Vishay MLV0402E3 Smd 0402 multilayer varistor Datasheet

MLV0402E3
www.vishay.com
Vishay BCcomponents
SMD 0402 Multilayer Varistor
FEATURES
• Surface mount multilayer surge suppressor
• Inherent bidirectional clamping
• Excellent energy/volume ratio
• Suitable for reflow soldering
• Material categorization:
for definitions of compliance please see
www.vishay.com/doc?99912
APPLICATIONS
Over-voltage and transient voltage protection:
QUICK REFERENCE DATA
PARAMETER
• Data lines and I/O port protection
• Protection against ESD transients
VALUE
UNIT
DC
5.6 to 18.0
V
• Modem protection
AC
4.0 to 14.0
V
• LCD protection
Maximum clamping voltage
at 1 A
15.5 to 40
V
Capacitance range
(at 1 MHz)
90 to 360
pF
• On-board protection of IC’s and transistors
Maximum continuous voltage
Maximum energy (10/1000 μs)
Size 0402 (1005M) multilayer chip varistor with NiSn
terminations.
0.05
J
20
A
PACKAGING
-55 to 125
°C
± 0.0015
g
Available in 8 mm paper tape, component pitch 4 mm on
180 mm reels containing 10 000 pieces.
Maximum peak current
Operating temperature range
DESCRIPTION
Weight
ELECTRICAL DATA AND ORDERING INFORMATION
WORKING VOLTAGE
BREAKDOWN
VOLTAGE
MAXIMUM
CLAMPING
VOLTAGE
TYPICAL
CAPACITANCE
PART NUMBER
VRMS
VDC
Vb
VC
C
SAP
V
V
V
V
pF
MLV0402E3
< 10 μA
1 mA
1 A, 8/20 μs
1 MHz
4.0
5.6
7.1 to 9.3
15.5
360
0403T
7.0
9.0
11.0 to 14.0
20.0
230
0703T
11.0
14.0
16.0 to 20.0
30.0
120
1103T
14.0
18.0
23.0 to 28.0
40.0
90
1403T
Notes
• Sinusoidal voltage assumed as normal operating condition.
If a non-sinusoidal voltage is present, the crest voltage x 0.707 should be used for type selection.
• Breakdown voltage at a current of 1 mA, measured according to 4.5 of IEC 61051-1.
• Parts are not recommended for automotive applications.
Revision: 22-Apr-15
Document Number: 29107
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
MLV0402E3
www.vishay.com
Vishay BCcomponents
DIMENSIONS in millimeters
T
L1
W
T
L2 and L3
1.0 ± 0.1
0.5 ± 0.1
0.6 max.
0.25 ± 0.15
W
L2
L4
L1
L3


RECOMMENDED FOOTPRINT in millimeters
C
A
B
C
0.7
0.7
2.0
A
B

V/I CHARACTERISTICS
Max. clamping voltage
Max. leakage current
100
VOLTAGE (V)
014
011
007
004
10
1
0.00001
0.0001
0.001
0.01
0.1
1
10
100
CURRENT (A)
Revision: 22-Apr-15
Document Number: 29107
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer

ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Revision: 13-Jun-16
1
Document Number: 91000
Similar pages