MORNSUN LH25-20B12MU Universal input Datasheet

AC/DC Converter
LH25-20BxxMU Series
25W, AC-DC converter
FEATURES
Universal Input : 85 - 264VAC, 100 - 370VDC, 50/60Hz
Regulated output , Low ripple & noise
Low no-load power consumption < 0.1W
High efficiency up to 89%
Output short circuit, over-current, over-voltage
protection
 Meets EN60601-1, ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1 standards
(2xMOPP)(Pending)
 Mounting: PCB mounting, Chassis mounting,
DIN-Rail mounting available
 Meets 5000m altitude requirements





RoHS
LH25-20BxxMU series ----- is a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC
Input voltage, low power consumption, high efficiency, high reliability, safer isolation. Meets EN60601-1, ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1 standards (2xMOPP), and widely used in medical, industrial, instruments, telecommunication and civil
applications. For harsh EMC environment, the application circuit in the datasheet is strongly recommended.
Selection Guide
Certification
CSA/CE
(Pending)
Part No.
Output Power
LH25-20B05MU
20.5W
Nominal Output Voltage and
Current(Vo/Io)
Efficiency
(230VAC, %/Typ.)
Max. Capacitive
Load(µF)
LH25-20B12MU
LH25-20B15MU
25 W
LH25-20B18MU
LH25-20B24MU
5V/4100mA
82
10000
12V/2100mA
88
5000
15V/1600mA
88
4000
18V/1400mA
88
3000
24V/1100mA
89
1000
Input Specifications
Item
Operating Conditions
Input Voltage Range
Min.
Typ.
Max.
Unit
AC input
85
--
264
VAC
DC input
100
--
370
VDC
47
--
440
Hz
115VAC
--
--
0.6
230VAC
--
--
0.34
115VAC
--
10
--
--
25
--
Input frequency*
Input current
Inrush current
230VAC
A
Leakage current
0.1mA RMS typ./264VAC/60Hz
Recommended External Input
Fuse(Special package series include fuse)
3.15A/250V, slow fusing
Hot Plug
Unavailable
*Medical Certification Input frequency range:47-63 Hz
Output Specifications
Item
Operating Conditions
Output Voltage Accuracy
Main circuit
Full load
Line Regulation
Load Regulation
Ripple & Noise*
Temperature Coefficient
20MHz bandwidth (peak-peak value)
Min.
Typ.
Max.
--
±2
--
--
±0.5
--
--
±1
--
--
50
150
mV
--
±0.02
--
%/°C
%
Short Circuit Protection
Continuous, self-recovery
Over-current Protection
≥110%Io self-recovery
2016.09.13-A/0
Unit
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH25-20BxxMU Series
Over-voltage Protection
5VDC Output
≤7.5VDC
12 /15VDC Output
≤20VDC
18VDC Output
≤25VDC
24VDC Output
≤30VDC
0
--
--
115VAC input
--
15
--
230VAC input
--
80
--
Min. Load
Hold-up Time
%
ms
Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation.
General Specifications
Item
Operating Conditions
Min.
Test time: 1min Leakage current≦5mA
4000
--
--
Operating Temperature
-40
--
+70
Storage Temperature
Storage Humidity
-40
--
+85
--
95
Isolation Voltage
Input-output
Typ.
--
Welding Temperature
Unit
VAC
°C
%RH
Wave-soldering
260 ± 5℃; time:5 - 10s
Manual-welding
360 ± 10℃; time:3 - 5s
Switching Frequency
Power Derating
Max.
-40℃ to -25℃
+50℃ to +70℃
5V Output
+55℃ to +70℃
Others
Safety Standard
Safety Certification
--
65
--
3.3
--
--
kHz
2.5
--%/°C
3.3
--EN60601-1,ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1
EN60601-1,ANSI/AAMI ES60601-1,
CAN/CSA-C22.2 No. 60601-1(Pending)
CLASSⅡ
Safety Class
First side-Second side
Insulation Level
2xMOPP
MIL-HDBK-217F@25°C≥ 300,000 h
MTBF
Physical Specifications
Casing Material
Dimension
Weight
Black flame-retardant and heat-resistant plastic (UL94V-0)
Horizontal package
70.00*48.00*23.50mm
A2 chassis mounting
96.10*54.00*32.00mm
A4 Din-Rail mounting
96.10*54.00*36.60mm
Horizontal package
120g (Typ.)
A2 chassis mounting
170g (Typ.)
A4 Din-Rail mounting
210g (Typ.)
