AD AD7712AR-REEL Signal conditioning adc Datasheet

LC2MOS
Signal Conditioning ADC
AD7712
FEATURES
Charge Balancing ADC
24 Bits No Missing Codes
ⴞ0.0015% Nonlinearity
High Level and Low Level Analog Input Channels
Programmable Gain for Both Inputs
Gains from 1 to 128
Differential Input for Low Level Channel
Low-Pass Filter with Programmable Filter Cutoffs
Ability to Read/Write Calibration Coefficients
Bidirectional Microcontroller Serial Interface
Internal/External Reference Option
Single- or Dual-Supply Operation
Low Power (25 mW typ) with Power-Down Mode
(100 ␮W typ)
APPLICATIONS
Process Control
Smart Transmitters
Portable Industrial Instruments
FUNCTIONAL BLOCK DIAGRAM
REF REF
AVDD DVDD IN (–) IN (+)
VBIAS
AVDD
2.5V REFERENCE
4.5␮A
AIN1(+)
AIN1(–)
REF OUT
M
U
X
CHARGE-BALANCING A/D
CONVERTER
AUTO-ZEROED
⌺–⌬
MODULATOR
PGA
DIGITAL
FILTER
SYNC
STANDBY
A = 1 – 128
AIN2
CLOCK
GENERATION
VOLTAGE
ATTENUATION
MCLK
IN
MCLK
OUT
SERIAL INTERFACE
TP
AD7712
CONTROL
REGISTER
OUTPUT
REGISTER
AGND DGND VSS RFS TFS MODE SDATA SCLK DRDY A0
GENERAL DESCRIPTION
The AD7712 is a complete analog front end for low frequency
measurement applications. The device has two analog input
channels and accepts either low level signals directly from a transducer or high level (± 4 ⫻ VREF) signals, and outputs a serial
digital word. It employs a sigma-delta conversion technique to
realize up to 24 bits of no missing codes performance. The low
level input signal is applied to a proprietary programmable gain
front end based around an analog modulator. The high level
analog input is attenuated before being applied to the same
modulator. The modulator output is processed by an on-chip
digital filter. The first notch of this digital filter can be programmed
via the on-chip control register, allowing adjustment of the filter
cutoff and settling time.
Normally, one of the channels will be used as the main channel
with the second channel used as an auxiliary input to periodically measure a second voltage. The part can be operated from a
single supply (by tying the VSS pin to AGND), provided that the
input signals on the low level analog input are more positive
than –30 mV. By taking the VSS pin negative, the part can convert signals down to –VREF on this low level input. This low level
input, as well as the reference input, features differential input
capability.
The AD7712 is ideal for use in smart, microcontroller based
systems. Input channel selection, gain settings, and signal polarity can be configured in software using the bidirectional serial
port. The AD7712 also contains self-calibration, system calibration, and background calibration options, and allows the user to
read and to write the on-chip calibration registers.
CMOS construction ensures low power dissipation, and a hardware programmable power-down mode reduces the standby power
consumption to only 100 µW typical. The part is available in a
24-lead, 0.3 inch wide, plastic and hermetic dual-in-line package (DIP), as well as a 24-lead small outline (SOIC) package.
PRODUCT HIGHLIGHTS
1. The low level analog input channel allows the AD7712 to
accept input signals directly from a strain gage or transducer,
removing a considerable amount of signal conditioning. To
maximize the flexibility of the part, the high level analog
input accepts signals of ± 4 ⫻ VREF/GAIN.
2. The AD7712 is ideal for microcontroller or DSP processor
applications with an on-chip control register that allows
control over filter cutoff, input gain, channel selection, signal
polarity, and calibration modes.
3. The AD7712 allows the user to read and to write the on-chip
calibration registers. This means that the microcontroller has
much greater control over the calibration procedure.
4. No missing codes ensures true, usable, 23-bit dynamic range
coupled with excellent ± 0.0015% accuracy. The effects of
temperature drift are eliminated by on-chip self-calibration,
which removes zero-scale and full-scale errors.
REV. F
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties that
may result from its use. No license is granted by implication or otherwise
under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
www.analog.com
Fax: 781/326-8703
© 2004 Analog Devices, Inc. All rights reserved.
AD7712* PRODUCT PAGE QUICK LINKS
Last Content Update: 02/23/2017
COMPARABLE PARTS
REFERENCE MATERIALS
View a parametric search of comparable parts.
Technical Articles
• Delta-Sigma Rocks RF, As ADC Designers Jump On Jitter
EVALUATION KITS
• MS-2210: Designing Power Supplies for High Speed ADC
• AD7712 Evaluation Board
• Part 1: Circuit Suggestions Using Features and
Functionality of New Sigma-Delta ADCs
DOCUMENTATION
Application Notes
• Part 2: Circuit Suggestions Using Features and
Functionality of New Sigma-Delta ADCs
• AN-202: An IC Amplifier User’s Guide to Decoupling,
Grounding, and Making Things Go Right for a Change
DESIGN RESOURCES
• AN-283: Sigma-Delta ADCs and DACs
• AD7712 Material Declaration
• AN-311: How to Reliably Protect CMOS Circuits Against
Power Supply Overvoltaging
• PCN-PDN Information
• AN-388: Using Sigma-Delta Converters-Part 1
• Symbols and Footprints
• Quality And Reliability
• AN-389: Using Sigma-Delta Converters-Part 2
• AN-397: Electrically Induced Damage to Standard Linear
Integrated Circuits:
• AN-406: Using the AD771X Family of 24-Bit Sigma-Delta
A/D Converters
DISCUSSIONS
View all AD7712 EngineerZone Discussions.
SAMPLE AND BUY
• AN-553: Adjusting the Calibration Coefficients on the
AD771X Family of ADCs
Visit the product page to see pricing options.
• AN-607: Selecting a Low Bandwidth (<15 kSPS) SigmaDelta ADC
TECHNICAL SUPPORT
• AN-615: Peak-to-Peak Resolution Versus Effective
Resolution
Submit a technical question or find your regional support
number.
Data Sheet
• AD7712: LC2MOS Signal Conditioning ADC Data Sheet
DOCUMENT FEEDBACK
Submit feedback for this data sheet.
TOOLS AND SIMULATIONS
• Sigma-Delta ADC Tutorial
This page is dynamically generated by Analog Devices, Inc., and inserted into this data sheet. A dynamic change to the content on this page will not
trigger a change to either the revision number or the content of the product data sheet. This dynamic page may be frequently modified.
(AV = +5 V ⴞ 5%; DV = +5 V ⴞ 5%; V = 0 V or –5 V ⴞ 5%; REF IN(+) = +2.5 V;
AD7712–SPECIFICATIONS
REF IN(–) = AGND; MCLK IN = 10 MHz unless otherwise stated. All specifications T to T , unless otherwise noted.)
DD
DD
SS
MIN
Parameter
STATIC PERFORMANCE
No Missing Codes
Output Noise
Integral Nonlinearity @ 25°C
TMIN to TMAX
Positive Full-Scale Error2, 3, 4
Full-Scale Drift5
Unipolar Offset Error2, 4
Unipolar Offset Drift5
Bipolar Zero Error2, 4
Bipolar Zero Drift5
Gain Drift
Bipolar Negative Full-Scale Error2 @ 25°C
TMIN to TMAX
Bipolar Negative Full-Scale Drift5
ANALOG INPUTS/REFERENCE INPUTS
Normal-Mode 50 Hz Rejection6
Normal-Mode 60 Hz Rejection6
AIN1/REF IN
DC Input Leakage Current @ 25°C6
TMIN to TMAX
Sampling Capacitance6
Common-Mode Rejection (CMR)
Common-Mode 50 Hz Rejection6
Common-Mode 60 Hz Rejection6
Common-Mode Voltage Range7
Analog Inputs8
Input Sampling Rate, fS
AIN1 Input Voltage Range9
AIN2 Input Voltage Range9
AIN2 DC Input Impedance
AIN2 Gain Error11
AIN2 Gain Drift
AIN2 Offset Error11
AIN2 Offset Drift
Reference Inputs
REF IN(+) – REF IN(–) Voltage12
Input Sampling Rate, fS
MAX
A, S Versions1
Unit
Conditions/Comments
24
22
18
15
12
See Tables I and II
± 0.0015
± 0.003
Bits min
Bits min
Bits min
Bits min
Bits min
% FSR max
% FSR max
1
0.3
µV/°C typ
µV/°C typ
Guaranteed by Design. For Filter Notches ≤ 60 Hz
For Filter Notch = 100 Hz
For Filter Notch = 250 Hz
For Filter Notch = 500 Hz
For Filter Notch = 1 kHz
Depends on Filter Cutoffs and Selected Gain
Filter Notches ≤ 60 Hz
Typically ± 0.0003%
Excluding Reference
Excluding Reference. For Gains of 1, 2
Excluding Reference. For Gains of 4, 8, 16, 32, 64, 128
0.5
0.25
µV/°C typ
µV/°C typ
For Gains of 1, 2
For Gains of 4, 8, 16, 32, 64, 128
0.5
0.25
2
± 0.003
± 0.006
1
0.3
µV/°C typ
µV/°C typ
ppm/°C typ
% FSR max
% FSR max
µV/°C typ
µV/°C typ
For Gains of 1, 2
For Gains of 4, 8, 16, 32, 64, 128
Excluding Reference
Typically ± 0.0006%
Excluding Reference. For Gains of 1, 2
Excluding Reference. For Gains of 4, 8, 16, 32, 64, 128
100
100
dB min
dB min
For Filter Notches of 10 Hz, 25 Hz, 50 Hz, ± 0.02 ⫻ fNOTCH
For Filter Notches of 10 Hz, 30 Hz, 60 Hz, ± 0.02 ⫻ fNOTCH
10
1
20
100
90
150
150
VSS to AVDD
pA max
nA max
pF max
dB min
dB min
dB min
dB min
V min to V max
At dc and AVDD = 5 V
At dc and AVDD = 10 V
For Filter Notches of 10 Hz, 25 Hz, 50 Hz, ± 0.02 ⫻ fNOTCH
For Filter Notches of 10 Hz, 30 Hz, 60 Hz, ± 0.02 ⫻ fNOTCH
See Table III
0 V to VREF10
± VREF
V max
V max
0 V to 4 ⫻ VREF10
± 4 ⫻ VREF
30
± 0.05
1
10
20
V max
V max
kΩ
% typ
ppm/°C typ
mV max
µV/°C typ
2.5 to 5
V min to V max
For Normal Operation. Depends on Gain Selected
Unipolar Input Range (B/U Bit of Control Register = 1)
Bipolar Input Range (B/U Bit of Control Register = 0)
For Normal Operation. Depends on Gain Selected
Unipolar Input Range (B/U Bit of Control Register = 1)
Bipolar Input Range (B/U Bit of Control Register = 0)
Additional Error Contributed by Resistor Attenuator
Additional Drift Contributed by Resistor Attenuator
Additional Error Contributed by Resistor Attenuator
For Specified Performance. Part Is Functional with
Lower VREF Voltages
fCLK IN/256
NOTES
1
Temperature range is as follows: A Version, –40°C to +85°C; S Version –55°C to +125°C. See also Note 18.
2
Applies after calibration at the temperature of interest.
3
Positive full-scale error applies to both unipolar and bipolar input ranges.
4
These errors will be of the order of the output noise of the part as shown in Table I after system calibration. These errors will be 20 µV typical after self-calibration
or background calibration.
5
Recalibration at any temperature or use of the background calibration mode will remove these drift errors.
6
These numbers are guaranteed by design and/or characterization.
7
This common-mode voltage range is allowed, provided that the input voltage on AIN1(+) and AIN1(–) does not exceed AV DD + 30 mV and V SS – 30 mV.
8
The AIN1 analog input presents a very high impedance dynamic load that varies with clock frequency and input sample rate. The maximum recommended
source resistance depends on the selected gain (see Tables IV and V).
9
The analog input voltage range on the AIN1(+) input is given here with respect to the voltage on the AIN1(–) input. The input voltage range on the AIN2
input is with respect to AGND. The absolute voltage on the AIN1 input should not go more positive than AV DD + 30 mV or more negative than V SS – 30 mV.
10
VREF = REF IN(+) – REF IN(–).
11
This error can be removed using the system calibration capabilities of the AD7712. This error is not removed by the AD7712’s self-calibration features. The offset
drift on the AIN2 input is 4 times the value given in the Static Performance section.
12
The reference input voltage range may be restricted by the input voltage range requirement on the V BIAS input.
