AIMTEC AMEL12-CJZ Continuous short circuit protection Datasheet

Click on Series name for product info on aimtec.com
Series AMEL12-CJZ
12 Watt | AC-DC / DC-DC Converter
Picture coming soon
FEATURES:
• I/O Isolation 4000VAC
• Operating Temp: -25°C to +70°C
• Over current, Over Voltage
• Input: 85-264VAC, 47-440Hz, or 100-370VDC
•
•
•
•
Low no load consumption ≤0.3W
Continuous Short Circuit Protection
Up to 83% efficiency
Low ripple and noise
Models
Single output
Model
AMEL12-3.3SCJZ
AMEL12-5SCJZ
AMEL12-15SCJZ
AMEL12-24SCJZ
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
100-370
100-370
100-370
100-370
Max
Output
wattage
(W)
7.9
12
12
12
Output
Voltage
(V)
Output
Current
max (A)
Maximum
capacitive
load
(µF)
Efficiency
(%)
3.3
5
15
24
2.4
2.4
0.8
0.5
10,000
10,000
2,700
1,500
74
78
82
83
*Output power must not exceed the listed values.
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Conditions
Typical
115VAC
230VAC
115VAC
230VAC
0.28
0.19
10
20
slow blow type
No Load
3.15
Conditions
Typical
3.3V output
Others
Full load
10-100% load
20MHz bandwidth
115VAC
230VAC
±3
±2
±0.5
±1
Maximum
Units
≤0.3
A
A
A
A
mA
A
W
Maximum
Units
0.25
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Hold up time
%
%
%
mV p-p
ms
ms
100
24
120
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
Typical
60 sec
Rated
Units
4000
VAC
MΩ
>1000
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Operating temperature
Maximum case temperature
www.aimtec.com
F 052e R8
Conditions
Typical
100% load
Maximum
100
Class II
≥110
Zener Diode Clamp
Continuous
Auto recovery
-25 to +70
Auto recovery
See derating table
KHz
% of Iout
o
100
Tel: +1 514 620 2722
1 of 3
Units
C
C
o
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL12-CJZ
12 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Typical
Maximum
Units
o
-25 to +105
±0.02
Free air convection
C
o
%/ C
Non condensing
95
Heat resistant black Plastic (flammability to UL 94V-0)
60
2.12 x 1.13 x 0.93 inches
53.80 x 28.80 x 23.50 mm
o
> 300 000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load
% RH
g
Safety Specifications
Parameters
Agency approvals
Standards
cULus, CE pending
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Pin Out Specifications
Pin
Single
1
2
3
4
AC Input (N)
AC Input (L)
+V Output
-V Output
Dimensions
53.80
(2.12)
45.72
(1.80)
Case Temperature
Measurement point
1
3
1
10.16
(0.40)
28.80 20.32
(1.13) (0.80)
TOP VIEW
4
2
23.50
(0.93)
Ø 1.00
(0.04)
Tel: +1 514 620 2722
2 of 3
3
4
5
Ø 1.5 (Ø 0.06)
6.00
(0.24)
F 052e R8
TOP VIEW
+
2
www.aimtec.com
Meets IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 4
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11 Class 2
DIV: 5.08 (0.2)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)
Pin Pitch Tolerance ±0.35 (±0.014)
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL12-CJZ
12 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection at 25°C
100
100
80
Output Power (%)
Output power (%)
Free Air Convection
Safe Operating Area
75
Input 100-240VAC or
120-340VDC
60
50
40
20
80
70
60
Safe Operating Area
40
20
0
85
100
(100) (120)
0
70
55
- 25
-20
0
20
40
60
80
100
Ambient Temperature º C
240
(340)
264
(370)
Input Voltage VAC (VDC)
Typical application circuit
AC L
FUSE
1A/300V
MOV
S20K350
AC N
Model
3.3 & 5 Vout
12 & 15 Vout
24 Vout
Single Output
NTC
4
AC L
AC
DC
AC N
C2
220 µF / 10V
120 µF / 25V
68 µF / 35V
+ Vout
C1
C2
1µF/50V
+
TVS
- Vout
3
TVS
7V
20V
30V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages