITY
90.5%
0.63A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
31 ~ 36.5V
62.1 ~ 72.9V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
By internal fuse
Shut down O/P voltage, recovers automatically after temperature goes down
OVER TEMPERATURE
FUNCTION TEMPERATURE COMPENSATION By NTC
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING TEMP.
20 ~ 95% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.05%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
IEC60950-1, UL60950-1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Standard
Test Level / Note
EN55032 (CISPR32) / FCC PART15 (CISPR22) Class B
Conducted
Radiated
EN55032 (CISPR32) / FCC PART15 (CISPR22) Class B
Harmonic Current
EN61000-3-2
-----
SAFETY &
Voltage Flicker
EN61000-3-3
-----
EMC
EN55024
(Note 8)
Parameter
Standard
Test Level / Note
ESD
EN61000-4-2
Level 3, 8KV air ; Level 2, 4KV contact
Radiated
EN61000-4-3
Level 2, 3V/m
EFT / Burst
EN61000-4-4
Level 2, 1KV
Surge
EN61000-4-5
Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted
EN61000-4-6
Level 2, 3Vrms
Magnetic Field
EN61000-4-8
Level 1, 1A/m
Voltage Dips and Interruptions
EN61000-4-11
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
EMC EMISSION
EMC IMMUNITY
OTHERS
206K hrs min.
DIMENSION
192*178*45.5mm (L*W*H)
0.98Kg; 10pcs/10.8Kg /1.34CUFT
PACKING
NOTE
MIL-HDBK-217F (25℃)
MTBF
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is the range when programming Vboost or Vfloat by using SBP-001, the smart battery charging programmer.
4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
7. Each model incorporates a MCU-controlled dynamic over voltage protection, which is about 115% of Vboost over Constant Current stage and Constant
Voltage stage whereas 115% of Vfloat over Float stage.
8. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:ENC-120-SPEC 2017-02-17
ENC-120
120W Programmable Desktop Type Battery Charger
series
Block Diagram
EMI FILTER
&
RECTIFIERS
I/P
POWER
SWITCHING
PFC
CIRCUIT
POLARITY
REVERSE
PROTECTION
RECTIFIERS
&
FILTER
+V
-V
O.C.P.
O.L.P.
FG
DETECTION
CIRCUIT
PWM & PFC
CONTROL
ACTIVE START
CIRCUIT
MCU
Charger mode select
Programable
O.V.P.
O.T.P.
U.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
60
50
40
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
70 (HORIZONTAL)
90
100
115
120
140
160 180
190
200
220
240
264
INPUT VOLTAGE (V) 60Hz
File Name:ENC-120-SPEC 2017-02-17
120W Programmable Desktop Type Battery Charger
ENC-120
series
Function Manual
1.Charging Curve
※ This series provides a 3 stage charging. The default curve is programmable, whereas other pre-defined curves can be
activated by the means of the DIP switch; please refer to the table below and the Mechanical Specification.
※ To accommodate the parameters of the charging curve, SBP-001, the smart battery charging programmer designed by
MEAN WELL, and a personal computer are needed. Please contact MEAN WELL for details.
◎ Default 3 stage charging curve
Start
V boost
V float
Charge Voltage
100% CC
Charge Current
10% CC
Constant Current
Constant Voltage
stage 1
stage 2
Color of LED
Status Indicator
Float
stage 3
Orange
Green
◎ Suitable for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese).
◎ Embedded 3 stage charging curve
MODEL
12V
24V
V boost
V float
Default, programmable
14.4
13.8
Pre-defined, gel batter
14
13.6
14.2
13.4
Pre-defined, AGM battery
14.5
13.5
Default, programmable
28.8
27.6
Pre-defined, gel battery
28
27.2
28.4
26.8
Description
CC(default)
Pre-defined, flooded battery
Pre-defined, flooded battery
8A
4A
Pre-defined, AGM battery
Default, programmable
48V
Pre-defined, gel battery
Pre-defined, flooded battery
2A
Pre-defined, AGM battery
29
27
57.6
55.2
56
54.4
56.8
53.6
58
54
2. Front Panel LED Indicators & Corresponding Signal at Function Pins
LED
Description
Green
Float (stage 3)
Orange
Charging (stage 1 or stage 2)
File Name:ENC-120-SPEC 2017-02-17
120W Programmable Desktop Type Battery Charger
Mechanical Specification
ENC-120
Case No. 252
192
series
Unit:mm
45.5
4.3
LED
TB1
1
2
3
4
DIP
SW
CN31
1
5
2
6
12
178
CN31
SWITCH
INLET
Terminal Pin No. Assignment (TB1):
Pin No.
1,2
3,4
Assignment
+V
-V
DIP SW:
1
OFF
ON
OFF
ON
2
OFF
OFF
ON
ON
Description
Default, programmable
Pre-defined, Gel battery
Pre-defined, flooded battery
Pre-defined, AGM battery
Connector Pin No. Assignment (CN31) :
HRS DF11-6DP-2DS or equivalent
Pin No.
1
2
3
4
5
6
Assignment
Prog- +3.3V
Prog- GND
Prog- RX
Prog- TX
RTH+
RTH-
Mating Housing
Terminal
HRS DF11-6DS HRS DF11-**SC
or equivalent
or equivalent
File Name:ENC-120-SPEC 2017-02-17
Similar pages