–2–
REV. F
AD7712
SPECIFICATIONS (continued)
Parameter
A, S Versions1
Unit
Conditions/Comments
REFERENCE OUTPUT
Output Voltage
Initial Tolerance
Drift
Output Noise
Line Regulation (AVDD)
Load Regulation
External Current
2.5
±1
20
30
1
1.5
1
V nom
% max
ppm/°C typ
µV typ
mV/V max
mV/mA max
mA max
pk-pk Noise; 0.1 Hz to 10 Hz Bandwidth
AVDD – 0.85 ⫻ VREF
or AVDD – 3.5
V max
VBIAS INPUT13
Input Voltage Range
Maximum Load Current 1 mA
See VBIAS Input Section
Whichever Is Smaller: +5 V/–5 V or +10 V/0 V
Nominal AVDD/VSS
Whichever Is Smaller: +5 V/0 V Nominal AVDD/VSS
See VBIAS Input Section
Whichever Is Greater: +5 V/–5 V or +10 V/0 V
Nominal AVDD/VSS
Whichever Is Greater: +5 V/0 V Nominal AVDD/VSS
Increasing with Gain
or AVDD – 2.1
VSS + 0.85 ⫻ VREF
or VSS + 3
V max
or VSS + 2.1
65 to 85
V min
dB typ
± 10
µA max
0.8
2.0
V max
V min
0.8
3.5
V max
V min
LOGIC OUTPUTS
VOL, Output Low Voltage
VOH, Output High Voltage
Floating State Leakage Current
Floating State Output Capacitance14
0.4
4.0
± 10
9
V max
V min
µA max
pF typ
TRANSDUCER BURNOUT
Current
Initial Tolerance
Drift
4.5
± 10
0.1
µA nom
% typ
%/°C typ
(1.05 ⫻ VREF)/GAIN
–(1.05 ⫻ VREF)/GAIN
–(1.05 ⫻ VREF)/GAIN
0.8 ⫻ VREF/GAIN
(2.1 ⫻ VREF)/GAIN
V max
V max
V max
V min
V max
GAIN Is the Selected PGA Gain (Between 1 and 128)
GAIN Is the Selected PGA Gain (Between 1 and 128)
GAIN Is the Selected PGA Gain (Between 1 and 128)
GAIN Is the Selected PGA Gain (Between 1 and 128)
GAIN Is the Selected PGA Gain (Between 1 and 128)
(4.2 ⫻ VREF)/GAIN
–(4.2 ⫻ VREF)/GAIN
–(4.2 ⫻ VREF)/GAIN
3.2 ⫻ VREF/GAIN
(8.4 ⫻ VREF)/GAIN
V max
V max
V max
V min
V max
GAIN Is the Selected PGA Gain (Between 1 and 128)
GAIN Is the Selected PGA Gain (Between 1 and 128)
GAIN Is the Selected PGA Gain (Between 1 and 128)
GAIN Is the Selected PGA Gain (Between 1 and 128)
GAIN Is the Selected PGA Gain (Between 1 and 128)
VBIAS Rejection
LOGIC INPUTS
Input Current
All Inputs except MCLK IN
VINL, Input Low Voltage
VINH, Input High Voltage
MCLK IN Only
VINL, Input Low Voltage
VINH, Input High Voltage
SYSTEM CALIBRATION
AIN1
Positive Full-Scale Calibration Limit15
Negative Full-Scale Calibration Limit15
Offset Calibration Limit16, 17
Input Span15
AIN2
Positive Full-Scale Calibration Limit15
Negative Full-Scale Calibration Limit15
Offset Calibration Limit17
Input Span15
V min
ISINK = 1.6 mA
ISOURCE = 100 µA
NOTES
13
The AD7712 is tested with the following V BIAS voltages. With AV DD = 5 V and V SS = 0 V, VBIAS = 2.5 V; with AVDD = 10 V and VSS = 0 V, VBIAS = 5 V and
with AVDD = 5 V and VSS = –5 V, VBIAS = 0 V.
14
Guaranteed by design, not production tested.
15
After calibration, if the analog input exceeds positive full scale, the converter will output all 1s. If the analog input is less than negative full scale, then the device will
output all 0s.
16
These calibration and span limits apply provided the absolute voltage on the AIN1 analog inputs does not exceed AV DD + 30 mV or does not go more negative
than VSS – 30 mV.
17
The offset calibration limit applies to both the unipolar zero point and the bipolar zero point.
REV. F
–3–
AD7712–SPECIFICATIONS
Parameter
POWER REQUIREMENTS
Power Supply Voltages
AVDD Voltage18
DVDD Voltage19
AVDD – VSS Voltage
Power Supply Currents
AVDD Current
DVDD Current
VSS Current
Power Supply Rejection 20
Positive Supply (AVDD and DVDD)21
Negative Supply (VSS)
Power Dissipation
Normal Mode
Normal Mode
Standby (Power-Down) Mode 22
A, S Versions1
Unit
Conditions/Comments
+5 to +10
+5
+10.5
V nom
V nom
V max
± 5% for Specified Performance
± 5% for Specified Performance
For Specified Performance
4
4.5
1.5
mA max
mA max
mA max
90
dB typ
dB typ
45
52.5
200
mW max
mW max
µW max
VSS = –5 V
Rejection w.r.t. AGND; Assumes V BIAS Is Fixed
AVDD = DVDD = +5 V, VSS = 0 V; Typically 25 mW
AVDD = DVDD = +5 V, VSS = –5 V; Typically 30 mW
AVDD = DVDD = +5 V, VSS = 0 V or –5 V; Typically 100 µW
NOTES
18
The AD7712 is specified with a 10 MHz clock for AV DD voltages of +5 V ± 5%. It is specified with an 8 MHz clock for AV DD voltages greater than 5.25 V and less
than 10.5 V. Operating with AV DD voltages in the range 5.25 V to 10.5 V is guaranteed only over the 0⬚C to 70⬚C temperature range.
19
The ± 5% tolerance on the DV DD input is allowed provided that DV DD does not exceed AV DD by more than 0.3 V.
20
Measured at dc and applies in the selected passband. PSRR at 50 Hz will exceed 120 dB with filter notches of 10 Hz, 25 Hz, or 50 Hz. PSRR at 60 Hz will
exceed 120 dB with filter notches of 10 Hz, 30 Hz, or 60 Hz.
21
PSRR depends on gain: gain of 1 = 70 dB typ; gain of 2 = 75 dB typ; gain of 4 = 80 dB typ; gains of 8 to 128 = 85 dB typ. These numbers can be improved
(to 95 dB typ) by deriving the V BIAS voltage (via Zener diode or reference) from the AV DD supply.
22
Using the hardware STANDBY pin. Standby power dissipation using the software standby bit (PD) of the Control Register is 8 mW typ.
Specifications subject to change without notice.
Digital Input Voltage to DGND . . . . . –0.3 V to AVDD + 0.3 V
Digital Output Voltage to DGND . . . . –0.3 V to DVDD + 0.3 V
Operating Temperature Range
Commercial (A Version) . . . . . . . . . . . . . . . –40°C to +85°C
Extended (S Version) . . . . . . . . . . . . . . . . . –55°C to +125°C
Storage Temperature Range . . . . . . . . . . . . . –65°C to +150°C
Lead Temperature (Soldering, 10 secs) . . . . . . . . . . . . . 300°C
Power Dissipation (Any Package) to 75°C . . . . . . . . . . 450 mW
ABSOLUTE MAXIMUM RATINGS*
(TA = 25°C, unless otherwise noted.)
AVDD to DVDD . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
AVDD to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
AVDD to AGND . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
AVDD to DGND . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
DVDD to AGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
DVDD to DGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
VSS to AGND . . . . . . . . . . . . . . . . . . . . . . . . . +0.3 V to –6 V
VSS to DGND . . . . . . . . . . . . . . . . . . . . . . . . . +0.3 V to –6 V
AIN1 Input Voltage to AGND . . . VSS – 0.3 V to AVDD + 0.3 V
Reference Input Voltage to AGND . . VSS – 0.3 V to AVDD + 0.3 V
REF OUT to AGND . . . . . . . . . . . . . . . . . . . . –0.3 V to AVDD
*Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of the specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
ORDERING GUIDE
Model
Temperature Range Package Options*
AD7712AN
AD7712AR
AD7712AR-REEL
AD7712AR-REEL7
AD7712AQ
AD7712SQ
EVAL-AD7712EB
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–55°C to +125°C
Evaluation Board
N-24
RW-24
RW-24
RW-24
Q-24
Q-24
*N = PDIP, Q = CERDIP; RW = SOIC.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD7712 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
–4–
REV. F
AD7712
TIMING
3
DD = +5 V ⴞ 5%; AVDD = +5 V or +10 V ⴞ 5%; VSS = 0 V or –5 V ⴞ 5%; AGND = DGND =
1, 2 (DV
CHARACTERISTICS 0 V; fCLKIN =10 MHz; Input Logic 0 = 0 V, Logic 1 = DVDD, unless otherwise noted.)
Parameter
fCLK IN
Limit at TMIN, TMAX
(A, S Versions)
Unit
Conditions/Comments
400
10
8
0.4 ⫻ tCLK IN
0.4 ⫻ tCLK IN
50
50
1000
kHz min
MHz max
MHz
ns min
ns min
ns max
ns max
ns min
Master Clock Frequency: Crystal Oscillator or
Externally Supplied
AVDD = 5 V ± 5%
For Specified Performance
AVDD = 5.25 V to 10.5 V
Master Clock Input Low Time; tCLK IN = 1/fCLK IN
Master Clock Input High Time
Digital Output Rise Time; Typically 20 ns
Digital Output Fall Time; Typically 20 ns
SYNC Pulse Width
0
0
2 ⫻ tCLK IN
0
4 ⫻ tCLK IN + 20
4 ⫻ tCLK IN + 20
tCLK IN/2
tCLK IN/2 + 30
tCLK IN/2
3 ⫻ tCLK IN/2
50
0
4 ⫻ tCLK IN + 20
4 ⫻ tCLK IN
0
10
ns min
ns min
ns min
ns min
ns max
ns max
ns min
ns max
ns nom
ns nom
ns min
ns min
ns max
ns min
ns min
ns min
4, 5
tCLK IN LO
tCLK IN HI
tr6
tf 6
t1
Self-Clocking Mode
t2
t3
t4
t5
t6
t7 7
t8 7
t9
t10
t14
t15
t16
t17
t18
t19
DRDY to RFS Setup Time; tCLK IN = 1/fCLK IN
DRDY to RFS Hold Time
A0 to RFS Setup Time
A0 to RFS Hold Time
RFS Low to SCLK Falling Edge
Data Access Time (RFS Low to Data Valid)
SCLK Falling Edge to Data Valid Delay
SCLK High Pulse Width
SCLK Low Pulse Width
A0 to TFS Setup Time
A0 to TFS Hold Time
TFS to SCLK Falling Edge Delay Time
TFS to SCLK Falling Edge Hold Time
Data Valid to SCLK Setup Time
Data Valid to SCLK Hold Time
NOTES
1
Guaranteed by design, not production tested. Sample tested during initial release and after any redesign or process change that may affect this parameter. All input
signals are specified with tr = tf = 5 ns (10% to 90% of 5 V) and timed from a voltage level of 1.6 V.
2
See Figures 11 to 14.
3
The AD7712 is specified with a 10 MHz clock for AV DD voltages of 5 V ± 5%. It is specified with an 8 MHz clock for AV DD voltages greater than 5.25 V and less
than 10.5 V.
4
CLK IN duty cycle range is 45% to 55%. CLK IN must be supplied whenever the AD7712 is not in STANDBY mode. If no clock is present in this case, the
device can draw higher current than specified and possibly become uncalibrated.
5
The AD7712 is production tested with f CLK IN at 10 MHz (8 MHz for AV DD < 5.25 V). It is guaranteed by characterization to operate at 400 kHz.
6
Specified using 10% and 90% points on waveform of interest.
7
These numbers are measured with the load circuit of Figure 1 and defined as the time required for the output to cross 0.8 V or 2.4 V.
REV. F
–5–
AD7712
TIMING CHARACTERISTICS (continued)
Parameter
External Clocking Mode
fSCLK
t20
t21
t22
t23
t247
t257
t26
t27
t28
t298
t30
t318
t32
t33
t34
t35
t36
Limit at TMIN, TMAX
(A, S Versions)
Unit
Conditions/Comments
fCLK IN/5
0
0
2 ⫻ tCLK IN
0
4 ⫻ tCLK IN
10
2 ⫻ tCLK IN + 20
2 ⫻ tCLK IN
2 ⫻ tCLK IN
tCLK IN + 10
10
tCLK IN + 10
10
5 ⫻ tCLK IN/2 + 50
0
0
4 ⫻ tCLK IN
2 ⫻ tCLK IN – SCLK High
30
MHz max
ns min
ns min
ns min
ns min
ns max
ns min
ns max
ns min
ns min
ns max
ns min
ns max
ns min
ns max
ns min
ns min
ns min
ns min
ns min
Serial Clock Input Frequency
DRDY to RFS Setup Time
DRDY to RFS Hold Time
A0 to RFS Setup Time
A0 to RFS Hold Time
Data Access Time (RFS Low to Data Valid)
SCLK Falling Edge to Data Valid Delay
SCLK High Pulse Width
SCLK Low Pulse Width
SCLK Falling Edge to DRDY High
SCLK to Data Valid Hold Time
RFS/TFS to SCLK Falling Edge Hold Time
RFS to Data Valid Hold Time
A0 to TFS Setup Time
A0 to TFS Hold Time
SCLK Falling Edge to TFS Hold Time
Data Valid to SCLK Setup Time
Data Valid to SCLK Hold Time
NOTES
8
These numbers are derived from the measured time taken by the data output to change 0.5 V when loaded with the circuit of Figure 1. The measured number
is then extrapolated back to remove effects of charging or discharging the 100 pF capacitor. This means that the times quoted in the timing characteristics are
the true bus relinquish times of the part and, as such, are independent of external bus loading capacitances.
Specifications subject to change without notice.
PIN CONFIGURATION
DIP and SOIC
1.6mA
TO OUTPUT
PIN
2.1V
100pF
200␮A
Figure 1. Load Circuit for Access Time and
Bus Relinquish Time
SCLK
1
24 DGND
MCLK IN
2
23 DVDD
MCLK OUT
3
22 SDATA
A0
4
21 DRDY
SYNC
5
MODE
6
20
RFS
AIN1(+)
TOP VIEW 19 TFS
7 (Not to Scale) 18 AGND
AIN1(–)
8
17 AIN2
STANDBY
9
16 REF OUT
TP 10
15 REF IN(+)
VSS 11
14 REF IN(–)
AVDD 12
–6–
AD7712
13 VBIAS
REV. F
AD7712
PIN FUNCTION DESCRIPTION
Pin Mnemonic
Function
1
SCLK
Serial Clock. Logic input/output, depending on the status of the MODE pin. When MODE is high, the
device is in its self-clocking mode, and the SCLK pin provides a serial clock output. This SCLK becomes
active when RFS or TFS goes low, and it goes high impedance when either RFS or TFS returns high or when
the device has completed transmission of an output word. When MODE is low, the device is in its external
clocking mode, and the SCLK pin acts as an input. This input serial clock can be a continuous clock with all
data transmitted in a continuous train of pulses. Alternatively, it can be a noncontinuous clock with the
information being transmitted to the AD7712 in smaller batches of data.
