ASL40 4 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies series Up to 40W Output Power Universal 90-264VAC Input Single and Dual Outputs from 5VDC to 48VDC High Efficiency up to 86% 3000V Isolation 1U Compatible Height 2”W x 4”L x 1.2”H Model Number Output Voltage Max. O/P Amps Min. O/P Amps Efficiency @ 230VAC R&N P-P Current Limit SINGLE OUTPUT ASL40-5(A)* ASL40-9(A)* ASL40-12(A)* ASL40-15(A)* ASL40-24(A)* ASL40-36(A)* ASL40-48(A)* 5VDC 9VDC 12VDC 15VDC 24VDC 36VDC 48VDC 8 4.44 3.33 2.66 1.66 1.11 0.83 0 0 0 0 0 0 0 73% 82% 84% 84% 86% 85% 86% 100mV 100mV 150mV 150mV 150mV 100mV 400mV 170% 200% 240% 240% 240% 187% 240% DUAL OUTPUT ASL40D-1 ASL40D-2 ASL40D-3 ASL40D-5 (V1/V2) 5/12VDC 5/15VDC 5/24VDC 5/48VDC (I1/I2) 3.3/2 3.3/1.6 3.3/1 3.3/0.50 0.66/0.40 0.66/0.32 0.66/0.20 0.66/0.10 81% 82% 82% 82% 100/120mV 100/150mV 100/240mV 100/400mV 225% 225% 225% 225% *Note: The Single Outputs can be ordered with Molex 09-50-30x1 I/O connectors.. Simply add the suffix “A” to the end of the Model Number. For example, ASL40-5A WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASL40 4 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: Leakage Current series GENERAL SPECIFICATIONS 90-264 VAC 47-63 Hz 30A @ 100VAC Input * 60A @ 200VAC Input * <0.1mA Input-Out Isolation Efficiency Switching Frequency Safety 3000VAC See Selection Chart 65Khz, (fixed, typical) UL, TUV, CB PHYSICAL SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage and Current See Selection Chart Load Regulation (0%-FL) Single O/P: ± 1% Dual O/P (V1/V2): ± 3/5% max Line Regulation (LL-HL) Single O/P: ± 1% max Dual O/P (V1/V2): ± 1/2% max Cross Regulation (Dual Outputs) (100-20% L w. other O/P at 60%) ± 3/5% max Preset Accuracy 1% DC Voltage Adjust (typ) ± 6% of FS (Primary) Temperature Coefficient ± 0.05%/°C Ripple/Noise, 20Mhz BW See Selection Chart Over Voltage Protection Clamp, 118-130% Current Limit, Self Recovering See Selection Chart * Short Circuit Protection Continuous, self-recovering * Hold Up Time (115V / 60Hz) 10 mS, min. Size Construction Weight 2” x 4” x 1.2” 50.8 x 101.6 x 30.48mm Open Frame 7oz (198g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity EMC MTBF -20 to +50°C(FL) , See Derate -40 to +85°C * 0 to + 95%, non-cond * EN 60601-1-2:2001 185,000 Hrs Mil Std 217, 25°C OUTPUT DERATING CURVE 100 90 80 Load (%) 70 60 50 40 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted 30 * These are stress ratings. Exposure of the devices to any of these conditions 10 may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. WWW.ASTRODYNE.COM 20 0 -20 10 20 30 40 50 60 70 Ambient Temperature DegC ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASL40 4 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies series MECHANICAL DIMENSIONS with JST Connectors - standard 1.165 29.60 Input Connector: JST B3P-VH Input Mating Connector: JST VHR-3N or Molex 51144 Series Output Connector: JST B4P-VH Output Mating Connector: JST VHR-4N or Molex 53520 & 53521 Series Use with JST # SVH-21T-P1.1 or Molex # 50539-8100 Crimp Terminals 4 .0 0 0 1 0 1 .6 0 0.150 3.80 1.701 43.20 2.000 50.80 4 X O 3 .1 7 ( O 0 .1 2 5 ) 3 4 5 6 L 1 N 2 WWW.ASTRODYNE.COM All 4 corner holes need to be bonded accordingly to the end product PE (Protective Earth) path. 3 .7 0 1 94 0 .1 5 0 3 .8 0 Pin # Single Outputs Dual Outputs 1 2 3 4 5 6 AC Line AC Neutral + Output GND GND + Output AC Line AC Neutral + Output 2 GND GND + Output 1 ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASL40 4 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies series MECHANICAL DIMENSIONS with Molex Connectors (“A” Versions single outputs only) 1.165 29.60 Input Connector: Molex 09-50-3031 Input Mating Connector: JST VHR-3N or Molex 51144 Series Output Connector: Molex 09-50-3041 Output Mating Connector: JST VHR-4N or Molex 53520 & 53521 Series Use with JST # SVH-21T-P1.1 or Molex # 50539-8100 Crimp Terminals 4 .0 0 0 1 0 1 .6 0 0.150 3.80 1.701 43.20 2.000 50.80 All 4 corner holes need to be bonded accordingly to the end product PE (Protective Earth) path. 3 .7 0 1 94 0 .1 5 0 3 .8 0 4 X O 3 .1 7 ( O 0 .1 2 5 ) 3 4 5 6 L 1 N 2 WWW.ASTRODYNE.COM Pin # Single Outputs 1 2 3 4 5 6 AC Line AC Neutral + Output + Output GND GND ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458