Bel LDC480-72P Active pfc Datasheet

LDC480 Series is a single phase, extremely compact Power Supply
with active PFC specially designed for space sensitive and demanding
applications.
Its compact size, high efficiency, excellent reliability together with easy
installation makes it ideal for various industrial applications.
LDC480 Series is Class I isolation device suitable for SELV and PELV
circuitry (up to 48 VDC models) and is designed to be mounted on DIN
rail and installed inside a protective enclosure.

High efficiency and extremely compact size

Only 56 mm width aluminum enclosure

Active PFC

Overload 150%

Constant current or hiccup mode limitation, user settable

Wide range of output voltage

Easy parallelable for power increase

Up to 60°C operating temperature with no derating

Industrial Control

Communication

Instrumentation Equipment

Renewable energy

High reliability applications
LDC480 Series
2
LDC480-24
120 - 240 VAC (110 - 345 VDC)
24 VDC
20 A
LDC480-24P
120 - 240 VAC (110 - 345 VDC)
24 VDC
20 A
LDC480-36
120 - 240 VAC (110 - 345 VDC)
36 VDC
15 A
LDC480-36P
120 - 240 VAC (110 - 345 VDC)
36 VDC
15 A
LDC480-48
120 - 240 VAC (110 - 345 VDC)
48 VDC
10 A
LDC480-48P
120 - 240 VAC (110 - 345 VDC)
48 VDC
10 A
LDC480-72
120 - 240 VAC (110 - 345 VDC)
72 VDC
6.7 A
LDC480-72P
120 - 240 VAC (110 - 345 VDC)
72 VDC
6.7 A
Includes internal ORing diode
Includes internal ORing diode
Includes internal ORing diode
Includes internal ORing diode
Technical parameters are typical, measured in laboratory environment at 25°C and 240 VAC / 50 Hz, at nominal values, after minimum
5 minutes of operation.
Input AC Voltage Range
Rated, UL certified
Operating
120 – 240 VAC
90 - 264 VAC
Input DC Voltage Range
Rated
110 - 345 VDC
Input Frequency Range
47 - 63 Hz
Vin = 120 VAC
Vin = 230 VAC
Vin = 110 VDC
Vin = 345 VDC
Input AC Current
Input DC Current
Power Factor Correction
Active
4.8 A
2.4 A
4.9 A
1.7 A
> 0.9
Inrush Peak Current
≤ 35 A
Touch (Leakage) Current
≤ 0.9 mA
Internal Protection Fuse
Not user replaceable
8 AT
Recommended External Protection
It is strongly recommended to provide external surge
arresters (SPD) according to local regulations.
Fuse 10 AT or MCB 10 A C curve
Output Power
Rated Voltage
(Adjustable Output Voltage Range)
Continuous Current
Overload Limit (Constant Current Mode)
Overload Limit (Hiccup mode) (max. 5 s)
LDC480-24
LDC480-36
LDC480-48
LDC480-72
LDC480-24
LDC480-36
LDC480-48
LDC480-72
LDC480-24
LDC480-36
LDC480-48
LDC480-72
LDC480-24
LDC480-36
LDC480-48
LDC480-72
480 W
24 VDC (22 - 29 VDC)
36 VDC (34 - 39 VDC)
48 VDC (45 - 55 VDC)
72 VDC (70 - 85 VDC)
20 A
15 A
10 A
6.7 A
21 A
16 A
12 A
7A
30 A
20 A
17 A
12 A
[email protected]
LDC480 Series
Ripple & Noise1
Hold up Time
Protections
Output Over Voltage Protection
Status Signals
Parallel Connection2
Efficiency
Dissipated Power
2
≤ 1.5%
≤ 0.5%
≤ 150 mVpp
≤ 50 mVpp
≥ 25 ms
Overload, short circuit, with constant current or hiccup mode (user settable)
Thermal protection
Input undervoltage lockout
Output overvoltage
LDC480-24
≥ 33 VDC
LDC480-36
≥ 45 VDC
≥ 68 VDC
LDC480-48
≥ 100 VDC
LDC480-72
DC OK - green LED
OVERLOAD - red LED
DC OK - dry contact (NO, 24 VDC / 1 A)
Possible for power or redundancy (with external ORing module)
P (models) - include internal ORing circuit
LDC480-24 / LDC480-36
> 93%
LDC480-48 / LDC480-72
> 94%
LDC480-24 / LDC480-36
< 36.5 W
LDC480-48 / LDC480-72
< 31 W
LDC480-24 / LDC480-36
LDC480-48 / LDC480-72
LDC480-24 / LDC480-36
LDC480-48 / LDC480-72
Load Regulation
1
3
Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1μF MKP parallel capacitor.
Pay attention, set the current limitation mode jumper on C.C. mode when connecting more units in parallel.
NOTE: Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range.
Contact factory for details.
UL certified up to 50°C at 120 VAC or
up to 60°C at 240 VAC (Start-up type tested: - 40°C)3
Operating Temperature
Storage Temperature
- 40° to + 80°C
- 7.6 W / °C over 50°C at 120 VAC
- 7.2 W / °C over 60°C at 240 VAC
5 - 95% RH
Derating
Humidity
Non condensing
Life Time Expectancy
Overvoltage Category
Pollution Degree
Protection Class
At 25°C ambient, full load
Protection Degree
Input to Output
Input to Ground
Output to Ground
UL508 (certified)
EN60950 (reference)
EN50178 (reference)
EN55011 (CISPR11)
EN55022 (CISPR22)
EN61000-3-2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-11
EN60529
Vibration Sinusoidal
IEC 60068-2-6
Shock
IEC 60068-2-27
Isolation Voltage
Safety Standards & Approvals
Emission
EMC Standards
Immunity
3
- 40° to + 70°C
167953 h (19.1 years)
III (EN50178)
2 (IEC60664-1)
Class I
4.2 kVDC
2.2 kVDC
0.75 kVDC
Class B
Class B
Class A
Level 3
Level 3
Level 3
Level 4
Level 2
IP20
5-17.8 Hz: ±1.6 mm;
17.8-500 Hz: 2 g 2Hours / axis (X,Y,Z)
30 g 6 ms, 20 g 11 ms; 3 bumps / direction,
18 bumps total
Possible with load derating.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00757_AB
Asia-Pacific
+86 755 298 85888
LDC480 Series
4
Weight
1.1 kg
Dimensions (W x H x D)
56 x 140 x 117 mm
Mounting Rail
IEC 60715/H15/TH35-7.5(-15)
Connection Terminals
Screw type pluggable (24 - 12 AWG)
Case Material
Aluminum
1
AC/DC input
2
4
DC output (load)
Diagnostic Output
(dry contact, NC output OK)
Green LED: Output OK
5
Red LED: Overload
6
Output voltage adjustment
Selectable limitation mode
(Hiccup mode, C.C. mode)
3
7
2.5 mm²
INPUT CONNECTION
Single phase:
L = Line
N = Neutral
= Earth ground
DC:
L = + Positive DC
N = - Negative DC
= Earth ground
OUTPUT CONNECTION
+ = Positive DC
- = Negative DC
Signaling:
DC OK: dry contact
NO
COM
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
[email protected]