ETC2 GHA500F-12 Ac-dc power supplies medical type Datasheet

Ordering information
AC-DC Power Supplies Medical type
GHA300F
GH
1
A
2
300
3
F
4
Recommended EMI/EMC Filter
EAC-10-472
R
High voltage pulse noise type : EAP series
Low leakage current type : EAM series
Photo is an image of the appearance.
May differ from the actual product.
Information the Home page is the latest.
*The EMI/EMC Filter is recommended to
connect with several devices.
-OO -O
5
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *6
T3 : mounting hole M3
J1 : VH(J.S.T.)connector type
R3 : with Subfeatures
(5VAUX,12VAUX,Remote,
Power good)
Specification is changed at
option, refer to Instruction
manual.
【Cautions】
・Forced air cooling is required for the maximum output power. Please see instruction manual.
・This power supply requires mounting on metal standoffs 5mm in height. Insulation sheet is required if standoff is not used or less than 5mm clearance is needed.
・Avoid applying stress to surface mount components.
・De-rating is required if the applied input voltage is 90-115VAC.
・The electrolytic capacitor has limited life span which is very much dependent on the actual operating conditions.
・Operating in the presense of chemical vapors or harsh environmnet can affect the power supply life expectnacy.
・Please make sure to read the instruction manual carefully before using this product.
It should be in the "Instruction Manual" not spec sheet.
MODEL
MAX OUTPUT WATTAGE[W]
Forced air at 50C
at 40C
DC OUTPUT
Convection
at 50C
GHA300F-12
300
12V 25A
12V 8.4A
12V 4.5A
GHA300F-24
300
24V 12.5A
24V 4.2A
24V 2.2A
GHA300F-48
302.4
48V 6.3A
48V 2.1A
48V 1.1A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 120V
ACIN 230V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
GHA
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 120V
ACIN 230V
POWER FACTOR
ACIN 120V
(Io=100%) ACIN 230V
ACIN 120V
INRUSH CURRENT[A]
ACIN 230V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
Forced air
CURRENT[A]
Convection
LINE REGULATION[mV] *4
LOAD REGULATION[mV] *4
0 to +50C
RIPPLE[mVp-p] *1
-20 to 0C
0 to +50C
RIPPLE NOISE[mVp-p]*1
-20 to 0C
0 to +50C
TEMPERATURE REGULATION[mV]
-20 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
AUX1 (12V1A)
AUX2 (5V1A)
REMOTE ON/OFF
PowerGood
INPUT-OUTPUT-RC-AUX *7
INPUT-FG
*7
OUTPUT-RC-AUX-FG
*7
OUTPUT-RC-AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
GHA300F-12
GHA300F-24
GHA300F-48
AC90 - 264 1f (output derating is required at AC90V -115V *3)
3.3typ
1.8typ
50 / 60 (47 - 63)
89typ
90typ
90typ
91typ
92typ
92typ
0.95typ
0.90typ
20typ (Io=100%) (At cold start) (Ta=25C)
40typ (Io=100%) (At cold start) (Ta=25C)
0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1)
12
24
48
25
12.5
6.3
4.5
2.2
1.1
48max
96max
192max
100max
150max
240max
240max
240max
300max
320max
320max
400max
300max
300max
480max
360max
360max
500max
120max
240max
480max
150max
290max
600max
48max
96max
192max
500typ (ACIN 120V, Io=100%)
16typ (ACIN 120V, Io=100%)
10.80 to 13.20
21.60 to 26.40
43.20 to 52.80
12.00 to 12.48
24.00 to 24.96
48.00 to 49.92
Works over 105% of rating and recovers automatically
13.80 to 16.80
27.60 to 33.60
55.20 to 67.20
Optional
Optional
Optional
Optional
AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-20 to +70C, 20 - 90%RH (Non condensing)
-30 to +75C, 20 - 90%RH (Non condensing)
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, ANSI/AMII ES60601-1, C-UL, EN60950-1, EN60601-1
Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (class A) *5
76.2X35X127mm [3.0X1.4X5.0 inches] (WXHXD) / 400g max
Convection, Forced air (Require external fan)
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from
output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with
the input voltage held constant at the rated input/output.
