SICK C4C-EA13510A10000 Safety light curtain Datasheet

Online data sheet
C4C-SA13510A10000, C4C-EA13510A10000
deTec4 Core
SAFETY LIGHT CURTAINS
C4C-SA13510A10000, C4C-EA13510A10000 | deTec4 Core
SAFETY LIGHT CURTAINS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
System part
Type
Part no.
Sender
C4C-SA13510A10000
1211480
C4C-EA13510A10000
1211481
Receiver
Other models and accessories
www.sick.com/deTec4_Core
Detailed technical data
Features
System part
Sender/receiver pair with QuickFix bracket
Resolution
14 mm
Protective field height
1,350 mm
Scanning range
Minimum 0 m ... 7 m
Typical 0 m ... 8 m
Response time
17 ms
Synchronization
Optical synchronisation
Safety-related parameters
Type
Type 4 (IEC 61496)
Safety integrity level
SIL3 (IEC 61508)
SILCL3 (EN 62061)
Category
Category 4 (EN ISO 13849)
Performance level
PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour)
3,7 x 10-9 (EN ISO 13849)
TM (mission time)
20 years (EN ISO 13849)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
Interfaces
System connection
Connection type Male connector M12, 5-pin
Permitted cable length ≤ 50 m
Fieldbus, industrial network
1)
2
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-21 16:38:06
Subject to change without notice
C4C-SA13510A10000, C4C-EA13510A10000 | deTec4 Core
SAFETY LIGHT CURTAINS
Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 1)
1)
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class
III (EN 50178)
Supply voltage VS
24 V DC (19.2 V DC ... 28.8 V DC)
Ripple
≤ 2.4 Vpp 1)
Power consumption typical
3.6 W / 1.8 W (depending on type)
Safety outputs (OSSD)
Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 2)
Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS)
Switching voltage LOW ≤ 2 V DC
Switching current ≤ 300 mA
1)
2)
Within the limits of VS.
Applies to the voltage range between –30 V and +30 V.
Mechanical data
Housing cross-section (incl. system connection)
34 mm x 30.7 mm
Housing material
Aluminum extruded profile
Weight
1,250 g / 1,240 g (depending on type)
Ambient data
Enclosure rating
IP65 (EN 60529)
IP67 (EN 60529)
Ambient operating temperature
–30 °C ... +55 °C
Storage temperature
–30 °C ... +70 °C
Air humidity
15 % ... 95 %, Non-condensing
Vibration resistance
5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Shock resistance
10 g, 16 ms (EN 60068-2-29)
Other information
Wave length
850 nm
Classifications
ECl@ss 5.0
27272704
ECl@ss 5.1.4
27272704
ECl@ss 6.0
27272704
ECl@ss 6.2
27272704
ECl@ss 7.0
27272704
ECl@ss 8.0
27272704
ECl@ss 8.1
27272704
ECl@ss 9.0
27272704
ETIM 5.0
EC002549
ETIM 6.0
EC002549
2017-08-21 16:38:06 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
3
C4C-SA13510A10000, C4C-EA13510A10000 | deTec4 Core
SAFETY LIGHT CURTAINS
UNSPSC 16.0901
46171620
Dimensional drawing (Dimensions in mm (inch))
21.1
(0.83)
13
56.8
(0.51)
(2.24)
30.7
(1.21)
29.5
L
(1.16)
L
34
6.3
(0.25)
(4.2)
106.8
21.8
(0.86)
5
56.8
(2.24)
13.8
L=150 (5.91)
1
4
4
(0.16)
56.8
(0.54)
14
(0.55)
30
30.7
(1.21)
(1.18)
(1.34)
(2.24)
H
I
J
K
L
M
N
O
P
Q
R
S
T
(0.2)
A
B
C
D
E
F
7
(0.28)
12
(0.47)
2
5
3
L
4
300
313
450
463
600
613
750
763
900
913
1,050
1,063
1,200
1,213
1,350
1,362
1,500
1,512
1,650
1,662
1,800
1,812
1,950
1,962
2,100
2112
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-21 16:38:06
Subject to change without notice
C4C-SA13510A10000, C4C-EA13510A10000 | deTec4 Core
SAFETY LIGHT CURTAINS
Connection diagram
deTec4 Core safety light curtain connected to UE48-2OS safety relay
24 V DC
1 +24V
2 n.c.
3
OSSD1
2
GND 3
GND
4 n.c.
5
+24V 1
OSSD2 4
n.c.
n.c.
