Power Transformer PC Mount: Flat Pack ™ FP230-50 Electrical Specifications (@25C) 1. Maximum Power: 12.0 VA 2. Primary Voltage: Series: 230V@50/60 Hz Parallel: 115V@50/60Hz 3. Secondary: Series: 230.0VCT @ 0.050Amps Parallel: 120.0V @ 0.100Amps Description: The FP230-50 is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials. Construction: Wound on two dual channel nylon bobbin. Materials are UL recognized, Class B (130º C) rated. 7 8 6 5 3 4 2 1 Safety: These products are 100% hipot tested with an insulation of 2000V between primary and secondary windings and 1500V between the primary / secondary windings and the core. A Agency File: UL: File E53148, UL 506, Class B General Purpose Transformer, cUL: File E53148, UL 506, Class B General Purpose Transformer, Canadian Use B C Dimensions: A B C D E F 2.500 2.00 1.062 0.267 0.500 2.00 D Units: In inches Weight: 11.0 oz Pin Dimension: .020 x .041 in Schematic: F 1 5 2 6 4 8 3 7 .060 DIA HOLES E E E RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: December 4, 2013