*3 Derating is required.
*4 Please contact us about dynamic load and input response.
GHA-2
*5
*6
*7
*
*
*
6
Please contact us about another class.
Specification is changed at option, refer to Instruction Manual.
Applicable when AUX and remote control (optional) is added.
To meet the specifications. Do not operate over-loaded condition.
Sound noise may be generated by power supply in case of pulse load.
Parallel operation is not possible.
GHA300F
Features
-High Power density:14.3W/inch3
-High efficiency 92% typ (Input Voltage 230V, Output Voltage 24V)
- 3"X 5"standard footprint
-Fits 1U applications
-Industrial and Medical safety approvals
-Low leakage current
-With Remote On/Off (Optional)
-With AUX1 (5V), AUX2 (12V) (Optional)
-No minimum load is required
Block diagram
AC IN 90 - 264V
FUSE
250V10A X2
BOOSTER
INDUCTER
NOISE
FILTER
CURRENT
SENSING
INRUSH
CURRENT
LIMIT
RECTIFIER
INVERTER
FG
RECTIFIER
AND
FILTER
CONTROL
TRANSFORMER
INVERTER
CURRENT
SENSING
INTERNAL
RECTIFIER
AND
FILTER
AUX1(12V 1A)
RECTIFIER
AND
FILTER
DC OUT
CONTROL
REGULATOR
Photocoupler
OVER
VOLTAGE
PROTECTION
Photocoupler
PG(POWER GOOD)
CONTROL
RC(REMOTE ON/OFF)
TRANSFORMER
RECTIFIER
AND
FILTER
AUX2(5V 1A)
External view
4-f3.4(with Mounting Holes M3)
Mounting Holes
115.6 ±0.5
5.7
[4.55]
[0.22]
CN101
TB501
1
AC(L)
2
CN501
7
17.0
FG
[0.22]
[0.71]
18.0
1
119.7
[1.50]
CN101
AC(N)
38.0
3
CN501
(Optional)
CN101
(Optional)
CN501
(Optional)
[0.67]
[2.55]
OUTPUT(-)
with Subfeatures(Optional)
124.1
Voltage adjust
[4.89]
Terminal
A-41671-A03A197-2 09-50-8031
08-50-0105
08-65-0114
087831-0820
51110-0851
50394-8051
B2P3-VH
VHR-3N
SVH-21T-P1.1
B8B-PHDSS
PHDR-08VS
SPHD-002T-P0.5
Mfr
170603-2
Tyco Electronics
<Pin Assignments>
<CN101>
Pin No.
Input
1
AC(L)
2
[0.96]
24.5
[0.65]
16.5
[1.38]
3
¶
¶
¶
¶
¶
Terminal
-
[5.00]
Tolerance ±1 [±0.04]
Weight : 400g max
There is a total of four attachment holes.
This power supply requires mounting on metal standoffs 5mm in height.
(Insulating sheet is required if you do not use a spacer).
Dimensions in mm, [ ]=inches
Screw tightening torque : (TB501, 502) : 1.5N-m max
Mounting toque : 0.6N-m max
Avoid contact between TB501 and 502 wiring with mounting parts.
Option : -J1 : (J.S.T) connector type. Refer to Instruction Manual 5.
MOLEX
Mating connector
250 Series
127.0
Name plate
¶
¶
¶
¶
Mfr
J.S.T.
FG
-
[4.71]
35
[3.00]
TB502
8
5.7
76.2
64.8 ±0.5
OUTPUT(+)
Mating
connector
I/OConnector
AC(N)
<CN501(Optional)>
Pin No.
Function
1
AUX1 : AUX1(12V1A)
2
AUX1G : AUX1(GND)
3
RC1
: REMOTE ON/OFF
4
RCG
: REMOTE ON/OFF(GND)
5
PG
: Power good
6
PGG
: Power good(GND)
7
AUX2 : AUX2(5V1A)
8
AUX2G : AUX2(GND)
2
1
8
7
CN501
GHA-3
GHA
Ordering information
AC-DC Power Supplies Medical type
GHA500F
GH
1
A
2
500
3
F
4
Recommended EMI/EMC Filter
EAC-10-472
R
High voltage pulse noise type : EAP series
Low leakage current type : EAM series
Photo is an image of the appearance.