2
MCLK IN
Master Clock Signal for the Device. This can be provided in the form of a crystal or external clock. A crystal can
be tied across the MCLK IN and MCLK OUT pins. Alternatively, the MCLK IN pin can be driven with a
CMOS-compatible clock and MCLK OUT left unconnected. The clock input frequency is nominally 10 MHz.
3
MCLK OUT
When the master clock for the device is a crystal, the crystal is connected between MCLK IN and MCLK OUT.
4
A0
Address Input. With this input low, reading and writing to the device is to the control register. With this input
high, access is to either the data register or the calibration registers.
5
SYNC
Logic Input. Allows for synchronization of the digital filters when using a number of AD7712s. It resets
the nodes of the digital filter.
6
MODE
Logic Input. When this pin is high, the device is in its self-clocking mode. With this pin low, the device is in its
external clocking mode.
7
AIN1(+)
Analog Input Channel 1. Positive input of the programmable gain differential analog input. The AIN1(+) input
is connected to an output current source that can be used to check that an external transducer has burned out
or gone open circuit. This output current source can be turned on/off via the control register.
8
AIN1(–)
Analog Input Channel 1. Negative input of the programmable gain differential analog input.
9
STANDBY
Logic Input. Taking this pin low shuts down the internal analog and digital circuitry, reducing power
consumption to less than 50 µW.
10
TP
Test Pin. Used when testing the device. Do not connect anything to this pin.
11
VSS
Analog Negative Supply, 0 V to –5 V. Tied to AGND for single-supply operation. The input voltage on AIN1
should not go > 30 mV negative w.r.t. VSS for correct operation of the device.
12
AVDD
Analog Positive Supply Voltage, 5 V to 10 V.
13
VBIAS
Input Bias Voltage. This input voltage should be set such that VBIAS + 0.85 ⫻ VREF < AVDD and VBIAS – 0.85
⫻ VREF > VSS where VREF is REF IN(+) – REF IN(–). Ideally, this should be tied halfway between AVDD
and VSS. Thus, with AVDD = +5 V and VSS = 0 V, it can be tied to REF OUT; with AVDD = +5 V and VSS =
–5 V, it can be tied to AGND, while with AVDD = +10 V, it can be tied to +5 V.
14
REF IN(–)
Reference Input. The REF IN(–) can lie anywhere between AVDD and VSS provided REF IN(+) is greater
than REF IN(–).
15
REF IN(+)
Reference Input. The reference input is differential providing that REF IN(+) is greater than REF IN(–).
REF IN(+) can lie anywhere between AVDD and VSS.
16
REF OUT
Reference Output. The internal 2.5 V reference is provided at this pin. This is a single-ended output
that is referred to AGND.
17
AIN2
Analog Input Channel 2. High level analog input that accepts an analog input voltage range of ± 4 ⫻
VREF/GAIN. At the nominal VREF of +2.5 V and a gain of 1, the AIN2 input voltage range is ± 10 V.
18
AGND
Ground Reference Point for Analog Circuitry.
19
TFS
Transmit Frame Synchronization. Active low logic input used to write serial data to the device with serial
data expected after the falling edge of this pulse. In the self-clocking mode, the serial clock becomes active
after TFS goes low. In the external clocking mode, TFS must go low before the first bit of the data-word
is written to the part.
20
RFS
Receive Frame Synchronization. Active low logic input used to access serial data from the device. In the
self-clocking mode, both the SCLK and SDATA lines become active after RFS goes low. In the external
clocking mode, the SDATA line becomes active after RFS goes low.
REV. F
–7–
AD7712
Pin Mnemonic
Function
21
DRDY
Logic Output. A falling edge indicates that a new output word is available for transmission. The DRDY pin
will return high upon completion of transmission of a full output word. DRDY is also used to indicate
when the AD7712 has completed its on-chip calibration sequence.
22
SDATA
Serial Data. Input/output with serial data being written to either the control register or the calibration
registers and serial data being accessed from the control register, calibration registers, or the data register.
During an output data read operation, serial data becomes active after RFS goes low (provided DRDY is
low). During a write operation, valid serial data is expected on the rising edges of SCLK when TFS is low.
The output data coding is natural binary for unipolar inputs and offset binary for bipolar inputs.
23
DVDD
Digital Supply Voltage, 5 V. DVDD should not exceed AVDD by more than 0.3 V in normal operation.
24
DGND
Ground Reference Point for Digital Circuitry.
Positive Full-Scale Overrange
TERMINOLOGY
Integral Nonlinearity
Positive full-scale overrange is the amount of overhead available
to handle input voltages on AIN1(+) input greater than
(AIN1(–) + VREF/GAIN) or on the AIN2 of greater than +4 ⫻
VREF/GAIN (for example, noise peaks or excess voltages due to
system gain errors in system calibration routines) without introducing errors due to overloading the analog modulator or to
overflowing the digital filter.
This is the maximum deviation of any code from a straight line
passing through the endpoints of the transfer function. The endpoints of the transfer function are zero-scale (not to be confused
with bipolar zero), a point 0.5 LSB below the first code transition (000 . . . 000 to 000 . . . 001) and full scale, a point 0.5 LSB
above the last code transition (111 . . . 110 to 111 . . . 111). The
error is expressed as a percentage of full scale.
Negative Full-Scale Overrange
Positive full-scale error is the deviation of the last code transition (111 . . . 110 to 111 . . . 111) from the ideal input full-scale
voltage. For AIN1(+), the ideal full-scale input voltage is
(AIN1(–) + VREF/GAIN – 3/2 LSBs); for AIN2, the ideal fullscale voltage is +4 ⫻ VREF/GAIN – 3/2 LSBs. Positive full-scale
error applies to both unipolar and bipolar analog input ranges.
This is the amount of overhead available to handle voltages on
AIN1(+) below (AIN1(–) – VREF/GAIN) or on AIN2 below
–4 ⫻ VREF/GAIN without overloading the analog modulator or
overflowing the digital filter. Note that the analog input will
accept negative voltage peaks on AIN1(+) even in the unipolar
mode provided that AIN1(+) is greater than AIN1(–) and greater
than VSS – 30 mV.
Unipolar Offset Error
Offset Calibration Range
Unipolar offset error is the deviation of the first code transition
from the ideal voltage. For AIN1(+), the ideal input voltage is
(AIN1(–) + 0.5 LSB); for AIN2, the ideal input is 0.5 LSB
when operating in the unipolar mode.
In the system calibration modes, the AD7712 calibrates its
offset with respect to the analog input. The offset calibration
range specification defines the range of voltages that the AD7712
can accept and still accurately calibrate offset.
Bipolar Zero Error
Full-Scale Calibration Range
This is the deviation of the midscale transition (0111 . . . 111
to 1000 . . . 000) from the ideal input voltage. For AIN1(+), the
ideal input voltage is (AIN1(–) – 0.5 LSB); for AIN2, the ideal
input is –0.5 LSB when operating in the bipolar mode.
This is the range of voltages that the AD7712 can accept in the
system calibration mode and still correctly calibrate full scale.
Positive Full-Scale Error
Input Span
In system calibration schemes, two voltages applied in sequence
to the AD7712’s analog input define the analog input range.
The input span specification defines the minimum and maximum input voltages from zero to full scale that the AD7712 can
accept and still accurately calibrate gain.
Bipolar Negative Full-Scale Error
This is the deviation of the first code transition from the ideal
input voltage. For AIN1(+), the ideal input voltage is (AIN1(–)
– VREF/GAIN + 0.5 LSB); for AIN2, the ideal input voltage is
(–4 ⫻ VREF/GAIN + 0.5 LSB) when operating in the bipolar
mode.
–8–
REV. F
AD7712
Control Register (24 Bits)
A write to the device with the A0 input low writes data to the control register. A read to the device with the A0 input low accesses the
contents of the control register. The control register is 24 bits wide and when writing to the register 24 bits of data must be written
otherwise the data will not be loaded to the control register. In other words, it is not possible to write just the first 12 bits of data into
the control register. If more than 24 clock pulses are provided before TFS returns high, then all clock pulses after the 24th clock
pulse are ignored. Similarly, a read operation from the control register should access 24 bits of data.
MSB
MD2
MD1
MD0
G2
G1
G0
CH
PD
WL
X
BO
B/U
FS11
FS10
FS9
FS8
FS7
FS6
FS5
FS4
FS3
FS2
FS1
FS0
X = Don’t Care.
LSB
Operating Mode
MD2
MD1
MD0
Operating Mode
0
0
0
Normal Mode. This is the normal mode of operation of the device whereby a read to the device accesses
data from the data register. This is the default condition of these bits after the internal power-on reset.
0
0
1
Activate Self-Calibration. This activates self-calibration on the channel selected by CH. This is a one-step
calibration sequence, and when complete, the part returns to normal mode (with MD2, MD1, MD0 of
the control registers returning to 0, 0, 0). The DRDY output indicates when this self-calibration is complete.
For this calibration type, the zero-scale calibration is done internally on shorted (zeroed) inputs, and the
full-scale calibration is done on VREF.
0
1
0
Activate System Calibration. This activates system calibration on the channel selected by CH. This is a
two-step calibration sequence, with the zero-scale calibration done first on the selected input channel and
DRDY indicating when this zero-scale calibration is complete. The part returns to normal mode at the
end of this first step in the two-step sequence.
0
1
1
Activate System Calibration. This is the second step of the system calibration sequence with full-scale
calibration being performed on the selected input channel. Once again, DRDY indicates when the fullscale calibration is complete. When this calibration is complete, the part returns to normal mode.
1
0
0
Activate System Offset Calibration. This activates system offset calibration on the channel selected by
CH. This is a one-step calibration sequence and, when complete, the part returns to normal mode with
DRDY indicating when this system offset calibration is complete. For this calibration type, the zero-scale
calibration is done on the selected input channel, and the full-scale calibration is done internally on VREF.
1
0
1
Activate Background Calibration. This activates background calibration on the channel selected by CH. If
the background calibration mode is on, then the AD7712 provides continuous self-calibration of the
reference and shorted (zeroed) inputs. This calibration takes place as part of the conversion sequence,
extending the conversion time and reducing the word rate by a factor of 6. Its major advantage is that
the user does not have to worry about recalibrating the device when there is a change in the ambient
temperature. In this mode, the shorted (zeroed) inputs and VREF, as well as the analog input voltage, are
continuously monitored, and the calibration registers of the device are automatically updated.
1
1
0
Read/Write Zero-Scale Calibration Coefficients. A read to the device with A0 high accesses the contents
of the zero-scale calibration coefficients of the channel selected by CH. A write to the device with A0 high
writes data to the zero-scale calibration coefficients of the channel selected by CH. The word length for
reading and writing these coefficients is 24 bits, regardless of the status of the WL bit of the control
register. Therefore, when writing to the calibration register, 24 bits of data must be written; otherwise the
new data will not be transferred to the calibration register.
1
1
1
Read/Write Full-Scale Calibration Coefficients. A read to the device with A0 high accesses the contents of
the full-scale calibration coefficients of the channel selected by CH. A write to the device with A0 high
writes data to the full-scale calibration coefficients of the channel selected by CH. The word length for
reading and writing these coefficients is 24 bits, regardless of the status of the WL bit of the control
register. Therefore, when writing to the calibration register, 24 bits of data must be written; otherwise the
new data will not be transferred to the calibration register.
REV. F
–9–
AD7712
PGA Gain
G2 Gl
G0
Gain
0
0
0
0
1
1
1
1
1
2
4
8
16
32
64
128
(Default Condition after the Internal Power-On Reset)
Low Level Input
High Level Input
(Default Condition after the Internal Power-On Reset)
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Channel Selection
CH Channel
0
1
AIN1
AIN2
Power-Down
PD
0
1
Normal Operation
Power-Down
(Default Condition after the Internal Power-On Reset)
Word Length
WL Output Word Length
0
1
16-Bit
24-Bit
(Default Condition after Internal Power-On Reset)
Burnout Current
BO
0
1
Off
On
(Default Condition after Internal Power-On Reset)
Bipolar/Unipolar Selection (Both Inputs)
B/U
0
1
Bipolar
Unipolar
(Default Condition after Internal Power-On Reset)
Filter Selection (FS11–FS0)
The on-chip digital filter provides a sinc3 (or (sinx/x)3) filter
response. The 12 bits of data programmed into these bits determine the filter cutoff frequency, the position of the first notch of
the filter, and the data rate for the part. In association with the
gain selection, it also determines the output noise (and therefore
the effective resolution) of the device.
The first notch of the filter occurs at a frequency determined by
the relationship filter first notch frequency = (fCLK IN/512)/code
where code is the decimal equivalent of the code in bits FS0 to
FS11 and is in the range 19 to 2,000. With the nominal fCLK IN of
10 MHz, this results in a first notch frequency range from 9.76 Hz
to 1.028 kHz. To ensure correct operation of the AD7712, the
value of the code loaded to these bits must be within this range.
Failure to do this will result in unspecified operation of the device.
Changing the filter notch frequency, as well as the selected gain,
impacts resolution. Tables I and II and Figure 2 show the effect
of the filter notch frequency and gain on the effective resolution
of the AD7712. The output data rate (or effective conversion
time) for the device is equal to the frequency selected for the
first notch of the filter. For example, if the first notch of the filter
is selected at 50 Hz, then a new word is available at a 50 Hz rate
or every 20 ms. If the first notch is at 1 kHz, a new word is available every 1 ms.
