MORNSUN LD03-10B24R2 3w, ac-dc converter Datasheet

AC/DC Converter
LD03-10BxxR2 Series
FEATURES
3W, AC-DC converter
z Universal input range:85~264VAC/100~370VDC
z Excellent ripple and noise performance:
50mV (Typ.)
CB
z Compact size, high power density
z Protection of output over-voltage, output short
circuit, over-current
z Meets IEC60950, UL60950, EN60950 standards
RoHS
LD03-10BxxR2 ---- a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC input
voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, EMC and Safety
specifications meet the international IEC61000, UL60950 and EN60950 standards, and widely used in medical treatment, industrial,
electricity, instruments, telecommunication and civil applications. For harsh EMC environment, the application circuit in the datasheet is
strongly recommended.
Selection Guide
Model
Output Power
Nominal Output Voltage
and Current (Vo/Io)
LD03-10B03R2
2.3W
Certification
LD03-10B05R2
UL/CE
LD03-10B09R2
Efficiency
(230VAC/%,Typ.)
Max. Capacitive Load
(uF)
3.3V/700mA
66
6000
5V/600mA
74
6000
9V/330mA
75
1500
12V/250mA
77
1500
LD03-10B15R2
15V/200mA
77
1000
LD03-10B24R2
24V/125mA
78
330
LD03-10B12R2
3W
Input Specifications
Item
Operating Conditions
Input Voltage Range
Min.
Typ.
Max.
Unit
AC input
85
--
264
VAC
DC input
100
--
370
VDC
47
--
63
Hz
110VAC
--
65
--
230VAC
--
30
--
110VAC
--
10
--
230VAC
--
20
--
Input frequency
Input current
Inrush current
Leakage current
mA
A
0.1mA RMS typ. 230VAC/50Hz
Recommended External Input Fuse
1A/250V, slow fusing
Hot Plug
Unavailable
Output Specifications
Item
Output Voltage Accuracy
Operating Conditions
Min.
Typ.
Max.
3.3V output
--
±3
--
Others
--
±2
--
Unit
%
Line Regulation
Full load
--
±0.5
--
Load Regulation
10%-100% load
--
±1
--
Ripple & Noise*
20MHz bandwidth (peak-peak value)
--
50
100
mV
Temperature Drift Coefficient
--
±0.02
--
%/°C
Stand-by Power Consumption
--
0.3
--
W
Short Circuit Protection
Continuous, self-recovery
Over-current Protection
≥110%Io self-recovery
Over-voltage Protection
3.3/5VDC output
≤7.5VDC
9VDC output
≤12VDC
2015.04.17-A/1
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD03-10BxxR2 Series
12/15VDC output
Over-voltage Protection
≤20VDC
24VDC output
≤30VDC
Min. Load
Power-off Holding Time
230VAC input
1
--
--
%
--
50
--
ms
Note: *Parallel line test method is adopted to test the ripple and noise, please see AC-DC Converter Application Notes for specific operation methods.
General Specifications
Item
Operating Conditions
Min.
Test time: 1min
3000
--
Operating Temperature
-25
--
+70
Storage Temperature
-25
--
+105
Isolation Voltage
Input-output
Typ.
Max.
Case Temperature
--
--
+95
Storage Humidity
--
--
95
Wave-soldering
Welding Temperature
VAC
°C
%RH
260±5℃; time:5~10s
Manual-welding
360±10℃; time:3~5s
Switching Frequency
+55℃~+70℃
Power Derating
Unit
--
--
115
--
kHz
2.0
--
--
%/°C
Safety Standard
IEC60950,EN60950,UL60950
Safety-regulated Certification
EN60950/UL60950
Safety Class
CLASS Ⅱ
MTBF
MIL-HDBK-217F@25°C > 300,000 h
Physical Specifications
Casing Material
Black flame-retardant and heat-resistant plastic (UL94-V0)
Package Dimensions
37.00*24.50*18.00 mm
Weight
25g(Typ.)