May differ from the actual product.
Information the Home page is the latest.
*The EMI/EMC Filter is recommended to
connect with several devices.
【Cautions】
・Forced air cooling is required for the maximum output power. Please see instruction manual.
・Avoid applying stress to surface mount components.
・De-rating is required if the applied input voltage is 90-115VAC.
・The electrolytic capacitor has limited life span which is very much dependent on the actual operating conditions.
・Operating in the presense of chemical vapors or harsh environmnet can affect the power supply life expectnacy.
・Please make sure to read the instruction manual carefully before using this product.
It should be in the "Instruction Manual" not spec sheet.
MODEL
MAX OUTPUT WATTAGE[W]
Forced air at 50C
Convection at 40C
DC OUTPUT
at 50C
conduction at 0C
cooling
at 50C
GHA500F-12
500.8
12V 41.7A
12V 12.5A
12V 9.2A
12V 30.0A
12V 16.7A
GHA500F-15
501
15V 33.4A
15V 10.0A
15V 7.4A
15V 24.0A
15V 13.4A
GHA500F-24
504
24V 21.0A
24V 6.3A
24V 4.6A
24V 15.0A
24V 8.4A
-OO -O
5
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *6
T3 : mounting hole M3
J1 : VH(J.S.T.)connector type
R3 : with Subfeatures
(5VAUX,12VAUX,Remote,
Power good)
P : Pallarel Operation
Specification is changed at
option, refer to Instruction
manual.
GHA500F-48
504
48V 10.5A
48V 3.2A
48V 2.3A
48V 7.5A
48V 4.2A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 120V
ACIN 230V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
GHA
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 120V
ACIN 230V
POWER FACTOR
ACIN 120V
(Io=100%) ACIN 230V
ACIN 120V
INRUSH CURRENT[A]
ACIN 230V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
Forced air
CURRENT[A]
Convection
conduction cooling
LINE REGULATION[mV] *4
LOAD REGULATION[mV] *4
0 to +50C
RIPPLE[mVp-p] *1
-20 - 0C
0 to +50C
RIPPLE NOISE[mVp-p]*1
-20 - 0C
0 to +50C
TEMPERATURE REGULATION[mV]
-20 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
AUX1 (12V1A)
AUX2 (5V1A)
REMOTE ON/OFF
PowerGood
INPUT-OUTPUT-RC-AUX *7
INPUT-FG
*7
OUTPUT-RC-AUX-FG
*7
OUTPUT-RC-AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
GHA500F-12
GHA500F-15
GHA500F-24
GHA500F-48
AC90 - 264 1f (output derating is required at AC90V -115V *3)
5.4typ
2.9typ
50 / 60 (47 - 63)
88typ
90typ
90typ
90typ
90typ
92typ
92typ
92typ
0.95typ
0.90typ
20typ (Io=100%) (At cold start) (Ta=25C)
40typ (Io=100%) (At cold start) (Ta=25C)
0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1)
12
15
24
48
41.7
33.4
21.0
10.5
9.2
7.4
4.6
2.3
16.7
13.4
8.4
4.2
48max
60max
96max
192max
100max
120max
150max
240max
240max
240max
240max
300max
320max
320max
320max
400max
300max
300max
300max
480max
360max
360max
360max
500max
120max
120max
240max
480max
150max
150max
290max
600max
48max
60max
96max
192max
500typ (ACIN 120V, Io=100%)
16typ (ACIN 120V, Io=100%)
10.80 to 13.20
13.50 to 16.50
21.60 to 26.40
43.20 to 52.80
12.00 to 12.48
15.00 to 15.30
24.00 to 24.96
48.00 to 49.92
Works over 105% of rating and recovers automatically
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
55.20 to 67.20
Optional
Optional
Optional
Optional
AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-20 to +80C, 20 - 90%RH (Non condensing)
-30 to +80C, 20 - 90%RH (Non condensing)
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, ANSI/AMII ES60601-1, C-UL, EN60950-1, EN60601-1
Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (class A) *5
76.2X35X127mm [3.0X1.4X5.0 inches] (WXHXD) / 420g max
Convection, Forced air (Require external fan), Conduction cooling
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from
output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with
the input voltage held constant at the rated input/output.