The settling time of the filter to a full-scale step input change is
worst case 4 ⫻ 1/(output data rate). This settling time is to
100% of the final value. For example, with the first filter notch
at 50 Hz, the settling time of the filter to a full-scale step input
change is 80 ms max. If the first notch is at 1 kHz, the settling
time of the filter to a full-scale input step is 4 ms max. This
settling time can be reduced to 3 ⫻ l/(output data rate) by synchronizing the step input change to a reset of the digital filter. In
other words, if the step input takes place with SYNC low, the
settling time will be 3 ⫻ l/(output data rate). If a change of
channels takes place, the settling time is 3 ⫻ l/(output data rate)
regardless of the SYNC input.
The –3 dB frequency is determined by the programmed first
notch frequency according to the relationship filter –3 dB
frequency = 0.262 ⫻ first notch frequency.
–10–
REV. F
AD7712
Tables I and II show the output rms noise for some typical
notch and –3 dB frequencies. The numbers given are for the
bipolar input ranges with a VREF of 2.5 V. These numbers are
typical and are generated with an analog input voltage of 0 V.
The output noise from the part comes from two sources. First,
there is the electrical noise in the semiconductor devices used in
the implementation of the modulator (device noise). Second,
when the analog input signal is converted into the digital domain, quantization noise is added. The device noise is at a low
level and is largely independent of frequency. The quantization
noise starts at an even lower level but rises rapidly with increasing
frequency to become the dominant noise source. Consequently,
lower filter notch settings (below 60 Hz approximately) tend to
be device noise dominated while higher notch settings are dominated by quantization noise. Changing the filter notch and cutoff
frequency in the quantization noise dominated region results in a
more dramatic improvement in noise performance than it does
in the device noise dominated region as shown in Table I.
Furthermore, quantization noise is added after the PGA, so
effective resolution is independent of gain for the higher filter
notch frequencies. Meanwhile, device noise is added in the PGA
and, therefore, effective resolution suffers a little at high gains
for lower notch frequencies.
At the lower filter notch settings (below 60 Hz), the no missing
codes performance of the device is at the 24-bit level. At the
higher settings, more codes will be missed until at the 1 kHz
notch setting; no missing codes performance is guaranteed only
to the 12-bit level. However, since the effective resolution of the
part is 10.5 bits for this filter notch setting, this no missing codes
performance should be more than adequate for all applications.
The effective resolution of the device is defined as the ratio of
the output rms noise to the input full scale. This does not
remain constant with increasing gain or with increasing bandwidth. Table II is the same as Table I except that the output is
expressed in terms of effective resolution (the magnitude of the
rms noise with respect to 2 ⴛ VREF/GAIN, i.e., the input full
scale). It is possible to do post filtering on the device to improve
the output data rate for a given –3 dB frequency and to further
reduce the output noise (see the Digital Filtering section).
Table I. Output Noise vs. Gain and First Notch Frequency
Typical Output RMS Noise (␮V)
First Notch of
Filter and O/P –3 dB
Gain of
Data Rate1
Frequency 1
Gain of
2
Gain of
4
Gain of
8
Gain of
16
Gain of
32
Gain of
64
Gain of
128
10 Hz2
25 Hz2
30 Hz2
50 Hz2
60 Hz2
100 Hz3
250 Hz3
500 Hz3
1 kHz3
0.78
1.1
1.31
2.06
2.36
6.4
75
0.26 ⫻ 103
1.6 ⫻ 103
0.48
0.63
0.84
1.2
1.33
3.7
25
140
0.7 ⫻ 103
0.33
0.5
0.57
0.64
0.87
1.8
12
70
0.29 ⫻ 103
0.25
0.44
0.46
0.54
0.63
1.1
7.5
35
180
0.25
0.41
0.43
0.46
0.62
0.9
4
25
120
0.25
0.38
0.4
0.46
0.6
0.65
2.7
15
70
0.25
0.38
0.4
0.46
0.56
0.65
1.7
8
40
2.62 Hz
6.55 Hz
7.86 Hz
13.1 Hz
15.72 Hz
26.2 Hz
65.5 Hz
131 Hz
262 Hz
1.0
1.8
2.5
4.33
5.28
13
130
0.6 ⫻ 103
3.1 ⫻ 103
NOTES
1
The default condition (after the internal power-on reset) for the first notch of filter is 60 Hz.
2
For these filter notch frequencies, the output rms noise is primarily dominated by device noise, and, as a result, is independent of the value of the reference voltage.
Therefore, increasing the reference voltage will give an increase in the effective resolution of the device (i.e., the ratio of the rms noise to the input full scale is
increased since the output rms noise remains constant as the input full scale increases).
3
For these filter notch frequencies, the output rms noise is dominated by quantization noise, and, as a result, is proportional to the value of the reference voltage.
Table II. Effective Resolution vs. Gain and First Notch Frequency
Effective Resolution* (Bits)
First Notch of
Filter and O/P –3 dB
Data Rate
Frequency
Gain of
1
Gain of
2
Gain of
4
Gain of
8
Gain of
16
Gain of
32
Gain of
64
Gain of
128
10 Hz
25 Hz
30 Hz
50 Hz
60 Hz
100 Hz
250 Hz
500 Hz
1 kHz
22.5
21.5
21
20
20
18.5
15
13
10.5
21.5
21
21
20
20
18.5
15.5
13
10.5
21.5
21
20.5
20
20
18.5
15.5
13
11
21
20
20
20
19.5
18.5
15.5
13
11
20.5
19.5
19.5
19
19
18
15.5
13
11
19.5
18.5
18.5
18.5
18
17.5
15.5
12.5
10.5
18.5
17.5
17.5
17.5
17
17
15
12.5
10
17.5
16.5
16.5
16.5
16
16
14.5
12.5
10
2.62 Hz
6.55 Hz
7.86 Hz
13.1 Hz
15.72 Hz
26.2 Hz
65.5 Hz
131 Hz
262 Hz
*Effective resolution is defined as the magnitude of the output rms noise with respect to the input full scale (i.e., 2 ⫻ VREF/GAIN). The above table applies for
a VREF of 2.5 V and resolution numbers are rounded to the nearest 0.5 LSB.
REV. F
–11–
AD7712
Figures 2a and 2b give information similar to that outlined in Table I. In these plots, the output rms noise is shown for the full range
of available cutoffs frequencies rather than for some typical cutoff frequencies as in Tables I and II. The numbers given in these plots
are typical values at 25°C.
10000
1000
GAIN OF 1
GAIN OF 2
1000
GAIN OF 16
100
GAIN OF 8
OUTPUT NOISE – ␮V
OUTPUT NOISE – ␮V
GAIN OF 4
100
10
GAIN OF 32
GAIN OF 64
GAIN OF 128
10
1
1
0.1
10
0.1
1000
100
NOTCH FREQUENCY – Hz
10
10000
1000
100
10000
NOTCH FREQUENCY – Hz
Figure 2b. Plot of Output Noise vs. Gain and
Notch Frequency (Gains of 16 to 128)
Figure 2a. Plot of Output Noise vs. Gain and
Notch Frequency (Gains of 1 to 8)
CIRCUIT DESCRIPTION
The AD7712 is a sigma-delta A/D converter with on-chip digital
filtering, intended for the measurement of wide dynamic range,
low frequency signals such as those in industrial control or process
control applications. It contains a sigma-delta (or chargebalancing) ADC, a calibration microcontroller with on-chip
static RAM, a clock oscillator, a digital filter, and a bidirectional
serial communications port.
The basic connection diagram for the part is shown in Figure 3.
This shows the AD7712 in the external clocking mode with both
the AVDD and DVDD pins of the AD7712 being driven from the
analog 5 V supply. Some applications will have separate supplies
for both AVDD and DVDD, and in some of these cases, the analog
supply will exceed the 5 V digital supply (see the Power Supplies
and Grounding section).
The part contains two analog input channels, one programmable
gain differential input, and one programmable gain high level
single-ended input. The gain range on both inputs is from 1 to
128. For the AIN1 input, this means that the input can accept
unipolar signals of between 0 mV and 20 mV and 0 mV and
+2.5 V or bipolar signals in the range from ± 20 mV to ± 2.5 V
when the reference input voltage equals 2.5 V. The input voltage range for the AIN2 input is ± 4 ⫻ VREF/GAIN and is ± 10 V
with the nominal reference of 2.5 V and a gain of 1. The input
signal to the selected analog input channel is continuously
sampled at a rate determined by the frequency of the master
clock, MCLK IN, and the selected gain (see Table III). A
chargebalancing A/D converter (sigma-delta modulator) converts
the sampled signal into a digital pulse train whose duty cycle
contains the digital information. The programmable gain
function on the analog input is also incorporated in this sigmadelta modulator with the input sampling frequency being
modified to give the higher gains. A sinc3 digital low-pass filter
processes the output of the sigma-delta modulator and updates
the output register at a rate determined by the first notch
frequency of this filter. The output data can be read from the
serial port randomly or periodically at any rate up to the output
register update rate. The first notch of this digital filter (and
therefore its –3 dB frequency) can be programmed via an on-chip
control register. The programmable range for this first notch
frequency is from 9.76 Hz to 1.028 kHz, giving a programmable
range for the –3 dB frequency of 2.58 Hz to 269 Hz.
–12–
ANALOG
5V SUPPLY
10␮F
0.1␮F
0.1␮F
AVDD
DVDD
DRDY
DIFFERENTIAL
ANALOG INPUT
SINGLE-ENDED
ANALOG INPUT
DVDD
AIN1(+)
AIN1(–)
AIN2
STANDBY
ANALOG
GROUND
AGND
DIGITAL
GROUND
DGND
VSS
REF OUT
DATA
READY
TFS
TRANSMIT
(WRITE)
RFS
RECEIVE
(READ)
AD7712
SDATA
SERIAL
DATA
SCLK
SERIAL
CLOCK
A0
ADDRESS
INPUT
MODE
SYNC
REF IN(+)
V BIAS
MCLK OUT
REF IN(–)
MCLK IN
5V
Figure 3. Basic Connection Diagram
REV. F
AD7712
The AD7712 provides a number of calibration options that can
be programmed via the on-chip control register. A calibration
cycle can be initiated at any time by writing to this control register. The part can perform self-calibration using the on-chip
calibration microcontroller and SRAM to store calibration
parameters. Other system components can also be included in
the calibration loop to remove offset and gain errors in the input
channel using the system calibration mode. Another option is a
background calibration mode where the part continuously
performs self-calibration and updates the calibration coefficients. Once the part is in this mode, the user does not have to
worry about issuing periodic calibration commands to the
device or asking the device to recalibrate when there is a change
in the ambient temperature or power supply voltage.
The AD7712 gives the user access to the on-chip calibration
registers, allowing the microprocessor to read the device’s
calibration coefficients and also to write its own calibration
coefficients to the part from prestored values in E2PROM. This
gives the microprocessor much greater control over the AD7712’s
calibration procedure. It also means that the user can verify that
the device has performed its calibration correctly by comparing
the coefficients after calibration with prestored values in
E2PROM.
The AD7712 can be operated in single-supply systems, provided
that the analog input voltage on the AIN1 input does not go
more negative than –30 mV. For larger bipolar signals on the
AIN1 input, a VSS of –5 V is required by the part. For battery
operation or low power systems, the AD7712 offers a standby
mode (controlled by the STANDBY pin) that reduces idle
power consumption to typically 100 µW.
Oversampling is fundamental to the operation of sigma-delta
ADCs. Using the quantization noise formula for an ADC:
SNR = (6.02 3 number of bits + 1.76) dB
A 1-bit ADC or comparator yields an SNR of 7.78 dB.
The AD7712 samples the input signal at a frequency of 39 kHz
or greater (see Table III). As a result, the quantization noise is
spread over a much wider frequency than that of the band of
interest. The noise in the band of interest is reduced still further
by analog filtering in the modulator loop, which shapes the
quantization noise spectrum to move most of the noise energy
to frequencies outside the bandwidth of interest. The noise
performance is thus improved from this 1-bit level to the performance outlined in Tables I and II and in Figure 2.
The output of the comparator provides the digital input for the
1-bit DAC, so that the system functions as a negative feedback
loop that tries to minimize the difference signal. The digital data
that represents the analog input voltage is contained in the duty
cycle of the pulse train appearing at the output of the comparator. It can be retrieved as a parallel binary data-word using a
digital filter.
Sigma-delta ADCs are generally described by the order of the
analog low-pass filter. A simple example of a first-order sigmadelta ADC is shown in Figure 5. This contains only a first order
low-pass filter or integrator. It also illustrates the derivation of
the alternative name for these devices: charge-balancing ADCs.
DIFFERENTIAL
AMPLIFIER
COMPARATOR
VIN
THEORY OF OPERATION
The general block diagram of a sigma-delta ADC is shown in
Figure 4. It contains the following elements:
•
•
•
•
•
•
+FS
DAC
A sample-hold amplifier
–FS
A differential amplifier or subtracter
Figure 5. Basic Charge-Balancing ADC
An analog low-pass filter
It consists of a differential amplifier (whose output is the difference between the analog input and the output of a 1-bit DAC),
an integrator, and a comparator. The term charge balancing,
comes from the fact that this system is a negative feedback loop
that tries to keep the net charge on the integrator capacitor at
zero by balancing charge injected by the input voltage with
charge injected by the 1-bit DAC. When the analog input is
zero, the only contribution to the integrator output comes from
the 1-bit DAC. For the net charge on the integrator capacitor to
be zero, the DAC output must spend half its time at +FS and
half its time at –FS. Assuming ideal components, the duty cycle
of the comparator will be 50%.
A 1-bit A/D converter (comparator)
A 1-bit DAC
A digital low-pass filter
S/H AMP
COMPARATOR
ANALOG
LOW-PASS
FILTER
DAC
DIGITAL
FILTER
DIGITAL DATA
Figure 4. General Sigma-Delta ADC
In operation, the analog signal sample is fed to the subtracter,
along with the output of the 1-bit DAC. The filtered difference
signal is fed to the comparator, whose output samples the difference signal at a frequency many times that of the analog signal
sampling frequency (oversampling).
