TI1 EXC-ML20A390U Ads1131ref and ads1231ref Datasheet

User's Guide
SBAU175A – July 2010 – Revised August 2011
ADS1131REF and ADS1231REF
The ADS1131REF and the ADS1231REF are reference designs for delta-sigma analog-to-digital
converters (ADCs). The ADS1131REF contains the ADS1131 18-bit device, while the ADS1231REF
contains the ADS1231 24-bit device. Both systems contain all the circuitry and user interface elements
needed for a weigh-scale digitizer, and are meant as examples of a good design for a basic weigh-scale
system. Each system is also suitable for general evaluation of the respectively installed ADC. Throughout
this document, the term ADS1x31REF is used to refer to the common features and functions for both
systems.
The ADS1x31REF hardware has the following features:
• ADS1131 ADC for the ADS1131REF and ADS1231 ADC for the ADS1231REF
• Connections for load cells or other voltage sources
• Low-side excitation switch on the load cell header connector
• Ample EMI/RFI suppression between the ADC and rest of design
• Eight-digit starburst LCD readout
• USB connection for firmware updates and remote control
• Designed for very low power consumption
• Battery (9V) or wall power
Version 1.0.0 of the firmware includes the following features:
• Weigh-scale mode with two-point calibration
• Complete configuration of the device
• Real-time peak-to-peak and RMS noise calculation
• Autoranging voltage display
• Noise displayed in volts, codes, and bits
• Voltage displayed in volts or codes
• Adjustable averaging mode
• Raw hexadecimal code display
• Simple and fast configuration
• Parameters saved to internal flash memory
• Computer link
Graphical PC software is also provided for histogram display, datalogging, and device control.
We welcome bug reports and suggestions for additional features; please contact the Texas Instruments
Precision Analog Applications Group.
Hyperterm is a trademark of Microsoft Corporation.
Windows is a registered trademark of Microsoft Corporation.
All other trademarks are the property of their respective owners.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
1
www.ti.com
Contents
1
Getting Started .............................................................................................................. 3
2
Weigh Scale Mode .......................................................................................................... 7
3
Analysis Mode ............................................................................................................. 11
4
Using the PC Software ................................................................................................... 14
5
Serial Console ............................................................................................................. 18
6
Hardware ................................................................................................................... 20
Appendix A
Schematic and Layout ........................................................................................... 23
List of Figures
1
ADS1x31REF Controls and Connectors ................................................................................. 3
2
4-Wire Load Cell to Terminal Block
3
6-Wire Load Cell to Terminal Block
15
...................................................................................... 4
...................................................................................... 5
4-Wire Load Cell to Header................................................................................................ 5
6-Wire Load Cell to Header................................................................................................ 5
ADS1231REF PC Software Display .................................................................................... 15
ADS1x31REF Average Data ............................................................................................. 16
ADS1x31REF Hardware Block Diagram ............................................................................... 20
ADS1x31REF PCB—Top Side .......................................................................................... 25
ADS1x31REF PCB—Layer 1 ............................................................................................ 25
ADS1x31REF PCB—Layer 2 ............................................................................................ 26
ADS1x31REF PCB—Bottom Side ...................................................................................... 26
ADS1x31REF Schematic—ADC ........................................................................................ 27
ADS1x31REF Schematic—MCU ........................................................................................ 27
ADS1x31REF Schematic—USB......................................................................................... 28
1
Unit Conversion Factors and Display Formats .......................................................................... 8
2
Parameters in Configuration Mode ....................................................................................... 9
3
Modes and Example Displays ........................................................................................... 11
4
Voltage Display Ranges .................................................................................................. 12
5
Parameters in Analysis Mode ............................................................................................ 13
6
Console Mode Commands ............................................................................................... 19
7
Load Cell Header Pinout
8
Terminal Block Pinout ..................................................................................................... 22
9
ADS1x31REF Bill of Materials
4
5
6
7
8
9
10
11
12
13
14
List of Tables
2
ADS1131REF and ADS1231REF
.................................................................................................
..........................................................................................
21
23
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Getting Started
www.ti.com
1
Getting Started
A diagram of the ADS1x31REF is shown in Figure 1.
Figure 1. ADS1x31REF Controls and Connectors
1.1
Operating Modes
The ADS1x31REF operates in one of three modes:
• Scale mode: When the mode select switch is in Scale position, the ADS1x31REF acts as a basic
weigh scale. The scale has tare, range, and calibrate functions, and can display metric (SI) units. Other
parameters can be configured in configuration screens. Scale mode is described in detail in Section 2.
• Analysis mode: When the mode select switch is in Analysis position, codes are taken directly from the
installed ADS device and various measurements are made upon them. Several measurements are
available, including raw display, voltage, RMS noise, and peak-to-peak measurements. The ADS1131
or ADS1231 can also be configured directly from this mode. Analysis mode is described in detail in
Section 3.
• Configuration mode: Parameters governing the operation of the ADS1x31REF can be viewed and
altered in this mode. Scale and Analysis modes have different options in configuration mode:
configuration for Scale mode is described in Section 2.4, and configuration for Analysis mode is
described in Section 3.4.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
3
Getting Started
1.2
www.ti.com
Controls
The main controls for the ADS1x31REF are the four buttons and the mode selection slide-switch (see
Figure 1).
The slide-switch selects between weigh-scale (Scale) and Analysis modes. The ADS1x31REF switches
modes only when it is displaying data. If the switch is changed in a configuration mode, nothing happens
until the configuration mode is exited. At that time the ADS1x31REF reads the switch and enters the
selected mode.
The four buttons have different functions, depending on the operating mode. In Scale mode, the switches
have the functions in the box labeled SCALE. In Analysis mode, the switches have the functions shown in
the box labeled ANALYSIS. In configuration mode, the switches have the functions shown in the box
labeled CONFIG.
The buttons also have different names in different modes. In this document, they are identifed by the
respective names they have in the mode under discussion.
1.2.1
Auxiliary Controls
The Reset switch resets the board, except for the USB interface.
The USB Reset switch resets the USB interface. If USB communication fails, pressing USB Reset may
solve the problem.
The Programming Mode switch is used to update the firmware. For normal operation, it should be set to
JTAG.
1.3
Power
To apply power to the ADS1x31REF, connect a 9V battery or plug in a 6V–9V ac wall adapter.
AC adapters must be tip positive/sleeve negative. When an ac adapter is plugged in, the board always
takes power from it, and not from the battery.
The ADS1x31REF is protected against polarity reversal. If a power source is connected in reverse by
mistake, the display remains blank. To prevent damage to the board, do not leave a reversed power
source connected for longer than a few seconds.
1.4
Connecting a Load Cell
The ADS1x31REF is specifically designed for connection to load cells. Two connectors are provided for
this application. The terminal block is used for load cells having stripped wire connections; the load cell
header is for load cells having a header connector. The terminal block provides connections to the
reference input (or power supply) and the header has switched excitation.
1.4.1
Connecting a 4-Wire Load Cell to the Terminal Block
Figure 2 shows the connection of a 4-wire load cell to the terminal block. In this configuration, the load cell
is excited by the +5V power supply, and the ADC reference is taken from the power supply.
For this configuration, the reference select switch must be in the +5VA position.
OUTEXC+
OUT+
EXCSNSSNS+
SIG+
SIGEXC+
EXC-
Figure 2. 4-Wire Load Cell to Terminal Block
4
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Getting Started
www.ti.com
1.4.2
Connecting a 6-Wire Load Cell to the Terminal Block
Figure 3 shows the connection of a 6-wire load cell to the terminal block. In this configuration, the load cell
is excited by the +5V power supply, and the ADC’s reference is taken from the sense wire returning from
the load cell. The sense wire connects to the excitation wire at the bridge sensor.
OUTSENSE+
EXC+
EXCSNSSNS+
SIG+
SIGEXC+
OUT+
EXCSENSE-
Figure 3. 6-Wire Load Cell to Terminal Block
1.4.3
Connecting a 4-Wire Load Cell to the Header
Figure 4 shows the connection of a 4-wire load cell to the header. In this configuration, the load cell is
excited by the +5V power supply, and the ADC reference is taken from the power supply.
EXC+
OUTOUT+
EXC-
6
5
4
3
2
1
Figure 4. 4-Wire Load Cell to Header
For this configuration, the reference select switch must be in the +5VA position; the EXT position does not
work.
