POWERDYNAMICS HGN-365-6M-F2 Iec 60320 inlet socket with single/double fuse holder, flange mount Datasheet

HGN-365
IEC 60320 INLET SOCKET WITH SINGLE/DOUBLE FUSE HOLDER,
FLANGE MOUNT
MECHANICAL DIMENSIONS (Unit: mm)
46.0
36.0+- 0.2
2x 3.3x90 CSK
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
35.0
53.5
41.0
The HGN-365 filter series offers a variety of options with
a current rating up to 6A, 250VAC. This power entry module
offers industry standard 5 x 20mm fuse with IEC connector.
Fully enclosed metal housing prevents input of high
frequency noise and protects ultra-sensitive equipment.
28.0+- 0.5
6.3 TYP.
FEATURES
6.0
These filters are also available for Medical equipment with
low leakage current to comply with UL544 & 2602.
32.5
0.8 TYP.
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
• Rated Voltage: 115/250VAC
• Rated Current: 1A, 2A, 4A, 6A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 250VAC 50Hz: 0.5mA, max
@ 250VAC 50Hz: 2µA*, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
* Medical application
33.0+0.3
36.0+0.2
29.0+0.3
4x R3
RECOMMENDED
PANEL CUTOUT
2x M3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
68
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
HGN-365 Series Example & Ordering Code
HGN-365 - 1
CURRENT RATING (A):
=
=
=
=
SCHEMATIC:
FUSE OPTION:
M - F2
1
2
4
6
STANDARD TYPE
=
WITHOUT C(Y); C(X) ONLY
=M
BLANK
1 FUSE (5X20MM), 6.3/0.25 QUICK CONNECT
= F1
2 FUSE (5X20MM), 6.3/0.25 QUICK CONNECT
= F2
Attenuation Tables & Schematics
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
29
31
19
18
32
36
21
20
50
49
32
30
60 59
57 59
40 49
33 48
79
80
52
61
30 2
42 3
39 2
33 10
4
8
5
12
8
10
10
15
4
10
11
14
48
40
9
9
63
60
40
39
82
82
80
73
70
80
70
73
40
40
39
60
E
P
2200pF
E'
2200pF
LOAD
22
25
11
10
N'
0.033 F
11
11
3
4
0.033 F
10.3mA
4.6mA
1.2mA
0.8mA
L(mH)
N
1M
1A
2A
4A
6A
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
L
Value .01 .05 .1 .15 .5 1 5 10 30 .01 .05 .1 .15 .5 1 5 10 30
LINE
Current
Rating
P'
L(mH)
Medical Applications
Insertion loss in dB (50 Ohm circuit)
32
30
15
14
37
35
20
16
41
37
22
18
51
41
30
26
47 36
42 37
32 32
29 29
31
30
30
29
22
22
22
25
2 5
2 5
5 7
8 14
5
5
7
10
8 48 69 82 74
8 48 69 82 74
5 9 48 82 78
8 9 41 82 80
35
35
45
62
E
P
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
N'
L(mH)
E'
LOAD
22
18
10
8
0.033 F
10.3mA
4.6mA
1.2mA
0.8mA
L(mH)
N
0.033 F
1A
2A
4A
6A
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.01 .05 .1 .15 .5 1 5 10 30 .01 .05 .1 .15 .5 1 5 10 30
1M
L
Value
LINE
Current
Rating
P'
69
Similar pages