REV. F
When a positive analog input is applied, the output of the 1-bit
DAC must spend a larger proportion of the time at +FS, so the
duty cycle of the comparator increases. When a negative input
voltage is applied, the duty cycle decreases.
The AD7712 uses a second-order sigma-delta modulator and a
digital filter that provides a rolling average of the sampled output. After power-up, or if there is a step change in the input
voltage, there is a settling time that must elapse before valid
data is obtained.
–13–
AD7712
Input Sample Rate
0
The modulator sample frequency for the device remains at
fCLK IN/512 (19.5 kHz @ fCLK IN = 10 MHz) regardless of the
selected gain. However, gains greater than ⫻1 are achieved by
a combination of multiple input samples per modulator cycle
and scaling the ratio of reference capacitor to input capacitor.
As a result of the multiple sampling, the input sample rate of
the device varies with the selected gain (see Table III). The
effective input impedance is 1/C ⫻ fS where C is the input
sampling capacitance and fS is the input sample rate.
–20
–40
–60
GAIN – dB
–80
–100
–120
–140
–160
–180
–200
Table III. Input Sampling Frequency vs. Gain
–220
Gain
Input Sampling Frequency (fS)
1
2
4
8
16
32
64
128
fCLK IN/256 (39 kHz @ fCLK IN = 10 MHz)
2 ⫻ fCLK IN/256 (78 kHz @ fCLK IN = 10 MHz)
4 ⫻ fCLK IN/256 (156 kHz @ fCLK IN = 10 MHz)
8 ⫻ fCLK IN/256 (312 kHz @ fCLK IN = 10 MHz)
8 ⫻ fCLK IN/256 (312 kHz @ fCLK IN = 10 MHz)
8 ⫻ fCLK IN/256 (312 kHz @ fCLK IN = 10 MHz)
8 ⫻ fCLK IN/256 (312 kHz @ fCLK IN = 10 MHz)
8 ⫻ fCLK IN/256 (312 kHz @ fCLK IN = 10 MHz)
DIGITAL FILTERING
The AD7712’s digital filter behaves like a similar analog filter,
with a few minor differences.
First, since digital filtering occurs after the A-to-D conversion
process, it can remove noise injected during the conversion
process. Analog filtering cannot do this.
On the other hand, analog filtering can remove noise superimposed on the analog signal before it reaches the ADC. Digital
filtering cannot do this, and noise peaks riding on signals near
full scale have the potential to saturate the analog modulator
and digital filter, even though the average value of the signal
is within limits. To alleviate this problem, the AD7712 has
overrange headroom built into the sigma-delta modulator and
digital filter, which allows overrange excursions of 5% above
the analog input range. If noise signals are larger than this,
consideration should be given to analog input filtering, or to
reducing the input channel voltage so that its full scale is half
that of the analog input channel full scale. This will provide
an overrange capability greater than 100% at the expense of
reducing the dynamic range by 1 bit (50%).
Filter Characteristics
The cutoff frequency of the digital filter is determined by the
value loaded to bits FS0 to FS11 in the control register. At
the maximum clock frequency of 10 MHz, the minimum
cutoff frequency of the filter is 2.58 Hz while the maximum
programmable cutoff frequency is 269 Hz.
Figure 6 shows the filter frequency response for a cutoff
frequency of 2.62 Hz, which corresponds to a first filter notch
frequency of 10 Hz. This is a (sinx/x)3 response (also called
sinc3), that provides >100 dB of 50 Hz and 60 Hz rejection.
Programming a different cutoff frequency via FS0–FS11 does
not alter the profile of the filter response; it changes the frequency of the notches as outlined in the Control Register
section.
–240
0
10
20
30
40
FREQUENCY – Hz
50
60
Figure 6. Frequency Response of AD7712 Filter
Since the AD7712 contains this on-chip, low-pass filtering,
there is a settling time associated with step function inputs, and
data on the output will be invalid after a step change until the
settling time has elapsed. The settling time depends upon the
notch frequency chosen for the filter. The output data rate
equates to this filter notch frequency, and the settling time of
the filter to a full-scale step input is four times the output data
period. In applications using both input channels, the settling
time of the filter must be allowed to elapse before data from the
second channel is accessed.
Post Filtering
The on-chip modulator provides samples at a 19.5 kHz output
rate. The on-chip digital filter decimates these samples to provide data at an output rate that corresponds to the programmed
first notch frequency of the filter. Since the output data rate
exceeds the Nyquist criterion, the output rate for a given bandwidth will satisfy most application requirements. However, there
may be some applications that require a higher data rate for a
given bandwidth and noise performance. Applications that need
this higher data rate will require some post filtering following
the digital filter of the AD7712.
For example, if the required bandwidth is 7.86 Hz but the
required update rate is 100 Hz, the data can be taken from the
AD7712 at the 100 Hz rate giving a –3 dB bandwidth of
26.2 Hz. Post filtering can be applied to this to reduce the
bandwidth and output noise, to the 7.86 Hz bandwidth level,
while maintaining an output rate of 100 Hz.
Post filtering can also be used to reduce the output noise from
the device for bandwidths below 2.62 Hz. At a gain of 128, the
output rms noise is 250 nV. This is essentially device noise or
white noise, and since the input is chopped, the noise has a flat
frequency response. By reducing the bandwidth below 2.62 Hz,
the noise in the resultant passband can be reduced. A reduction
in bandwidth by a factor of 2 results in a √2 reduction in the
output rms noise. This additional filtering will result in a longer
settling time.
–14–
REV. F
AD7712
Antialias Considerations
The digital filter does not provide any rejection at integer multiples of the modulator sample frequency (n ⫻ 19.5 kHz, where
n = 1, 2, 3 . . . ). This means that there are frequency bands,
± f3 dB wide (f3 dB is cutoff frequency selected by FS0 to FS11),
where noise passes unattenuated to the output. However, due to
the AD7712’s high oversampling ratio, these bands occupy only
a small fraction of the spectrum, and most broadband noise is
filtered. In any case, because of the high oversampling ratio, a
simple, RC, single-pole filter is generally sufficient to attenuate
the signals in these bands on the analog input and thus provide
adequate antialiasing filtering.
If passive components are placed in front of the AIN1 input of the
AD7712, care must be taken to ensure that the source impedance
is low enough so as not to introduce gain errors in the system. The
dc input impedance for the AIN1 input is over 1 GΩ. The input
appears as a dynamic load that varies with the clock frequency
and with the selected gain (see Figure 7). The input sample
rate, as shown in Table III, determines the time allowed for the
analog input capacitor, CIN, to be charged. External impedances
result in a longer charge time for this capacitor, which may result
in gain errors being introduced on the analog inputs. Table IV
shows the allowable external resistance/capacitance values
such that no gain error to the 16-bit level is introduced, while
Table V shows the allowable external resistance/capacitance
values such that no gain error to the 20-bit level is introduced.
Both inputs of the differential input channels (AIN1) look into
similar input circuitry.
RINT
(7k⍀ TYP)
AIN
CINT
HIGH
IMPEDANCE
>1G⍀
Table IV. Typical External Series Resistance That Will Not
Introduce 16-Bit Gain Error
Gain
0
External Capacitance (pF)
50
100
500
1000
1
2
4
8–128
184 kΩ
88.6 kΩ
41.4 kΩ
17.6 kΩ
45.3 kΩ
22.1 kΩ
10.6 kΩ
4.8 kΩ
27.1 kΩ
13.2 kΩ
6.3 kΩ
2.9 kΩ
7.3 kΩ
3.6 kΩ
1.7 kΩ
790 Ω
4.1 kΩ
2.0 kΩ
970 Ω
440 Ω
1.1 kΩ
560 Ω
270 Ω
120 Ω
Table V. Typical External Series Resistance That Will Not
Introduce 20-Bit Gain Error
Gain
0
External Capacitance (pF)
50
100
500
1000
5000
1
2
4
8–128
145 kΩ
70.5 kΩ
31.8 kΩ
13.4 kΩ
34.5 kΩ
16.9 kΩ
8.0 kΩ
3.6 kΩ
700 Ω
350 Ω
170 Ω
80 Ω
20.4 kΩ
10 kΩ
4.8 kΩ
2.2 kΩ
5.2 kΩ
2.5 kΩ
1.2 kΩ
550 Ω
2.8 kΩ
1.4 kΩ
670 Ω
300 Ω
The numbers in Tables IV and V assume a full-scale change on
the analog input. In any case, the error introduced due to longer
charging times is a gain error that can be removed using the
system calibration capabilities of the AD7712 provided that the
resultant span is within the span limits of the system calibration
techniques for the AD7712.
The AIN2 input contains a resistive attenuation network as
outlined in Figure 8. The typical input impedance on this input
is 44 kΩ. As a result, the AIN2 input should be driven from a
low impedance source.
(11.5pF TYP)
VBIAS
AIN2
33k⍀
11k⍀
SWITCHING FREQUENCY DEPENDS ON
fCLKIN AND SELECTED GAIN
MODULATOR
CIRCUIT
VBIAS
Figure 7. AIN1 Input Impedance
Figure 8. AIN2 Input Impedance
REV. F
5000
–15–
AD7712
ANALOG INPUT FUNCTIONS
Analog Input Ranges
The analog inputs on the AD7712 provide the user with considerable flexibility in terms of analog input voltage ranges. One of
the inputs is a differential, programmable gain, input channel
that can handle either unipolar or bipolar input signals. The
common-mode range of this input is from VSS to AVDD provided
that the absolute value of the analog input voltage lies between
VSS – 30 mV and AVDD + 30 mV. The second analog input is a
single-ended, programmable gain, high level input that accepts
analog input ranges of 0 to +4 ⫻ VREF/GAIN or ±4 ⫻ VREF/GAIN.
The dc input leakage current on the AIN1 input is 10 pA maximum at 25°C (± 1 nA over temperature). This results in a dc
offset voltage developed across the source impedance. However,
this dc offset effect can be compensated for by a combination of
the differential input capability of the part and its system calibration mode. The dc input current on the AIN2 input depends
on the input voltage. For the nominal input voltage range of
± 10 V, the input current is ± 225 µA typ.
Burnout Current
The AIN1(+) input of the AD7712 contains a 4.5 µA current
source that can be turned on/off via the control register. This
current source can be used in checking that a transducer has not
burned out or gone open circuit before attempting to take measurements on that channel. If the current is turned on and is
allowed to flow into the transducer and a measurement of the
input voltage on the AIN1 input is taken, it can indicate that the
transducer is not functioning correctly. For normal operation,
this burnout current is turned off by writing a 0 to the BO bit in
the control register.
Bipolar/Unipolar Inputs
The two analog inputs on the AD7712 can accept either unipolar or bipolar input voltage ranges. Bipolar or unipolar options
are chosen by programming the B/U bit of the control register.
This programs both channels for either unipolar or bipolar
operation. Programming the part for either unipolar or bipolar
operation does not change any of the input signal conditioning;
it simply changes the data output coding. The data coding is
binary for unipolar inputs and offset binary for bipolar inputs.
The AIN1 input channel is differential and, as a result, the
voltage to which the unipolar and bipolar signals are referenced
is the voltage on the AIN1(–) input. For example, if AIN1(–) is
1.25 V and the AD7712 is configured for unipolar operation
with a gain of 1 and a VREF of 2.5 V, the input voltage range on
the AIN1(+) input is 1.25 V to 3.75 V. If AIN1(–) is 1.25 V and
the AD7712 is configured for bipolar mode with a gain of 1 and
a VREF of 2.5 V, the analog input range on the AIN1(+) input is
–1.25 V to +3.75 V. For the AIN2 input, the input signals are
referenced to AGND.
to 1 mA to an external load. In applications where REF OUT
is connected directly to REF IN(+), REF IN(–) should be tied
to AGND to provide the nominal 2.5 V reference for the
AD7712.
The reference inputs of the AD7712, REF IN(+) and
REF IN(–), provide a differential reference input capability.
The common-mode range for these differential inputs is from
VSS to AVDD. The nominal differential voltage, VREF (REF
IN(+) – REF IN(–)), is 2.5 V for specified operation, but the
reference voltage can go to 5 V with no degradation in performance provided that the absolute value of REF IN(+) and REF
IN(–) does not exceed its AVDD and VSS limits and the VBIAS
input voltage range limits are obeyed. The part is also functional
with VREF voltages down to 1 V but with degraded performance
as the output noise will, in terms of LSB size, be larger. REF
IN(+) must always be greater than REF IN(–) for correct operation of the AD7712.
Both reference inputs provide a high impedance, dynamic load
similar to the AIN1 analog inputs. The maximum dc input
leakage current is 10 pA (± 1 nA over temperature), and source
resistance may result in gain errors on the part. The reference
inputs look like the AIN1 analog input (see Figure 7). In this
case, RINT is 5 kΩ typ and CINT varies with gain. The input
sample rate is fCLK IN/256 and does not vary with gain. For gains
of 1 to 8, CINT is 20 pF; for a gain of 16, it is 10 pF; for a gain
of 32, it is 5 pF; for a gain of 64, it is 2.5 pF; and for a gain of
128, it is 1.25 pF.
The digital filter of the AD7712 removes noise from the reference input just as it does with the analog input, and the same
limitations apply regarding lack of noise rejection at integer
multiples of the sampling frequency. The output noise performance outlined in Tables I and II assumes a clean reference. If
the reference noise in the bandwidth of interest is excessive, it
can degrade the performance of the AD7712. Using the on-chip
reference as the reference source for the part (i.e., connecting
REF OUT to REF IN) results in somewhat degraded output
noise performance from the AD7712 for portions of the noise
table that are dominated by the device noise. The on-chip reference noise effect is eliminated in ratiometric applications where
the reference is used to provide its excitation voltage for the analog
front end. The connection scheme shown in Figure 9 between
the REF OUT and REF IN pins of the AD7712 is recommended
when using the on-chip reference. Recommended reference
voltage sources for the AD7712 include the AD780 and AD680
2.5 V references.
REFERENCE INPUT/OUTPUT
The AD7712 contains a temperature compensated 2.5 V reference, which has an initial tolerance of ± 1%. This reference
voltage is provided at the REF OUT, pin and can be used as the
reference voltage for the part by connecting the REF OUT pin
to the REF IN(+) pin. This REF OUT pin is a single-ended
output, referenced to AGND, which is capable of providing up
–16–
REF OUT
AD7712
REF IN(+)
REF IN(–)
Figure 9. REF OUT/REF IN Connection
REV. F
AD7712
The current drawn from the DVDD power supply is also directly
related to fCLK IN. Reducing fCLK IN by a factor of 2 will halve the
DVDD current but will not affect the current drawn from the
AVDD power supply.