1.4.4
Connecting a 6-Wire Load Cell to the Header
Figure 5 shows the connection of a 6-wire load cell to the header. In this configuration, the load cell is
excited by the +5V power supply, and the ADC reference is taken from the sense wire returning from the
load cell. The sense wire connects to the excitation wire at the bridge sensor.
EXC+
SENSE+
OUT+
OUTSENSEEXC-
6
5
4
3
2
1
Figure 5. 6-Wire Load Cell to Header
For this configuration, the reference select switch should be in the EXT position for best performance. The
+5V position also works, but the device may not perform as well.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
5
Getting Started
1.5
www.ti.com
Connecting Other Signal Sources
In general, the ADS1x31REF can accurately measure any voltage in the input range of the installed ADS
device, as long as the following rules are observed:
• Never apply a negative voltage to the inputs of the ADS1x31REF. The installed ADS device cannot
accept negative voltages at its input. Applying negative voltages may damage both the device and the
ADS1x31REF. (The negative signs used in some signal names indicate inversion, not polarity.)
• For single-ended signals, ground the negative input or connect it to 2.5V. 2.5V is available from a
voltage divider by shorting J7; see Section 6.4.5 for details.
• The input range of the amplifier on the ADS1131 or ADS1231 does not extend to the supplies. See the
ADS1131 data sheet or the ADS1231 data sheet for details.
Note that Scale mode is designed only for use with load cells. Although it can be tested with a voltage
source or resistive divider, Scale mode does not, in general, display meaningful data unless a load cell is
connected and calibration is performed.
1.6
Connecting an External Clock
Note that only the ADS1231 can receive an external clock. To connect an external clock, connect a clock
oscillator to the EXTCLK test point. No settings need to be changed; the ADS1231 will automatically use
the attached clock.
The clock source must conform to 3.3V TTL or CMOS logic rules.
1.7
1.7.1
Common Tasks
Shorted-Input Noise Test
The noise measurements given in the product data sheet are taken with the inputs shorted to 2.5V. These
noise measurements can be replicated on the ADS1x31REF with no external hardware. To set up these
measurements on the ADS1x31REF, perform the following steps:
1. Move the mode switch to Analysis mode.
2. Short jumpers J8 and J7. (These jumpers are located very near the terminal block, and are marked
Input Shorting Jumpers in Figure 1.)
3. Set up the installed ADS device as desired, as described in the previous sections.
4. Hold down the DISP button. The display shows the current display mode. While holding down DISP,
press the MODE button until the word on the left side is RMS.
5. While still holding down DISP, press the UNIT button until the word on the right side is VOLT.
6. Release the DISP button. The display shows the word GOT followed by an increasing number. Once
the appropriate number of points is collected, the calculated noise voltage is displayed. This value is
the shorted-input RMS noise voltage, input-referred.
The first RMS noise measurement may be incorrect as a result of device settling. The second
measurement is generally correct.
For a detailed description of Analysis mode, see Section 3.
1.7.2
Measuring Mass
The following items are required to measure mass with the ADS1x31REF:
• A load cell, connected as described in Section 1.4
• An object of known mass within the load cell range
To avoid performing calibration on each power-up, you can save the calibration settings to flash memory.
See Section 3.4.1 for details.
6
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Weigh Scale Mode
www.ti.com
Obtaining a calibration weight:
Before the ADS1x31REF can display the mass of an object, it must measure the output of the load cell for
a previously known mass. The known mass can be adjusted.
At power-up, the ADS1x31REF expects a 5kg mass. If this mass is not available, or if the load cell range
is not compatible with this mass, the calibration mass can be changed in the following manner:
1. Determine the mass of the calibration weight. The most accurate way to determine the mass is to
weigh the calibration object on an accurately calibrated scale. If the weight is precalibrated, its given
mass can be used, although this approach is not generally as accurate. (Note that the accuracy of the
ADS1x31REF as a scale directly depends on the accuracy to which the calibration weight can be
measured.)
2. Switch the mode switch to SCALE mode.
3. Press the PARM buttons simultaneously. The ADS1x31REF enters configuration mode.
4. Use the PARM buttons to select the screen which shows UNIT =. This screen allows you to select the
units used for the calibration mass. If the units shown are not correct, adjust them using the VALUE
buttons.
5. Use the PARM buttons to select the screen that shows CW= followed by the calibration mass. On this
screen, you can adjust each digit of the calibration mass separately. Select the digit using the PARM
buttons. The currently-selected digit flashes, and can be adjusted using the VALUE buttons.
6. Adjust the calibration mass to match the mass of the calibration weight.
7. Press the PARM buttons simultaneously to exit the configuration mode.
Preparing Scale mode:
Do the following steps to set up the scale mode:
1. Connect the load cell.
2. If the input shorting jumpers J8 and J7 are connected, disconnect them (see Figure 1).
3. Obtain a weight of known mass.
4. If the mass of the weight is not equal to the configured calibration mass, adjust the calibration mass as
described above.
5. Move the mode switch to SCALE position. If calibration has not been performed, the display reads
NO CAL.
6. Press the CAL button, and follow the calibration procedure given in Section 2.3.
If the calibration is performed properly, and the load cell is connected correctly, the ADS1x31REF will
measure the mass of an object placed on the load cell (provided that the mass of the object is within the
device range).
Weigh scale mode is described in detail in Section 2.
2
Weigh Scale Mode
In weigh scale mode, the ADS1x31REF displays mass. (1) Mass is displayed in either SI or avoirdupois
units based on the voltage received from a load cell.
The ADS1x31REF operates in Scale mode when the mode switch is set to the Scale position.
To accurately calculate mass, the ADS1x31REF must have calibration information for the load cell. When
scale mode is first entered, the ADS1x31REF displays NO CAL, because the ADS1x31REF has no
calibration data when it is powered on.
By default, mass is calculated from the average of four successive readings from the ADC. The number of
points for averaging can be adjusted, and averaging can be turned off.
(1)
Load cells do not measure mass directly; they output a voltage proportional to the weight of an object. The mass of an object can be
accurately inferred from this voltage as long as a calibration is accurately performed, the downward force of gravity remains constant (as
it does if the load cell is not moved to a different altitude), and the tilt of the load cell does not change; if either of the latter conditions
change, a new calibration must be performed.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
7
Weigh Scale Mode
2.1
www.ti.com
Display
Weigh scale mode can display mass in these units: μg (displayed as ug), g, kg, pounds (lb), stone (st),
and ounces (oz). (2)
Internally, mass is measured in grams, and calibration factors are stored in grams. At display time, grams
are converted to the desired display unit using the conversion factors given in Table 1.
xxx
(2)
The avoirdupois units used by the ADS1x31REF are equal in the imperial and U. S. customary systems.
Table 1. Unit Conversion Factors and Display Formats
Unit
Multiplier
Format
6
micrograms (μg)
10
nnn.nnnug
milligrams (mg)
1000
nnn.nnnmg
grams (g)
1
nnn.nnng
–3
kilograms (kg)
10
nnn.nnnkg
ounces (oz)
0.035274
nnn.nnnoz
pounds (lb)
0.0022046
nnn.nnnlb
stone (st)
157.473 × 10−6
nnstnn.nn
The display format for stone differs from the format used for the other units. One stone is equal to fourteen
pounds; weight in stone is commonly expressed as a number of stone followed by a number of pounds.
On the ADS1x31REF, two digits are shown for stone, followed by st, followed by pounds displayed to two
decimal places.
2.1.1
Calculation of Mass
Mass is calculated from ADC code using the formula:
w = m ● c + wzs – wt
where:
• w = mass
• c = the ADC code
• wt = tare weight
• m, wzs, wt = values determined in the calibration process
m is a calibration constant, and is calculated using Equation 1:
wfs
m=
cfs - czs
(1)
where wfs is the user-specified calibration mass, cfs is the ADC code taken with the calibration mass
applied, and czs is the ADC measurement taken with no load.
wzs , the zero-scale mass, is calculated from m and czs using Equation 2:
wzs = –m ● czs
2.2
2.2.1
(2)
Button Functions
TARE
The tare function allows the mass of a substance to be measured separately from the mass of its
container. When the TARE button is pressed, the scale measures the mass and records it. This reading is
subtracted from each subsequent measurement.
