AIMTEC AMEL2-15SAZ Ac-dc converter Datasheet

Series AMEL2-AZ
2Watt | AC-DC Converter
FEATURES:
•
•
•
•
•
I/O Isolation 3000VAC
Operating Temp: -40oCto +80oC
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528Vac, 47-440Hz, or 130-745 VDC
Over Load,Short Circuit Protection
• RoHS compliant
• Energy Star compliant
• Ultra small package
Models
Single output
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(mA)
AMEL2-3.3SAZ
AMEL2-5SAZ
AMEL2-12SAZ
AMEL2-15SAZ
AMEL2-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
600
400
166
133
83
AMEL2-3.3SBAZ
AMEL2-5SBAZ
AMEL2-12SBAZ
AMEL2-15SBAZ
AMEL2-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
AMEL2-5DAZ
AMEL2-12DAZ
AMEL2-15DAZ
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
-40 to +80
-40 to +80
-40 to +80
±5
±12
±15
200
83
67
AMEL2-5DBAZ
AMEL2-12DBAZ
AMEL2-15DBAZ
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
-40 to +80
-40 to +80
-40 to +80
±5
±12
±15
200
83
67
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
AMEL2-512DAZ
90-305/47-440
130-430
-40 to +80
5/12
170/70
AMEL2-512DBAZ
90-528/47-440
130-745
-40 to +80
5/12
170/70
Model
230
277
2200
1100
680
560
470
70
71
75
76
80
68
66
72
73
77
66
64
69
70
75
600
400
166
133
83
2200
1100
680
560
470
62
70
74
76
67
62
70
73
76
67
61
69
71
74
66
Output
Current max
(mA)
Maximum
capacitive
Load
(µF)
Models
Dual Asymmetrical output
Model
www.aimtec.com
F 052e R8.C
Output
Voltage
(V)
Tel: +1 514 620 2722
1 of 4
Efficiency
(%)
115
Models
Dual output
Model
Maximum
capacitive
Load
(µF)
Output
Current max
(mA)
VAC
VAC
VAC
VAC
54
62
64
65
59
Efficiency
(%)
115
230
277
1100
680
330
70
72
71
69
72
70
68
70
69
1100
680
330
69
71
70
68
71
69
67
69
68
Maximum
capacitive
Load
(µF)
480
VAC
VAC
VAC
480
VAC
63
62
61
Efficiency
(%)
115
230
277
1100
66
66
65
1100
65
65
64
VAC
VAC
VAC
480
VAC
56
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL2-AZ
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Single Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
2Watt | AC-DC Converter
Conditions
Typical
Recommended slow blow type
1
≦0.5
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Maximum
60
30
25
20
10
15
20
30
0.15
Conditions
Typical
Conditions
Typical
Conditions
Typical
±5
±5
±5
100
25% load step
±2
0
3.3V&5V with 680 μF(E/C)
300
Ripple & Noise
12V&15V with 220uF (E/C)
300
24V with 470 uF (E/C)
300
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1μFM/C and 115/230/277/480VAC (typical input) withFull Load.
Dual Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Cross regulation
Transient Recovery Time
Transient Response Deviation
Minimum load
Full load (typical)*
LL-HL, Full Load
0-100% load (typical)*
±5
±5
±5
±5
200
25% load step
±2
0
5D/12D/15D with 220uF (E/C)
200
Ripple & Noise
512D with 220uF (E/C)
300
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1μFM/C and 115/230/277/480VAC (typical input) withFull Load.
*5D/12D/15D Model with symmetric load change and 512D Model with asymmetric load change.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
General Specifications
Parameters
Switching frequency
Over Load protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Humidity
Case material
Weight
Full load
LL-HL
0-100% load
25% load change
30sec
>1000
Conditions
Typical
100
>125%
Auto recovery
Fold back
See de-rating chart
-40 to +80
-40 to +85
Maximum
Maximum
Units
mA
mA
mA
mA
A
A
A
A
mA
A
W
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
Units
%
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
Rated
Units
Maximum
Units
3000
VAC
MΩ
KHz
o
C
C
o
C
% RH
o
100
Non condensing
20~95
Plastic resin + Fiberglass (flammability to UL 94V-0)
21
g
90-305VAC
1.10 x 0.90 x 0.57 inches (28.00 x 23.00 x 14.50 mm)
Dimensions (L x W x H)
90-528VAC
1.10 x 0.90 x 0.67 inches (28.00 x 23.00 x 17.00 mm)
o
MTBF
>400 000 hrs (MIL-HDBK -217F, t=+25 C)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
www.aimtec.com
F 052e R8.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL2-AZ
2Watt | AC-DC Converter
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB(underspecification), CSA
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity (1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Canadian Safety Agency
IEC/EN/UL 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ &DAZ:Level2,SBAZ&DBAZ:Level 1)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
CAN/CSA-C22.2 NO. 60950-1-07
Derating
Free Air Convection
70 ºC
Output Power %
100
80
60
Safe Operating Area
40
20
70
0
-40
-20
0
20
40
60
80
100
Ambient Temperature º C
www.aimtec.com
F 052e R8.C
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL2-AZ
2Watt | AC-DC Converter
Pin Out Specifications
Pin
Single
1
2
3
4
5
6
7
Dual
NC
NC
+V Output
GND
No Pin
AC Input (L)
AC Input (N)
NC
NC
+V Output
GND
-V Output
AC Input (L)
AC Input (N)
Dimensions
28.00
(1.10)
3.175
3.175
(0.125) (0.125)
1
4
3
1
5
Top View
3
4
5
Temperature measuring point
23.00
15.875
Top View
(0.90)
2
14.50
(0.625)
7
6
15.875
6.35
(0.625)
(0.25)
2
7
DIV: 5.00 (0.20)
1£ X
10.0 ( £ X
0.40)
AMEL-S/DAZ
Side View
(0.57)
6
7£ X
0.80 ( £ X
0.03)
3.18
(0.13)
Dimensions mm (inch)
Case Tolerance ¡ Ó
0.50 (¡ Ó
0.02)
Pin Diameter 0.80¡ Ó
0.05 (0.03¡ Ó
0.002)
Pin Pitch Tolerance ¡ Ó
0.50 (¡ Ó
0.02)
0.80
(0.03)
17.00
AMEL-SB/DBAZ
Side View
(0.69)
3.18
(0.13)
0.80
(0.03)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.C
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only