Artesyn LCB100W 100 watt single output power supply Datasheet

POWER
LCB100
100 Watt Single Output Power Supply
Data Sheet
Total Power: 100 W
# of Outputs: Single
Outputs:
3.3 - 48 V
SPECIAL FEATURES
ƒƒ No-load power consumption 0.5 W
ƒƒ Low cost
ƒƒ 5.1” x 3.9” x 1.5”
ƒƒ 10% output voltage adjust
ƒƒ -25 °C to 70 °C with derating
ƒƒ High efficiency: 90% @ 230 Vac
ƒƒ Power ON with LED indicator
ƒƒ Withstand 5G vibration test
ƒƒ Two year warranty
COMPLIANCE
ƒƒ EMI Class B
ƒƒ EN61000, EN61204-3
SAFETY
ƒƒ UL, cUL
ƒƒ TUV
ƒƒ CE
60950-1
60950-1
Electrical Specifications
Input
Input ra­nge
88 - 264 Vac
125 - 373 Vdc
Frequency
47 - 63 Hz, Nominal 50/60
Inrush current
40 A, cold start at 25 °C, 230 Vac
Harmonics
EN61000-3-2: 2000 Class A,
EN61000-3-3: 1995+A1:2001
Input current
2.5 A / 115 Vac
Hold up time
>32 ms / 230 Vac
>10 ms / 115 Vac at full load
Efficiency
89% typical at full Load / 230 Vac nominal
Leakage current
< 2 mA at 264 Vac
Isolation
Isolation: PRI-Chassis 1500 Vac
PRI-SEC 3000 Vac
SEC-Chassis 500 Vac
LCB100 Data Sheet
Electrical Specifications
Output
Output rating
See ordering information
90 - 264 Vac
Output tolerance
± 1% to 3%
90 - 264 Vac
Total regulation range
± 0.5% to 3%
Combined line/load/transient when measured at output terminal
Rated load
66 - 110 W
Derate linear to 50% from 50 °C to 70 °C
Output noise (PARD)
150 - 200 mV p-p
Main output
Measured with a 0.1 μF Ceramic and 10 μF Tantalum Capacitor on any output, 20 MHz
Output voltage overshoot
Short circuit protection
No overshoot/undershoot outside the regulation band during on or off cycle
Protected, no damage to occur
Bounce mode
Output isolation
Standard per safety requirements
Overload protection (OCP)
>110% rated output power
Main output
Overvoltage protection (OVP)
115% to 150%
Main output
Output voltage adjust
± 10%
Main output
Environmental Specifications
Operating temperature
-25 °C to +70 °C, linear derating to 50% from 50 °C to 70 °C
Storage temperature
-40 °C to +85 °C
Humidity
20 to 90%, non-condensing.
Vibration
10 - 500 Hz, 5G 10 min/1 cycle, period for 60 min each along X, Y, Z axes
Ordering Information
Output Voltage
Output Current
Vo Adjust
Output Power
Efficiency
LCB100D
Model Number
3.3 V
20 A
± 10%
66 W
79%
LCB100E
5V
16 A
± 10%
80 W
83%
LCB100L
12 V
8.5 A
± 10%
102 W
86%
LCB100N
15 V
7A
± 10%
105 W
88%
LCB100Q
24 V
4.5 A
± 10%
108 W
88%
LCB100W
48 V
2.3 A
± 10%
110 W
89%
Miscellaneous Specifications
BURN-IN
100% Burn-in at 45 °C, at full load. Duration of burn-in determined by Quality Assurance Procedures.
MTBF
The power supply has a minimum MTBF of 206K hours according to MIL-HDBK-217F.
WARRANTY
Artesyn Embedded Technologies shall warrant the power supply to be free of defects in materials and workmanship for a minimum period
of two years from the date of shipment, when operated within specifications. The warranty shall be fully transferable to the end owner of
the equipment powered by the supply.
LCB100 Data Sheet
Mechanical Drawings
WORLDWIDE OFFICES
Americas
Europe (UK)
Asia (HK)
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
While every precaution has been taken to ensure accuracy and completeness in this literature, Artesyn
Embedded Technologies assumes no responsibility, and disclaims all liability for damages resulting from use
of this information or for any errors or omissions. Artesyn Embedded Technologies, Artesyn and the Artesyn
Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc.
All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective
owners. © 2015 Artesyn Embedded Technologies, Inc.
www.artesyn.com
For more information: www.artesyn.com/power
For support: [email protected]
LCB100 DS 10Aug2015
Similar pages