The recorded tare value can be reset to zero by holding the TARE button down for at least one second.
When the tare value is to be reset, the display reads TARE OFF.
Tare is also reset following a calibration.
8
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Weigh Scale Mode
www.ti.com
2.2.2
RANGE
The RANGE button changes the units or range of the display. RANGE cycles through all available units;
see Section 2.1 for details. When the RANGE button is depressed, it displays the selected unit.
2.2.3
CAL
Pressing CAL initiates the two-point calibration sequence. See Section 2.3 for details.
2.3
Calibration
Two-point calibration is performed by pressing the CAL button. When this button is pressed, the board
executes the following command sequence:
1. The board scrolls the message, REMOVE WEIGHT.
2. The user removes all weight from the load cell and presses any button.
3. The board measures the load cell voltage and records it as the zero point.
4. The board scrolls the message PLACE CAL WEIGHT.
5. The user places a weight on the load cell and presses any button. The weight should have the mass
that was selected in the configuration mode.
6. The board measures the load cell voltage and records it as the calibration weight.
New calibration data is lost when power is removed. To prevent this data loss, calibration data can be
saved, with other board settings, to flash memory. See Section 3.4.1 for details.
2.4
Configuration
The parameters for Scale mode can be adjusted in the configuration mode.
To enter configuration mode, press the PARM buttons simultaneously. The four buttons then assume the
functions shown in the CONFIG box. To exit Configuration mode, press the PARM buttons simultaneously
again. This function does not cause parameters to be adjusted, because only button releases are detected
in Configuration mode.
Configuration mode contains a number of adjustable parameters. To scroll through the available
parameters, use the PARM buttons. To change the parameter values, use the VALUE buttons.
Some items in configuration mode are not parameters, but commands or gateways to a submenu. These
items are labelled as words with a question mark. To enter these or to execute the command, press SEL
or ENT.
All parameters in the analysis and scale configuration menus are independent, including the parameters
found in both modes.
Table 2 summarizes the available parameters.
Table 2. Parameters in Configuration Mode
Display
Value Range
Display units
Parameter
UNIT=
μg, mg, g, kg, lb, st, oz
Averages
AVGS=
2–128
Description
Display units
Number of points to
average
ADC speed
SPD=
FAST, SLOW
Calibration mass
CW=
0–99.9 in various units
Calibration mass and unit
Save parameters
SAVE?
—
Save parameters; see text
Version number
V1.0.0
—
Firmware version number
display
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Acquisition rate
ADS1131REF and ADS1231REF
9
Weigh Scale Mode
2.4.1
www.ti.com
Parameters
Display units: The units to use when displaying mass. Available units are μg (displayed as ug), mg, g, kg,
ounces (oz), pounds, (lb), and stone (st). See Section 2.1 for details.
Averages: Number of points to use when reading weight. The choices available are 2, 4, 8, 10, 16, 32,
50, 64, 100, and 128. The default is 50.
ADC speed: This parameter selects between the two data rates on the installed ADS device, which are
called high-speed and low-speed. When high-speed mode is selected, FAST is shown; for low-speed
mode, SLOW is shown. (1)
The actual data rate of the ADS1131 or ADS1231 depends on the frequency of the master clock, fCLK. In
fast mode, the data rate is fCLK/61440; in slow mode, the data rate is fCLK/491520. See the ADS1131 data
sheet or the ADS1231 data sheet for further information.
The default setting is low-speed mode.
Calibration weight: This parameter gives the expected mass of the calibration weight used in the
calibration procedure (Section 2.3). The calibration mass can be given in any of the available units, in
three significant figures. The unit is independent of the display unit.
Each digit in the mass is adjusted separately. The currently-selected digit flashes, and can be adjusted
with the VALUE buttons. The PARM buttons are used to select the digit. The unit is adjusted in the same
manner, and flashes when selected.
When the unit is changed, the value changes to the equivalent mass in the new unit.
Save parameters: This screen allows the settings of the ADS1x31REF to be stored in flash memory. It
functions the same as it does in Analysis mode. When ENT or SEL is pressed on this screen, the
ADS1x31REF saves its settings to flash memory. These settings are loaded from flash memory when the
board is reset or powered on. All operating parameters are saved, including scale calibration settings,
voltage reference, display mode, and units.
Version number: This screen displays the version number of the ADS1x31REF firmware.
(1)
10
The ADS1x31REF cannot detect the frequency of the ADS1231 master clock, so it cannot display the actual data rate of the ADS1231
device.
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Analysis Mode
www.ti.com
3
Analysis Mode
In Analysis mode, the ADS1x31REF analyzes code output from the installed ADS device and displays it in
different ways. Table 3 summarizes the numerous display modes available, together with example
displays.
NOTE: The values shown in Table 3 are consistent for a 24-bit device, such as the ADS1231.
However, the ADS1131 is an 18-bit device, so the actual number of codes will be fewer than
the examples shown here.
Table 3. Modes and Example Displays
Hex Code
Dec Code
Voltage
ENOB
Raw
1992E9H
+1676001
+499.488M
n/a
RMS
n/a
+5.789
+17.495N
+23.18BIT
Peak-to-Peak
n/a
+31.256
+90.293N
+21.92BIT
Averaged
n/a
+1676001
+499.488M
n/a
The ADS1x31REF operates in Analysis mode when the mode switch is set to the ANALYSIS position.
The default Analysis mode is RAW HEX.
To change measurement types, hold down DISP and press MODE. This function cycles through the four
available measurement types. When DISP is released, the newly selected measurement is made. To
change units, press UNIT. This option cycles through the available units for the active measurement type.
This procedure can also be done while DISP is depressed; in that case, the new unit is shown by name
on the display. The measurement modes are described in detail in Section 3.2.
The ADS1131 or ADS1231 itself can be configured directly from this mode, as described in Section 3.1.
3.1
Switch Functions
NEW BLOCK: Pressing this switch resets the collection process for the RMS, peak-to-peak, and
averaged measurements.
UNIT: Cycles between available units. Not all units are available in all modes.
DISP: When this switch is pressed, the display shows the current measurement mode and unit. While
DISP is still pressed, pressing NEW BLOCK / MODE cycles through the available measurement modes.
CHIP: Holding this switch down allows the settings of the installed ADS device to be changed, using the
PARM (NEW BLOCK) and VAL (UNIT) buttons.
Pressing PARM while CHIP is pressed down cycles through the available parameters of gain and data
rate.
The gain setting is displayed as GAIN= followed by the gain setting. The gain setting is for display only,
because the gain is fixed at 64 for the ADS1131 and 128 for the ADS1231.
Data rate is shown on the display as SPD=FAST or SPD=SLOW. See ADC speed in the Parameters section
for further information.
If any of these parameters are changed during a multisample measurement, the measurement is
restarted.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
11
Analysis Mode
3.2
www.ti.com
Measurement Modes
Raw: In this measurement, codes are read from the installed ADS device and displayed. No processing or
analysis is done on the sample stream. Data can be displayed as hexadecimal codes, decimal codes, or
volts.
Voltage is calculated according to Equation 3:
vREF
x
v=
·
B-1
A
Where:
•
•
•
•
A is the converter gain (64 for the ADS1131 and 128 for the ADS1231)
vREF is the voltage at the converter reference input
x is the ADC decimal code
B is the number of converter bits, 218 for the ADS1131 and 224 for the ADS1231
(3)
vREF is adjustable from Configuration mode. By default, it is 5V.
The voltage display is autoranging. All ranges are shown with six significant figures having three decimal
places. The ranges are given in Table 4.
Table 4. Voltage Display Ranges
VOLTAGE RANGE
DISPLAY SUFFIX
Nanovolts
< 1μV
n
Microvolts
< 1mV
u
Millivolts
< 1V
m
Volts
≥ 1V
V
RMS noise: In this mode, a number of codes are read from the installed ADS device, and an RMS noise
calculation is performed on them using the standard-deviation formula (given in Equation 4):
sN =
N
2
1å
N i =1(xi - x)
(4)
The result can be displayed as decimal codes, volts, or an effective number of bits (ENOB). For decimal
codes, sN is displayed directly. (Hexadecimal is not available because sN may be fractional.) For volts, sN
is converted to a voltage as in raw mode.
