The MBC75 Series of open frame medical power supplies feature a wide universal AC input range of 85 V – 264 VAC, offering 75 W of output power in a compact 3 x 2 x 1 inch footprint, with a variety of isolated single output voltages. 3 x 2 x 1 Inch Form Factor 75 Watts with Convection Cooling Approval to EN60601 3rd Edition Efficiencies 93% -40 To 70 Degree Operating Temperature Dual Fusing Thermal Shut-Down Feature >3.00 Million Hours, Telcordia -SR332-Issue 3 Standby Power < 0.3W Class II Option Available RoHS Compliant CE Marked The MBC series was designed to 3rd edition medical approvals and provides 2x MOPP (Means of Patient Protection) isolation for Class I and Class II installations. These power supplies are ideal for medical, telecom, Datacom, industrial equipment and other applications. Diagnostic Drug Pump Dialysis Home Health Care Monitoring Portable Equipment North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00665_001 MBC75 Series MODEL NUMBER 2 DESCRIPTION MBC75-1T12L MBC75-1012L MBC75-1T15L MBC75-1015L MBC75-1T24L MBC75-1024L MBC75-1T30L MBC75-1030L MBC75-1T48L MBC75-1048L MBC75-1T58L MBC75-1058L Screw Terminal Molex Header Screw Terminal Molex Header Screw Terminal Molex Header Screw Terminal Molex Header Screw Terminal Molex Header Screw Terminal Molex Header VOLTAGE MAX. LOAD (CONVECTION) MIN. LOAD RIPPLE & NOISE 1 12 V 6.25 A 0.0 A 1% 15 V 5.00 A 0.0 A 1% 24 V 3.12 A 0.0 A 1% 30 V 2.50 A 0.0 A 1% 48 V 1.56 A 0.0 A 1% 58 V 1.29 A 0.0 A 1% COVER-75-XBC 1 2 metal cover kit accessory Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. For Class II (without input Earth pin) add suffix -2 (e.g.: MBC75-1012L-2). 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00665_001 MBC75 Series Specifications are for nominal input voltage, 25°C unless otherwise stated. PARAMETER Input Voltage DESCRIPTION / CONDITION Universal (Derate from 75 W at 10 0VAC to 65 W at 85 VAC) Input Frequency SPECIFICATION 85-264 VAC / 390 VDC3 Power Factor 115 VAC: 230 VAC: Typical 115 VAC: 230 VAC: 264 VAC: Typical (N.A. For Class II Option) Touch current @ Full Load 47-63 Hz 1 A max. 0.5 A max. < 0.3 W 25 A 45 A 75 A 300 uA <100 uA > 0.95 Switching Frequency Typical 60 kHz PARAMETER DESCRIPTION / CONDITION SPECIFICATION Output Power Convection: 48 V, 58 V: 24 V, 30 V: 12 V, 15 V: Typical 75 W 93% 91% 90% >16 ms Input Current No Load Power Inrush Current Leakage Current 3 Functional, not approved. Efficiency Hold-up Time Line Regulation +/-0.5% Load Regulation Transient Response +/-1% 25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50 Hz = 4% Voltage Adjustment Rise Time Typical 55 ms Set Point Tolerance +/-1% Over Current Protection > 110% Over Voltage Protection Latch type (AC recycling required) Short Circuit Protection Hiccup mode PARAMETER DESCRIPTION / CONDITION Operating Temperature recovery time < 5 ms +/-3% 110 to 140% Startup is guaranteed with spec deviation, see Fig 1. Storage Temperature SPECIFICATION -40 to +70°C -40 to 0°C -40 to +85°C Cooling With natural convection cooling at 100 to 264 VAC 75 W Relative Humidity Noncondensing Operating: Nonoperating: MTBF according to Telcordia -SR332-Issue 3 5% to 95% 16,000 ft 40,000 ft. 3.00 million hours Altitude Reliability 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00665_001 MBC75 Series PARAMETER DESCRIPTION / CONDITION Conducted Emissions EN55022-B, CISPR22-B, FCC PART15 - B Static Discharge EN61000-4-2: Level-3 RF Field Susceptibility EN61000-4-3: Level-3 Fast Transients/Bursts Level-3 Level A Level B Surge Susceptibility EN61000-4-4: Radiated: Radiated with external core: (King core K5B RC 25x12x15-M in input cable with 5 Turns) EN61000-4-5: Harmonic Current EN61000-3-2: Class D PARAMETER SPECIFICATION 4000 VAC 1500 VAC 1500 VAC 500 VAC Agency Approvals DESCRIPTION / CONDITION Input to Output: (For medical applications) Input to GND: (Not Applicable For Class II Option) Output to GND: for type BF for type B (N/A For Class II Option) Approved to the latest edition of the following standards: CSA/UL60601-1, EN60601-1 and IEC60601-1. Nemko, UL, C-UL CE mark Complies with LVD Directive Radiated Emissions Isolation Voltage Safety Standard(s) SPECIFICATION Level-3 Figure 1 – Derating Curve CONNECTOR PIN AC Input Connector J1 DC Output Connector J2 DESCRIPTION / CONDITION Pin 1 Pin 2 Pin 3 AC Line Not Fitted AC Neutral Pin 1, 2 Pin 3, 4 V1 -VE V1 + VE Screw Terminal (Option 1) Molex Connector (Option 2) Screw Terminal (Option 1) Molex Connector (Option 2) MANUFACTURER / PN Molex: 39357-0003 Tyco: 2-1776112-3 Molex: 1722861103 (Mating conn: Molex 1722561003) Molex: 39357 -0004 Tyco: 2-1776112-4 Molex: 1722861104 (Mating conn: Molex 1722561004) 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00665_001 MBC75 Series PARAMETER DESCRIPTION / CONDITION Weight 150 g Dimensions 76.2 x 50.8 x 25.4 mm (3 x 2 x 1 inch) Figure 2 - Mechanical Drawing - Screw Terminal (Option 1) 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00665_001 MBC75 Series Figure 3 - Mechanical Drawing - Molex Connector (Option 2) NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00665_001