CREE CR14-31L-50K-S Cr14 architectural led troffer Datasheet

CR Series
CR14™ 1' x 4' Architectural LED Troffer
Product Description
The CR14™ Architectural LED troffer delivers up to 130 lumens per watt of exceptional 90 CRI light at
4000 lumens. This breakthrough performance is achieved by combining the high efficacy and highquality light of Cree TrueWhite® Technology with a unique thermal management design. The CR14
product family is available in warm, neutral, cool, or daylight color temperatures and has step, 0-10V,
or Lutron EcoSystem® Enabled dimming options. Its unique indirect illumination design makes the
CR14 perfect for use in commercial new construction or renovated spaces.
Performance Summary
Utilizes Cree TrueWhite® Technology (90 CRI)
Room-Side Heat Sink
Efficacy: 90-130 LPW
Initial Delivered Lumens: 2,200, 3,100, 4,000, 5,000 lumens
Input Power: 22-50 watts
CRI: 90 CRI (Cree TrueWhite® Technology), 80+ CRI (HD)
CCT: 3000K, 3500K, 4000K, 5000K
Input Voltage: 120-277 VAC or 347 VAC
47.7"
(1212mm)
Limited Warranty†: 10 years
Lifetime: Designed to last from 50,000 hours (HD), 75,000 hours (Standard TW), and
100,000 hours (HE TW)
Controls: Step Level to 50%, 0-10V Dimming , Lutron EcoSystem Enabled to 5%*
Mounting: Recessed**
See www.cree.com/lighting/products/warranty for warranty terms
* Reference www.cree.com/lighting for recommended dimming control options
** Acceptable for use with standard 9/16 T-Bar or larger when installed per installation instructions. Consult factory for non-standard grid applications
†
11.7"
(297mm)
4.5"
(114mm)
Accessories
Field-Installed
Adjustable Cable
AC5- 72 PD8 JB
AC5 18/4 72 PD8 JB
Chicago Plenum Field Kit
CPLCR
Chicago Plenum Field Kit-Emergency
CPLCR EM
Junction Box
EJBCR 5PK
- Expanded size junction box for through wiring (5 pack)
NOTE: Use of Expanded Junction Box will expand the depth to 6.42" and
Emergency Backup will expand the depth to 6.05". Use of 347V will increase
luminaire height by 1.4"
Power Whip
PW 18/4 06 9T/SS CR
347 Volt
CR 347V
Step Dimming to 50%
CR 347V SD
Surface Mount Kit
SMK 14
Ordering Information
Example: CR14-40L-35K-S
CR14
Product
Initial Delivered Lumens
CCT
Voltage
Control
Options
CR14
22L
22W, 2200 lumens – 100 LPW
- Only available in 35K or 40K
31L1
34W 3100 lumens – 90 LPW
40L
40W 4000 lumens – 100 LPW
40LHE1
30.5W 4000 lumens – 130 LPW (30K)
32W 4000 lumens – 125 LPW (35K)
33W 4000 lumens – 120 LPW (40K)
34.5W 4000 lumens – 115 LPW (50K)
50L2
50W 5000 lumens – 100 LPW
30K
3000K
35K
3500K
40K
4000K
50K
5000K
Blank
120-277 Volt
34V
347 Volt
- Integrated option available on 40L only.