VBIAS Input
The VBIAS input determines at what voltage the internal analog
circuitry is biased. It essentially provides the return path for
analog currents flowing in the modulator, and as such it should
be driven from a low impedance point to minimize errors.
System Synchronization
For maximum internal headroom, the VBIAS voltage should be
set halfway between AVDD and VSS. The difference between
AVDD and (VBIAS + 0.85 ⫻ VREF) determines the amount of
headroom the circuit has at the upper end, while the difference
between VSS and (VBIAS – 0.85 ⫻ VREF) determines the amount
of headroom the circuit has at the lower end. Care should be
taken in choosing a VBIAS voltage to ensure that it stays within
prescribed limits. For single +5 V operation, the selected VBIAS
voltage must ensure that VBIAS ± 0.85 ⫻ VREF does not exceed
AVDD or VSS or that the VBIAS voltage itself is greater than
VSS + 2.1 V and less than AVDD – 2.1 V. For single +10 V
operation or dual ± 5 V operation, the selected VBIAS voltage
must ensure that VBIAS ± 0.85 ⫻ VREF does not exceed AVDD
or VSS or that the VBIAS voltage itself is greater than VSS + 3 V
or less than AVDD – 3 V. For example, with AVDD = +4.75 V,
VSS = 0 V and VREF = +2.5 V, the allowable range for the VBIAS
voltage is +2.125 V to +2.625 V. With AVDD = +9.5 V, VSS = 0 V
and VREF = +5 V, the range for VBIAS is +4.25 V to +5.25 V.
With AVDD = +4.75 V, VSS = –4.75 V, and VREF = +2.5 V, the
VBIAS range is –2.625 V to +2.625 V.
The VBIAS voltage does have an effect on the AVDD power supply
rejection performance of the AD7712. If the VBIAS voltage tracks
the AVDD supply, it improves the power supply rejection from
the AVDD supply line from 80 dB to 95 dB. Using an external
Zener diode connected between the AVDD line and VBIAS as the
source for the VBIAS voltage gives the improvement in AVDD
power supply rejection performance.
USING THE AD7712
SYSTEM DESIGN CONSIDERATIONS
The AD7712 operates differently from successive approximation
ADCs or integrating ADCs. Since it samples the signal continuously, like a tracking ADC, there is no need for a start convert
command. The output register is updated at a rate determined
by the first notch of the filter, and the output can be read at any
time, either synchronously or asynchronously.
Clocking
The SYNC input can also be used to reset the digital filter in
systems where the turn-on time of the digital power supply
(DVDD) is very long. In such cases, the AD7712 will start operating internally before the DVDD line has reached its minimum
operating level, 4.75 V. With a low DVDD voltage, the AD7712’s
internal digital filter logic does not operate correctly. Thus, the
AD7712 may have clocked itself into an incorrect operating
condition by the time that DVDD has reached its correct level.
The digital filter will be reset upon issue of a calibration
command (whether it is self-calibration, system calibration, or
background calibration) to the AD7712. This ensures correct
operation of the AD7712. In systems where the power-on
default conditions of the AD7712 are acceptable, and no calibration is performed after power-on, issuing a SYNC pulse to the
AD7712 will reset the AD7712’s digital filter logic. An R, C on
the SYNC line, with R, C time constant longer than the DVDD
power-on time, will perform the SYNC function.
Accuracy
Sigma-delta ADCs, like VFCs and other integrating ADCs, do
not contain any source of nonmonotonicity and inherently offer
no missing codes performance. The AD7712 achieves excellent
linearity by the use of high quality, on-chip silicon dioxide
capacitors, which have a very low capacitance/voltage coefficient.
The device also achieves low input drift through the use of chopper stabilized techniques in its input stage. To ensure excellent
performance over time and temperature, the AD7712 uses digital
calibration techniques that minimize offset and gain error.
Autocalibration
Autocalibration on the AD7712 removes offset and gain errors
from the device. A calibration routine should be initiated on the
device whenever there is a change in the ambient operating
temperature or supply voltage. It should also be initiated if there
is a change in the selected gain, filter notch, or bipolar/unipolar
input range. However, if the AD7712 is in its background calibration mode, the above changes are all automatically taken
care of (after the settling time of the filter has been allowed for).
The AD7712 requires a master clock input, which may be an
external TTL/CMOS compatible clock signal applied to the
MCLK IN pin with the MCLK OUT pin left unconnected.
Alternatively, a crystal of the correct frequency can be connected
between MCLK IN and MCLK OUT, in which case the clock
circuit will function as a crystal controlled oscillator. For lower
clock frequencies, a ceramic resonator may be used instead of
the crystal. For these lower frequency oscillators, external
capacitors may be required on either the ceramic resonator or
on the crystal.
The input sampling frequency, the modulator sampling frequency,
the –3 dB frequency, the output update rate, and the calibration
time are all directly related to the master clock frequency, fCLK
IN. Reducing the master clock frequency by a factor of 2 will
halve the above frequencies and update rate and will double
the calibration time.
REV. F
If multiple AD7712s are operated from a common master clock,
they can be synchronized to update their output registers simultaneously. A falling edge on the SYNC input resets the filter
and places the AD7712 into a consistent, known state. A common signal to the AD7712’s SYNC inputs will synchronize their
operation. This would normally be done after each AD7712 has
performed its own calibration or has had calibration coefficients
loaded to it.
The AD7712 offers self-calibration, system calibration, and
background calibration facilities. For calibration to occur on the
selected channel, the on-chip microcontroller must record the
modulator output for two different input conditions. These are
zero-scale and full-scale points. With these readings, the microcontroller can calculate the gain slope for the input to output
transfer function of the converter. Internally, the part works
with a resolution of 33 bits to determine its conversion result of
either 16 bits or 24 bits.
–17–
AD7712
The AD7712 also provides the facility to write to the on-chip
calibration registers, and, in this manner, the span and offset for
the part can be adjusted by the user. The offset calibration register contains a value that is subtracted from all conversion
results, while the full-scale calibration register contains a value
that is multiplied by all conversion results. The offset calibration
coefficient is subtracted from the result prior to the multiplication
by the full-scale coefficient. In the first three modes outlined
here, the DRDY line indicates that calibration is complete by
going low. If DRDY is low before (or goes low during) the
calibration command, it may take up to one modulator cycle
before DRDY goes high to indicate that calibration is in progress.
Therefore, the DRDY line should be ignored for up to one
modulator cycle after the last bit of the calibration command is
written to the control register.
Self-Calibration
In the self-calibration mode with a unipolar input range, the
zero-scale point used in determining the calibration coefficients
is with both inputs shorted (i.e., AIN1(+) = AIN1(–) = VBIAS
for AIN1 and AIN2 = VBIAS for AIN2 ) and the full-scale point
is VREF. The zero-scale coefficient is determined by converting
an internal shorted inputs node. The full-scale coefficient is
determined from the span between this shorted inputs conversion
and a conversion on an internal VREF node. The self-calibration mode is invoked by writing the appropriate values (0, 0, 1)
to the MD2, MD1, and MD0 bits of the control register. In this
calibration mode, the shorted inputs node is switched in to the
modulator first and a conversion is performed; the VREF node is
then switched in, and another conversion is performed. When
the calibration sequence is complete, the calibration coefficients
updated and the filter resettled to the analog input voltage, the
DRDY output goes low. The self-calibration procedure takes
into account the selected gain on the PGA.
For bipolar input ranges in the self-calibrating mode, the
sequence is very similar to that just outlined. In this case, the
two points that the AD7712 calibrates are midscale (bipolar
zero) and positive full scale.
System Calibration
System calibration allows the AD7712 to compensate for system
gain and offset errors as well as its own internal errors. System
calibration performs the same slope factor calculations as selfcalibration but uses voltage values presented by the system to
the AIN inputs for the zero-scale and full-scale points. System
calibration is a two-step process. The zero-scale point must be
presented to the converter first. It must be applied to the converter before the calibration step is initiated and remain stable
until the step is complete. System calibration is initiated by
writing the appropriate values (0, 1, 0) to the MD2, MD1, and
MD0 bits of the control register. The DRDY output from the
device will signal when the step is complete by going low. After
the zero-scale point is calibrated, the full-scale point is applied
and the second step of the calibration process is initiated by
again writing the appropriate values (0, 1, 1) to MD2, MD1,
and MD0. Again the full-scale voltage must be set up before the
calibration is initiated, and it must remain stable throughout the
calibration step. DRDY goes low at the end of this second step
to indicate that the system calibration is complete. In the
unipolar mode, the system calibration is performed between the
two endpoints of the transfer function; in the bipolar mode, it is
performed between midscale and positive full scale.
This two-step system calibration mode offers another feature.
After the sequence has been completed, additional offset or gain
calibrations can be performed by themselves to adjust the zero
reference point or the system gain. This is achieved by performing the first step of the system calibration sequence (by writing
0, 1, 0 to MD2, MD1, MD0). This will adjust the zero-scale or
offset point but will not change the slope factor from what was
set during a full system calibration sequence.
System calibration can also be used to remove any errors from
an antialiasing filter on the analog input. A simple R, C antialiasing filter on the front end may introduce a gain error on the
analog input voltage but the system calibration can be used to
remove this error.
System Offset Calibration
System offset calibration is a variation of both the system calibration and self-calibration. In this case, the zero-scale point
for the system is presented to the AIN input of the converter.
System offset calibration is initiated by writing 1, 0, 0 to MD2,
MD1, MD0. The system zero-scale coefficient is determined by
converting the voltage applied to the AIN input, while the fullscale coefficient is determined from the span between this AIN
conversion and a conversion on VREF. The zero-scale point
should be applied to the AIN input for the duration of the calibration sequence. This is a one-step calibration sequence with
DRDY going low when the sequence is completed. In the unipolar mode, the system offset calibration is performed between
the two endpoints of the transfer function; in the bipolar mode,
it is performed between midscale and positive full scale.
Background Calibration
The AD7712 also offers a background calibration mode where
the part interleaves its calibration procedure with its normal
conversion sequence. In the background calibration mode, the
same voltages used as the calibration points in the self-calibration
mode are used, i.e., shorted inputs and VREF. The background
calibration mode is invoked by writing 1, 0, 1 to MD2, MD1,
MD0 of the control register. When invoked, the background
calibration mode reduces the output data rate of the AD7712 by
a factor of 6, while the –3 dB bandwidth remains unchanged. Its
advantage is that the part is continually performing calibration
and automatically updating its calibration coefficients. As a
result, the effects of temperature drift, supply sensitivity, and
time drift on zero-scale and full-scale errors are automatically
removed. When the background calibration mode is turned on,
the part will remain in this mode until bits MD2, MD1, and
MD0 of the control register are changed. With background
calibration mode on, the first result from the AD7712 will be
incorrect as the full-scale calibration will not have been performed. For a step change on the input, the second output
update will have settled to 100% of the final value.
Table VI summarizes the calibration modes and the calibration
points associated with them. It also gives the duration from
when the calibration is invoked to when valid data is available to
the user.
–18–
REV. F
AD7712
Table VI. Calibration Truth Table
Cal Type
MD2, MD1, MD0
Zero-Scale Cal
Full-Scale Cal
Sequence
Duration
Self-Cal
System Cal
System Cal
System Offset Cal
Background Cal
0, 0, 1
0, 1, 0
0, 1, 1
1, 0, 0
1, 0, 1
Shorted Inputs
AIN
–
AIN
Shorted Inputs
VREF
–
AIN
VREF
VREF
One-Step
Two-Step
Two-Step
One-Step
One-Step
9 ⫻ 1/Output Rate
4 ⫻ 1/Output Rate
4 ⫻ 1/Output Rate
9 ⫻ 1/Output Rate
6 ⫻ 1/Output Rate
Measurement errors due to offset drift or gain drift can be eliminated at any time by recalibrating the converter or by operating
the part in the background calibration mode. Using the system
calibration mode can also minimize offset and gain errors in the
signal conditioning circuitry. Integral and differential linearity
errors are not significantly affected by temperature changes.
Span and Offset Limits
Whenever a system calibration mode is used, there are limits on
the amount of offset and span that can be accommodated. The
range of input span in both the unipolar and bipolar modes for
AIN1 has a minimum value of 0.8 ⫻ VREF/GAIN and a maximum value of 2.1 ⫻ VREF/GAIN. For AIN2, both numbers are
a factor of 4 higher.
The amount of offset that can be accommodated depends on
whether the unipolar or bipolar mode is being used. This offset
range is limited by the requirement that the positive full-scale
calibration limit is ≤ 1.05 ⫻ VREF/GAIN for AIN1. Therefore,
the offset range plus the span range cannot exceed 1.05 ⫻ VREF/
GAIN for AIN1. If the span is at its minimum (0.8 ⫻ VREF/
GAIN), the maximum the offset can be is (0.25 ⫻ VREF/GAIN)
for AIN1. For AIN2, both ranges are multiplied by a factor of 4.
