MINI LRPS-2-1-75+ Power splitter/combiner Datasheet

Surface Mount
LRPS-2-1-75+
LRPS-2-1-75
Power Splitter/Combiner
2 Way-0°
75Ω
2 to 500 MHz
Maximum Ratings
Operating Temperature
Storage Temperature
Features
• insertion loss 0.35 dB typ.
• high isolation, 35 dB typ.
-40°C to 85°C
-55°C to 100°C
Power Input (as a splitter)
Internal Dissipation
1W max.
Applications
0.125W max.
• VHF/UHF
• catv
• communications systems
Permanent damage may occur if any of these limits are
exceeded.
Pin Connections
SUM PORT
6
PORT 1
4
PORT 2
3
GROUND
+RoHS Compliant
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications
Electrical Specifications
ISOLATION
(dB)
FREQ.
RANGE
(MHz)
1
NOT USED
CASE STYLE: QQQ130
PRICE: $8.95 ea. QTY. (10-49)
2,5
Outline Drawing
L
INSERTION LOSS (dB)
ABOVE 3.0 dB
M
U
L
M
U
fL-fU
Typ.
Min
Typ.
Min
Typ.
Min
Typ. Max. Typ. Max. Typ. Max.
2-500
35
18
35
25
27
20
0.3
L = 2-20 MHz
M = 20-250 MHz
0.8
0.35
0.6
0.5
AMPLITUDE
UNBALANCE
(dB)
PHASE
UNBALANCE
(Degrees)
L
M
U
L
M
U
Max.
Max.
Max.
Max.
Max.
Max.
1.0
2.0
3.0
0.15
0.2
0.3
1.0
U = 250-500 MHz
Typical Performance Data
Frequency
(MHz)
Total Loss
(dB)
1
PCB Land Pattern
Suggested Layout,
Tolerance to be within ±.002
Outline Dimensions ( inch
mm )
C
.200
5.08
D
.10
2.54
E
.010
0.25
H
.420
10.67
J
.120
3.05
K
.060
1.52
L
.100
2.54
M
.020
0.51
F
.100
2.54
G
.050
1.27
wt
grams
0.55
Demo Board MCL P/N: TB-221
Suggested PCB Layout (PL-235)
Isolation
(dB)
Phase
Unbalance
(deg.)
VSWR
S
VSWR
1
VSWR
2
S-1
S-2
2.00
10.00
14.00
20.00
50.00
3.32
3.29
3.29
3.30
3.30
3.29
3.28
3.27
3.27
3.28
0.03
0.01
0.03
0.02
0.02
30.42
39.35
39.99
39.87
37.98
0.05
0.00
0.01
0.05
0.01
1.07
1.07
1.07
1.07
1.08
1.25
1.20
1.20
1.20
1.19
1.25
1.20
1.20
1.20
1.19
80.00
110.00
140.00
170.00
200.00
3.31
3.33
3.32
3.33
3.34
3.28
3.30
3.30
3.30
3.31
0.03
0.03
0.03
0.03
0.03
35.87
34.24
32.73
31.50
30.43
0.11
0.17
0.18
0.24
0.22
1.08
1.09
1.09
1.10
1.11
1.19
1.18
1.17
1.16
1.16
1.19
1.19
1.18
1.17
1.16
275.00
350.00
425.00
475.00
500.00
3.36
3.39
3.40
3.41
3.44
3.33
3.35
3.37
3.37
3.39
0.03
0.04
0.03
0.04
0.05
28.50
27.19
26.27
25.83
25.63
0.38
0.40
0.49
0.48
0.49
1.14
1.17
1.20
1.22
1.24
1.13
1.11
1.09
1.09
1.10
1.13
1.10
1.08
1.08
1.08
1. Total Loss = Insertion Loss + 3dB splitter loss.
LRPS-2-1-75
TOTAL LOSS
4.0
50
S-1(dB)
3.8
S-2(dB)
LRPS-2-1-75
ISOLATION
45
ISOLATION (dB)
B
.31
7.87
TOTAL LOSS (dB)
A
.400
10.16
Amplitude
Unbalance
(dB)
3.6
3.4
3.2
40
35
30
25
3.0
20
0
100
200
300
400
500
0
100
FREQUENCY (MHz)
LRPS-2-1-75
VSWR
1.6
#S-VSWR
1.5
#1-VSWR
200
300
400
500
FREQUENCY (MHz)
electrical schematic
#2-VSWR
VSWR
1.4
1.3
1.2
1.1
1.0
0
100
200
300
400
500
FREQUENCY (MHz)
Notes
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp
Mini-Circuits
®
www.minicircuits.com P.O. Box 35166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected]
REV. A
M127604
LRPS-2-1-75
ED-1514/7
DJ/CP/AM
100602
Similar pages