www.osram.de/LED-Systeme LINEARlight ADVANCED - LR14A preliminary Datasheet Product benefits Broad portfolio (Eco, Advanced, Power) with the same form factor offering high variety in luminous flux and color temperatures while being simply exchangeable Modules can be joined together in series to make seamless strip lighting, without any further accessory Intermateable with LINEARlight Power and ECO Low maintenance costs thanks to a life of up to 50k hours Module efficiency up to 85 lm/W Applications Shelf, cabinet & undercabinet lighting Technical Operating Data Product Color Number Voltage Power Radiance Color Temp. Lum. Flux of LEDs [V DC]* [W]* Angle [°]* [K]* [lm] LR14A-W2F-830 Weiß 14 24 4.7 120 3000 400 LR14A-W2F-840 Weiß 14 24 4.7 120 4000 400 All Data are related to the entire module. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data *) Preliminary Data Technical Features Metal core board equipped with 14 LEDs Seamless concept with up to 10 modules in series Luminous flux 1400 lm/m Lifetime 50.000 h @L70 @tcmax 65°C SMD-4 plug connector (male/female) on both Best efficacy in combination with OSRAM OPTOTRONIC® control gears sides of the PCB Consistent white light < 3 SDCM Operation only with constant voltage control gears (see page 2 for recommendations) Color rendering Ra typ. 85 Mounting holes for simple fixing with M3 screws With optional accessory upgrade to individual overall modules possible (see page 4) Dimmable LINEARlight ADVANCED LR14A – 10.04.2012 Seite 1 von 4 www.osram.de/LED-Systeme Minimum and Maximum Ratings Product Operating Temperature Storage Temperature Voltage Range Reverse Voltage at Tc-Point [C°]* [C°]* [V dc]* [V dc]* LR14A-W2F-830 -30 … 65 -30 … 90 23 … 25 25 LR14A-W2F-840 -30 ... 65 -30 … 90 23 … 25 25 *) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module. Exceeding maximum ratings for operating current will cause hazardous overload and will likely destroy the LED Module. The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below. Drawing D Tc R l3 l2 l 280 mm b 20 mm h 2 mm l1 20 mm l2 160 mm l3 60 mm R 1,4+0,2 mm D 3.2 mm Driver System recommendation OPTOTRONIC LED Module LINEARlight Advanced Power lm/m OT8 200-240/24 OT20 (S) 200-240/24 OT50* 200-240/24 OT75 (E) 200-240/24 OTi Dali 75 220-240/24 4,7 W 1400 1 module 2 - 4 modules 5 - 9 modules 5 - 10 modules 5 - 10 modules Length 280 mm 560 - 1120 mm 1400 - 2520 mm 1400 - 2800 mm 1400 - 2800 mm Luminous flux 400 lm 200 - 600 lm 2000 - 3600 lm 2000 - 4000 lm 2000 - 4000 lm System recommendation Light Management Systems LED Module LINEARlight Advanced Power lm/m OT DIM OTi DALI DIM OTi DALI DIM LI OT DMX 3x2.5A DIM OT DMX 9x2A DIM SO 4,7 W 1400 10 modules 10 modules 10 modules 3x10 modules 9x7 modules * Under preparation LINEARlight ADVANCED LR14A – 10.04.2012 Seite 2 von 4 www.osram.de/LED-Systeme Safety Information The LED module itself and all its components must not be mechanically stressed. The mounting of the module has to be done on a metal heat sink. Please find matching LINEARlight Track at page 4 (Ordering guide). Assembly must not damage or destroy conducting paths on the circuit board. To avoid mechanical damage to the connecting cables, the module should be attached securely to the intended substrate. Heavy vibration should be avoided. In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically stabilised power supply protecting against short circuits, overload and overheating. To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384. Also check for the mark of an independent authorized certification institute. Please see the relevant brochure for more detailed information (see "Related and Further Information"). OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation. Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Observe correct polarity! Depending on the product incorrect polarity will lead to emission of red or no light. The module can be destroyed! Correct polarity immediatelly! (see "reverse voltage", page 2). Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module. Pay attention to ESD steps when mounting the module. Use only LR-4PIN CONNECTsystem for electrical installation. Three types of connectors are available: LR-4PIN - Feeder with 500 mm cable length. LR-4CONN-45 - Connector for through wiring with 45 mm cable length. LR-4CONN-250 - Connector for through wiring with 250 mm cable length. The LED module can typically survive levels of up to 4 Amperes. As a general design precaution, if the maximum output current of th power supply is more than 4 Amperes, fast-blow fuses should be incorporated into the wiring plan. Electrical contact is achieved with the contact cables. A maximum number of 10 modules can be installed consecutively from one power feed. Operation with more than 10 consecutive modules will reduce photometric performance and exceed the current carrying capacity of the module. Installation of up-to 14 modules on one OPTOTRONIC® 75W has to be realised by either feeding the power to the centre or by splitting the power feed to contact groups of the maximum allowed number of modules in-line. The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements. If the IP rating of the fixture should be higher than IP20, the design of the housing should be according to the IP standards in the application. LINEARlight ADVANCED LR14A – 10.04.2012 Seite 3 von 4 www.osram.de/LED-Systeme Assembly Information The mounting of the module has to be done on a metal heat sink In order to optimize the thermal management the metal surface needs to be clean (dirt and oil free) and planar for the best contact with the LED module. To connect one module, the feeder LR-4PIN-500 must be plugged in the "INPUT" side of the module. for two or more modules, the "OUTPUT"-side of the first module must be connected with the "INPUT"-side of following module via LR-4CONN-45 /-250. Please connect more boards as described above. Ordering Guide Product group Product EAN* LINEARlight ADVANCED LR14A-W2F-830 4008321 978400 LINEARlight ADVANCED LR14A-W2F-840 4008321 971531 8 CONNECTsystem feeder LR-4PIN-500 4008321 971852 16 CONNECTsystem LR-4CONN-45 4008321 971814 16 CONNECTsystem LR-4CONN-250 4008321 994400 16 LINEARlight Track LT-280 4008321 975966 8 LINEARlight Track LT-560 4008321 975980 8 LINEARlight Track end caps LT-ENDCAP 4008321 976109 16 LINEARlight Track Mounting bracket LT-MB 4008321 994424 16 Optic Tray OTR-280-LR14A/E 4008321 994448 8 Optic 30° OPLR1x1-30 4008321 976000 140 Optic 80° OPLR1x1-80 4008321 976024 140 OPLR1x1-20x50 4008321 976048 140 Optic 20°x 50° S-Unit* 8 *) EAN: Ordering number per single module; S-Unit: Modules per shipping unit Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves. Sales and Technical Support OSRAM AG Hellabrunner Strasse 1 D - 81536 München Germany www.osram.com +49 (0)89 6213-0 Sales and technical support is given by the local OSRAM subsidiaries. On our world wide homepage all OSRAM subsidiaries are listed with complete address and phone numbers. Related and Further Information A new approach to light 153 S006 GB OSRAM LED Systeme www.osram.de/led-systeme OPTOTRONIC® Technical Guide 130 T008 DE www.osram.de/evg-downloads OPTOTRONIC® Data sheets http://catalog.myosram.com Eulumdat Files www.osram.de/led-systeme-downloads New standards for LED control gear LINEARlight ADVANCED LR14A – 10.04.2012 www.osram.de/evg-downloads Seite 4 von 4