ENOB: E is calculated using Equation 5:
E=
N - log2sN : sN ¹ 0
24 : sN = 0
(5)
Where N is the maximum number of available bits (18 for the ADS1131 and 24 for the ADS1231).
The zero case is needed when a string of equal codes is read. This can happen when the converter is
clipping.
This measurement requires a number of codes to be read before a calculation can be made. Therefore,
during the first run, the display shows the word GOT followed by the number of samples collected. This
event happens when the mode is first entered, when the converter configuration changes, or when NEW
BLOCK is pressed.
The number of codes used in the calculation is selected in Configuration mode; 50 codes are used in
laboratory characterization, so this value is the default.
Peak-to-peak noise: In this mode, a number of codes are collected, and the absolute value of the
difference between the minimum and maximum is calculated. The result can be displayed in decimal or
hexadecimal codes, volts, or noise-free bits (ENOB). Volts are calculated as in raw mode; ENOB is
calculated in the same way as in RMS mode.
12
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Analysis Mode
www.ti.com
The number of codes used in the calculation is selectable in Configuration mode.
Averaged: In this mode, a number of codes are collected, and the average is calculated. The result can
be displayed in decimal codes or volts. (Hexadecimal is not available because the result may be
fractional.) Volts are calculated as in raw mode.
The number of codes used in the calculation is selectable in Configuration mode.
3.3
Progress Graph
The row of apostrophes at the top of the display are used to indicate measurement progress. In Raw
mode, the apostrophe moves across the display when data is being received from the converter.
In block collection modes, the apostrophes form a bar graph. As the collection of a block proceeds, the
bar graph increases. When the bar graph reaches all the way to the right, the new result is generated and
collection restarts.
3.4
Configuration
To enter Configuration mode, press the PARM buttons simultaneously. The four buttons then assume the
functions shown in the CONFIG box. To exit Configuration mode, press the PARM buttons simultaneously
again. This operation does not cause parameters to be adjusted; only button releases are detected in
Configuration mode.
Configuration mode contains a number of adjustable parameters. To scroll through the available
parameters, use the PARM buttons. To change the parameter values, use the VALUE buttons.
Some items in configuration mode are not parameters, but commands or gateways to a submenu. These
items are labelled as words with a question mark. To enter these items or to execute the command, press
SEL or ENT.
Although a few of the parameters in the Analysis and Scale configuration menus are the same, the
settings are kept separate between the modes.
Table 5 summarizes the available parameters.
Table 5. Parameters in Analysis Mode
Parameter
3.4.1
Display
Value Range
Description
Averages
AVG=
2–128
Number of points for average,
peak-to-peak, and RMS modes
Voltage Reference
VREF=
0.5–5.0
Voltage used in various
calculations
Power-down mode
PDWN?
—
Power-down mode; see text
Save parameters
SAVE?
—
Save parameters; see text
Version number
V1.0.0
—
Firmware version number display
Parameters
Averages: Number of points to use in Averaged, RMS noise, and Peak-Peak calculations. The choices
available are 2, 4, 8, 10, 16, 32, 50, 64, and 128. The default setting is 50.
Voltage reference: To convert voltages to codes, the ADS1x31REF requires the voltage reference level.
Since this level cannot be measured, it must be selected manually. This parameter allows the reference
level to be set.
Each digit of the voltage reference is selected and adjusted separately. Use the PARM buttons to select a
digit, and the VALUE buttons to adjust it. The selected digit flashes.
This parameter does not affect the actual voltage reference used. If it is incorrect, voltage calculations will
be wrong. The voltage reference is typically the +5V rail; the default value for this parameter is 5.0V.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
13
Using the PC Software
www.ti.com
Power-down mode: When ENT or SEL is pressed on this screen, the ADS1x31REF causes the installed
ADS device to enter power-down mode. This action occurs by pulling the PDWN line low. While the
PDWN line is low, the display reads POWER DN. When a button is pressed from this display, the
ADS1x31REF powers the converter on and returns to the analysis display, exiting configuration mode.
This mode can be used to test the current consumption of the board when the installed ADS device is
powered down.
Version number: This screen displays the version number of the ADS1x31REF firmware.
4
Using the PC Software
The ADS1x31REF is supplied with software that performs various analyses on data received from the
board via the USB connection. It also provides a means of recording received data to a file.
The program currently runs only on a Microsoft Windows® platform. In Windows, the program
communicates with the ADS1x31REF using a virtual COM port driver that causes the USB connection to
appear to Windows as a normal serial port. The necessary driver is installed with the EVM software.
4.1
Installation and Setup
The ADS1x31REF software is distributed in an installer program called
ADS1x3x-setup-withLVRT-1.3.0.exe (the version number in the file name may differ), distributed on the
CD-ROM or available from Texas Instruments. To install the software, execute this program. The program
guides you through the installation process.
Note the following points:
• The installer installs two packages: the ADS1x3xREF program itself, and the TI Virtual COM Port
driver.
• If any version of the ADS1x3xREF program is already installed, the installer uninstalls it and quits. You
must run the installer again to complete the installation.
• If the Virtual COM Port driver is already installed, the installer offers to uninstall it. Do not uninstall it;
cancel this part of the installation.
The installer displays messages reminding you of these points.
4.1.1
First Time Connection of the ADS1x3xREF
If the ADS1x31REF has never been connected to your computer before, Windows detects the device as
unknown hardware and takes you through a series of dialogs to install the correct driver. Accept the
default settings; the driver is present and only needs to be copied to the correct location. If the driver is
successfully installed, Windows does not issue this prompt again.
On some computers, if the board is connected to a different USB port, the operating system detects the
board as new hardware. If this action occurs, proceed through the new hardware dialogs as usual, and
allow Windows to reinstall the driver.
4.2
The Display
The ADS1x31REF software has a single display; see Figure 6 for a typical display. The major elements of
the display discussed next.
Strip chart: This feature displays a scrolling graph of data received from the board.
Histogram: A sliding histogram of data received from the board is also displayed. The number of points
used in the analysis is adjustable.
DC analysis section: The results of RMS noise analysis, peak-to-peak analysis, and a running voltage
number are shown in this section. The number of analysis points and the reference voltage used for
voltage calculations are also adjustable here.
Recording section: This feature controls recording of data to a file.
Device control section: This section allows device parameters to be adjusted.
14
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Using the PC Software
www.ti.com
Status display: This display shows messages indicating the current state of the program.
Acquire button: This button starts and stops the running acquisition of data.
4.3
Starting the Program
When the program launches, a screen similar to that shown in Figure 6 appears. Immediately after launch,
the program searches all available serial ports for the board. To do this step, it opens every available
serial port in turn, testing it to see if there is an ADS1x31REF connected. The program uses the first
ADS1x31REF it finds. Note that the title block displays the name of the board found. Figure 6 shows the
board found as the ADS1231REF. If the ADS1131REF is connected, the title shows ADS1131REF.
Figure 6. ADS1231REF PC Software Display
Although this procedure is conceptually simple, it may not go as smoothly as expected. The following
process ensures that the board is found correctly. Note that Steps 1–3 can be done in any order.
Step 1. Apply power to the ADS1x31REF.
Step 2. Plug in the USB connector.
Step 3. Start the program.
Step 4. Watch the status display. It reads Scanning followed by the name of the serial port being
tested. When the board is found, the display reads Idle. Until a board is found, the display
cycles through every port, spending approximately one second on each port.
Once the board is detected, the program enters Idle mode and is ready for use.
NOTE: If the board is never detected, it is still possible (and safe) to exit the program during the
search process. If the board does not respond, pressing the USB Reset switch (SW1) may
help.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
15
Using the PC Software
4.4
www.ti.com
Analysis or Record Mode
The program will operate in analysis mode or record mode. Both modes acquire the data and update the
displays, but record mode also writes the result to the selected file.
4.5
Adjusting Device Parameters
To adjust device parameters, use the controls in the Device control box. Each control corresponds to a
setting that can also be made from the board itself.
4.6
Acquiring Data
To start receiving and analyzing data from the board, click the Acquire button, located in the lower
right-hand corner of the display. The program begins to receive data from the board, displaying the results
in near-real time.
It is not possible for the program to adjust board parameters in Analysis mode. For this reason, the board
controls are disabled and dimmed while Analysis occurs.
