SICK L41E-21KA1A Single-beam photoelectric safety switch Datasheet

Online data sheet
L41S-21KA1A, L41E-21KA1A
L41
SINGLE-BEAM PHOTOELECTRIC SAFETY SWITCHES
L41S-21KA1A, L41E-21KA1A | L41
SINGLE-BEAM PHOTOELECTRIC SAFETY SWITCHES
A
B
C
D
E
F
Ordering information
System part
Type
Part no.
Sender
L41S-21KA1A
6034864
L41E-21KA1A
6034865
Receiver
Other models and accessories
www.sick.com/L41
Detailed technical data
Features
H
I
J
K
L
M
N
O
P
Q
R
S
T
Scanning range
0 m ... 10 m
Number of beams
1
Optical axis
Axial
Safety-related parameters
Type
Type 4 (IEC 61496) 1)
Safety integrity level
SIL3 (IEC 61508) 1)
SILCL3 (EN 62061) 1)
Category
Category 4 (EN ISO 13849) 1)
Performance level
PL e (EN ISO 13849) 1)
PFHD (mean probability of a dangerous failure per hour)
8.1 x 10-10 (EN ISO 13849) 1)
TM (mission time)
20 years (EN ISO 13849)
1)
Only in combination with an appropriate test device, e.g., Flexi Classic or Flexi Soft.
Interfaces
Connection type
Male connector M12, 4-pin, straight
Diagnostic display
LED
Electrical data
Operating data
Protection class
III
Power consumption
≤ 30 mA / ≤ 20 mA (depending on type)
Switching output
Switching current
≤ 70 mA
Mechanical data
Design
Cylindrical
Dimensions (diameter x length)
M18 x 97.7 mm
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-09-01 12:26:26
Subject to change without notice
L41S-21KA1A, L41E-21KA1A | L41
SINGLE-BEAM PHOTOELECTRIC SAFETY SWITCHES
Housing material
Plastic
Lens material
Glass
Weight
30 g
Ambient data
Enclosure rating
IP67 (EN 60529)
Ambient operating temperature
–40 °C ... +55 °C
Storage temperature
–40 °C ... +75 °C
Air humidity
15 % ... 95 %, Non-condensing
Vibration resistance
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
Shock resistance
10 g, 16 ms (IEC 60068-2-29)
Other information
Light source
LED
Type of light
Visible red light
Wave length
660 nm
Aperture angle/receiving angle
± 2.5° / ± 2.5°
Classifications
ECl@ss 5.0
27272701
ECl@ss 5.1.4
27272701
ECl@ss 6.0
27272701
ECl@ss 6.2
27272701
ECl@ss 7.0
27272701
ECl@ss 8.0
27272701
ECl@ss 8.1
27272701
ECl@ss 9.0
27272701
ETIM 5.0
EC001831
ETIM 6.0
EC001831
UNSPSC 16.0901
46171620
Dimensional drawing (Dimensions in mm (inch))
M18 axial
97.7 (3.85)
7
(0.28)
57.5 (2.26)
17.6 15.6
(0.69) (0.61)
2017-09-01 12:26:26 | Online data sheet

Subject
to change without notice
(0.65)
Ø 16.4
LED
M12 x 1
M18 x 1
45°
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
3
L41S-21KA1A, L41E-21KA1A | L41
SINGLE-BEAM PHOTOELECTRIC SAFETY SWITCHES
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Connection diagram
3 x L41 (cascaded) on Flexi Classic main unit and extension unit
+24 V
S1
+24 V
+24 V
TE
k1
0V
0V
Q
L41S
L41E
k2
+24 V
+24 V
Q
I2
I1
A1
X1
X2
S1
S2
0V
0V
L41S
L41 E
3
UE410-MU/XU
I3
+24 V
+24V
2
1
0
TE
I4
A2
3
S3
6
7
8
9
FE
Function
Q1
Q2
Q3
Q4
EN
K1
1)
0V
0V
4 5
x
TE
y
Q
L41S
L41E
K2
k1 k2
x y
z
k1
k2
z
0V
E117081/00/2014-06-02
2) PELV
Task
Integration of three cascaded L4000 (L41) family single-beam photoelectric safety switches with a UE410-MU/XU safety controller
into a relay controller/contactor controller.
Operating mode: with restart interlock and with external device monitoring.
Function
When the input conditions are valid, the system is ready for switch-on and waits for an input signal/switch-on signal. The system is
enabled by pressing and releasing the S1 button. The related output on the UE410-MU/XU carries power. If the input conditions are
no longer met, the related outputs on the UE410-MU/XU shut down.
Possible faults
The incorrect function of the K1 and K2 contactors will be detected. The shutdown function is retained.
On manipulation (e.g., jamming) of the S1 button, the system does not enable the output current circuits.
Comments
1)
Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, the integration must be dual-channel (x/y paths). Single-channel integration in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
2)
PELV as required in EN 60204-1 / 6.4
Optical short-circuits must be avoided. Take note of the operating instructions for the integrated devices. The safety-related parameters (safety integrity level and response time) are dependent on the types used.
Recommended accessories
Other models and accessories
www.sick.com/L41
Brief description
Type
Part no.
BEF-WN-M18
5308446
Head A: female connector, M12, 4-pin, straight
Head B: cable
Cable: PVC, unshielded, 5 m
DOL-1204-G05M
6009866
Head A: female connector, M12, 4-pin, angled
Head B: cable
Cable: PVC, unshielded, 5 m
DOL-1204-W05M
6009867
Mounting brackets and plates
Mounting bracket for M18 sensors, steel, zinc coated, without mounting hardware
Plug connectors and cables
4
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-09-01 12:26:26
Subject to change without notice
L41S-21KA1A, L41E-21KA1A | L41
SINGLE-BEAM PHOTOELECTRIC SAFETY SWITCHES
Brief description
Type
Part no.
Head A: female connector, M12, 4-pin, straight
Head B: Cable: unshielded
DOS-1204-G
6007302
Head A: female connector, M12, 4-pin, angled
Head B: Cable: unshielded
DOS-1204-W
6007303
AR60
1015741
AR60 adapter,
M18 sensors
5313533
PNS75-008
1026647
Horizontal deflection, 96 mm x 124 mm reflector surface, Glass
PSK1
1005229
Deflector mirror for 90° deflection, mirror surface 97 mm x 80 mm, not suitable for
column mounting, Glass, mounting hardware included
PSK45
5306053
Alignment aids
Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into
the beam!
Adapter AR60 for M18 sensors (L41 and L21)
Deflector mirrors
Horizontal deflection, 75 mm x 80 mm reflector surface, Glass, Incl. mounting kit (2 x
swivel mount)
2017-09-01 12:26:26 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
5
Online data sheet
SICK at a glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”
Worldwide presence:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com