Click on Series name for product info on aimtec.com Series AME2-AZ 2Watt | AC-DC Converter FEATURES: • • • • • Models Single output I/O Isolation 3000VAC Operating Temp: -40°C to +70°C Input: 90-305VAC, 47-440Hz, or 130-430 VDC Optional 90-528VAC, 47-440Hz, or 130-745 VDC Over load, Short Circuit Protection • RoHS compliant • Energy Star compliant • Ultra small package Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (ºC) Output Voltage (V) Output Current max (mA) AME2-3.3SAZ AME2-5SAZ AME2-12SAZ AME2-15SAZ AME2-24SAZ 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 130-430 130-430 130-430 130-430 130-430 -40 to +70 -40 to +70 -40 to +70 -40 to +70 -40 to +70 3.3 5 12 15 24 600 400 166 133 83 AME2-3.3SBAZ AME2-5SBAZ AME2-12SBAZ AME2-15SBAZ AME2-24SBAZ 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 130-745 130-745 130-745 130-745 130-745 -40 to +70 -40 to +70 -40 to +70 -40 to +70 -40 to +70 3.3 5 12 15 24 600 400 166 133 83 Model Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Input Dissipation (No Load) Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Transient Recovery Time Transient Response Deviation Minimum load Conditions Typical Recommended slow blow type 1 ≦0.5 115 VAC 230 VAC 277 VAC 480VAC 115 VAC 230 VAC 277 VAC 480 VAC Maximum capacitive Load (µF) 115 230 277 2200 1100 680 560 470 64 67 75 78 81 63 66 72 74 81 61 63 69 71 79 2200 1100 680 560 470 57 63 68 68 67 57 63 68 67 67 56 62 66 66 65 Tested I/O voltage Isolation Resistance General Specifications Parameters Switching frequency Over Load protection Short circuit protection Operating temperature www.aimtec.com F 052e R8.B VAC Maximum 40 20 20 15 10 15 20 30 0.15 VAC 480 VAC VAC 50 56 53 57 58 Units mA mA mA mA A A A A mA A W Conditions Typical Maximum Conditions Typical Rated Units Maximum Units ±5 ±1.5 ±5 200 25% load step ±2 0 3.3/5 VAC With 560µF E/C 200 Ripple & Noise 12/15 VAC With 220µF E/C 400 24 VAC With 220µF E/C 500 *Ripple & Noisemeasured at 20MHz bandwidth with 0.1µFand 115/230/277/480 VAC( Typical input ) with Full Load Isolation Specifications Parameters Efficiency (%) Full load (typical)* LL-HL, Full Load 0-100% load (typical)* 60 sec 3000 >1000 Conditions Typical 100 >125% Auto recovery Auto recovery Without derating Tel: +1 514 620 2722 1 of 3 -40 to +70 Units % % % µs % of Vout % mV p-p mV p-p mV p-p VAC MΩ KHz o C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME2-AZ 2Watt | AC-DC Converter General Specifications (continued) Parameters Conditions Typical Maximum Units o Storage temperature -40 to +85 C o Maximum Case temperature 100 C Humidity Non condensing 20 ~ 95 % RH Case material Plastic resin + Fiberglass (flammability to UL 94V-0) Weight 25 g Dimensions (L x W x H) 1.327 x 0.874 x 0.71 (33.70 x 22.20 x 18.00mm) o MTBF > 400 000 hrs (MIL-HDBK -217F, t=+25 C) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Shock Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Vibrations Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Derating cULus, CE, CB (pending), CSA Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity (1KV) RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Canadian Safety Agency IEC/EN/UL 60950-1:2006+A11:2009 EN55022, class B IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1) IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 CAN/CSA-C22.2 NO. 60950-1-07 Free Air Convection 70 ºC Output Power % 100 80 60 Safe Operating Area 40 20 70 0 -40 -20 0 20 40 60 80 100 Ambient Temperature º C www.aimtec.com F 052e R8.B Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME2-AZ 2Watt | AC-DC Converter Pin Out Specifications Pin Single 1 2 3 4 AC Input (N) AC Input (L) -V Output +V Output Dimensions NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.B Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only