4.6.1
Averaging
The PC software can process data collected from the board using a sliding-window averager. The controls
for the averager are found in the Averager box.
To turn the averager on, use the Averaging switch. The number of points averaged is set by the Points
control, and the number of points currently collected is shown in the Collected box.
When the averager is turned on, it is cleared. To reset the averager, turn it off and then on again.
The histogram displays an integer representation of the averaged data. Note that when selecting a high
number of averages, the integer results might include only one code; the histogram for that case will be
blank. The strip chart display shows both the full precision result of the averages and the integer version,
as illustrated in Figure 7.
Strip Chart
Histogram
Figure 7. ADS1x31REF Average Data
16
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Using the PC Software
www.ti.com
4.6.2
Block Analysis Length
The histogram, RMS, and peak-to-peak calculations require a set of samples. These calculations are
updated with every group of samples received, and are performed on a block of the most recently
acquired (or averaged) samples.
The number of samples used is set using the Analysis points control. By default, this number is 100, but
can be changed at any time. This value also controls the RMS and peak-to-peak noise analysis lengths.
If the number of samples collected is not yet equal to the number of samples specified by the Analysis
points control, 0s are substituted for the samples not yet received.
In Analysis mode, the analysis can be reset using the button marked Reset analysis. This function clears
the internal analysis buffer. This button cannot be used outside of Analysis and Recording modes.
Analysis is automatically reset when Analysis and Recording modes are entered.
4.6.3
RMS and Peak-to-Peak Noise Analysis
The RMS and peak-to-peak noise analysis calculations are performed in exactly the same way as they are
in the ADS1x31REF firmware, as described in Section 3.2. Each calculation can be displayed in units of
volts, codes, or bits, as on the board. See Section 3.2 for detailed descriptions of the calculations.
The number of samples used in each calculation is set using the Analysis points control. By default, this
number is 100, but can be changed at any time. This control also controls the histogram length.
4.6.4
Displaying Volts
When units of volts are displayed, the program must have a value for the reference voltage applied to the
installed ADS device to properly calculate the voltage. Because this voltage cannot be measured using
the ADS1x31REF, it is set manually using the Vref control.
The value of Vref defaults to 5V, because the reference is normally taken from the 5V power supply. If a
different reference voltage level is used, the value of Vref should be changed to reflect the different level,
so that voltage calculations are performed correctly.
The Vref control also affects voltages recorded in Record mode.
4.6.5
Block Acquisition
To enable the program to run reliably on slower computers, results are not calculated each time a sample
is received. Instead, groups of samples are collected and added to an analysis buffer that is processed as
it becomes full. This processing delay is timed so that the display updates at least every 0.75 seconds.
4.7
Data Recording
The ADS1x31REF software can record incoming samples to a text file. This file can be loaded into other
programs for analysis. Data recording is performed using the controls in the Recording box.
Follow these steps to record data to a file:
Step 1. Select or create a destination file. Either type the file path directly into the Destination file
control, or click the small open folder icon to the right of the control to open a dialog box from
which a file can be selected. If the selected file exists already, the program will display a
warning. Otherwise, type the name of the file that you wish to create.
Step 2. Select a data format. Samples can be recorded as raw (decimal) codes or as volts. In both
cases, the data are written to the file as ASCII data, and the file is a text file.
Step 3. Click the Record button. The program begins to collect and analyze data from the board, as
well as write it to the selected file. As recording proceeds, the recording time indicators are
updated.
Step 4. Click Record again to stop the recording when the desired amount of data has been
collected.
The selected file is not opened or created until recording begins. If an error occurs at that time, recording
stops and a message displays in the status box.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
17
Serial Console
www.ti.com
Recording time is not measured, but calculated from the number of samples collected. The speed is used
to determine the amount of time for each sample. If the data rate is changed at the board, the recording
time will be incorrect. This change does not affect the data file, except that samples continue to be
collected with the different settings.
In Recording mode, analysis proceeds as in Analysis mode; Recording mode is identical to Analysis
mode, except that data is written to a file. See the previous section for documentation on Analysis mode.
When Recording mode begins, if the selected file exists, it is erased and overwritten. The pre-existence of
the file is checked only when a new file is selected.
4.7.1
File Format
Data files begin with a header that contains the text collected from ADS1x31REF, the time of recording,
and the speed and gain. Following this header, values are written in either volts or raw codes, with one
value per line. Line separators are in DOS format, consisting of a carriage return and a line feed. This
format can be examined in a text editor and loaded or imported into most other software, including
spreadsheets.
Voltages are calculated using the reference voltage given in the Vref control; it is therefore important that
this value be correct.
5
Serial Console
The ADS1x31REF provides a console mode that can be used with any Windows terminal emulation
program, such as Hyperterm™. In Windows, this configuration is done through the Virtual COM Port driver
supplied with the EVM software, causing the ADS1x31REF to appear in Windows as an extra serial port.
5.1
Using the Console
To use the console, load a terminal emulation program and connect to the EVM serial port using the
following parameters:
• Baud rate: 115200
• Data bits: 8
• Parity: none
• Stop bits: 1
• Flow control: none
• Local echo: off
• Terminal emulation: ANSI or VT100
Setting up the terminal program is beyond the scope of this document; see the specific terminal program
documentation for details.
To locate the serial port, try higher port numbers first. When the board first starts, it outputs the following
message:
ADS1131REF 1.0.0 (c)2010 Texas Instruments
1131>
for the ADS1131, or :
ADS1231REF 1.0.0 (c)2010 Texas Instruments
1231>
for the ADS1231. Pressing Reset causes the board to output this message.
The command prompt is always 1131> for the ADS1131 and 1231> for the ADS1231. Commands are
entered at this prompt. Commands consist of one letter possibly followed by arguments. The format of the
arguments depends on the command.
Commands are case insensitive. Upper-case characters are printed here, but lower-case characters also
work.
18
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Serial Console
www.ti.com
The available commands are listed in Table 6. In this table, values in brackets indicate a range or list of
possible characters. A dash (–) indicates a range, and commas (,) indicate a list.
Table 6. Console Mode Commands
COMMAND
FORMAT
OPERATION
P
—
Prints the current gain
setting
R
R [F,S]
Set data rate
V
V
Show firmware version
S
S
Start streaming
D
D
Read data once
Q
Q
Query parameters
Console mode does not interrupt standalone operation. It is always available, even when the standalone
mode is in use. However, if parameters are changed using both the console and standalone modes,
parameters may become out of sync.
5.2
5.2.1
Command Reference
P—Set PGA
This command has no effect on the ADS1131 or ADS1231 because the device gain is fixed.
• P—(with no argument) prints the current gain setting
5.2.2
R—Set Data Rate
This command sets the speed of the installed ADS device according to these parameters:
• RF—sets rate to fast
• RS—sets rate to slow
• R—(with no argument) prints the current data rate setting
Note that the actual data rate depends on the frequency of the device clock.
5.2.3
V—Show Version
Displays a message containing the firmware version and copyright notice.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
19
Hardware
5.2.4
www.ti.com
S—Start Streaming
When S is issued, the ADS1x31REF begins printing raw output codes from the installed ADS device in
hexadecimal format, separated by new lines. The device iterates continuously until a character is received
from the serial port.
S is used primarily by the EVM software for data collection.
5.2.5
D—Collect One Sample
Issuing the D command causes the ADS1x31REF to report the latest collected sample from the installed
ADS device. The sample is displayed in raw hexadecimal.
5.2.6
C—Set Channel
This command has no effect on the installed ADS device because there is only one channel.
• C0—set to channel 0
• C—(with no arguments) prints the current channel, always CHAN=0
5.2.7
Q—Query Parameters
Q causes the ADS1x31REF to issue a coded string summarizing the current settings. The format of the
string is:
P0R[F,S]OIC0
followed by a carriage-return and linefeed.
6
Hardware
A block diagram of the ADS1x31REF is shown in Figure 8. The schematic and layout drawings are given
in Appendix A.
