Series CCRS-33S/CRS-33S COAX SWITCHES Miniature DC–18 GHz Failsafe 2P3T Coaxial Switch PART NUMBER DESCRIPTION CCRS-33S Commercial Failsafe 2P3T, DC-18GHz CRS-33S Elite Failsafe 2P3T, DC-18GHz The CCRS-33S/CRS-33S is a broadband, 2P3T, electromechanical coaxial switch designed to switch a microwave signal from a common input to either of two outputs. The characteristic impedance is 50 Ohms. The switches are small with the minimum spacing that is compatible with SMA connectors, and can also be used as a SPDT switch with external terminations. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS Operating Temperature Commercial Model, CCRS-33S Elite Model, CRS-33S Form Factor –40°C to 65°C –55°C to 85°C 2P3T, break before make Vibration (MIL-STD-202 Method 214, Condition D, non-operating) 10 g’s RMS Frequency Range CCRS-33S CRS-33S DC–18 GHz DC–18 GHz Shock (MIL-STD-202 Method 213, Condition D, non-operating) 500 g’s Characteristic Impedance 50 Ohms Standard Actuator Life Actuator Life w/ Additional Features 5,000,000 cycles 1,000,000 cycles Connector Type SMA Humidity (Moisture Seal) Available Weight 2.65 oz. (75.1g) (max.) Operate Time 10 ms (max.) Release Time 10 ms (max.) Actuation Voltage Available 12 Actuation Current, max. @ ambient 420 350 280 200 mA 15 24 28 V PERFORMANCE CHARACTERISTICS Frequency DC–6 GHz 6–12 GHz 12–18 GHz 0.1 0.2 0.3 Insertion Loss, dB, max. Isolation, dB, min. VSWR , max. 85 80 75 1.1:1 1.2:1 1.3:1 PART NUMBERING SYSTEM CCRS-33 S 1 C - T ** Options Series Connectors Actuator Type Actuator Voltage Connector S: SMA Female Actuator Voltage 1: 28 Vdc Failsafe 2: 15 Vdc Failsafe 3: 12 Vdc Failsafe 4: 24 Vdc Failsafe Actuator Type O: Standard Contacts C: Indicator Contacts **SEE PARTS LIST ON PAGE 8 Options T: TTL Drivers with Diodes D: Transient Suppression Diodes M: Moisture Seal S: 9 Pin D-Sub Connector For other options, contact factory. © 2012 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCRS-33S/CRS-33S Page 1 CCRS-33S\CRS-33S\062012\Q2 Series CCRS-33S/CRS-33S COAX SWITCHES Miniature DC–18 GHz Failsafe 2P3T Coaxial Switch SCHEMATICS AND MECHANICAL OUTLINE 2X SOLDER TERMINALS SOLDER WIRE MAXIMUM TEMP 250ºC FOR NO MORE THAN 5 SEC H = 1.75 STD & Indicator Model H = 1.90 All OTHER Models Indicators Analog TTL 1 6 “-S OPTION” 9-PIN D-SUB CONNECTOR (EXAMPLE: 9 PIN D-SUB PINOUT FOR FAILSAFE 2P3T TRUTH TABLE (with TTL option) OPTIONS Pin No. 1 2 3 4 5 6 7 8 9 Basic Indicators + - + - CCRS-33S/CRS-33S Page 2 A B C TTL CCRS-33S10-S) Indicators & TTL Common 1 Common 1 Vsw Vsw A B C Logic Input RF Path Indicator (if applicable) 1 0 2&3 4&5 B&C 1 1&2 3&4 A&C SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2012 TELEDYNE COAX SWITCHES CCRS-33S\CRS-33S\062012\Q2 Series CCRS-33S/CRS-33S COAX SWITCHES Miniature DC–18 GHz Failsafe 2P3T Coaxial Switch TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES Insertion Loss ( 6-12 GHz ) 0.0 0.0 -0.1 -0.1 -0.2 -0.2 Insertion Loss (dB) Insertion Loss (dB) Insertion Loss ( DC-6 GHz ) -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 -1.0 0 1 2 3 4 5 6 6 Frequency (GHz) 7 8 9 10 11 12 Frequency (GHz) Insertion Loss ( 12-18 GHz ) 0.0 Insertion Loss (dB) -0.1 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 12 13 14 15 16 17 18 Frequency (GHz) RF NOTES © 2012 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCRS-33S/CRS-33S Page 