Cooling method
Free air convection
EMC Specifications
EMI
CE
EN55011(CISPR11) / EN55022(CISPR22) CLASS B
RE
EN55011(CISPR11) / EN55022(CISPR22) CLASS B
ESD
IEC/EN61000-4-2
Contact ±6KV/Air ±8KV
Perf. Criteria B
RS
IEC/EN61000-4-3
10V/m
perf. Criteria A
IEC/EN61000-4-4
±2KV
perf. Criteria B
IEC/EN61000-4-4
±4KV (See Fig. 2 for recommended circuit)
perf. Criteria B
IEC/EN61000-4-5
line to line ±1KV
perf. Criteria B
IEC/EN61000-4-5
line to line ±2KV (See Fig. 2 for recommended circuit)
perf. Criteria B
CS
IEC/EN61000-4-6
10 Vr.m.s
perf. Criteria A
Voltage dips, short
interruptions and voltage
variations immunity
IEC/EN61000-4-11
0%,70%
perf. Criteria B
EFT
EMS
Surge
2016.09.13-A/0
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH25-20BxxMU Series
O u tp u t P o w e r P e rc e n ta g e ( % )
Te m p e r a t u r e D e r a t in g C u r v e
100
5 V O u tp u t
O th e r s
80
60
50
40
In p u t v o l ta g e : 8 5 - 2 6 4 VA C
100-370VD C
20
-4 0
-25
50 55 70
A m b ie n t te m p e r a t u r e ( ℃ )
O u tp u t P o w e r P e rc e n ta g e( % )
O u t p u t P o w e r P e r c e n t( % )
Product Characteristic Curve
In p u t V o lt a g e D e ra tin g C u r v e
100
80
75
60
A m b ie n t t e m p e r a t u r e : 2 5 ℃
40
20
85
100
100
120
A ltitu d e D e r a tin g C u r v e
240
340
I n p u t V o lt a g e
264
370
VA C
VDC
10 0
80
60
40
20
0
50 00
30 00
A ltitu d e (m )
Note: ①When input 85-100VAC/100-120VDC, it need to be voltage derated on basis of temperature derating;
②Altitude should be derated based on temperature derating when it is 3000 - 5000m;
③This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
Design Reference
1. Typical application circuit
A C (L)
A C (L )
+ Vo
C1
C2
TVS
RL
AC -DC
A C (N )
- Vo
A C (N )
C2(µF)
330
330
330
120
68
型号
LH25-10B05MU
LH25-10B12MU
LH25-10B15MU
LH25-10B18MU
LH25-10B24MU
FU S E
TVS1
SMBJ7.0A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ30A
Fig. 1: Typical application circuit
Note: Output filtering capacitors C2 is electrolytic capacitor, it is recommended to use high frequency and low impedance electrolytic capacitor. For
capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitor withstand voltage derating should be 80% or above. C1 is ceramic
capacitor, which is used to filter high-frequency noise, advice use 1μF. TVS is a recommended component to protect post-circuits if converter fails. External input
FUSE model is recommended to use 3.15A/250V slow fusing
2. EMC solution-recommended circuit
C a n u se M O R N SU N ' s F C -L X 1 D
LD M
F US E
LC M
A C( L)
A C( L)
C Y1
MOV 1
CX
+V o
C1
C2
TV S
RL
+
A C -D C
C Y2
-V o
A C( N )
A C( N )
Fig 2: EMC Recommended circuit with higher requirements
2016.09.13-A/0
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH25-20BxxMU Series
Element model
MOV1
Recommended value
S14K300
CY1 , CY2
1nF/400VAC
CX
0.1μF/275VAC
LCM
10mH, recommended to use MORNSUN’s FL2D-Z5-103
LDM
4.7μH/2A
FC-LX1D
2KV/4KV EMC filter
FUSE
3.15A/250V slow fusing, necessary
3. For more information Please find the application note on www.mornsun-power.com
Dimensions and Recommended Layout
A2 Dimensions
2016.09.13-A/0
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH25-20BxxMU Series
A4 Dimensions
Note:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing
bag number of Horizontal package : 58220006, the Packing bag number of A2 /A4 package:58220010;
2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all
parameters in the datasheet;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25 ℃, humidity<75% with nominal
4.
5.
6.
7.
input voltage and rated output load;
All index testing methods in this datasheet are based on our Company’s corporate standards;
The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model
products may exceed the requirements mentioned above. Please contact our technicians directly for specific information;
We can provide product customization service;
Specifications are subject to change without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2016.09.13-A/0
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages