The ABC41 Series of ultra low open frame power supplies feature a wide universal AC input range of 85 V – 264 VAC, offering output power 40 W with natural convection cooling. They are available in a variety of isolated single output voltages. The ABC41 ultra low profile series is also available in a PCB mount format, facilitating simple embedded integration onto user’s main PCB assembly. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for broad range of telecom, datacom, industrial equipment and other applications. • 3 x 2 x 0.75 Inches Form factor • PCB Mount option available • 40 Watts Convection • Approved to EN/IEC 60950 • Efficiencies 85% Typical • -40 to 70 degree operating temperature • 2 million hours, Telcordia -SR332-issue 3 MTBF • Standby Power < 0.3 W • Instrumentation • Renewable Energy • Lighting • Test and Measurement • Industrial Applications • Robotics • Applied Computing • Wireless Communication ABC41 Series 2 ABC41-1T05L Screw Terminal ABC41-1005L Header ABC41-1005P PCB Mount ABC41-1T12L Screw Terminal ABC41-1012L Header ABC41-1012P PCB Mount ABC41-1T15L Screw Terminal ABC41-1015L Header ABC41-1015P PCB Mount ABC41-1T24L Screw Terminal ABC41-1024L Header ABC41-1024P PCB Mount ABC41-1T30L Screw Terminal ABC41-1030L Header ABC41-1030P PCB Mount ABC41-1T48L Screw Terminal ABC41-1048L Header ABC41-1048P PCB Mount ABC41-1T58L Screw Terminal ABC41-1058L Header ABC41-1058P PCB Mount COVER-41-XBC3 1 2 3 5V 5A 0.0 A 1.5% 12 V 3.33 A 0.0 A 1% 15 V 2.67 A 0.0 A 1% 24 V 1.67 A 0.0 A 1% 30 V 1.33 A 0.0 A 1% 48 V 0.83 A 0.0 A 1% 58 V 0.69 A 0.0 A 1% metal cover kit accessory For Class II Option (without input Earth pin) add suffix: -2 (e.g.: ABC41-1012L-2). Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. Output ripple can be more than 10% of the output voltage. When used in Cover Kit, de-rate output power to 70 % under all operating conditions. Cover Kit is not suited for PCB mount version. Specifications are for nominal input voltage, 25°C unless otherwise stated. Input Voltage Universal Input Frequency 85 - 264 VAC / 390 VDC 47 - 63 Hz Input Current 115 VAC: 230 VAC: 0.8 A max. 0.4 A max. No Load Power Typical < 0.3 W Inrush Current 115 VAC: 230 VAC: 264 VAC: 25 A 45 A 75 A Leakage Current Typical (N.A. For Class II Option- without input Earth pin) 300 µA Switching Frequency Typical 65 kHz [email protected] ABC41 Series 3 Output Power Convection cooling 40 W Efficiency Typical 85% Hold-up Time 230 VAC: 6 ms Line Regulation +/-0.5% Load Regulation +/-1% Transient Response 25% step load change, at 0.1 A/µs slew rate, 50% duty cycle, 50 Hz = 4% recovery time < 5 ms Rise Time Typical 50 ms Set Point Tolerance 2% (3% for 5 V model) Over Current Protection > 110% Over Voltage Protection Short Circuit Protection Operating Temperature 110 to 140% Hiccup mode Startup is guaranteed with spec. deviation, see Fig. 1 Storage Temperature -40 to +70°C -40 to 0°C -40 to +85°C Relative Humidity Non-condensing 5% to 95% Altitude Operating: Non-operating: 16,000 ft. 40,000 ft. MTBF Telcordia -SR332-issue 3 2 million hours Conducted Emissions EN55032-B, CISPR22-B, FCC PART15-B Pass Radiated Emissions EN 55032 A; with external core (King core K5B RC 25x12x15-M in input cable) Pass Level B Input Current Harmonics EN 61000-3-2 Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 3, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00891_AB Asia-Pacific +86 755 298 85888 ABC41 Series 4 Isolation Voltage Input to Output: Safety Standard(s) Approved to the latest edition of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1. Class1 SELV 4242 VDC Agency Approvals Nemko, UL, C-UL CE mark Complies with LVD Directive AC Input Connector J1 Screw Terminal / Header Pin 1 Pin 2 Pin 3 AC Line Not Fitted AC Neutral Tyco: 640445-3 Mating: 647402-3; Pins: 3-647409-1 DC Output Connector J2 Screw Terminal / Header Pin 1, 2 Pin 3, 4 V1 +VE V1 -VE Tyco: 640445-4 Mating: 647402-4; Pins: 3-647409-1 Weight approx. 100 g Dimensions 76.2 x 50.8 x 19.05 mm (3 x 2 x 0.75 inches) (Header) % Figure 1. Derating Curve for all Outputs De-rate linearly from 100% at 50°C to 50% at 70°C [email protected] ABC41 Series 5 Mechanical Drawing – Options with Header and Screw Terminal Mechanical Drawing – PCB Mount Option NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 Stand off, used to mount PCB has OD of 5.4 mm max. 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3 Washer, if used, to have dia of 6.5 mm max. NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00891_AB Asia-Pacific +86 755 298 85888