NTCAFLEX05 Series www.vishay.com Vishay BCcomponents NTC Thermistors, Flex Foil Sensors FEATURES • • • • • DESIGN SUPPORT TOOLS click logo to get started Rapid response time on surface down to 2 s Suitable for narrow space applications High flexibility of the foil Insulated and humidity resistant A strain relief hole is included in the flex design to avoid traction to the sensor head • Gold plated terminations • AEC-Q200 qualified • Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 APPLICATIONS Models Available • • • • • • Design Tools Available • NTC curve computation: www.vishay.com/thermistors/ntc-curve-list/ QUICK REFERENCE DATA PARAMETER Resistance value at 25 °C VALUE UNIT 10K to 122K ± 1; ± 3 % Tolerance on R25-value B25/85-value 3435 to 3960 K ±1 % -40 to +125 °C 2 s < 0.02 K/K 500 VAC Tolerance on B25/85-value Operating temperature range at zero power Thermal time constant by heating (1) (3) Thermal gradient (3) Minimum dielectric withstanding voltage (2) Minimum insulation resistance 10 M Maximum dissipation at 25 °C 60 mW 0.06 g Weight (without connector) Notes (1) Measured from 25 °C air to 125 °C heated plate, pressed on the surface (2) Withstanding voltage up to 4 kV AC between the NTC and the bottom stiffener (3) Thermal time constant and thermal gradient are dependent on the way of mounting Consumer appliances and white goods Power supply (heat-sinks) Battery, displays, LED Industrial applications, robotics Boilers EV and HV batteries DESCRIPTION • Miniature NTC thermistor body mounted on an insulated flex foil and topped with an insulating epoxy glob top • For flat surface temperature sensing with low thermal mass and rapid response time MOUNTING • The stiff flat sensing area can be pressed against a flat surface by means of insulating material (silicone foam), by spring force or by taping it with a double sided temperature resistant adhesive • The sensor contacts can be connected to a PCB counter-connector or wire-to-wire connector or soldered to conductors, or crimped with FFC connectors and ZiF connectors • A mating connector can be for example a 0.5 mm pitch 7 poles connector for FPC, with top contacts, accepting 4 mm FPC width, ZIF or non-ZIF versions. The poles (1 + 2) and (6 + 7) can be used for the electrical connection. For example in SMT versions : TE 1734839-7, Hirose FH34S-7S-0,5SH(50), Molex 054550-0771, Molex 052745-0797 • Consult Vishay for other screw sizes, lead length, insulation, connector crimping or other features Note • FFC/FPC = Flexible Film Circuit/Flexible Printed Circuit ELECTRICAL DATA AND ORDERING INFORMATION R25 () R25-TOL. (± %) B25/85 (K) B25/85 -TOL (± %) DESCRIPTION SAP MATERIAL AND ORDERING NUMBER 10 000 1 3435 1 NTC Flex05 10K 1 % 3435K 25 mm NTCAFLEX05103FL 10 000 3 3960 1 NTC Flex05 10K 3 % 3960K 25 mm NTCAFLEX05103HH 47 000 3 3960 1 NTC Flex05 47K 3 % 3960K 25 mm NTCAFLEX05473HH 122 000 1 3590 1 NTC Flex05 122K 1 % 3590 K 25 mm NTCAFLEX05124FM Revision: 21-Sep-17 Document Number: 29132 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 NTCAFLEX05 Series www.vishay.com Vishay BCcomponents SAP CODIFICATION Part Number: NTCAFLEX01473HH N T C A F L E X 0 5 4 7 3 H H MODEL ASSEMBLY FLEX SENSOR MECHANICAL EXECUTION RESISTANCE VALUE TOLERANCE ON R25 B-VALUE RANGE NTC A FLEX 05 103 = 10 x 103 473 = 47 x 103 124 = 12.2 x 104 H=±3% F=±1% L (low) = 3000 B25/85 < 3500 M (medium) = 3500 B25/85 < 3750 H (high) = 3750 B25/85 < 4000 X (very high) = 4000 B25/85 < 4250 OPTION Blank MECHANICAL DATA DIMENSIONS in millimeters L1 L15 L2 Ø D1 L4 L5 H1 P P2 20 ± 1 25 ± 1 3 ± 0.5 6 ± 0.5 4±1 3±1 1.40 ± 0.2 2.50 1 1. NTC on flex foil circuit, sensing area on the flat bottom side 2. Flex foil circuit 3. High quality modified epoxy glob top 4. Conductive tracks, gold plated RELIABILITY TEST (following IEC 60068 test methods) TEST PROCEDURE REQUIREMENT Dry heat, steady state 125 °C; 1000 h R/R 3 % 56 days at 40 °C 90 % to 95 % RH R/R 3 % -40 °C to +125 °C; 100 cycles R/R 3 % Damp heat, steady state Rapid change of temperature Revision: 21-Sep-17 Document Number: 29132 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. © 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 08-Feb-17 1 Document Number: 91000