5
S1
S33 S11 S12 S31 A1
k1
k2
13 23
31
14 24
32
UE48-2OS2D2
S34 S35 S21 S22 A2
K1
K2
0 V DC
E114585/01/2014-05-08
Task
Connection of a deTec4 Core safety light curtain to UE48-2OS.
Operating mode: with restart interlock and external device monitoring.
Function
When the light path is clear, the OSSD1 and OSSD2 outputs are live. The system is ready to switch on if K1 and K2 are de-energized. By pressing S1 (button is pressed and released), the UE48-2OS is energized and its 13 - 14 and 23 - 24 contacts activate K1
and K2. On interruption of one of the light beams, the UE48-2OS is de-energized by the OSSD1 and OSSD2 outputs and K1 and K2
are deactivated.
Fault analysis
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The incorrect functioning of one of the
K1 or K2 contactors will be detected and does not result in the loss of the shutdown function. Jamming of the S1 button will prevent the UE48-2OS from enabling.
Comments
1)
Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, the integration must be dual-channel (x/y paths). Single-channel integration in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
2017-08-21 16:38:06 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
5
C4C-SA13510A10000, C4C-EA13510A10000 | deTec4 Core
SAFETY LIGHT CURTAINS
A
B
C
D
E
F
Recommended accessories
Other models and accessories
www.sick.com/deTec4_Core
Brief description
Type
Part no.
Self-adhesive
protective film
2069268
4 pieces, FlexFix bracket, plastic, can be aligned ± 15°, including screw M5, Plastic
BEF-1SHABPKU4
2066614
2 pieces, QuickFix bracket, Plastic
BEF-3SHABPKU2
2066048
DSC-1205T000025KM0
6030664
Head A: female connector, M12, 5-pin, straight
Head B: cable
Cable: Power, I/O, drag chain use, PUR, halogen-free, unshielded, 2 m
DOL-1205-G02MC
6025906
Head A: female connector, M12, 5-pin, straight
Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 5 m
DOL-1205-G05MC
6025907
Head A: female connector, M12, 5-pin, straight
Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 10 m
DOL-1205-G10MC
6025908
Head A: female connector, M12, 5-pin, straight
Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 20 m
DOL-1205-G20MC
6050247
Head A: female connector, M12, 5-pin, straight
Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 30 m
DOL-1205-G30MC
6050248
Head A: female connector, M12, 5-pin, angled
Head B: cable
Cable: Power, I/O, drag chain use, PUR, halogen-free, unshielded, 2 m
DOL-1205-W02MC
6025909
Head A: female connector, M12, 5-pin, angled
Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 5 m
DOL-1205-W05MC
6025910
Head A: female connector, M12, 5-pin, angled
Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 10 m
DOL-1205-W10MC
6025911
Head A: female connector, M12, 5-pin, straight, A-coding
Head B: male connector, M12, 5-pin, straight, A-coding
Cable: digital I/Os, drag chain use, PUR, halogen-free, unshielded, 5 m
DSL-1205-G05MC
6029282
Head A: female connector, M12, 5-pin, straight, A-coding
Head B: male connector, M12, 5-pin, straight, A-coding
Cable: digital I/Os, drag chain use, PUR, halogen-free, unshielded, 10 m
DSL-1205-G10MC
6038954
Head A: female connector, M12, 5-pin, straight, A-coding
Head B: male connector, M12, 5-pin, straight, A-coding
Cable: digital I/Os, drag chain use, PUR, halogen-free, unshielded, 15 m
DSL-1205-G15MC
6038956
Device protection (mechanical)
1 piece, self-adhesive protective film for the front screen (protects sensors from damage by flying sparks and welding beads)
Terminal and alignment brackets
Adapters and distributors
CANopen, T-piece
H
I
J
K
L
M
N
O
P
Q
R
S
T
Plug connectors and cables
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-21 16:38:06
Subject to change without notice
C4C-SA13510A10000, C4C-EA13510A10000 | deTec4 Core
SAFETY LIGHT CURTAINS
Brief description
Type
Part no.
Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into
the beam!
AR60
1015741
AR60 adapter,
deTec, MLG-2
4070854
Test rod 14 mm
2022599
Alignment aids
Adapter AR60 for deTec4, deTec2 and MLG-2
Test and monitoring tools
14 mm diameter
2017-08-21 16:38:06 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
7
Online data sheet
SICK at a glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”
Worldwide presence:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com
Similar pages