Ordering information AC-DC Power Supplies Medical type GHA300F GH 1 A 2 300 3 F 4 Recommended EMI/EMC Filter EAC-10-472 R High voltage pulse noise type : EAP series Low leakage current type : EAM series Photo is an image of the appearance. May differ from the actual product. Information the Home page is the latest. *The EMI/EMC Filter is recommended to connect with several devices. -OO -O 5 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 T3 : mounting hole M3 J1 : VH(J.S.T.)connector type R3 : with Subfeatures (5VAUX,12VAUX,Remote, Power good) Specification is changed at option, refer to Instruction manual. 【Cautions】 ・Forced air cooling is required for the maximum output power. Please see instruction manual. ・This power supply requires mounting on metal standoffs 5mm in height. Insulation sheet is required if standoff is not used or less than 5mm clearance is needed. ・Avoid applying stress to surface mount components. ・De-rating is required if the applied input voltage is 90-115VAC. ・The electrolytic capacitor has limited life span which is very much dependent on the actual operating conditions. ・Operating in the presense of chemical vapors or harsh environmnet can affect the power supply life expectnacy. ・Please make sure to read the instruction manual carefully before using this product. It should be in the "Instruction Manual" not spec sheet. MODEL MAX OUTPUT WATTAGE[W] Forced air at 50C at 40C DC OUTPUT Convection at 50C GHA300F-12 300 12V 25A 12V 8.4A 12V 4.5A GHA300F-24 300 24V 12.5A 24V 4.2A 24V 2.2A GHA300F-48 302.4 48V 6.3A 48V 2.1A 48V 1.1A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 120V ACIN 230V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT GHA SAFETY AND NOISE REGULATIONS OTHERS ACIN 120V ACIN 230V POWER FACTOR ACIN 120V (Io=100%) ACIN 230V ACIN 120V INRUSH CURRENT[A] ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] Forced air CURRENT[A] Convection LINE REGULATION[mV] *4 LOAD REGULATION[mV] *4 0 to +50C RIPPLE[mVp-p] *1 -20 to 0C 0 to +50C RIPPLE NOISE[mVp-p]*1 -20 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] AUX1 (12V1A) AUX2 (5V1A) REMOTE ON/OFF PowerGood INPUT-OUTPUT-RC-AUX *7 INPUT-FG *7 OUTPUT-RC-AUX-FG *7 OUTPUT-RC-AUX OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] GHA300F-12 GHA300F-24 GHA300F-48 AC90 - 264 1f (output derating is required at AC90V -115V *3) 3.3typ 1.8typ 50 / 60 (47 - 63) 89typ 90typ 90typ 91typ 92typ 92typ 0.95typ 0.90typ 20typ (Io=100%) (At cold start) (Ta=25C) 40typ (Io=100%) (At cold start) (Ta=25C) 0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1) 12 24 48 25 12.5 6.3 4.5 2.2 1.1 48max 96max 192max 100max 150max 240max 240max 240max 300max 320max 320max 400max 300max 300max 480max 360max 360max 500max 120max 240max 480max 150max 290max 600max 48max 96max 192max 500typ (ACIN 120V, Io=100%) 16typ (ACIN 120V, Io=100%) 10.80 to 13.20 21.60 to 26.40 43.20 to 52.80 12.00 to 12.48 24.00 to 24.96 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 27.60 to 33.60 55.20 to 67.20 Optional Optional Optional Optional AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -20 to +70C, 20 - 90%RH (Non condensing) -30 to +75C, 20 - 90%RH (Non condensing) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, ANSI/AMII ES60601-1, C-UL, EN60950-1, EN60601-1 Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (class A) *5 76.2X35X127mm [3.0X1.4X5.0 inches] (WXHXD) / 400g max Convection, Forced air (Require external fan) *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 Please contact us about dynamic load and input response. GHA-2 *5 *6 *7 * * * 6 Please contact us about another class. Specification is changed at option, refer to Instruction Manual. Applicable when AUX and remote control (optional) is added. To meet the specifications. Do not operate over-loaded condition. Sound noise may be generated by power supply in case of pulse load. Parallel operation is not possible. GHA300F Features -High Power density:14.3W/inch3 -High efficiency 92% typ (Input Voltage 230V, Output Voltage 24V) - 3"X 5"standard footprint -Fits 1U applications -Industrial and Medical safety approvals -Low