Bel ABC450-1T05G Ite safety agency approval Datasheet

The ABC450 Series of open-frame power supplies, with its wide
universal 90-264 VAC input range and high power density, is
available at 450 W of output power and a variety of single and
multiple output voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory
approvals for environmentally-friendly end products.
These medical power supplies are ideal for monitoring, home health
equipment as well as surgical devices.
•
4 x 6.5 x 1.61 inches
•
Universal AC Input
•
450 W (with airflow), 300 W (without airflow)
•
Current Sharing Option
•
Cover and Fan Options
•
Peak Power Capability
•
Low Standby Power
•
Side Fan or Top Fan Mounting Option Product
•
(–S or –T to be added to model number)
•
Current Sharing Option Product (–I to be added to model number)
•
ITE Safety Agency Approvals
•
RoHS Compliant
•
CE marked
•
Instrumentation
•
Robotics
•
Lighting
•
Renewable Energy
•
Industrial Applications
•
Data Communication
•
Test and Measurement
•
Applied Computing
ABC450 Series
2
5 VDC
MAX LOAD
(CONVECTION) 1,2,3
31.0 A
MAX LOAD
(420 LFM) 1,2,3
55.0 A
ABC450-1T12G
12 VDC
20.83 A
ABC450-1T15G
15 VDC
16.66 A
MODEL
OUTPUT VOLTAGE
ABC450-1T05G
0.0 A
RIPPLE &
NOISE4
2%
37.5 A
0.0 A
2%
30.0 A
0.0 A
2%
2%
MINIMUM LOAD
ABC450-1T24G
24 VDC
12.30 A
18.75 A
0.0 A
ABC450-1T30G
30 VDC
10.0 A
15.0 A
0.0 A
2%
9.37 A
0.0 A
2%
ABC450-1T48G
48 VDC
6.25 A
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATIONS
Input Voltage
Universal
90-264 VAC / 120-390 VDC
Input Frequency
Input Current
No Load Power
Inrush Current
Leakage Current
Input Protection
Power Factor
Switching Frequency
47 to 63 Hz
120 VAC:
230 VAC:
120 VAC:
230 VAC:
120 VAC:
230 VAC:
Earth Leakage Current
Touch Leakage Current
4.5 A max.
2.3 A max.
0.4 W
0.8 W
40 A max.
75 A max.
270 µA
45 µA @120 VAC / 63 Hz
Dual fusing, in AC Line and AC Neutral
T8A / 250 V
120 VAC
230 VAC
PFC converter: Variable
Resonant converter: Variable
0.98
0.95
45-160 kHz typical
35-250 kHz, 90 kHz typical
1
Combined output power of main output, fan supply and standby supply shall not exceed max. power rating
Standby output voltage 5 V/ 1.5 A (convection) / 2 A (420LFM) with tolerance including set point accuracy, line and load regulation is
+/-10%. Ripple and noise is less than 5%.
3
Fan supply output voltage 12 V / 500 mA with tolerance including set point accuracy, line and load regulation is +/-30% and needs min.
1% load on main output to be within regulation band. Ripple and noise is less than 10%.
4
Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage
and load ranges. Please contact factory/ sales representative for minimum load required for ripple to be within specification.
2
[email protected]
ABC450 Series
3
PARAMETER
DESCRIPTION / CONDITION
Output Power5
475 W for 24 V, 30 V & 500 W for 48 V model
only for 5 seconds max.
24 V, 48 V, 30 V
120 VAC
12 V, 15 V
5V
Efficiency (Full Load)
230 VAC
Hold Up Time
SPECIFICATIONS
24 V, 48 V, 30 V
120 / 230 VAC
88%
86%
83% typical
90%
10 ms
Line Regulation
+/-0.5%
Load Regulation
Transient Response
155 to 450 W
+/-3%
<10%, 50% to 100% load change, 50 Hz, 50% duty
cycle, 0.1 A/µs
Rise Time
Recovery time < 5 ms
< 100 ms
Set Point Tolerance
+/-1%
Voltage Adjustment
V1
±3%
Over Voltage Protection
Latch Type
>114%
Over Current Protection
Hic-Up type
120 to 150%
Short Circuit Protection
Short term, auto recovery
Over Temperature Protection
Automatic recovery
Current Share
Up to 2 supplies connected in parallel (optional)
130°C primary heat sink
PARAMETER
DESCRIPTION / CONDITION
Power Good Signal
TTL signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s
Remote Sense
Compensates for 200 mV drop
Remote on/off
To turn on PSU short remote pin to ground
Conducted Emissions
EN55032-B, CISPR22-B, FCC PART15-B
Pass
Radiated Emissions
EN 55032 A;
with external core (King core K5B RC 25x12x15-M in input cable)
Pass
Level B
Input Current Harmonics
EN 61000-3-2
Class D
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
5
Derate output power linearly to 80% from 90 VAC to 80 VAC input.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00326_AG
Asia-Pacific
+86 755 298 85888
ABC450 Series
4
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATIONS
Operating Temperature
Refer to derating curve (Figure 1)
0 to +70°C
Storage Temperature
-40 to 85° C
Humidity
Non Condensing
95% HR
Altitude
Operating:
Non-Operating:
10,000 ft.
