HG4138B Miniature PCB / QC Power Relay FEATURES 30A switching capacity PCB + QC termination Meets UL508 and UL873 spacing requirements TYPICAL APPLICATIONS Power supply device Industrial control Home appliances Heating, refrigeration, ventilation CONTACT RATING Form 1 Form A (1H) 240VAC 28VDC Max. Switching Current Max. Switching Voltage Max. Continuous Current 30A 30A 30A Rated Load 30A 8.31KVA 900W Max. Switching Power 1 Form C (1Z) NO NC 15A 20A 10A 10A 20A 10A 10A 20A 15A 277VAC/30VDC 15A 20A 10A 4.155KVA 5.54KVA 2.77KVA 450W 600W 300W 1A, 5VDC/12VAC 1 Form B (1D) Min. Load UL /CSA RATING Load Type Voltage 1 Form A (1H) 1 Form B (1D) General Purpose 240VAC 240VAC 28VDC 240VAC 120VAC 240VAC 120VAC 120VAC 277VAC 30A 30A 20A 2HP 1HP 80A /30A 98A /22A TV5 10A 15A 15A 10A 0.5HP 0.25HP Resistive Motor LRA/FLA Tungsten Ballast 1 Form C (1Z) NO NC 20A 10A 10A 20A 20A 10A 2HP 0.5HP 0.25HP 1HP 30A/10A 50A /20A 20A/7A TV3 3A TV5 10A TV3 3A CONTACT DATA AgCdO, AgSnOInO 50 mΩ, max. at 0.1A, 6VDC Material Initial Contact Resistance Service Life Mechanical 107 ops. Electrical 105 ops. COIL DATA Coil Voltage Code Nominal Voltage (VDC) Resistance (Ω) ±10% Must Operate Voltage max. (VDC) Must Release Voltage min. (VDC) 005 006 009 012 024 048 110 5 6 9 12 24 48 110 27 40 97 155 660 2560 10330 3.75 4.50 6.75 9.00 18.00 36.00 82.50 0.5 0.6 0.9 1.2 2.4 4.8 11.0 CHARACTERISTICS Operate Time Release Time Insulation Resistance Dielectric Strength Shock Resistance Vibration Resistance Power Consumption Ambient Temperature Weight 15 ms. typical 10 ms. typical 1000 MΩ, at 500VDC, 50%RH 1500 Vrms, 1 min. between open contacts 2500 Vrms, 1 min. between coil and contacts 10 g, 11ms, functional; 100 g, destructive DA 1.5mm. 10 - 55 Hz 0.9W, approx. -55 to 85ºC operating, -40 to 130ºC storage 30 g, approx. HG4138B 1/2 HG4138B ORDERING DESIGNATION Example: HG4138B / Model Coil Voltage Code Contact Form 1H: 1 Form A; 1D: 1 Form B; 1Z: 1 Form C Mounting Version 0: PCB Mount Version 1: Sealed; 2: Dust Cover 012 - 1Z 0 1 F Thermal Class Nil: UL Class B; F: UL Class F REFERENCE CURVES OVERALL DIMENSIONS, MOUNTING HOLES AND WIRING DIAGRAM (mm) Overall Dimensions COM NO Mounting Holes (Bottom View) NC Wiring Diagram (Top View) NOTES 1. 2. 3. 4. 5. All parameters, unless otherwise specified, are measured at ambient temperature 23ºC. In mounting holes drawing, the * holes is not needed for 1 Form A, the ** hole is not needed for 1 Form B. To exert optimum electrical life, please remove the tape of sealed version after cleaning process. Custom-made services available with operational quantity. Please let us know your special requirements. Specifications subject to change without prior notice. DB LECTRO INC. 3600 boul. Matte suite I Brossard Qc J4Y-2Z2 TEL:(450)-444-1424 FAX: (450)-444-4714 HG4138B 2/2