COMCHIP Glass Passivated Bridge Rectifiers GBU10005-G Thru. GBU1010-G Reverse Voltage: 50 to 1000V Forward Current: 10A RoHS Device GBU Features -Surge overload rating - 220 amperes peak. -Ideal for printed circuit board. 0.437(11.1) 0.430(10.9) 0.874(22.2) 0.860(21.8) 0.126(3.2)*45° 0.139(3.53) 0.133(3.37) Chamfer 0.161(4.1) 0.134(3.4) Mechanical Data 0.232(5.90) 0.213(5.40) 0.401(10.2) 0.392(9.80) 0.752(19.1) 0.720(18.3) -Epoxy: U/L 94-V0 rate flame retardant. -Case: Molded plastic, GBU -Mounting position: Any -Weight: 3.91grams(approx.). 0.073(1.85) 0.057(1.45) 0.100(2.54) 0.085(2.16) 0.720(18.29) 0.680(17.27) 0.047(1.2) 0.035(0.9) 0.106(2.7) 0.091(2.3) 0.080(2.03) 0.065(1.65) 0.022(0.56) 0.018(0.46) 0.210(5.3) 0.190(4.8) 0.210(5.3) 0.190(4.8) 0.210(5.3) 0.190(4.8) Dimensions in inches and (millimeter) Maximum ratings and electrical characteristics O Rating at 25 C ambient temperature unless otherwise specified. Single phase, half wave ,60Hz, resistive or inductive load. For capacitive load, derate current by 20% Symbol GBU 10005-G GBU 1001-G Maximum reverse peak repetitive voltage VRRM 50 100 Maximum RMS bridge input voltage VRMS 35 Maximum DC blocking voltage VDC 50 Parameter Maximum average forward (With heatsink Note2) rectified current @Tc=100°C (without hestsink) I(AV) Peak forward surage current , 8.3ms single half sine-wave Super imposed on rated load (JEDEC Method) IFSM Maximum forward voltage at 5.0A DC VF Maximum DC reverse current at rate DC blocking voltage @TJ=25°C @TJ=125°C 2 GBU 1002-G GBU 1004-G GBU 1006-G GBU 1008-G GBU 1010-G Unit 200 400 600 800 1000 V 70 140 280 420 560 700 V 100 200 400 600 800 1000 V 10.0 3.0 220 A 1.0 V 10.0 IR 500 2 A μA 2 I T rating for fusing (t<8.3ms) It 200 As Typical junction capacitance per element (Note 1) CJ 70 pF RθJC 2.2 °C/W TJ -55 to +150 °C TSTG -55 to +150 °C Typical thermal resistance T Operating temperature range Storage temperature range Notes: 1. Measured at 1.0MHz and applied reverse voltage of 4.0V DC. 2. Device mounted on 100mm*100mm*1.6mm Cu plate heatsink. Company reserves the right to improve product design , functions and reliability without notice. REV:A Page 1 QW-BBR84 Comchip Technology CO., LTD. Glass Passivated Bridge Rectifiers Rating and Characteristics Curves (GBU10005-G Thru. GBU1010-G) Fig.2- Maximum Forward Surge Current Fig.1- Derating Curve Output Rectified Current 400 Peak Forward Surge Current, (A) Average Forward Output Current, (A) 40 30 20 10 0.0 0 50 100 350 300 250 200 150 50 0 150 PULSE WIDTH 8.3ms SINGLE HALF-SINE-WAVE (JEDEC METHOD) 100 1 10 Case Temperature, (°C ) Number Of Cycle At 60Hz Fig.4- Typical Reverse Characteristics Fig.3- Typical Forward Characteristics Instantaneous Reverse Current, (µA) Instantaneous Forward Current, (A) 100 10 1.0 0.1 0.01 0.4 0.6 0.8 1.0 1.2 100 1.4 10.0 1.0 0.1 TJ=25°C 0.01 1.6 Instantaneous Forward Voltage , (V) 0 20 40 60 80 100 120 140 Percent of Rated Peak Reverse Voltage, (V) Company reserves the right to improve product design , functions and reliability without notice. REV: A Page 2 QW-BBR84 Comchip Technology CO., LTD. Glass Passivated Bridge Rectifiers Marking Code Part Number Marking code GBU10005-G GBU10005 GBU1001-G GBU1001 GBU1002-G GBU1002 GBU1004-G GBU1004 GBU1006-G GBU1006 GBU1008-G GBU1008 GBU1010-G GBU1010 Standard Packaging TUBE PACK Case Type TUBE ( pcs ) GBU 20 BOX ( pcs ) 1000 Company reserves the right to improve product design , functions and reliability without notice. REV: A Page 3 QW-BBR84 Comchip Technology CO., LTD.