Cynergy3 D-HR High insulation resistance, high voltage relays -10kv and 15kv Datasheet

D-HR Series
High Insulation Resistance, High Voltage Relays -10kV & 15kV
10kV or 15kV Isolation
Low Contact Resistance
1x1014 Ohms Minimum Insulation Resistance
PCB or Flying Leads Connections
Ideal for sensitive test and measurement circuits
which require low leakage current losses
Contact Specification Unit
Contact Material
Isolation across contacts kV
Switching Power Max. W
Switching Voltage Max. V
Switching Current Max. A
Carry Current Max
A
Capacitance across
pF
contacts
Lifetime
Operations
Very high isolation voltages - up to 15kV are achieved through the use of high
vacuum reed switches with either rhodium
or tungsten contacts which make these
relays suitable for high reliability
applications, such as cardiac
defibrillators, test equipment and high
voltage power supplies.
The rhodium contact relays have low
contact resistance, while the tungsten
contact relays can switch higher voltages.
Condition
DC or AC peak
Contact Resistance
Insulation Resistance
DC or AC peak
DC or AC peak
DC or AC peak
coil to screen
grounded
dry switching
50W switching
mW max (typical)
Wmin
Coil Specification
Must Operate Voltage
Must Release Voltage
Operate Time
Release Time
Resistance
V
V
ms
ms
W
DC
DC
diode fitted
diode fitted
Relay Specification
Isolation contact/coil
kV
Insulation resistance contact
to all terminals
Wmin (typical)
Environmental
Operating Temp range ºC
10kV SPNO
10kV SPNC
Rhodium Tungsten Rhodium Tungsten
10
10
10
10
50
50
50
50
1000
7000
1000
7000
3
2
3
2
4
3
4
3
<0.2
<0.2
<0.2 <0.2
15kV SPNO*
Tungsten
15
50
10000
2
2
<0.2
109
109
109
109
106
106
106
106
50 (15) 250(100) 50 (15) 250(100)
1x1014
1x1014
109
106
250 (100)
1x1014
5V
3.7
0.5
3.0
2.0
28
12V
9
1.25
3.0
2.0
150
24V
20
4
3.0
2.0
780
17
1x10
5V
3.7
0.5
2.0
3.0
38
12V
9
1.25
2.0
3.0
240
24V
20
4
2.0
3.0
925
17
14
-20 to +70
1x10
5V
3.7
0.5
3.0
2.0
16
12V
9
1.25
3.0
2.0
95
24V
20
4
3.0
2.0
350
17
14
1x10
-20 to +70
14
-20 to +70
Part Numbering System
D A T 7 12 10 F-HR
Reed Switch Size
Contact Form A=n/o, B=n/c*
Contact Material
R=Rhodium,
T=Tungsten
Moulding Ref. No.
Coil Voltage
05=5Vdc, 12=12Vdc,
24=24Vdc
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Isolation between
Contacts
10=10kV, 15=15kV
Email:[email protected]
* Form B (n/c) is not available on 15kV models
ISO9001 C E R T I F I E D
Insulation Resistance
-HR = High Insulation
Resistance Version
Mounting or Connection Style
No suffix indicates PCB mount
F= PCB mount with & coil
connection with flying lead HV
connection
www.cynergy3.com
© 2014 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
MECHANICAL
STANDARD
(e.g. DAT71210-HR)
15.8
(0.62")
60.0
(2.36")
CIRCUIT DIAGRAMS
(ALL VARIANTS)
18.5
FORM A (NO)
(0.73")
3
1
2
4.0
4
(0.15") 4 Pins 0.635(0.025”) Square
5.1
FORM B (NC)
(0.2")
3 3
10.2
1
2
2
1
4+
4
(0.4")
25.4
(1.0")
50.8
NOTE: COIL POLARITY IS IMPORTANT
(2.0")
FOR FORM B VARIANT ONLY.
FLYING LEAD
(e.g. DAT71210F-HR)
~300
13.0
1
50.8
(2.0")
2
4 Pins 0.635(0.025”) Square
3
4
NOTE: PINS WHICH ARE NOT NUMBERED
HAVE NO ELECTRICAL CONNECTION.
ISO9001 C E R T I F I E D
www.cynergy3.com
© 2014 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.