In the bipolar mode, the system offset calibration range is again
restricted by the span range. The span range of the converter in
bipolar mode is equidistant around the voltage used for the
zero-scale point, thus the offset range plus half the span range
cannot exceed (1.05 × VREF/GAIN) for AIN1. If the span is
set to 2 × VREF/GAIN, the offset span cannot move more than
± (0.05 × VREF/GAIN) before the endpoints of the transfer function exceed the input overrange limits ± (1.05 × VREF/GAIN) for
AIN1. If the span range is set to the minimum ± (0.4 × VREF/
GAIN), the maximum allowable offset range is ± (0.65 × VREF/
POWER SUPPLIES AND GROUNDING
Since the analog inputs and reference input are differential,
most of the voltages in the analog modulator are common-mode
voltages. VBIAS provides the return path for most of the analog
currents flowing in the analog modulator. As a result, the VBIAS
input should be driven from a low impedance to minimize
errors due to charging/discharging impedances on this line.
When the internal reference is used as the reference source for
the part, AGND is the ground return for this reference voltage.
The analog and digital supplies to the AD7712 are independent
and separately pinned out to minimize coupling between the
analog and digital sections of the device. The digital filter will
provide rejection of broadband noise on the power supplies,
except at integer multiples of the modulator sampling frequency.
The digital supply (DVDD) must not exceed the analog positive
supply (AVDD) by more than 0.3 V in normal operation. If separate analog and digital supplies are used, the decoupling scheme
shown in Figure 10 is recommended. In systems where AVDD =
5 V and DVDD = 5 V, it is recommended that AVDD and DVDD
are driven from the same 5 V supply, although each supply
should be decoupled separately as shown in Figure 10. It is
preferable that the common supply is the system’s analog
5 V supply.
GAIN) for AIN1. Once again, for AIN2, both ranges are
multiplied by a factor of 4.
POWER-UP AND CALIBRATION
On power-up, the AD7712 performs an internal reset, which
sets the contents of the control register to a known state. However, to ensure correct calibration for the device, a calibration
routine should be performed after power-up.
It is also important that power is applied to the AD7712 before
signals at REF IN, AIN, or the logic input pins in order to avoid
excessive current. If separate supplies are used for the AD7712
and the system digital circuitry, then the AD7712 should be
powered up first. If it is not possible to guarantee this, then
current limiting resistors should be placed in series with the
logic inputs.
The power dissipation and temperature drift of the AD7712 are
low and no warm-up time is required before the initial calibration is performed. However, if an external reference is being
used, this reference must have stabilized before calibration is
initiated.
DIGITAL 5V
SUPPLY
ANALOG
SUPPLY
Drift Considerations
The AD7712 uses chopper stabilization techniques to minimize
input offset drift. Charge injection in the analog switches and dc
leakage currents at the sampling node are the primary sources of
offset voltage drift in the converter. The dc input leakage current is essentially independent of the selected gain. Gain drift
within the converter depends primarily upon the temperature
tracking of the internal capacitors. It is not affected by leakage
currents.
10␮F
0.1␮F
0.1␮F
AVDD
DVDD
AD7712
Figure 10. Recommended Decoupling Scheme
REV. F
–19–
AD7712
DIGITAL INTERFACE
The AD7712’s serial communications port provides a flexible
arrangement to allow easy interfacing to industry-standard
microprocessors, microcontrollers, and digital signal processors.
A serial read to the AD7712 can access data from the output
register, the control register, or the calibration registers. A serial
write to the AD7712 can write data to the control register or the
calibration registers.
Two different modes of operation are available, optimized for
different types of interfaces where the AD7712 can act either as
master in the system (it provides the serial clock) or as slave (an
external serial clock can be provided to the AD7712). These
two modes, labeled self-clocking mode and external clocking
mode, are discussed in detail in the following sections.
the output data register. It is reset high when the last bit of data
(either 16th bit or 24th bit) is read from the output register. If
data is not read from the output register, the DRDY line will
remain low. The output register will continue to be updated at
the output update rate, but DRDY will not indicate this. A read
from the device in this circumstance will access the most recent
word in the output register. If a new data-word becomes available to the output register while data is being read from the
output register, DRDY will not indicate this and the new dataword will be lost to the user. DRDY is not affected by reading
from the control register or the calibration registers.
Data can be accessed from the output data register only when
DRDY is low. If RFS goes low with DRDY high, no data transfer will take place. DRDY does not have any effect on reading
data from the control register or from the calibration registers.
Self-Clocking Mode
Figure 11 shows a timing diagram for reading from the AD7712
in the self-clocking mode. This read operation shows a read
from the AD7712’s output data register. A read from the control register or calibration registers is similar, but, in these cases,
the DRDY line is not related to the read function. Depending
on the output update rate, it can go low at any stage in the
control/calibration register read cycle without affecting the read
and its status should be ignored. A read operation from either
the control or calibration registers must always read 24 bits of
data from the respective register.
The AD7712 is configured for its self-clocking mode by tying
the MODE pin high. In this mode, the AD7712 provides the
serial clock signal used for the transfer of data to and from the
AD7712. This self-clocking mode can be used with processors
that allow an external device to clock their serial port, including
most digital signal processors and microcontrollers such as the
68HC11 and 68HC05. It also allows easy interfacing to serial
parallel conversion circuits in systems with parallel data communication, allowing interfacing to 74XX299 universal shift
registers without any additional decoding. In the case of shift
registers, the serial clock line should have a pull-down resistor
instead of the pull-up resistor shown in Figures 11 and 12.
Read Operation
Data can be read from the output register, the control register, or
the calibration registers. A0 determines whether the data read
accesses data from the control register or from the output/calibration registers. This A0 signal must remain valid for the duration
of the serial read operation. With A0 high, data is accessed from
either the output register or from the calibration registers. With
A0 low, data is accessed from the control register.
The function of the DRDY line is dependent on only the output
update rate of the device and the reading of the output data
register. DRDY goes low when a new data-word is available in
Figure 11 shows a read operation from the AD7712. For the
timing diagram shown, it is assumed that there is a pull-up
resistor on the SCLK output. With DRDY low, the RFS input
is brought low. RFS going low enables the serial clock of the
AD7712 and also places the MSB of the word on the serial data
line. All subsequent data bits are clocked out on a high to low
transition of the serial clock and are valid prior to the following
rising edge of this clock. The final active falling edge of SCLK
clocks out the LSB, and this LSB is valid prior to the final active
rising edge of SCLK. Coincident with the next falling edge of
SCLK, DRDY is reset high. DRDY going high turns off the
SCLK and the SDATA outputs, which means that the data
hold time for the LSB is slightly shorter than for all other bits.
DRDY (O)
t3
t2
A0 (I)
t5
t4
RFS (I)
t9
t6
SCLK (O)
t7
SDATA (O)
t8
t 10
MSB
LSB
THREE-STATE
Figure 11. Self-Clocking Mode, Output Data Read Operation
–20–
REV. F
AD7712
register or from the calibration registers. With A0 low, data is
accessed from the control register.
Write Operation
Data can be written to either the control register or calibration
registers. In either case, the write operation is not affected by
the DRDY line, and the write operation does not have any
effect on the status of DRDY. A write operation to the control
register or the calibration register must always write 24 bits to
the respective register.
The function of the DRDY line is dependent on only the output
update rate of the device and the reading of the output data
register. DRDY goes low when a new data-word is available in
the output data register. It is reset high when the last bit of data
(either 16th bit or 24th bit) is read from the output register. If
data is not read from the output register, the DRDY line will
remain low. The output register will continue to be updated at
the output update rate, but DRDY will not indicate this. A read
from the device in this circumstance will access the most recent
word in the output register. If a new data-word becomes available to the output register while data is being read from the
output register, DRDY will not indicate this, and the new dataword will be lost to the user. DRDY is not affected by reading
from the control register or the calibration register.
Figure 12 shows a write operation to the AD7712. A0 determines whether a write operation transfers data to the control
register or to the calibration registers. This A0 signal must remain
valid for the duration of the serial write operation. The falling
edge of TFS enables the internally generated SCLK output.
The serial data to be loaded to the AD7712 must be valid on
the rising edge of this SCLK signal. Data is clocked into the
AD7712 on the rising edge of the SCLK signal, with the MSB
transferred first. On the last active high time of SCLK, the LSB
is loaded to the AD7712. Subsequent to the next falling edge of
SCLK, the SCLK output is turned off. (The timing diagram of
Figure 12 assumes a pull-up resistor on the SCLK line.)
Data can be accessed from the output data register only when
DRDY is low. If RFS goes low while DRDY is high, no data
transfer will take place. DRDY does not have any effect on
reading data from the control register or from the calibration
registers.
External Clocking Mode
The AD7712 is configured for its external clocking mode by
tying the MODE pin low. In this mode, SCLK of the AD7712
is configured as an input, and an external serial clock must be
provided to this SCLK pin. This external clocking mode is
designed for direct interface to systems that provide a serial
clock output that is synchronized to the serial data output,
including microcontrollers such as the 80C51, 87C51, 68HC11,
and 68HC05 and most digital signal processors.
Read Operation
As with the self-clocking mode, data can be read from either the
output register, the control register, or the calibration registers.
A0 determines whether the data read accesses data from the
control register or from the output/calibration registers. This A0
signal must remain valid for the duration of the serial read
operation. With A0 high, data is accessed from either the output
Figures 13a and 13b show timing diagrams for reading from the
AD7712 in the external clocking mode. Figure 13a shows a
situation where all the data is read from the AD7712 in one
read operation. Figure 13b shows a situation where the data is
read from the AD7712 over a number of read operations. Both
read operations show a read from the AD7712’s output data
register. Reads from the control register and calibration registers
are similar, but, in these cases, the DRDY line is not related to
the read function. Depending on the output update rate, it can
go low at any stage in the control/calibration register read cycle
without affecting the read, and its status should be ignored. A
read operation from either the control or calibration registers
must always read 24 bits of data from the respective register.
A0 (I)
t 15
t 14
TFS (I)
t 17
t 16
t9
SCLK (O)
t 10
t 18
t 19
SDATA (O)
MSB
LSB
Figure 12. Self-Clocking Mode, Control/Calibration Register Write Operation
REV. F
–21–
AD7712
Figure 13a shows a read operation from the AD7712 where
RFS remains low for the duration of the data word transmission. With DRDY low, the RFS input is brought low. The input
SCLK signal should be low between read and write operations.
RFS going low places the MSB of the word to be read on the
serial data line. All subsequent data bits are clocked out on a
high to low transition of the serial clock and are valid prior to
the following rising edge of this clock. The penultimate falling
edge of SCLK clocks out the LSB and the final falling edge
resets the DRDY line high. This rising edge of DRDY turns off
the serial data output.
Figure 13a, but Figure 13b has a number of additional times to
show timing relationships when RFS returns high in the middle
of transferring a word.
RFS should return high during a low time of SCLK. On the
rising edge of RFS, the SDATA output is turned off. DRDY
remains low and will remain low until all bits of the data-word
are read from the AD7712, regardless of the number of times
RFS changes state during the read operation. Depending on the
time between the falling edge of SCLK and the rising edge of
RFS, the next bit (BIT N + 1) may appear on the data bus
before RFS goes high. When RFS returns low again, it activates
the SDATA output. When the entire word is transmitted, the
DRDY line will go high, turning off the SDATA output as per
Figure 13a.
Figure 13b shows a timing diagram for a read operation where
RFS returns high during the transmission of the word and
returns low again to access the rest of the data-word. Timing
parameters and functions are very similar to that outlined for
DRDY (O)
t 21
t 20
A0 (I)
t 23
t 22
RFS (I)
t 26
t 28
SCLK (I)
t 24
SDATA (O)
t 27
t 25
MSB
t 29
LSB
THREE-STATE
Figure 13a. External Clocking Mode, Output Data Read Operation
DRDY (O)
t 20
A0 (I)
t 22
RFS (I)
t 26
t 30
SCLK (I)
t 24
t 27
t 31
t 25
SDATA (O)
MSB
BIT N
THREE-STATE
t 24
t 25
BIT N+1
Figure 13b. External Clocking Mode, Output Data Read Operation (RFS Returns High during Read Operation)
–22–
REV. F
AD7712
SCLK signal with the MSB transferred first. On the last active
high time of SCLK, the LSB is loaded to the AD7712.
Write Operation
Data can be written to either the control register or calibration
registers. In either case, the write operation is not affected by
the DRDY line, and the write operation does not have any
effect on the status of DRDY. A write operation to the control
register or the calibration register must always write 24 bits to
the respective register.
Figure 14b shows a timing diagram for a write operation to the
AD7712 with TFS returning high during the write operation
and returning low again to write the rest of the data word. Timing parameters and functions are very similar to that outlined
for Figure 14a, but Figure 14b has a number of additional times
to show timing relationships when TFS returns high in the
middle of transferring a word.
Figure 14a shows a write operation to the AD7712 with TFS
remaining low for the duration of the write operation. A0 determines whether a write operation transfers data to the control
register or to the calibration registers. This A0 signal must
remain valid for the duration of the serial write operation. As
before, the serial clock line should be low between read and
write operations. The serial data to be loaded to the AD7712
must be valid on the high level of the externally applied SCLK
signal. Data is clocked into the AD7712 on the high level of this
Data to be loaded to the AD7712 must be valid prior to the
rising edge of the SCLK signal. TFS should return high during
the low time of SCLK. After TFS returns low again, the next bit
of the data-word to be loaded to the AD7712 is clocked in on
next high level of the SCLK input. On the last active high time
of the SCLK input, the LSB is loaded to the AD7712.