3 CCRS-33S\CRS-33S\062012\Q2 Series CCRS-33S/CRS-33S COAX SWITCHES Miniature DC–18 GHz Failsafe 2P3T Coaxial Switch TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES Isolation ( 6-12 GHz ) 0 -20 -20 -40 -40 Isolation (dB) Isolation (dB) Isolation ( DC-6 GHz ) 0 -60 -80 -60 -80 -100 -100 -120 -120 -140 -140 0 1 2 3 4 5 6 6 7 Frequency (GHz) 8 9 10 11 12 Frequency (GHz) Isolation ( 12-18 GHz ) 0 -20 Isolation (dB) -40 -60 -80 -100 -120 -140 12 13 14 15 16 17 18 Frequency (GHz) RF NOTES CCRS-33S/CRS-33S Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2012 TELEDYNE COAX SWITCHES CCRS-33S\CRS-33S\062012\Q2 Series CCRS-33S/CRS-33S COAX SWITCHES Miniature DC–18 GHz Failsafe 2P3T Coaxial Switch TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES VSWR ( 6-12 GHz ) 2.0 1.9 1.9 1.8 1.8 1.7 1.7 1.6 1.6 VSWR VSWR VSWR ( DC-6 GHz ) 2.0 1.5 1.4 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.1 1.0 1.0 0 1 2 3 4 5 6 6 Frequency (GHz) 7 8 9 10 11 12 Frequency (GHz) VSWR ( 12-18 GHz ) 2.0 1.9 1.8 VSWR 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 12 13 14 15 16 17 18 Frequency (GHz) RF NOTES © 2012 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCRS-33S/CRS-33S Page 5 CCRS-33S\CRS-33S\062012\Q2 Series CCRS-33S/CRS-33S COAX SWITCHES Miniature DC–18 GHz Failsafe 2P3T Coaxial Switch TYPICAL POWER PERFORMANCE CURVE Power Handling vs. Frequency 3000 2000 Power (W) 1000 800 600 400 STAN DAR DS 300 MA 200 SW ITC HES 100 80 60 40 30 20 10 .1 .2 .3 .4 .6 .8 1 2 4 6 8 10 18 Frequency GHz Estimates based on the following reference conditions: • Ambient temperature of 40°C or less • Sea level operation • Load VSWR of 1.20:1 maximum • No high-power (hot) switching Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions. CCRS-33S/CRS-33S Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2012 TELEDYNE COAX SWITCHES CCRS-33S\CRS-33S\062012\Q2 Series CCRS-33S/CRS-33S COAX SWITCHES Miniature DC–18 GHz Failsafe 2P3T Coaxial Switch GLOSSARY Actuator An actuator is the electromechanical mechanism that transfers the RF contacts from one position to another upon DC command. Arc Suppression Diode A diode is connected in parallel with the coil. This diode limits the “reverse EMF spike” generated when the coil deenergizes to 0.7 volts. The diode cathode is connected to the positive side of the coil and the anode is connected to the negative side. Date Code All switches are marked with either a unique serial number or a date code. Date codes are in accordance with MILSTD-1285 Paragraph 5.2.5 and consist of four digits. The first two digits define the year and the last two digits define the week of the year (YYWW). Thus, 1032 identifies switches that passed through final inspection during the 32nd week of 2010. Failsafe A failsafe switch reverts to the default or failsafe position when actuating voltage is removed. This is realized by a return spring within the drive mechanism. This type of switch requires the continuous application of operating voltage to select and hold any position. (Multi-position switches are normally open with no voltage applied). Indicator Indicators tell the system which position the switch is in. Other names for indicators are telemetry contacts or tellback circuit. Indicators are usually a set of internally mounted DC contacts linked to the actuator. They can be wired to digital input