SWITCHES
LCD
INPUT
GPIO
CH1
MSP430F449
ADS1x31
SPI
FILTERING
UART
+5V
LOAD CELL
POWER
USB-SERIAL
CONNECTORS
SUPPLY
INTERFACE
+3.3V
USB CONNECTOR
Figure 8. ADS1x31REF Hardware Block Diagram
20
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Hardware
www.ti.com
6.1
Microcontroller
The ADS1x31REF uses the MSP430F449 microcontroller. This device provides an LCD controller,
hardware SPI and UART interfaces, and a multiplier. The latter is important because the firmware must
perform many multiplications.
6.2
Power Supply
The ADS1x31REF operates from +5VDC and +3.3VDC. These supplies are generated by linear regulators
U1 and U2. Input power comes from either wall-adapter connector J2, or battery connector BT1. J2 is
switched; when a connector is plugged in, BT1 is disconnected.
Noise is important because the ADC voltage reference is typically taken from the power supply. The
supplies are heavily bypassed to reduce noise.
6.3
User Interface
The ADS1x31REF user interface consists of the display and switches SW2–5 and SW8. Switches are
connected to interrupt-capable GPIOs on the microcontroller, allowing them to wake the microcontroller
from sleep mode.
6.4
ADC Section
The ADC section consists of the installed ADS device itself and ancillary circuitry.
All signals on the installed ADS device are filtered by pass-through capacitors that help to reject
electromagnetic interference (EMI), radio frequency interference (RFI), and noise generated by the digital
circuitry.
6.4.1
Input Circuitry
The ADS1x31REF is designed to connect to resistive bridge sensors, particularly load cells. The input
channel is filtered by pass-through capacitors C38 and C39 and differential capacitor C7. Common-mode
capacitors C32 and C29 provide additional RF rejection.
6.4.2
Load Cell Header
The load cell header, J6, provides a convenient terminal for load cells having a properly fitted header
connector. It provides excitation and sense connections. The negative excitation line is connected to
ground through the installed ADS device. The ADS device conserves power by allowing excitation current
to flow only during conversion. See the ADS1131 data sheet or the ADS1231 data sheet for more
information.
The load cell connector’s pinout is given in Table 7. For connection examples, see Section 1.4.3 and
Section 1.4.4.
Table 7. Load Cell Header Pinout
PIN NO.
PIN NAME
1
EXC+
2
EXCSNS+
3
SIG+
Input for positive load cell output
4
SIG–
Input for negative load cell output
5
EXCSNS–
Negative sense; connected to external negative reference input
6
EXC–
Negative excitation; connected to ground through installed ADS
device
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
FUNCTION
Positive excitation; connected to +5VA
Positive sense; connected to external positive reference input
Copyright © 2010–2011, Texas Instruments Incorporated
ADS1131REF and ADS1231REF
21
Hardware
6.4.3
www.ti.com
Input Terminal Block
The input terminal block consists of J4 and J5. It provides connections to all of the analog inputs on the
installed ADS device, and connections to the ADS1x31REF voltage reference network.
The terminal block pinout is given in Table 8.
Table 8. Terminal Block Pinout
TERMINAL NAME
6.4.4
FUNCTION
EXC–
Negative excitation connected to ground
through installed ADS device
SNS–
Inverting excitation sense input
SNS+
Noninverting excitation sense input
SIG+
Noninverting input
SIG–
Inverting input
EXC+
Positive excitation output (+5V) or positive
reference input
Voltage Reference
The ADS1x31REF is designed to operate either ratiometrically or with an external reference. The two
modes are selected using switch SW7.
In the EXT position, the installed ADS reference inputs are taken from the load cell connectors. In the
+5VA position, the installed ADS positive reference input comes from the 5V analog supply, and the
negative reference input is connected to ground.
After the switch is placed a filtering network that consists of resistors R14 and R15, bulk capacitor C4,
pass-through capacitors C44 and C45, and filtering capacitors C28, C30, and C31.
6.4.5
Input Shorting Jumpers
The shorted-input noise test for the ADS1x31 devices is best performed with both inputs connected to
2.5V. To make this test easy to perform, jumpers J7 and J8 are provided.
Jumper J8 shorts the inputs together. Jumper J7 connects the inverting input to a voltage divider made
from R25 and R26, dividing the power supply by 2. This voltage divider electrically resembles an ideal
bridge sensor.
6.5
USB Interface
The USB interface can be used for firmware download or data communications. Its role in firmware
download is discussed in Section 6.6.
The USB interface consists of USB-to-serial converter U4, a Texas Instruments TUSB3410. This device
incorporates a USB interface module, a microcontroller, and a 16550-type UART. Driver software is
available that causes the device to appear as a serial port on the host PC.
The USB interface is powered separately from the rest of the ADS1x31REF; it takes power from the USB
line, through linear regulator U3.
The serial port side of U4 is connected to the microcontroller UART signals. To keep the power domains
separate, and to keep the USB and microcontroller sides from inadvertently powering each other, the
UART is connected through isolators U8 and U9.
6.6
Programming Connections
The MSP430 can be programmed via the dedicated JTAG port or the serial bootstrap loader.
The JTAG connector is not factory-installed. The footprint is similar to an edge-card pattern, and accepts a
standard dual-row 0.100in header mounted on the side of the board. This header is compatible with
MSP430 parallel-port JTAG adaptors.
22
ADS1131REF and ADS1231REF
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Appendix A
www.ti.com
To allow firmware to be downloaded through USB, U4 is connected to the microcontroller bootstrap loader
pins. The DTR and RTS pins are connected to the RST and TCK inputs on the microcontroller to allow the
serial bootstrap loader to operate. These lines are not isolated; instead, they are switched through SW9,
which also connects USB ground and power to the microcontroller ground and power. Normally this switch
is open; it is only switched on when firmware is to be downloaded through USB. This feature also protects
the microcontroller from unknown states on these pins at power-up.
Appendix A Schematic and Layout
The printed circuit board (PCB) layouts for the top and bottom sides of the ADS1x31REF are shown in
Figure 9 through Figure 12, respectively. Schematics for the ADS1x31REF are shown in Section A.3. The
bill of materials is provided in Table 9.
A.1
Bill of Materials
NOTE: All components should be RoHS compliant. Some part numbers may be either leaded or
RoHS. Verify that purchased components are RoHS compliant.