*3 Derating is required.
*4 Please contact us about dynamic load and input response.
GHA-4
*5
*6
*7
*
*
*
6
Please contact us about another class.
Specification is changed at option, refer to Instruction Manual.
Applicable when AUX and remote control (optional) is added.
To meet the specifications. Do not operate over-loaded condition.
Sound noise may be generated by power supply in case of pulse load.
Parallel operation is not possible.
GHA500F
Features
-Wattage 500W max
-High Power density:24.1W/inch3
-High efficiency 92% typ (Input Voltage 230V,Output Voltage 24V)
-Conduction cooling
- 3"X 5"standard footprint
-Fits 1U applications
-Industrial and Medical safety approvals
-Low leakage current
-With Remote On/Off (Optional)
-With AUX1 (5V), AUX2 (12V) (Optional)
-No minimum load is required
Block diagram
AC IN 90 - 264V
FUSE
250V10A X2
BOOSTER
INDUCTER
NOISE
FILTER
CURRENT
SENSING
INRUSH
CURRENT
LIMIT
RECTIFIER
INVERTER
FG
RECTIFIER
AND
FILTER
CONTROL
TRANSFORMER
INVERTER
CURRENT
SENSING
INTERNAL
RECTIFIER
AND
FILTER
AUX1(12V 1A)
RECTIFIER
AND
FILTER
DC OUT
CONTROL
REGULATOR
Photocoupler
OVER
VOLTAGE
PROTECTION
Photocoupler
PG(POWER GOOD)
CONTROL
RC(REMOTE ON/OFF)
TRANSFORMER
RECTIFIER
AND
FILTER
AUX2(5V 1A)
External view
4-f3.4(with Mounting Holes M3)
Mounting Holes
115.6 ±0.5
5.7
[4.55]
[0.22]
CN101
TB501
CN101
AC(N)
2
CN501
(Optional)
CN101
(Optional)
CN501
(Optional)
-
with Subfeatures(Optional)
[4.71]
124.1
Terminal
A-41671-A03A197-2 09-50-8031
08-50-0105
08-65-0114
087831-0820
51110-0851
50394-8051
B2P3-VH
VHR-3N
SVH-21T-P1.1
B8B-PHDSS
PHDR-08VS
SPHD-002T-P0.5
Voltage adjust
[4.89]
127.0
[5.00]
Mfr
MOLEX
J.S.T.
FG
[0.67]
17.0
119.7
[1.50]
38.0
7
AC(L)
FG
[0.22]
[0.71]
18.0
1
CN501
8
1
Mating connector
Terminal
Mfr
-
170603-2
Tyco Electronics
250 Series
<Pin Assignments>
<CN101>
Pin No.
Input
1
AC(L)
2
Name plate
3
AC(N)
GHA
Tolerance ±1 [±0.04]
Weight : 420g max
There is a total of four attachment holes.
Base Plate : Aluminum
Dimensions in mm, [ ]=inches
Screw tightening torque : (TB501, 502) : 1.5N-m max
Mounting toque : 0.6N-m max
Avoid contact between TB501 and 502 wiring with mounting parts.
Option : -J1 : (J.S.T) connector type. Refer to Instruction Manual 5.
[0.96]
24.5
16.5
¶
¶
¶
¶
¶
¶
¶
¶
¶
[0.65]
<CN501(Optional)>
[1.38]
35
[3.00]
OUTPUT(-)
[2.55]
64.8 ±0.5
TB502
3
5.7
76.2
OUTPUT(+)
Mating
connector
I/OConnector
Pin No.
Function
1
AUX1 : AUX1(12V1A)
2
AUX1G : AUX1(GND)
3
RC1
: REMOTE ON/OFF
4
RCG
: REMOTE ON/OFF(GND)
5
PG
: Power good
6
PGG
: Power good(GND)
7
AUX2 : AUX2(5V1A)
8
AUX2G : AUX2(GND)
2
1
8
7
CN501
GHA-5