lines, status lights, or interlocks. Unless otherwise specified, the maximum indicator contact rating is 30 Vdc, 50 mA, or 1.5 Watts into a resistive load. Performance Parameters vs Frequency Generally speaking, the RF performance of coaxial switches is frequency dependent. With increasing frequency, VSWR and insertion loss increase while isolation decreases. All data sheets specify these three parameters as “worst case” at the highest operating frequency. If the switch is to be used over a narrow frequency band, better performance can be achieved. Actuator Current vs Temperature The resistance of the actuator coil varies as a function of temperature. There is an inverse relationship between the operating temperature of the switch and the actuator drive current. For switches operating at 28 VDC, the approximate actuator drive current at temperature, T, can be calculated using the equation: IT = IA [1 + .00385 (T-20)] Where: IT = Actuator current at temperature, T IA = Room temperature actuator current – see data sheet T = Temperature of interest in °C Magnetic Sensitivity An electro-mechanical switch can be sensitive to ferrous materials and external magnetic fields. Neighboring ferrous materials should be permitted no closer than 0.5 inches and adjacent external magnetic fields should be limited to a flux density of less than 5 Gauss. Isolation Isolation is the measure of the power level at the output connector of an unconnected RF channel as referenced to the power at the input connector. It is specified in dB below the input power level. Switching Time Switching time is the total interval beginning with the arrival of the leading edge of the command pulse at the switch DC input and ending with the completion of the switch transfer, including contact bounce. It consists of three parts: (1) inductive delay in the coil, (2) transfer time of the physical movement of the contacts, and (3) the bounce time of the RF contacts. TTL Switch Driver Option As a special option, switch drivers can be provided for both failsafe and latching switches, which are compatible with industry-standard low-power Schottky TTL circuits. © 2012 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCRS-33S/CRS-33S Page 7 CCRS-33S\CRS-33S\062012\Q2 Series CCRS-33S/CRS-33S Miniature DC–18 GHz Failsafe 2P3T Coaxial Switch COAX SWITCHES FAILSAFE CCRS-33S/CRS-33S PART NUMBER LIST PART NO. * PART NO. 1 CCRS-33SXC 43 CRS-33SXO-MS 2 CCRS-33SXC-D 44 CRS-33SXO-S 3 CCRS-33SXC-DM 45 CRS-33SXO-T 4 CCRS-33SXC-DMS 46 CRS-33SXO-TM 5 CCRS-33SXC-DS 47 CRS-33SXO-TMS 6 CCRS-33SXC-M 48 CRS-33SXO-TS 7 CCRS-33SXC-MS 8 CCRS-33SXC-S 9 CCRS-33SXC-T 10 CCRS-33SXC-TM 11 CCRS-33SXC-TMS 12 CCRS-33SXC-TS 13 CCRS-33SXO 14 CCRS-33SXO-D 15 CCRS-33SXO-DM 16 CCRS-33SXO-DMS 17 CCRS-33SXO-DS 18 CCRS-33SXO-M 19 CCRS-33SXO-MS 20 CCRS-33SXO-S 21 CCRS-33SXO-T 22 CCRS-33SXO-TM 23 CCRS-33SXO-TMS 24 CCRS-33SXO-TS 25 CRS-33SXC 26 CRS-33SXC-D 27 CRS-33SXC-DM 28 CRS-33SXC-DMS 29 CRS-33SXC-DS 30 CRS-33SXC-M 31 CRS-33SXC-MS 32 CRS-33SXC-S 33 CRS-33SXC-T 34 CRS-33SXC-TM 35 CRS-33SXC-TMS 36 CRS-33SXC-TS 37 CRS-33SXO 38 CRS-33SXO-D 39 CRS-33SXO-DM 40 CRS-33SXO-DMS 41 CRS-33SXO-DS 42 CRS-33SXO-M X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc) CCRS-33S/CRS-33S Page 8 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2012 TELEDYNE COAX SWITCHES CCRS-33S\CRS-33S\062012\Q2