Click on Series name for product info on aimtec.com Series AME40-MJZ 40 Watt | AC-DC / DC-DC Converter Picture coming soon FEATURES: Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) 85-264/47-440 85-264/47-440 85-264/47-440 120-370 120-370 120-370 12 24 48 AME40-12SMJZ AME40-24SMJZ AME40-48SMJZ I/O Isolation 4000VAC Operating Temp: -40 °C to +70 °C Input: 85-264VAC/47-440Hz, or 120-370VDC Over current, Over Voltage Protection Continuous Short circuit protection Low no load consumption ≤0.5W Efficiency up to 84% Output Voltage adjustment Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) 9000 2000 1000 84 84 84 3.33 1.66 0.83 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 30 50 Maximum 1 0.6 Units A A A A Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise Hold-up time Voltage adjustment range Conditions Typical Full load LL-HL, Full Load 1-100% load 20MHz bandwidth 115VAC, 20MHz bandwidth 230VAC, 20MHz bandwidth Single output only ±2 ±0.5 ±1 50 15 80 Maximum Units 100 ±10 % % % mV p-p ms ms % of Vout Rated Units 4000 VAC MΩ Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance Typical 60 sec >100 General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Protection class Class II Over current protection ≥110 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery oC Operating temperature See derating curve -40 to +70 oC Storage temperature -40 to +85 oC Maximum Case temperature 100 Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 225 g Dimensions (L x W x H) 3.5 x 2.5 x 0.98 inches 89.0 x 63.5 x 25.0 mm MTBF > 200,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 052e R8 Tel: +1 514 620 2722 1 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME40-MJZ 40 Watt | AC-DC / DC-DC Converter Safety Specifications Parameters Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC/EN/UL 60950-1 EN55022, class B IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 3 IEC 61000-4-6 Level 3 IEC 61000-4-8 Level 3 IEC 61000-4-11 Class 2 55.88 (2.20) Bottom View 6 5 4 3 3.81 (0.15) 1 3.85 (0.15) 81.30 (3.20) 12.70 (0.50) 7 2 63.50 (2.50) 3.81 (0.15) 89.00 (3.50) 15.24 (0.60) 3.81 (0.15) Dimensions 3.85 (0.15) DIV: 10.00 (0.40) 1.20 (0.05) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter ± 0.10 (± 0.004) Side View 6.00 (0.24) 25.00 (0.98) 5Ø 1.70 (Ø 0.07) Pin Out Specifications Pin Single 1 2 3 4 5 6 7 AC Input (L) AC Input (N) +V Output No pin -V Output No pin Trim www.aimtec.com F 052e R8 Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME40-MJZ 40 Watt | AC-DC / DC-DC Converter Deratings AME40-12SMJZ AME40-24SMJZ & AME40-48SMJZ Free Air Convection Free Air Convection 100 Safe Operating Area 100% load 100-264VAC or 120-370VDC 80 70 60 Output Power (%) Output Power (%) 100 45 40 20 Safe Operating Area 100% load 100-264VAC or 120-370VDC 80 60 40 20 0 -30 - 40 -20 0 20 55 40 60 70 80 0 -30 - 40 -20 100 Ambient Temperature º C 0 20 40 55 60 70 80 100 Ambient Temperature º C Free Air Convection at 25°C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 85 100 (100) (120) 264 (370) Input Voltage VAC (VDC) Typical application circuits FUSE 3.15A/300V Single Output NTC MOV S14K350 AC AC N Model Single 12 Vout Single 24 Vout Single 48 Vout www.aimtec.com F 052e R8 + Vout AC L AC L AC N C2 220 µF 120 µF 100 µF DC ‐ Vout + Vout + TVS C1 C2 1µF/50V ‐ Vout TVS 20V 30V 64V Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME40-MJZ 40 Watt | AC-DC / DC-DC Converter Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AME40‐12SMJZ Trim down % Vout (VDC) 1 11.88 183.233 1 12.12 2 11.76 111.59 2 12.24 3 11.64 79.474 3 12.36 4 11.52 61.246 4 12.48 5 11.4 49.499 5 12.6 6 11.28 41.299 6 12.72 7 11.16 35.249 7 12.84 8 11.04 30.602 8 12.96 9 10.92 26.921 9 13.08 10 10.8 23.933 10 13.2 Rt up (KΩ) 211.778 57.03 32.596 22.642 17.238 13.845 11.516 9.819 8.527 7.511 Vout (VDC) 1 2 3 4 5 6 23.76 23.52 23.28 23.04 22.8 22.56 471.081 287.942 205.845 159.249 129.221 108.258 1 2 3 4 5 6 24.24 24.48 24.72 24.96 25.2 25.44 7 22.32 92.793 7 25.68 8 22.08 80.914 8 25.92 9 21.84 71.504 9 26.16 10 21.6 63.865 10 26.4 Rt up (KΩ) 239.556 13.15 11.232 9.771 8.622 Vout (VDC) Rt down (KΩ) Trim up % AME40‐24SMJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % 64.606 36.982 25.728 19.619 15.783 AME40‐48SMJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Vout (VDC) 47.52 47.04 46.56 46.08 45.6 45.12 44.64 44.16 43.68 43.2 Rt down (KΩ) 1216.754 756.639 545.609 424.485 345.902 290.797 250.014 218.613 193.691 173.429 Trim up % 1 2 3 4 5 6 7 8 9 10 Vout (VDC) 48.48 48.96 49.44 49.92 50.4 50.88 51.36 51.84 52.32 52.8 Rt up (KΩ) 374 86.766 48.699 33.664 25.613 20.597 17.172 14.684 12.796 11.313 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8 Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only