CUT75 Series Dual or Triple Output 75W Low Profile Power Supplies Features 3 x 5 x 1.06” footprint Output 1 isolated from outputs 2 & 3 No minimum loading Convection Cooled Three year warranty Key Market Segments & Applications Specifications Model AC Input Voltage (1) Input Frequency DC Input Voltage Inrush Current (cold start) Power Factor Input Current (100 / 200VAC) Temp. Coefficient (-20 to +70°C) Overcurrent Protection Overvoltage Protection (2) Hold Up Time (115 / 230V input) Leakage Current (265VAC 50Hz) Operating Temperature (3) Storage Temperature Op. Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock Immunity Safety Agency Certifications Conducted & Radiated EMI Weight (Typ) Size (WxLxH) Warranty CUT75-522 VAC Hz VDC A A V ms mA g in (mm) - CUT75-5FF 85 - 265VAC 47 - 63Hz 120 - 370VDC (No safety certification) 18A at 100VAC, 36A at 200VAC Meets EN61000-3-2 2/1 V1: <0.02%/°C, V2 & 3 <0.03%/°C > 105% V1: 5.7-7.0, V2: 13.8 - 18.8V V1: 5.7-7.0, V2: 17.2 - 21.0V 20ms <0.3mA -20 to +70°C. Derate linearly to 60% load from +50 to +70°C -30 to +85°C 5 - 95% RH Convection Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC, V1 to V2 / V3 500VAC for 1 min. >100M at 25°C & 70%RH, Output to Ground 500VDC 10 - 55Hz: 19.6m/s2 constant sweep 1 min X, Y, Z for 1 hour < 196.1 m/s2 (20G) IEC61000-4-2 (lv 3, 4), -3 (lv3), -4 (lv 4), -5 (lv3, 4), -6 (lv 3), -8 (lv 4), -11 UL60950-1, CSA60950-1-07 (cTUVus), EN60950-1, CE Mark EN55011/EN55022-B, FCC--B 210 (open frame version) 3 x 5 x 1.06” (76 x 127 x 27) Three Years (1) Derate linearly to 60% load from 100VAC to 85VAC input (2) Cycle AC to reset (3) See derating curves in installation manual for all mounting orientatons 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 129 Disclaimer: us.tdk-lambda.com/lp/legal.htm CUT75 Series Model Selector Voltage (V) Adjust Range (V) Max Current (A) Max Power (W) V1 5V 5.0 - 5.25 8 40 100 50 120 V2 +12V Fixed 3 36 600 240 150 V3 -12V Fixed 1 600 240 150 V1 5V 5.0 - 5.25 8 40 100 50 120 V2 24V Fixed 1 24 750 300 150 5.0 - 5.25 8 40 100 50 120 37.5 750 300 150 750 300 150 Model CUT75-522 CUT75-522 Load Reg Line Reg (mV) (mV) Ripple Noise (mV) (Leave common terminal unconnected) CUT75-5FF CUT75-5FF V1 5V V2 +15V Fixed 2.5 V3 -15V Fixed 1 V1 5V 5.0 - 5.25 8 40 100 50 120 V2 30V Fixed 1 30 750 300 150 (Leave common terminal unconnected) Note: CUT75 can be configured as a dual or triple output. Outline Drawing Options Suffix Blank /A /B /T /TA /TB Description Open frame with JST connectors Cover with JST connectors Baseplate with JST connectors Open frame with screw connections Cover with screw connections Baseplate with screw connections Preferred Model Similar Models SC40-60 3x5” 40W to 60W 1 to 3 outputs ZPT 2x4” 40W 1 to 3 outputs NV175 3x5” 175W, 1 to 4 outputs ZMS100 2x4” 100W single output For Additional Information, please visit us.tdk-lambda.com/lp/products/cut75-series.htm 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 130 Revision P1.4: Feb 2015