Table 9. ADS1x31REF Bill of Materials
Item
No
ADS1131
ADS1231
Ref Des
Description
1
1
1
Value
BT1 (+)
9 Volt Battery Clip Female
Keystone
Electronics
594
2
1
1
BT1 (–)
9 Volt Battery Clip Male
Keystone
Electronics
593
3
4
4
22pF
C1, C2, C16,
C17
50V Ceramic Chip Capacitor, ±5%,
C0G
TDK
C1608C0G1H220J
4
4
4
100pF
C29, C30,
C31, C32
16V PPS Film Chip Capacitor, 2%
Panasonic
ECH-U1C101GX5
5
4
4
100pF
C40, C41,
C42, C43
Filter High Frequency, 100pF
Murata
NFM21CC101U1H3D
6
5
5
0.01μF
C5, C11,
C13, C14,
C15
50V Ceramic Chip Capacitor, ±10%,
X7R
TDK
C1608X7R1H103K
7
6
6
0.1μF
C12, C21,
C33 to C36
50V Ceramic Chip Capacitor, ±10%,
X7R
TDK
C1608X7R1H104K
8
2
2
0.1μF
16V PPS Film Chip Capacitor, 2%
Panasonic
ECH-U1C104GX5
9
3
3
1μF
TDK
C1608X7R1C105K
10
5
5
1μF
C37, C38,
C39, C44,
C45
Filter High Frequency, 1.0μF
Murata
NFM21PC105B1C3D
11
6
6
2.2μF
C23 to C28
6.3V Ceramic Chip Capacitor, ±20%,
X5R
TDK
C1608X5R0J225M
12
1
1
4.7μF
C3
16V Ceramic Chip Capacitor,
+80/–20%, Y5V
TDK
C2012Y5V1C475Z
13
4
4
10μF
C8, C18 to
C20
16V Ceramic Chip Capacitor, ± 20%,
X7R
TDK
C3216X7R1C106M
14
1
1
100μF
C4
10V Tantalum Chip Capacitor, ±10%
Kemet
T494D107K010AT
15
1
1
D1
30V, 200mA Schottky Diode
Fairchild
Semiconductor
BAT54
16
1
1
D2
Green LED, SMD
Lumex
SSL-LX3052GD
17
1
1
J1
USB Type 'B' Socket
Mill-Max
897-43-004-90-000000
18
1
1
J2
2.5mm Power Jack
CUI
PJ-102BH
19
0
0
J3
2 X 7 Header
20
1
1
J6
1 X 6 Header
Samtec
TSW-106-07-G-S
21
2
2
J7, J8
1 X 2 Header
Samtec
TSW-102-07-G-S
22
1
1
J4
3.5mm PCB Terminal Block, 4 position
On Shore
Technology
ED555/4DS
C6, C7
C9, C10, C22 16V Ceramic Chip Capacitor, ±10%,
X7R
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Vendor
Part Number
Schematic and Layout
23
Bill of Materials
www.ti.com
Table 9. ADS1x31REF Bill of Materials (continued)
Item
No
ADS1131
ADS1231
23
1
1
Ref Des
Description
J5
3.5mm PCB Terminal Block, 2 position
On Shore
Technology
ED555/2DS
24
1
25
1
1
L1
Ferrite Bead Core, 4A 100MHz
Panasonic
EXC-ML20A390U
1
LCD1
8 Character LCD Display, Reflective
Type
Varitronix
VIM-878-DP-RC-S-LV
26
2
2
0Ω
27
1
1
20Ω
R23, R24
1/10W 5% Chip Resistor
Panasonic
ERJ-3GEY0R00V
R17
1/4W 5% Chip Resistor
Panasonic
28
2
2
ERJ-8GEYJ200V
33Ω
R2, R3
1/10W 5% Chip Resistor
Panasonic
29
4
ERJ-3GEYJ330V
4
100Ω
R12 to R15
1/10W 5% Chip Resistor
Panasonic
30
ERJ-3GEYJ101V
1
1
220Ω
R11
1/10W 5% Chip Resistor
Panasonic
ERJ-3GEYJ221V
31
1
1
1.5kΩ
R1
1/10W 5% Chip Resistor
Panasonic
ERJ-3GEYJ152V
32
8
8
10kΩ
R4-R10, R16
1/10W 5% Chip Resistor
Panasonic
ERJ-3GEYJ103V
33
2
2
20kΩ
R25, R26
1/10W 1% Chip Resistor
Panasonic
ERJ-3EKF2002V
34
2
2
47kΩ
R18, R27
1/10W 5% Chip Resistor
Panasonic
ERJ-3GEYJ473V
35
1
1
200kΩ
R22
Potentiometer 200K Ohm 1/4" SQ
Bourns
3362U-1-204LF
36
3
3
221kΩ
R19 to R21
1/10W 1% Chip Resistor
Panasonic
ERJ-3EKF2213V
37
6
6
SW1 to SW6
Pushbutton Switch
ITT
KSA1M211LFT
38
1
1
SW7
DPDT Slide Switch, Top Actuator
NKK
SS22SDP2
39
1
1
SW8
SPDT Slide Switch, Top Actuator
NKK
SS12SDP2
40
1
1
SW9
4PDT Slide Switch, RA Actuator
E-Switch
EG4208
41
0
0
42
1
1
TP15
Testpoint
Keystone
Electronics
5011
43
1
0
U6
Two-Channel Analog to Digital
Converter
Texas Instruments
ADS1131ID
0
1
Two-Channel Analog to Digital
Converter
Texas Instruments
ADS1231ID
44
1
1
U5
Microcontroller with LCD Drivers
Texas Instruments
MSP430F449IPZ
45
2
2
U2, U3
Linear Voltage Regulator, +3.3V
Texas Instruments
TPS77133DGK
46
1
1
U1
Linear Voltage Regulator, +5V
Texas Instruments
TPS76350DBV
47
1
1
U4
USB to Serial Converter
Texas Instruments
TUSB3410VF
48
2
2
U8, U9
Digital Isolator
Texas Instruments
ISO721D
49
2
2
U7, U10
Inverter, Single Gate
Texas Instruments
SN74LVC1G04DBVR
50
1
1
12MHz
X1
Quartz Crystal SMD
ECS Inc.
ECS-120-20-23B-TR
51
1
1
32.678kHz
X2
Quartz Crystal
Epson
C-002RX
32.7680K-E:PBFREE
52
1
1
N/A
ADS1x31 REF PWB
Texas Instruments
6517107
53
4
4
N/A
1/4" x .75 hex 4-40 Brass Threaded
Standoff
Keystone
Electronics
1656A
54
4
4
N/A
Phillips Machine Screw, 1/2" 4-40
Building Fasteners PMSSS 440 0050 PH
55
2
2
N/A
Shorting Block
Samtec
24
Schematic and Layout
Value
Vendor
Part Number
TP1 to TP14, Not Installed
TP16 to TP18
SNT-100-BK-G-H
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
PCB Layout
www.ti.com
A.2
PCB Layout
Figure 9. ADS1x31REF PCB—Top Side
Figure 10. ADS1x31REF PCB—Layer 1
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Schematic and Layout
25
PCB Layout
www.ti.com
Figure 11. ADS1x31REF PCB—Layer 2
Figure 12. ADS1x31REF PCB—Bottom Side
26
Schematic and Layout
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Schematics
www.ti.com
A.3
Schematics
C30
TP13
100pF
TP11
EXTCLK
C27
2.2uF
+5VA
3
2
13
10
9
7
8
5
6
12
11
C28
2.2uF
C45
C31
C42
TP15
GND
+5VA
C38
TP3
+5V
C39
R24
MUR_NFM21PC105F1C3D 0
D1
CUI-STACK PJ-102BH
5
VIN
VOUT
ENABLE
GND
NR/ADJUST
C8
10uF
4
R26
20K
+5VA
1
2
3
4
5
6
+5VA
HEADER-6
+5V
U1
1
3
2
R23
0
100pF
20K
EXC+
EXCSNS+
SIG+
SIGEXCSNSEXC-
BT1
J2
C7
0.1uF
C29
R25
J6
9V
J8
1
PWDN
PDWN
TP12
SPEED
SPEED
TP10
SCLK
SCLK
DOUT
TP9
100pF
MUR_NFM21PC105F1C3D
J7
DOUT
SW-DPDT
100
C6 0.1uF
C43
TP6
+5VA
2
C41
SW7
C32
ADS1231ID
ADS1131ID (GND PIN 3)
C40
VREF+
100
100pF
1
R27
47K
DVDD
AVDD
SPEED
VREFP
SCLK
VREFN
DRDY/DOUT AINP
PDWN
AINN
CAP
CLKIN
CAP
GND
PSW
GND
R14
TP14
C4
100uF VREFR15
2.2uF
U6
1
4
15
16
14
C44
2
+3.3VD C26
J4
J5
OST_ED555/4DS OST_ED555/2DS
C19
10uF
TPS76350DBV
C11
0.01uF
TP4
+3.3VD
+5VA
C9
1uF
+3.3VD
U2
5
6
3
4
IN
OUT
IN
OUT
EN FB/SENSE
GND
RESET
7
8
1
2
RST
C20
10uF
TPS77133DGK
Figure 13. ADS1x31REF Schematic—ADC
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Schematic and Layout
27
Schematics
www.ti.com
+3.3VD
SW2
SW3
RANGE
SW4
TARE
SW5
CAL
CONFIG
C13
C14
C15
C5
0.01uF
R19
0.01uF
R20
0.01uF
R21
0.01uF
221K
221K
221K
R8
10K
R9
10K
+3.3VD
SIMO0
R22
200K
PDWN
C23
2.2uF
COM(3)
COM(2)
COM(1)
COM(0)
S(39)
R7
10K
DOUT
SCLK
SPEED
TP18
TP8
MCURX MCUTX
10K R10
TP7
DNP
75
74
73
72
71
70
69
68
67
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
MCURX
MCUTX
J3
2
4
6
8
10
12
14
TDO/TDI
TDI/CLK
TMS
TCK
1
3
5
7
9
11
13
C25
2.2uF
RST
+3.3VD
S(7)
S(8)
S(11)
S(12)
S(15)
S(16)
S(19)
S(20)
S(23)
S(24)
S(27)
S(28)
S(31)
S(32)
S(35)
S(36)
COM(0)
COM(1)
S(38)
S(37)
S(36)
S(35)
S(34)
S(33)
S(32)
S(31)
S(30)
S(29)
S(28)
S(27)
S(26)
S(25)
S(24)
S(23)
S(22)
S(21)
S(20)
S(19)
S(18)
S(17)
S(16)
S(15)
S(14)
LCD1
LCD_DISPLAY
U5
MSP430F449IPZ
S(5)
S(6)
S(7)
S(8)
S(9)
S(10)
S(11)
S(12)
S(13)
R18
RESET
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
HEADER-7X2
SW6
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
DVCC1
P6.3/A3
P6.4/A4
P6.5/A5
P6.6/A6
P6.7/A7/SVSIN
VREF+
XIN
XOUT
VeREF+
VREF-/VeREFP5.1/S0
P5.0/S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
R13 100
R12 100
+3.3VD
P4.3/SIMO1/S38
P4.4/SOMI1/S37
P4.5/UCLK1/S36
P4.6/S35
P4.7/S34
S33
S32
S31
S30
S29
S28
S27
S26
S25
S24
S23
S22
S21
S20
S19
S18
S17
S16
S15
S14
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
P2.3/TB2
P2.2/TB1
P2.1/TB0
P2.0/TA2
P1.7/CA1
P1.6/CA0
P1.5/TACLK/ACLK
P1.4/TBCLK/SMCLK
P1.3/TBOUTH/SVSOUT
P1.2/TA1
P1.1/TA0/MCLK
P1.0/TA0
XT2OUT
XT2IN
TDO/TDI
TDI/TCLK
TMS
TCK
RST/NMI
P6.0/A0
P6.1/A1
P6.2/A2
AVSS
