defining a degree of excellence POWER LINE CHOKES COMMON MODE CHOKES Power line chokes can be used to minimize EMI radiated noise in the common mode on all power applications. Bel offers a variety of inductances and rated currents, to provide full coverage of power requirements. ELECTRICALS Part Number 0571-0303-00 0571-0203-00 0571-0203-01 0571-0103-00 0571-0083-00 0571-0063-00 0571-0063-01 0571-0043-00 0571-0033-00 0571-0033-01 0571-0023-00 0571-0013-00 TM0029 * 2000 Volts AC for 60 seconds Isolation Voltage. * 250 Volts AC/DC rated voltage. * Insulation Resistance is 100 Mohms minimum at 500 VDC. @ 25o C Rated Inductance DCR OCL Current (ohm/line) (mH) Min I/Line Max 0.40 30.0 2.80 0.40 20.0 2.20 0.50 20.0 1.60 0.60 10.0 1.20 0.80 8.00 0.80 0.80 6.00 0.70 1.00 6.00 0.50 1.00 4.00 0.40 0.75 3.00 1.00 1.20 3.00 0.40 1.20 2.00 0.30 1.50 1.50 0.30 SCHEMATIC 1 3 2 4 1 3 2 4 MECHANICALS 1.10(27.94) 0.90(22.86) 0.028(0.71) Diameter 0.177(4.50) +/- 0.04(1.02) 0.394(10.01) Date Code and Part Number 0.512(13.00) bel 0.75(19.05) Dimensions are in inches(mm) Dimension tolerance is equal to +/- 0.02(0.51) unless otherwise stated. Corporate Office Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302-4496 Tel: 201-432-0463 Fax: 201-432-9542 E-Mail: [email protected] Internet: http://www.belfuse.com Far East Office Bel Fuse Ltd. 8F/8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel: 852-2328-5515 Fax: 852-2352-3706 European Office Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Preston PR1 8UD Lancashire, U.K. Tel: 44-1772-556601 Fax: 44-1772-888366 T204