Other types require addition of a 347
accessory kit (see table above)
S
Step Dimming to 50%
10V
0-10V Dimming to 5%
LES3
Lutron EcoSystem® Enabled to 5%
HD
1
1. Not available with HD 2. Not available with HD, EB14, EB14SMK
NOTE: Price adder may apply depending on configuration
3. Not available in the following options: 22L: 30K or 50K; 31L: All Colors; 40LHE: All Colors
4. Not available in 50L
EB14
4,5
CRI 80+ (44W 4000 lumens – 90 LPW)
- Available only with 40L
Emergency Backup – 1400 lumens
- Not for use with SMK Kits. Use EB14 SMK
EB14SMK4,5
Emergency Backup with surface mount kit – 1400 lumens
- Includes surface mount kit accessory
(SMK-CR14)
5. Not available in LES types except 40L LES type
Rev. Date: V5 10/28/2015
US: www.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
CR14™ 1' x 4' Architectural LED Troffer
Product Specifications
Recommended CR Series Lumen Maintenance Factors (LMF)1
CREE TRUEWHITE® TECHNOLOGY
A revolutionary way to generate high-quality white light, Cree TrueWhite® Technology is
a patented approach that delivers an exclusive combination of 90+ CRI, beautiful light
characteristics, and lifelong color consistency, all while maintaining high luminous
efficacy – a true no compromise solution
Ambient
0˚C
(41˚F)
CREE LED TECHNOLOGY
Cree's total systems approach to product development is a comprehensive engineering
philosophy that combines the most advanced LED sources, driver technologies, optics
and forms. The result is highly-reliable luminaire solutions for both indoor and outdoor
applications that reduce energy use, extend lifetimes, and maximize illumination
performance and quality.
5˚C
(41˚F)
10˚C
(50˚F)
ROOM-SIDE HEAT SINK
An innovative thermal management system designed to maximize cooling effectiveness
by integrating a unique room-side heat sink into the diffusing lens. This breakthrough
design creates a pleasing architectural aesthetic while conducting heat away from LEDs
in a temperature-controlled environment. This enables the LEDs to consistently run
cooler, providing significant boosts to lifetime, efficacy, and color consistency.
15˚C
(59˚F)
20˚C
(68˚F)
CONSTRUCTION & MATERIALS
• Durable 22-gauge steel housing with standard troffer access plate for electrical
installation
25˚C
(77˚F)
• One-piece lower reflector finished with a textured high reflectance white polyester
powder coating creates a comfortable visual transition from the lens to the ceiling
plane
30˚C
(86˚F)
• Includes t-bar clips and holes for mounting support wires enable recessed or
suspended installation
35˚C
(95˚F)
• Individual luminaires may be mounted end to end for a continuous row of illumination
OPTICAL SYSTEM
• Unique combination of reflective and refractive optical components achieves a
uniform, comfortable appearance while eliminating pixelation and color fringing
• Components work together to optimize distribution, balancing the delivery of high
illuminance levels on horizontal surfaces with an ideal amount of light on walls and
vertical surfaces. This increases the perception of spaciousness
• Diffusing lens integrated with upward-facing LED strip eliminates direct view of LEDs
while lower reflector balances brightness of lens with the ceiling to create a low-glare
high angle appearance
40˚C
(104˚F)
Initial Delivered
Lumens
Initial
LMF
25K hr
Projected2
LMF
50K hr
Projected2
LMF
75K hr
Calculated3
LMF
100K hr
Calculated3
LMF
22L, 31L, 40L, and 50L
1.05
1.04
1.04
1.04
1.04
40LHE
1.05
1.01
0.98
0.96
0.94
22L, 31L, 40L, and 50L
1.04
1.03
1.03
1.03
1.03
40LHE
1.04
1.00
0.97
0.95
0.93
22L, 31L, 40L, and 50L
1.03
1.02
1.02
1.02
1.02
40LHE
1.03
0.99
0.96
0.94
0.92
22L, 31L, 40L, and 50L
1.02
1.01
1.01
1.01
1.01
40LHE
1.02
0.98
0.95
0.93
0.91
22L, 31L, 40L, and 50L
1.01
1.00
1.00
1.00
1.00
40LHE
1.01
0.97
0.95
0.92
0.90