DVSS1
AVCC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
76
77
78
79
80
81
82
83
84
85
86
BSLRX
87
BSLTX
88
89
90
91
92
93
94
95
96
97
98
99
+3.3VD
100
DOUT
S(5)
S(6)
S(9)
S(10)
S(13)
S(14)
S(17)
S(18)
S(21)
S(22)
S(25)
S(26)
S(29)
S(30)
S(33)
S(34)
COM(3)
COM(2)
R16
10K
TP5
P1.4/SMCLK
RST
TCK
P2.4/UTXD0
P2.5/URXD0
P2.6/CAOUT
P2.7/ADC12CLK
P3.0/STE0
P3.1/SIMO0
P3.2/SOMI0
P3.3/UCLK0
P3.4/TB3
P3.5/TB4
P3.6/TB5
P3.7/TB6
P4.0/UTXD1
P4.1/URXD1
DVSS2
DVCC2
P5.7/R33
P5.6/R23
P5.5/R13
R03
P5.4/COM3
P5.3/COM2
P5.2/COM1
COM0
P4.2/STE1/S39
+3.3VD
SW8
NKK_SS12SDP2
47K
C24
2.2uF
X2
EPS_C-002RX 32.7680K-A:PBFREE
Figure 14. ADS1x31REF Schematic—MCU
C33
TP16
RX
USB3.3V
1
3
2
4
R5
TP17
TX
C22
C34
R2
33
R3
33
C16
22pF
C17
22pF
3
25
4
VCC
VCC
CTS
RTS
RI/CP
DTR
DSR
DCD
PUR
DP
DM
GND
GND
GND
TEST0
TEST1
R17
20
VCC2 VCC1
OUT VCC1
GND2
IN
GND2 GND1
C36
0.1uF
MCUTX
C12
U10
4
SN74LVC1G04DBV
PROGRAMMING MODE
SW9
23
24
USB3.3V
U7
2
TCK
C21
0.1uF
4
RST
SN74LVC1G04DBV
+5VA
32
31
30
29
4
3
2
1
USB5V
+5V
SW1
ESW_EG4208
USB RESET
USB5V
USB SLAVE CONN
C37
MUR_NFM21PC105F1C3D
C3
4.7uF
USB3.3V
U3
5
6
3
4
IN
OUT
IN
OUT
EN FB/SENSE
GND
RESET
7
8
1
2
R6
C18
10uF
TP2
3.3V_USB
GND
D+
DVCC
+3.3VD
1
3
2
4
0.1uF
2
TUSB3410VF
1
9
2
12
J1
USB3.3V
19 RX
17 TX
USB3.3V
13
20 RTS
16
21 DTR
14
15
5
SOUT/IR_SOUT
SIN/IR_SIN
MCURX
ISO721D
3
VDD
SCL
SDA
CLKOUT
8
6
7
5
U9
8
6
7
5
3
R1
1.5K
8
18
28
X2
X1/CLKI
5
5
6
7
FERRITE BEAD
L1
1uF
P3.0
P3.1
P3.3
P3.4
22
C2
22pF
12MHz
USB3.3V
0.1uF
U4
26
27
VREGEN
RESET
SUSPEND
WAKEUP
C1
22pF
10
TP1
USB_CLK
11
10K 10K
X1
VCC1 VCC2
VCC1 OUT
IN
GND2
GND1 GND2
C35
0.1uF
ISO721D
USB3.3V
R4
+3.3VD
U8
0.1uF
10K
R11
220
C10
1uF
TPS77133DGK
D2
GREEN
Figure 15. ADS1x31REF Schematic—USB
28
Schematic and Layout
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Revision History
www.ti.com
Revision History
Changes from Original (July, 2010) to A Revision .......................................................................................................... Page
•
•
•
•
•
•
Deleted references to Offset Calibration in Table 2 .................................................................................. 9
Removed information on Offset Calibration from Section 2.4.1 .................................................................. 10
Deleted information about Offset Calibration from Table 5 ........................................................................ 13
Removed information about Offset Calibration from Section 3.4.1 ............................................................... 13
Updated Table 6 to remove Offset Calibration information ........................................................................ 19
Deleted Offset Calibration section from Command Reference section .......................................................... 19
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
SBAU175A – July 2010 – Revised August 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Revision History
29
Evaluation Board/Kit Important Notice
Texas Instruments (TI) provides the enclosed product(s) under the following conditions:
This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION
PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the
product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are
not intended to be complete in terms of required design-, marketing-, and/or manufacturing-related protective considerations,
including product safety and environmental measures typically found in end products that incorporate such semiconductor
components or circuit boards. This evaluation board/kit does not fall within the scope of the European Union directives regarding
electromagnetic compatibility, restricted substances (RoHS), recycling (WEEE), FCC, CE or UL, and therefore may not meet the
technical requirements of these directives or other related directives.
Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30
days from the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY
SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all
claims arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to
take any and all appropriate precautions with regard to electrostatic discharge.
EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive.
TI assumes no liability for applications assistance, customer product design, software performance, or infringement of
patents or services described herein.
Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the
product. This notice contains important safety information about temperatures and voltages. For additional information on TI’s
environmental and/or safety programs, please contact the TI application engineer or visit www.ti.com/esh.
No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used.
FCC Warning
This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION
PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and
can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15
of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this
equipment in other environments may cause interference with radio communications, in which case the user at his own expense
will be required to take whatever measures may be required to correct this interference.
EVM Warnings and Restrictions
It is important to operate this EVM within the input voltage range of 0V to +9V and the output voltage range of 0V to 5V.
Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are
questions concerning the input range, please contact a TI field representative prior to connecting the input power.
Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the
EVM. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load
specification, please contact a TI field representative.
During normal operation, some circuit components may have case temperatures greater than +30°C. The EVM is designed to
operate properly with certain components above +50°C as long as the input and output ranges are maintained. These components
include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of
devices can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near
these devices during operation, please be aware that these devices may be very warm to the touch.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Audio
www.ti.com/audio
Communications and Telecom www.ti.com/communications
Amplifiers
amplifier.ti.com
Computers and Peripherals
www.ti.com/computers
Data Converters
dataconverter.ti.com
Consumer Electronics
www.ti.com/consumer-apps
DLP® Products
www.dlp.com
Energy and Lighting
www.ti.com/energy
DSP
dsp.ti.com
Industrial
www.ti.com/industrial
Clocks and Timers
www.ti.com/clocks
Medical
www.ti.com/medical
Interface
interface.ti.com
Security
www.ti.com/security
Logic
logic.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Power Mgmt
power.ti.com
Transportation and
Automotive
www.ti.com/automotive
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
Wireless
www.ti.com/wireless-apps
RF/IF and ZigBee® Solutions
www.ti.com/lprf
TI E2E Community Home Page
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
Similar pages