Click on Series name for product info on aimtec.com Series AME10-JZ 10 Watt | AC-DC / DC-DC Converter FEATURES: I/O Isolation 3000VAC Operating Temp: -40°C to +70°C Over current Protection Input: 85-305VAC, 47-63Hz, or 100-430VDC Low Ripple and Noise Over Voltage Protection Up to 82% efficiency Short Circuit Protection Models Single output Input Voltage (VAC/Hz) Input Voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum capacitive load (µF) 85-305/47-63 85-305/47-63 85-305/47-63 85-305/47-63 85-305/47-63 85-305/47-63 100-430 100-430 100-430 100-430 100-430 100-430 6.6 10 10 10 10 10 3.3 5 9 12 15 24 2 2 1.1 0.9 0.7 0.45 26000 9400 3600 2400 1200 370 Model AME10-3.3SJZ AME10-5SJZ AME10-9SJZ AME10-12SJZ AME10-15SJZ AME10-24SJZ Efficiency (%) 230 VAC 70 76 78 80 81 82 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC Recommended slow blow type 10 15 2 Conditions Typical (LL-HL) 10-100% load ±2 ±0.5 ±1 115 VAC 230 VAC 15 80 Conditions Typical Maximum Units 260 160 mA mA A A mA A 0.25 Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise Hold-up time Maximum Units % % % mV p-p ms ms 100 Isolation Specifications Parameters Tested I/O voltage Input to Output, 60 sec Input to Ground Isolation resistance Rated Units 3000 2000 VAC >1000 MΩ General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient www.aimtec.com F 052e R8.A Conditions Typical Maximum 100 ≥110 Zener Diode Clamp Auto recovery -40 to +70 See derating curve KHz % of Iout 100 -40 to +105 ±0.02 Tel: +1 514 620 2722 1 of 3 Units °C °C °C % / °C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME10-JZ 10 Watt | AC-DC / DC-DC Converter General Specifications (continued) Parameters Conditions Typical Maximum Units Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 75 g Dimensions (L x W x H) 55.0 x 45.0 x 21.0 mm (2.17 x 1.77 x 0.83 inches) MTBF > 300 000 hrs (MIL-HDBK -217F, t=+25oC)/ Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals CE, UL Information Technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC/EN/UL 60950-1 EN55022, class B EN55024: 2010 IEC 61000-4-2: Contact ±6KV/Air ±8KV, Criteria B IEC 61000-4-3: 10V/m, Criteria A IEC 61000-4-4: ±2KV, Criteria B IEC 61000-4-5: ±1KV/±2KV, Criteria B IEC 61000-4-6: 10Vrms, Criteria A IEC 61000-4-8: 10A/m, Criteria A IEC 61000-4-11: 0-70%, Criteria B Typical Application circuit Single Output FUSE 3.15A/300V + Vout AC L AC L MOV S14K350 AC N AC DC AC N + Vout + C2 C1 1µF/50V ‐ Vout Earth/GND TVS ‐ Vout Vout C2 TVS 3.3V 5V 9V 12 & 15V 24V 470 µF/50V 330 µF/50V 120 µF/50V 120 µF/50V 68 µF/50V 7A 7A 12A 20A 30A Pin Out Specifications Pin Single 1 2 3 4 5 Earth/Ground AC Input (L) AC Input (N) - V output + V output www.aimtec.com F 052e R8.A Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME10-JZ 10 Watt | AC-DC / DC-DC Converter 5.00 (0.20) Dimensions 12.50 (0.49) 55.00 (2.17) 2 Bottom View 1 5 20.00 (0.79) 45.00 (1.77) 17.50 (0.69) 3 Top View 2 4 4 5 3 1 47.00 (1.85) 4.00 (0.16) DIV: 10.00 (0.40) 21.00 (0.83) Ø 1.50 (Ø 0.06) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) 6.00 (0.24) 1.00 (0.04) Derating Free Air Convection Free Air Convection at 25°C 80 60 100 Output Power (%) Output Power (%) 100 Safe Operating Area 100% load 100-277VAC Or 120-390VDC 40 80 75 Safe Operating Area 40 20 20 0 - 40 60 - 20 -10 0 20 40 55 70 80 60 0 85 100 (100) (120) 100 277 (390) 305 (430) Input Voltage VAC (VDC) Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.A Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only