22L, 31L, 40L, and 50L
1.00
0.99
0.99
0.99
0.99
40LHE
1.00
0.96
0.94
0.91
0.89
22L, 31L, 40L, and 50L
0.99
0.98
0.98
0.98
0.98
40LHE
0.99
0.95
0.93
0.91
0.89
22L, 31L, 40L, and 50L
0.98
0.97
0.97
0.97
0.97
40LHE
0.98
0.94
0.92
0.90
0.88
22L, 31L, 40L, and 50L
0.97
0.96
0.96
0.96
0.96
40LHE
0.97
0.93
0.91
0.89
0.87
Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ luminaire testing
In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times
(6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)
3
In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM-80-08 total
test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)
1
2
ELECTRICAL SYSTEM
• Integral, high-efficiency driver
• Power Factor: = 0.9 nominal
• Input Power: Stays constant over life
• Input Voltage: 120-277V or 347V, 50/60Hz
• Operating Temperature Range: 0˚C - + 35˚C (32˚F - + 95˚F)
• Total Harmonic Distortion: < 20%
CONTROLS
• Step dimming to 50%*
• Continuous dimming to 5% with 0-10V DC control protocol*
• Lutron EcoSystem® Enabled option allows seamless integration with Lutron
EcoSystem controls*
REGULATORY & VOLUNTARY QUALIFICATIONS
• cULus Listed
• Suitable for damp locations
• Designed for indoor use
• UL924 (EB14 option)
• DLC qualified. Please refer to www.designlights.org/QPL for most current information
• RoHS compliant. Consult factory for additional details
• Meets FCC Part 15 standards for conducted and radiated emissions
* Reference www.cree.com/lighting for recommended dimming controls and wiring diagrams
US: www.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
CR14™ 1' x 4' Architectural LED Troffer
Photometry
CR14-40L-30K BASED ON LTL REPORT TEST #: 24294
Luminaire photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM-79-08. IESNA LM-79-08 specifies the entire luminaire as the source
resulting in a luminaire efficiency of 100%.
250
75
500
60
750
45
1000
1250
1500
15
0
30
0°
90°
Coefficients Of Utilization – Zonal Cavity
Method
Zonal Lumen Summary
Average Luminance Table (cd/m2)
Horizontal Angle
RC %:
80
RW %:
70
50
30
10
RCR: 0
119
119
119
119
1
110
106
102
73
2
101
93
87
82
3
92
82
75
69
4
85
74
65
59
5
78
66
57
51
6
72
60
51
45
7
67
54
46
40
8
63
49
41
36
9
58
45
37
32
10
55
42
34
29
Vertical Angle
90
Zone
Lumens
% Lamp
Luminaire
0°
45°
90°
0-30
1,220
N/A
30.8%
45°
5,407
5,407
5,407
0-40
1,995
N/A
50.4%
55°
5,015
5,002
4,673
0-60
3,385
N/A
85.5%
65°
4,589
4,315
3,572
0-90
3,959
N/A
100%
75°
3,039
1,690
1,282
0-180
3,959
N/A
100%
85°
1,727
1,249
1,321
Effective Floor Cavity Reflectance: 20%
Reference www.cree.com/Lighting/Products/Indoor/Troffers/CR-Series for detailed photometric data
Application Reference
Based on CR14-40L-30K Luminaire
Open Space
Spacing
8x8
8 x 10
10 x 10
10 x 12
Lumens
Wattage
LPW
w/ft2
Average fc
2200L
22W
100
0.35
30
4000L
40W
100
0.69
54
4000L
30.5W
125
0.56
54
5000L
50W
100
0.78
68
2200L
22W
100
0.28
25
4000L
40W
100
0.55
45
4000L
30.5W
125
0.45
45
5000L
50W
100
0.62
57
2200L
22W
100
0.22
21
4000L
40W
100
0.44
38
4000L
30.5W
125
0.36
38
5000L
50W
100
0.50
48
2200L
22W
100
0.19
17
4000L
40W
100
0.37
30
4000L
30.5W
125
0.30
30
5000L
50W
100
0.42
38
9' ceiling: 80/50/20 reflectances; 2.5' workplane, open room. LLF: 1.0 Initial Open Space: 50' x 40' x 10'
© 2015 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change.
Patent www.cree.com/patents. Cree®, TrueWhite®, and Cree TrueWhite® are registered trademarks, and the Cree logo, the Cree
TrueWhite Technology logo, and CR14™ are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC. Lutron®, Lutron
EcoSystem®, EcoSystem®, and the Lutron EcoSystem Enabled logo are registered trademarks of Lutron, Inc. The DLC QPL logo is a
registered trademark of Northeast Energy Efficiency Partnerships, Inc.
US: www.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
Similar pages