40,000 ft.
Convection: 155 W
420 LFM: 275 W
Convection: 250 W
420 LFM: 450 W
Convection: 300 W
420 LFM: 450 W
5 V model
Cooling
12 V & 15 V models
24 V, 30 V & 48 V models
Reliability
MTBF according to Telcordia -SR332-Issue 3
PARAMETER
1.28 million hours
DESCRIPTION / CONDITION
SPECIFICATION
4242 VDC
2121 VDC
Agency Approvals
Input to Output
Input to Earth
Approved to the latest edition of the following standards:
CSA/UL60950-1, EN60950-1 and IEC60950-1; Class1 SELV
Nemko, Nemko-CCL
CE mark
Complies with LVD Directive
Isolation Voltage
Safety Standards
CONNECTOR
PIN
DESCRIPTION / CONDITION
AC Input Connector
J1
Pin 1
Pin 3
Pin 5
DC Output Connector
J2
Lug 1
Lug 2
+V1
RTN
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 1
Pin 2
NC
Power Fail
Power Good
DC Return
+5Vstby
+VE Remote Sense
-VE Remote Sense
CS
DC Return
Remote On/Off
+VE
-VE
Signals6
J3
Fan
J4
Earth7
J5
MANUFACTURER / PN
AC line
AC neutral
Earth
Tyco: 1-1123724-3
Mating: 1-1123722-5
6-32 inches Screw Pan HD
Mating: 16 AWG wire crimped to Ring Tongue Terminal AMP: 831886-1
Molex: 22-23-2081
Mating: 22-01-2087; Pins: 08-50-0113
Mating Connector: Molex 22-01-2025
Pins = 08-50-0113
Molex: 19705-4301
Mating: 190030001
6
PSU is supplied with J3, pin-9 and pin-10 shorted to enable main output without remote on/off feature
The J5 (Earth) spade connector can be used for U-Channel option products only. When fan options are required the earth connection
provided in the input AC connector should be used (Pin 5 – J1)
7
[email protected]
ABC450 Series
5
Convection load: 155 W up to 40 °C
De-rate above 40 °C @ 1.67% per °C
Forced air cooled load: 275 W up to 40°C
De-rate above 40 °C @ 1.67% per °C
Convection load: 250 W up to 40 °C
De-rate above 40 °C @ 1.67% per °C
Forced air cooled load: 450 W up to 40°C
De-rate above 40 °C @ 1.67% per °C
Convection load: 300 W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
Forced air cooled load: 450 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Figure 1. Derating Curves
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00326_AG
Asia-Pacific
+86 755 298 85888
ABC450 Series
6
PARAMETER
DESCRIPTION / CONDITION
Weight
900 g (1.98 lbs)
Dimensions
101.6 x 165.0 x 41.0 mm (4.0 x 6.5 x 1.6 inch)
Figure 2. Mechanical Drawing (Without Fan Mounting)
[email protected]
ABC450 Series
7
Figure 3 - Mechanical Drawing (With Top Fan Mounting)
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00326_AG
Asia-Pacific
+86 755 298 85888
ABC450 Series
8
Figure 4 - Mechanical Drawing (With Side Fan Mounting)
[email protected]
ABC450 Series
9
During the installation and setup of parallel supplies in a system it is important that a single remote sense point be used for all
the supplies.
The remote sense voltage between the supplies must be adjusted to within 2% to ensure the supplies are inside the 3% capture
window.
If the supplies are not initially adjusted inside the capture window the supplies will not current share.
NOTE:
“CURRENT SHARING “ facility is inclusive with the unit only with ordering of the “ CURRENT SHARING “ option unit i.e.
ABC450-1XXX-I or ABC450-1XXX-I.
SET-UP PROCEDURE:
1
2
3
4
5
6
Connect load cables to the outputs of each supply.
Connect the remote sense lines to the load in twisted style. (A common remote sense point must be used for all the
supplies in parallel).
Connect all the “current share” pins on the J3 connector between the supplies.
Adjust remote sense voltage of each supply to within 1% of rated output voltage or readjust to required set point.
(Adjustment to be done with all other parallel supplies off).
Current sharing between the supplies can be verified by monitoring the output current of each supply with a hall effect DC
current probe. The supplies should share to within 10% of the total load current.
The current share circuit has a capture window voltage of +/- 3% of the rated output voltage. If the output remote sense
voltage of one of the supplies is adjusted outside the 3% window the supplies will not current share.
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00326_AG
Asia-Pacific
+86 755 298 85888
Similar pages