Series AMER120C-Z up to 1700mA | AC-DC LED driver FEATURES: • • • • • Models Single output Model AMER120C-70170Z AMER120C-70170Z-P AMER120C-70170Z-PD AMER120C-60200Z Accurate Constant Current Output ±3% High Efficiency: Up to 91% Active Power Factor Correction UVLO, Short Circuit, Over Voltage Adjustable output current: 50-100% • • • • • IP65/IP67 design for indoor/outdoor Over Temperature Protection Dimmable output current: 10-100% Open circuit protection 5 Year Warranty Max Output Power (W) Input Voltage (VAC/Hz) Output Voltage Range (V) Output Current (A) Efficiency (%) 119 119 119 120 90-305/47-63 90-305/47-63 90-305/47-63 90-305/47-63 35-70 35-70 35-70 42-60 1.7 1.7 1.7 2 91 90.5 90 90 Model Nomenclature functional differences: With Suffix “-PD” With Suffix “-P” Without Suffix With manually adjustable 50-100% & fully dimmable 10-100% (0-10V/10PWM/Resistive) output current Only with manually adjustable output current: 50-100% Only with fully dimmable 10-100% (0-10V/10PWM/Resistive) output current NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Input Current Inrush current <2ms Conditions Typical 90 VAC, full load 115 VAC, cold start 305 VAC, cold start Leakage current Maximum No Load Output Short 115 VAC, full load 277 VAC, full load Input dissipation Power Factor Input Fuse Units 1.6 45 75 0.75 3.0 10.0 0.98 0.92 Arms 1.5 1.0 Sec. Sec. A mA W W 3.15A / 300V 115 VAC, full load 277 VAC, full load Start-up Time Output Specifications Parameters Current accuracy Line regulation Load regulation Ripple & Noise Output Current Ripple Current Overshoot Hold-up time (min.) Minimum Load Voltage Conditions Typical LL to HL Full Output Voltage Range ±3 ±1 ±1 Full load, 16.7-20ms duration LL to HL, full load at cold start, % of rated output current Maximum Units 4.5 % % % V p-p A p-p % ms 1.5 10 0.5 See Models Table Above Isolation Specifications Parameters I/O Isolation Voltage Isolation Resistance www.aimtec.com F 052.1e R3 Conditions I/P – O/P I/P – FG O/P – FG I/P – O/P, 500Vdc Typical >100MΩ Tel: +1 514 620 2722 1 of 6 Rated Units 3750 2000 500 VAC VAC VAC VAC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-Z up to 1700mA | AC-DC LED driver Isolation Capacitance 3800 pF General Specifications Parameters Conditions Switching frequency Over Voltage protection Short circuit protection Open circuit protection Over Temperature Protection Operating temperature Maximum case temperature Warranty case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting material IP Rating Weight Dimensions (L X W X H) MTBF Typical Maximum Units 130 KHz V 75 Continuous, Hiccup mode, auto recovery Continuous Threshold – Shutdown Output +106 Hysteresis – Auto Recovery +90 With Derating over 60oC -40 to +70 90 -40 to 73 -40 to +85 oC oC oC oC oC 0.03 oC % / oC 95 % RH Free Air Convection Metal (Aluminum) Polysiloxane IP67 850 6.93 x 2.70 x 1.65 inches 176.0 x 68.7 x 42.0 mm >400,000 hrs (MIL-HDBK-217F at +25°C) g Safety Specifications Parameters Standards Electromagnetic Interference Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient / Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Electromagnetic Immunity Requirements Applies to Lighting Equipment Pin Definition Wire Pin Blue Brown Yellow/Green Red LED+ Black LEDRed Black AC-N AC-L FG +V Output -V Output DIM+ DIM- Input wire gauge #18 Output wire gauge #14 EN55015 / FCC Part 15, Class B EN61000-3-2, Class B EN61000-3-3 EN61000-4-2, 8kV Air, 4kV Contact, Level 3, Criteria A EN61000-4-3, Test-RS Level 3, Criteria A EN61000-4-4, Burst EFT Level 3, Criteria A EN61000-4-5, Line to Neutral 4kV, Line/Neutral to FG 6kV EN61000-4-6. Test-CS Level 3, Criteria A EN61000-4-8, Test 3A/m, Criteria A EN61000-4-11, Criteria B EN61547 Block diagram AC-L LED+ 1st LED AC LEDAC-N DIM+ R AC-N www.aimtec.com F 052.1e R3 LED LED Tel: +1 514 620 2722 2 of 6 DIM+ 10V 0-10V Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-Z up to 1700mA | AC-DC LED driver Dimensions Top View 320.0±20.0 12.60±0.79 7.4 5.0±1.0 30.3 0.29 0.20±0.04 4.0 1.19 0.16 35.0±2.0 1.38±0.08 163.0±1.5 6.42±0.06 320.0±20.0 12.60±0.79 159.0±1.0 6.26±0.04 30.0±2.0 1.18±0.08 10.0±1.0 0.39±0.04 68.7±1.0 2.70±0.04 7.4 0.29 4.0 0.16 4.0 0.16 12.7 0.50 150.0±0.5 5.91±0.02 175.4±1.0 6.91±0.04 12.7 0.50 Side View Yellow/Green 42.0±1.0 1.65±0.0 4 Blue Brown 150.0±0.5 5.91±0.02 175.4±1.0 6.91±0.04 Derating Graph Free Air Convection Safe Operating Area www.aimtec.com F 052.1e R3 Tel: +1 514 620 2722 3 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-Z up to 1700mA | AC-DC LED driver Case Temperature (TC ) vs. Life Time Case temperature vs Life time Lilfe time(Khours) 180 135 90 45 0 40 50 60 70 Case temperature (℃) 80 90 Efficiency Vs. Input Voltage & Output Voltage (Constant current mode) www.aimtec.com F 052.1e R3 Tel: +1 514 620 2722 4 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-Z up to 1700mA | AC-DC LED driver PF vs. Input Voltage & Output Voltage (constant current mode) Output Current vs. Output Voltage www.aimtec.com F 052.1e R3 Tel: +1 514 620 2722 5 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120C-Z up to 1700mA | AC-DC LED driver Output Current vs. Resistive / 0-10V Dimming Output Current vs.10V PWM Dimming Percentage of rated output current Output Current vs. 10V PWM Duty Cycle 115/230/277 VAC 120.00% 110.00% 100.00% 90.00% 80.00% 70.00% 60.00% 50.00% 40.00% 30.00% 20.00% 10.00% 0.00% 0 10 20 30 40 50 60 70 10V PWM Duty Cycle (%) 80 90 100 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3 Tel: +1 514 620 2722 6 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only