leakage current -With Remote On/Off (Optional) -With AUX1 (5V), AUX2 (12V) (Optional) -No minimum load is required Block diagram AC IN 90 - 264V FUSE 250V10A X2 BOOSTER INDUCTER NOISE FILTER CURRENT SENSING INRUSH CURRENT LIMIT RECTIFIER INVERTER FG RECTIFIER AND FILTER CONTROL TRANSFORMER INVERTER CURRENT SENSING INTERNAL RECTIFIER AND FILTER AUX1(12V 1A) RECTIFIER AND FILTER DC OUT CONTROL REGULATOR Photocoupler OVER VOLTAGE PROTECTION Photocoupler PG(POWER GOOD) CONTROL RC(REMOTE ON/OFF) TRANSFORMER RECTIFIER AND FILTER AUX2(5V 1A) External view 4-f3.4(with Mounting Holes M3) Mounting Holes 115.6 ±0.5 5.7 [4.55] [0.22] CN101 TB501 1 AC(L) 2 CN501 7 17.0 FG [0.22] [0.71] 18.0 1 119.7 [1.50] CN101 AC(N) 38.0 3 CN501 (Optional) CN101 (Optional) CN501 (Optional) [0.67] [2.55] OUTPUT(-) with Subfeatures(Optional) 124.1 Voltage adjust [4.89] Terminal A-41671-A03A197-2 09-50-8031 08-50-0105 08-65-0114 087831-0820 51110-0851 50394-8051 B2P3-VH VHR-3N SVH-21T-P1.1 B8B-PHDSS PHDR-08VS SPHD-002T-P0.5 Mfr 170603-2 Tyco Electronics <Pin Assignments> <CN101> Pin No. Input 1 AC(L) 2 [0.96] 24.5 [0.65] 16.5 [1.38] 3 ¶ ¶ ¶ ¶ ¶ Terminal - [5.00] Tolerance ±1 [±0.04] Weight : 400g max There is a total of four attachment holes. This power supply requires mounting on metal standoffs 5mm in height. (Insulating sheet is required if you do not use a spacer). Dimensions in mm, [ ]=inches Screw tightening torque : (TB501, 502) : 1.5N-m max Mounting toque : 0.6N-m max Avoid contact between TB501 and 502 wiring with mounting parts. Option : -J1 : (J.S.T) connector type. Refer to Instruction Manual 5. MOLEX Mating connector 250 Series 127.0 Name plate ¶ ¶ ¶ ¶ Mfr J.S.T. FG - [4.71] 35 [3.00] TB502 8 5.7 76.2 64.8 ±0.5 OUTPUT(+) Mating connector I/OConnector AC(N) <CN501(Optional)> Pin No. Function 1 AUX1 : AUX1(12V1A) 2 AUX1G : AUX1(GND) 3 RC1 : REMOTE ON/OFF 4 RCG : REMOTE ON/OFF(GND) 5 PG : Power good 6 PGG : Power good(GND) 7 AUX2 : AUX2(5V1A) 8 AUX2G : AUX2(GND) 2 1 8 7 CN501 GHA-3 GHA Ordering information AC-DC Power Supplies Medical type GHA500F GH 1 A 2 500 3 F 4 Recommended EMI/EMC Filter EAC-10-472 R High voltage pulse noise type : EAP series Low leakage current type : EAM series Photo is an image of the appearance. May differ from the actual product. Information the Home page is the latest. *The EMI/EMC Filter is recommended to connect with several devices. 【Cautions】 ・Forced air cooling is required for the maximum output power. Please see instruction manual. ・Avoid applying stress to surface mount components. ・De-rating is required if the applied input voltage is 90-115VAC. ・The electrolytic capacitor has limited life span which is very much dependent on the actual operating conditions. ・Operating in the presense of chemical vapors or harsh environmnet can affect the power supply life expectnacy. ・Please make sure to read the instruction manual carefully before using this product. It should be in the "Instruction Manual" not spec sheet. MODEL MAX OUTPUT WATTAGE[W] Forced air at 50C Convection at 40C DC OUTPUT at 50C conduction at 0C cooling at 50C GHA500F-12 500.8 12V 41.7A 12V 12.5A 12V 9.2A 12V 30.0A 12V 16.7A GHA500F-15 501 15V 33.4A 15V 10.0A 15V 7.4A 15V 24.0A 15V 13.4A GHA500F-24 504 24V 21.0A 24V 6.3A 24V 4.6A 24V 15.0A 24V 8.4A -OO -O 5 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 T3 : mounting hole M3 J1 : VH(J.S.T.)connector type R3 : with Subfeatures (5VAUX,12VAUX,Remote, Power good) P : Pallarel Operation Specification is changed at option, refer to Instruction manual. GHA500F-48 504 48V 10.5A 48V 3.2A 48V 2.3A 48V 7.5A 48V 4.2A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 120V ACIN 230V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION GHA ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 120V ACIN 230V POWER FACTOR ACIN 120V (Io=100%) ACIN 230V ACIN 120V INRUSH CURRENT[A] ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] Forced air CURRENT[A] Convection conduction cooling LINE REGULATION[mV] *4 LOAD REGULATION[mV] *4 0 to +50C RIPPLE[mVp-p] *1 -20 - 0C 0 to +50C RIPPLE NOISE[mVp-p]*1 -20 - 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] AUX1 (12V1A) AUX2 (5V1A) REMOTE ON/OFF PowerGood INPUT-OUTPUT-RC-AUX *7 INPUT-FG *7 OUTPUT-RC-AUX-FG *7 OUTPUT-RC-AUX OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] GHA500F-12 GHA500F-15 GHA500F-24 GHA500F-48 AC90 - 264 1f (output derating is required at AC90V -115V *3) 5.4typ 2.9typ 50 / 60 (47 - 63) 88typ 90typ 90typ 90typ 90typ 92typ 92typ 92typ 0.95typ 0.90typ 20typ (Io=100%) (At cold start) (Ta=25C) 40typ (Io=100%) (At cold start) (Ta=25C) 0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1) 12 15 24 48 41.7 33.4 21.0 10.5 9.2 7.4 4.6 2.3 16.7 13.4 8.4 4.2 48max 60max 96max 192max 100max 120max 150max 240max 240max 240max 240max 300max 320max 320max 320max 400max 300max 300max 300max 480max 360max 360max 360max 500max 120max 120max 240max 480max 150max 150max 290max 600max 48max 60max 96max 192max 500typ (ACIN 120V, Io=100%) 16typ (ACIN 120V, Io=100%) 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 43.20 to 52.80 12.00 to 12.48 15.00 to 15.30 24.00 to 24.96 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 55.20 to 67.20 Optional Optional Optional Optional AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -20 to +80C, 20 - 90%RH (Non condensing) -30 to +80C, 20 - 90%RH (Non condensing) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, ANSI/AMII ES60601-1, C-UL, EN60950-1, EN60601-1 Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (class A) *5 76.2X35X127mm [3.0X1.4X5.0 inches] (WXHXD) / 420g max Convection, Forced air (Require external fan), Conduction cooling *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 Please contact us about dynamic load and input response. GHA-4 *5 *6 *7 * * * 6 Please contact us about another class. Specification is changed at option, refer to Instruction Manual. Applicable when AUX and remote control (optional) is added. To meet the specifications. Do not operate over-loaded condition. Sound noise may be generated by power supply in case of pulse load. Parallel operation is not possible. GHA500F Features -Wattage 500W max -High Power density:24.1W/inch3 -High efficiency 92% typ (Input Voltage 230V,Output Voltage 24V) -Conduction cooling - 3"X 5"standard footprint -Fits 1U applications -Industrial and Medical safety approvals -Low leakage current -With Remote On/Off (Optional) -With AUX1 (5V), AUX2 (12V) (Optional) -No minimum load is required Block diagram AC IN 90 - 264V FUSE 250V10A X2 BOOSTER INDUCTER NOISE FILTER CURRENT SENSING INRUSH CURRENT LIMIT RECTIFIER INVERTER FG RECTIFIER AND FILTER CONTROL TRANSFORMER INVERTER CURRENT SENSING INTERNAL RECTIFIER AND FILTER AUX1(12V 1A) RECTIFIER AND FILTER DC OUT CONTROL REGULATOR Photocoupler OVER VOLTAGE PROTECTION Photocoupler PG(POWER GOOD) CONTROL RC(REMOTE ON/OFF) TRANSFORMER RECTIFIER AND FILTER AUX2(5V 1A) External view 4-f3.4(with Mounting Holes M3) Mounting Holes 115.6 ±0.5 5.7 [4.55] [0.22] CN101 TB501 CN101 AC(N) 2 CN501 (Optional) CN101 (Optional) CN501 (Optional) - with Subfeatures(Optional) [4.71] 124.1 Terminal A-41671-A03A197-2 09-50-8031 08-50-0105 08-65-0114 087831-0820 51110-0851 50394-8051 B2P3-VH VHR-3N SVH-21T-P1.1 B8B-PHDSS PHDR-08VS SPHD-002T-P0.5 Voltage adjust [4.89] 127.0 [5.00] Mfr MOLEX J.S.T. FG [0.67] 17.0 119.7 [1.50] 38.0 7 AC(L) FG [0.22] [0.71] 18.0 1 CN501 8 1 Mating connector Terminal Mfr - 170603-2 Tyco Electronics 250 Series <Pin Assignments> <CN101> Pin No. Input 1 AC(L) 2 Name plate 3 AC(N) GHA Tolerance ±1 [±0.04] Weight : 420g max There is a total of four attachment holes. Base Plate : Aluminum Dimensions in mm, [ ]=inches Screw tightening torque : (TB501, 502) : 1.5N-m max Mounting toque : 0.6N-m max Avoid contact between TB501 and 502 wiring with mounting parts. Option : -J1 : (J.S.T) connector type. Refer to Instruction Manual 5. [0.96] 24.5 16.5 ¶ ¶ ¶ ¶ ¶ ¶ ¶ ¶ ¶ [0.65] <CN501(Optional)> [1.38] 35 [3.00] OUTPUT(-) [2.55] 64.8 ±0.5 TB502 3 5.7 76.2 OUTPUT(+) Mating connector I/OConnector Pin No. Function 1 AUX1 : AUX1(12V1A) 2 AUX1G : AUX1(GND) 3 RC1 : REMOTE ON/OFF 4 RCG : REMOTE ON/OFF(GND) 5 PG : Power good 6 PGG : Power good(GND) 7 AUX2 : AUX2(5V1A) 8 AUX2G : AUX2(GND) 2 1 8 7 CN501 GHA-5