A0 (I)
t 32
t 33
TFS (I)
t 26
t 34
SCLK (I)
t 36
t 35
SDATA (I)
t 27
LSB
MSB
Figure 14a. External Clocking Mode, Control/Calibration Register Write Operation
A0 (I)
t 32
TFS (I)
t 30
t 26
SCLK (I)
t 27
t 35
t 36
SDATA (I)
MSB
BIT N
t 35
t 36
BIT N+1
Figure 14b. External Clocking Mode, Control/Calibration Register Write Operation
(TFS Returns High During Write Operation)
REV. F
–23–
AD7712
SIMPLIFYING THE EXTERNAL CLOCKING MODE
INTERFACE
START
In many applications, the user may not require the facility of
writing to the on-chip calibration registers. In this case, the
serial interface to the AD7712 in external clocking mode can be
simplified by connecting the TFS line to the A0 input of the
AD7712 (see Figure 15). This means that any write to the device
will load data to the control register (since A0 is low while TFS
is low), and any read to the device will access data from the output data register or from the calibration registers (since A0 is
high while RFS is low). It should be noted that in this arrangement the user does not have the capability of reading from the
control register.
CONFIGURE AND
INITIALIZE ␮C/␮P
SERIAL PORT
BRING
RFS, TFS HIGH
POLL DRDY
RFS
FOUR INTERFACE LINES
SDATA
SCLK
DRDY
AD7712
LOW?
TFS
NO
YES
A0
BRING
RFS LOW
Figure 15. Simplified Interface with TFS Connected to A0
ⴛ3
Another method of simplifying the interface is to generate the
TFS signal from an inverted RFS signal. However, generating
the signals the opposite way around (RFS from an inverted
TFS) will cause writing errors.
READ
SERIAL BUFFER
BRING
MICROCOMPUTER/MICROPROCESSOR INTERFACING
RFS HIGH
The AD7712’s flexible serial interface allows easy interface to
most microcomputers and microprocessors. Figure 16 shows a
flowchart diagram for a typical programming sequence for reading data from the AD7712 to a microcomputer while Figure 17
shows a flowchart diagram for writing data to the AD7712.
Figures 18, 19, and 20 show some typical interface circuits.
REVERSE
ORDER OF BITS
The flowchart of Figure 16 is for continuous read operations
from the AD7712 output register. In the example shown, the
DRDY line is continuously polled. Depending on the microprocessor configuration, the DRDY line may come to an
interrupt input, in which case the DRDY will automatically
generate an interrupt without being polled. Reading the serial
buffer could be anything from one read operation up to three
read operations (where 24 bits of data are read into an 8-bit
serial register). A read operation to the control/calibration
registers is similar, but, in this case, the status of DRDY can
be ignored. The A0 line is brought low when the RFS line is
brought low when reading from the control register.
The flowchart also shows the bits being reversed after they have
been read in from the serial port. This depends on whether the
microprocessor expects the MSB of the word first or the LSB of
the word first. The AD7712 outputs the MSB first.
Figure 16. Flowchart for Continuous Read
Operations to the AD7712
The flowchart in Figure 17 is for a single 24-bit write operation
to the AD7712 control or calibration registers. This shows data
being transferred from data memory to the accumulator before
being written to the serial buffer. Some microprocessor systems
will allow data to be written directly to the serial buffer from data
memory. Writing data to the serial buffer from the accumulator
will generally consist of either two or three write operations,
depending on the size of the serial buffer.
The flowchart also shows the option of the bits being reversed
before being written to the serial buffer. This depends on
whether the first bit transmitted by the microprocessor is the
MSB or the LSB. The AD7712 expects the MSB as the first bit
in the data stream. In cases where the data is being read or
being written in bytes and the data has to be reversed, the bits
will have to be reversed for every byte.
–24–
REV. F
AD7712
Table VII shows some typical 8XC51 code used for a single
24-bit read from the output register of the AD7712. Table VIII
shows some typical code for a single write operation to the control register of the AD7712. The 8XC51 outputs the LSB first
in a write operation while the AD7712 expects the MSB first, so
the data to be transmitted has to be rearranged before being
written to the output serial register. Similarly, the AD7712
outputs the MSB first during a read operation while the 8XC51
expects the LSB first. Therefore, the data that is read into the
serial buffer needs to be rearranged before the correct data-word
from the AD7712 is available in the accumulator.
START
CONFIGURE AND
INITIALIZE ␮C/␮P
SERIAL PORT
BRING RFS, TFS
AND A0 HIGH
LOAD DATA FROM
ADDRESS TO
ACCUMULATOR
Table VII. 8XC51 Code for Reading from the AD7712
REVERSE
ORDER OF
BITS
BRING TFS
AND A0 LOW
ⴛ3
WRITE DATA FROM
ACCUMULATOR TO
SERIAL BUFFER
BRING TFS
AND A0 HIGH
END
Figure 17. Flowchart for Single Write Operation
to the AD7712
AD7712 to 8051 Interface
Figure 18 shows an interface between the AD7712 and the
8XC51 microcontroller. The AD7712 is configured for its
external clocking mode, while the 8XC51 is configured in its
Mode 0 serial interface mode. The DRDY line from the AD7712
is connected to the Port P1.2 input of the 8XC51, so the DRDY
line is polled by the 8XC51. The DRDY line can be connected
to the INT1 input of the 8XC51 if an interrupt driven system is
preferred.
DVDD
SYNC
P1.0
8XC51
RFS
P1.1
TFS
P1.2
P1.3
DRDY
A0
P3.0
SDATA
P3.1
AD7712
SCLK
MODE
MOV SCON,#00010001B; Configure 8051 for MODE 0
Operation
MOV IE,#00010000B;
Disable All Interrupts
SETB 90H;
Set P1.0, Used as RFS
SETB 91H;
Set P1.1, Used as TFS
SETB 93H;
Set P1.3, Used as A0
MOV R1,#003H;
Sets Number of Bytes to Be Read
in A Read Operation
MOV R0,#030H;
Start Address for Where Bytes
Will Be Loaded
MOV R6,#004H;
Use P1.2 as DRDY
WAIT:
NOP;
MOV A,P1;
Read Port 1
ANL A,R6;
Mask Out All Bits Except DRDY
JZ READ;
If Zero Read
SJMP WAIT;
Otherwise Keep Polling
READ:
CLR 90H;
Bring RFS Low
CLR 98H;
Clear Receive Flag
POLL:
JB 98H, READ1
Tests Receive Interrupt Flag
SJMP POLL
READ 1:
MOV A,SBUF;
Read Buffer
RLC A;
Rearrange Data
MOV B.0,C;
Reverse Order of Bits
RLC A; MOV B.1,C; RLC A; MOV B.2,C;
RLC A; MOV B.3,C; RLC A; MOV B.4,C;
RLC A; MOV B.5,C; RLC A; MOV B.6,C;
RLC A; MOV B.7,C;
MOV A,B;
MOV @R0,A;
Write Data to Memory
INC R0;
Increment Memory Location
DEC R1
Decrement Byte Counter
MOV A,R1
JZ END
Jump if Zero
JMP WAIT
Fetch Next Byte
END:
SETB 90H
Bring RFS High
FIN:
SJMP FIN
Figure 18. AD7712 to 8XC51 Interface
REV. F
–25–
AD7712
Table VIII. 8XC51 Code for Writing to the AD7712
MOV SCON,#00000000B;
MOV IE,#10010000B;
MOV IP,#00010000B;
SETB 91H;
SETB 90H;
MOV R1,#003H;
MOV R0,#030H;
MOV A,#00H;
MOV SBUF,A;
WAIT:
JMP WAIT;
INT ROUTINE:
NOP;
MOV A,R1;
JZ FIN;
DEC R1;
MOV A,@R;
INC R0;
RLC A;
AD7712 to 68HC11 Interface
Configure 8051 for MODE 0
Operation & Enable Serial Reception
Enable Transmit Interrupt
Prioritize the Transmit Interrupt
Bring TFS High
Bring RFS High
Sets Number of Bytes to Be Written
in a Write Operation
Start Address in RAM for Bytes
Clear Accumulator
Initialize the Serial Port
Figure 19 shows an interface between the AD7712 and the
68HC11 microcontroller. The AD7712 is configured for its
external clocking mode, while the SPI port is used on the
68HC11, which is in its single-chip mode. The DRDY line
from the AD7712 is connected to the Port PC2 input of the
68HC11 so the DRDY line is polled by the 68HC11. The
DRDY line can be connected to the IRQ input of the 68HC11,
if an interrupt driven system is preferred. The 68HC11 MOSI
and MISO lines should be configured for wired-OR operation.
Depending on the interface configuration, it may be necessary
to provide bidirectional buffers between the 68HC11 MOSI
and MISO lines.
Wait for Interrupt
The 68HC11 is configured in the master mode with its CPOL
bit set to a Logic 0 and its CPHA bit set to a Logic 1. With a
10 MHz master clock on the AD7712, the interface will operate
with all four serial clock rates of the 68HC11.
Interrupt Subroutine
Load R1 to Accumulator
If Zero Jump to FIN
Decrement R1 Byte Counter
Move Byte into the Accumulator
Increment Address
Rearrange Data—From LSB First
to MSB First
MOV B.0,C; RLC A; MOV B.1,C; RLC A;
MOV B.2,C; RLC A; MOV B.3,C; RLC A;
MOV B.4,C; RLC A; MOV B.5,C; RLC A;
MOV B.6,C; RLC A: MOV B.7,C; MOV A,B;
CLR 93H;
Bring A0 Low
CLR 91H;
Bring TFS Low
MOV SBUF,A;
Write to Serial Port
RETI;
Return from Subroutine
FIN:
SETB 91H;
Set TFS High
SETB 93H;
Set A0 High
RETI;
Return from Interrupt Subroutine
DVDD
SS
PC0
68HC11
DVDD
SYNC
RFS
PC1
TFS
PC2
DRDY
PC3
A0
SCK
SCLK
AD7712
MISO
SDATA
MOSI
MODE
Figure 19. AD7712 to 68HC11 Interface
–26–
REV. F
AD7712
through the 500 Ω resistor. The AD7712 can handle an input
span as low as 3.2 ⫻ VREF (= 8 V with a VREF of 2.5 V) even
though the nominal input voltage range for the input is 10 V.
Therefore, the full span of the A/D converter can be used for
measuring the current between 4 mA and 20 mA.
APPLICATIONS
4–20 mA LOOP
The AD7712’s high level input can be used to measure the
current in 4–20 mA loop applications as shown in Figure 20. In
this case, the system calibration capabilities of the AD7712 can
be used to remove the offset caused by the 4 mA flowing
ANALOG +5V SUPPLY
AVDD
REF REF
IN (–) IN (+)
DVDD
VBIAS
REF OUT
AVDD
2.5V REFERENCE
4.5␮A
CHARGE-BALANCING A/D
CONVERTER
AIN1(+)
M
U
X
AIN1(–)
AUTO-ZEROED
⌺–⌬
MODULATOR
PGA
SYNC
DIGITAL
FILTER
STANDBY
A = 1 – 128
AIN2
4–20mA
LOOP
VOLTAGE
ATTENUATION
MCLK IN
CLOCK
GENERATION
MCLK OUT
500⍀
SERIAL INTERFACE
CONTROL
REGISTER
AD7712
OUTPUT
REGISTER
AGND DGND VSS
RFS TFS MODE SDATA SCLK DRDY A0
Figure 20. 4–20 mA Loop Measurement Using the AD7712
OUTLINE DIMENSIONS
24-Lead Standard Small Outline Package [SOIC]
Wide Body
(RW-24)
Dimensions shown in millimeters and (inches)
15.60 (0.6142)
15.20 (0.5984)
24
13
7.60 (0.2992)
7.40 (0.2913)
1
12
2.65 (0.1043)
2.35 (0.0925)
10.65 (0.4193)
10.00 (0.3937)
0.75 (0.0295)
ⴛ 45ⴗ
0.25 (0.0098)
0.30 (0.0118)
0.10 (0.0039)
COPLANARITY
0.10
1.27 (0.0500)
BSC
0.51 (0.0201)
0.31 (0.0122)
8ⴗ
0ⴗ
SEATING
0.33
(0.0130)
PLANE
0.20 (0.0079)
1.27 (0.0500)
0.40 (0.0157)
COMPLIANT TO JEDEC STANDARDS MS-013AD
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN
REV. F
–27–
AD7712
OUTLINE DIMENSIONS
24-Lead Ceramic Dual In-Line Package [CERDIP]
(Q-24)
0.098 (2.49)
MAX
0.005 (0.13)
MIN
24
C01177–0–3/04(F)
Dimensions shown in inches and (millimeters)
0.310 (7.87)
0.220 (5.59)
13
PIN 1
1
0.200 (5.08)
MAX
12
0.060 (1.52)
0.015 (0.38)
1.280 (32.51) MAX
0.320 (8.13)
0.290 (7.37)
0.150 (3.81)
MIN
0.200 (5.08)
0.125 (3.18)
0.070 (1.78) SEATING
PLANE
0.030 (0.76)
0.100
(2.54)
BSC
0.023 (0.58)
0.014 (0.36)
0.015 (0.38)
0.008 (0.20)
15
0
CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN
24-Lead Plastic Dual In-Line Package [PDIP]
(N-24)
Dimensions shown in inches and (millimeters)
1.185 (30.01)
1.165 (29.59)
1.145 (29.08)
24
13
1
12
0.180
(4.57)
MAX
0.150 (3.81)
0.130 (3.30)
0.110 (2.79)
0.295 (7.49)
0.285 (7.24)
0.275 (6.99)
0.015 (0.38) MIN
0.022 (0.56)
0.018 (0.46)
0.014 (0.36)
0.100
(2.54)
BSC
0.060 (1.52) SEATING
0.050 (1.27) PLANE
0.045 (1.14)
0.325 (8.26)
0.310 (7.87)
0.300 (7.62)
0.150 (3.81)
0.135 (3.43)
0.120 (3.05)
0.015 (0.38)
0.010 (0.25)
0.008 (0.20)
COMPLIANT TO JEDEC STANDARDS MO-095AG
CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN
Revision History
Location
Page
3/04—Data Sheet changed from REV. E to REV. F.
Changes to SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Updated ORDERING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Deleted AD7712 to ADSP-2105 Interface section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Changes to AD7712 to 68HC11 Interface section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Updated OUTLINE DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
–28–
REV. F
Similar pages