Cooling method
Free convection
EMC Specifications
CISPR22/EN55022, CLASS A
CE
CISPR22/EN55022, CLASS B (See Fig. 2 for recommended circuit)
EMI
CISPR22/EN55022, CLASS A
RE
CISPR22/EN55022, CLASS B (See Fig. 2 for recommended circuit)
ESD
IEC/EN61000-4-2
RS
IEC/EN61000-4-3
10V/m
perf. Criteria A
IEC/EN61000-4-4
± 2kV (See Fig. 1 for typical application circuit)
perf. Criteria B
EFT
EMS
Contact ±6 kV / Air ±8 kV
perf. Criteria B
IEC/EN61000-4-4
± 4kV (See Fig. 2 for recommended circuit)
perf. Criteria B
IEC/EN61000-4-5
±1 kV (See Fig. 1 for typical application circuit)
perf. Criteria B
IEC/EN61000-4-5
±2 kV /±4 kV(See Fig. 2 for recommended circuit)
perf. Criteria B
CS
IEC/EN61000-4-6
10 Vr.m.s
perf. Criteria A
PFM
IEC/EN61000-4-8
10A/m
perf. Criteria A
Voltage dips, short interruptions
and voltage variations immunity
IEC/EN61000-4-11
Surge
0%-70%
perf. Criteria B
2015.04.17-A/1
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD03-10BxxR2 Series
Temperature Derating Cur ve
Output Power Percent(%)
Output Power Percent(%)
Product Characteristic Curve
100
70
50
Input voltage:100~240VAC
120~340VDC
20
-25
55
70
Ambi ent temperature .(℃ )
Input Voltage Derating Cur ve
100
80
76
Ambient temperatu re:2 5℃
50
20
85
100
100
240 264
120
340 370
Input Voltage
VAC
VDC
Note: ①Input voltage should be derated based on temperature derating when it is 85~100VAC/240~264VAC/100~120VDC/340~370VDC;
②This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
Efficiency Vs Output Load(Vin=230VAC)
Efficiency Vs Input Voltage(Full Load)
90
90
85
LD03-10B24R2
80
80
Efficiency(%)
Efficiency(%)
85
LD03-10B24R2
LD03-10B12R2
75
LD03-10B05R2
70
65
LD03-10B12R2
75
LD03-10B05R2
70
65
60
55
50
45
60
85
110
220
240
40
264
10
Input Voltage(VAC)
20
30
40
50
60
70
80
90
100
Output Power Percentage(%)
Design Reference
1. Typical application circuit
AC (L)
FUS E
AC (L)
C1
+Vo
C2
AC (N )
AC ( N)
RL
+
AC/DC
MOV1
TVS
C1(μF)
Model
LD03-10B03R2
LD03-10B05R2
LD03-10B09R2
LD03-10B12R2
LD03-10B15R2
LD03-10B24R2
-Vo
Fig. 1: Typical application circuit
C2(μF)
150
150
120
120
120
68
1
TVS tube
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
Note:
Output filtering capacitor C2 is electrolytic capacitor, it is recommended to apply electrolytic capacitor with high frequency and low resistance. For
capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitance withstand voltage derating should be 80% or above. C1 is
ceramic capacitor, which is used to filter high-frequency noise. External input MOV1 is recommended to use S14K350. TVS is a recommended component to
protect post-circuits if converter fails.
2. EMC solution-recommended circuit
Can use MORNSUN’s FC-LX1D
FUSE
L DM
L CM
A C(L)
A C(L)
+Vo
CY1
MOV 1
C2
TVS1
RL
+
AC/DC
CX
CY2
A C(N )
C1
-Vo
A C(N )
Fig 2: EMC application circuit with higher requirements
2015.04.17-A/1
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD03-10BxxR2 Series
Fig 3: Recommended EMC circuit-PCB layout
Suggestions for safety regulation and wiring width: wire width ≥3mm, distance between wires ≥6mm, and distance between wire and
ground ≥6mm
Element model
MOV1
CX
LDM
LCM
CY1
CY2
FUSE
FC-LX1D
Recommended value
S14K350
0.1μF/275VAC
4.7uH/2.0A
10mH ~30mH,recommended to use MORNSUN’s FL2D-Z5-103
1nF/400VAC
1nF/400VAC
1A/250V, slow fusing, necessary
2KV/4KV EMC filter
3. For more information please find the application note on www.mornsun-power.com
Dimensions and Recommended Layout
THIRDANGLEPROJECTION
16
14
18.00[0.709]
FrontView
3
1
4.10[0.161]
13
0.60[0.024]
∅1.10[∅0.043]
30.48[1.200]
Note:Grid2.54*2.54mm
5.08[0.200]
1
13
3
Pin-Out
24.50[0.965]
17.78[0.700]
BottomView
16
14
5.08[0.200]
37.00[1.457]
Note:
Unit:mm[inch]
Pindiametertolerances:±0.10[±0.004]
Generaltolerances:±0.50[±0.020]
Pin
Function
1
AC(L)
3
AC(N)
13
NC
14
-Vo
16
+Vo
1104007201-A0
2015.04.17-A/1
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD03-10BxxR2 Series
Note:
1. Packing Information please refer to 'Product Packing Information'. Packing bag number: 58200055;
2. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25°C, humidity<75% when inputting
nominal voltage and outputting rated load;
3.
All index testing methods in this datasheet are based on our Company’s corporate standards;
4.
The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact our technician for specific information;
5.
We can provide product customization service;
The product specification may be changed at any time without prior notice.
6.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2015.04.17-A/1
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages