IEC Contactors & Starters Freedom 34-313 March 2008 Accessories Auxiliary Contacts Contact Configuration Code NEMA Sizes 00 – 2 — IEC Sizes A – K The auxiliary contacts listed below are designed for installation on Freedom Series starters and contactors. Snap-on design facilitates quick, easy installation. These bifurcated design contact blocks, featuring silver cadmium alloy contacts, are well suited for use in very low energy (logic level) circuits. This two-digit code is found on the auxiliary contact to assist in identifying the specific contact configuration. The first digit indicates the quantity of NO contacts and the second indicates the quantity of NC contacts. NEMA Sizes 3 – 8 — IEC Sizes L – Z Table 34-398. Product Selection Circuit Contact Configuration Code Catalog Number Price U.S. $ Base Auxiliary Contacts — NEMA Sizes 3 – 5, IEC Sizes L – S NO NO-NC 10 11 NEMA Size 3 IEC Sizes L – N NEMA Sizes 4 – 5 IEC Sizes P – S C320KGS31 C320KGS32 C320KGS41 C320KGS42 Auxiliary Contacts — NEMA Sizes 3 – 5, IEC Sizes L – S Catalog Number Side Mounted NO NC NO-NC Top Mounted C320KGS20 C320KGS21 C320KGS22 Auxiliary Contacts — NEMA Sizes 6 – 8, IEC Sizes T – Z Table 34-397. Selection Product Contact Configuration Code Catalog Number 1NO 1NO (Logic Level) 1NC 10 10 01 C320KGS1 C320KGS1L C320KGS2 1NO-1NC 1NO-1NC (Logic Level) 2NO 2NO (Logic Level) 2NC 1NO-1NCI 1NO (EC)-1NC (LO) 1NCI 11 11 20 20 02 N/A N/A N/A C320KGS3 C320KGS3L C320KGS4 C320KGS4L C320KGS5 C320KGS6 C320KGS7 C320KGS8 1NO 1NC 10 01 C320KGT1 C320KGT2 1NO-1NC 1NO-1NC (Logic Level) 2NO 2NC 1NO-1NCI 1NO (EC)-1NC (LO) 1NCI 11 11 20 02 N/A N/A N/A C320KGT3 C320KGT3L C320KGT4 C320KGT5 C320KGT6 C320KGT7 C320KGT8 3NO 2NO-1NC 1NO-2NC 3NC 4NO 30 21 12 03 40 C320KGT9 C320KGT10 C320KGT11 C320KGT12 C320KGT13 3NO-1NC 2NO-2NC 2NO-2NC (Logic Level) 1NO-3NC 4NC 3NO-1NCI 31 22 22 13 04 N/A C320KGT14 C320KGT15 C320KGT15L C320KGT16 C320KGT17 C320KGT18 2NO-1NCI-1NC 2NO-1NO (EC)-1NC (LO) 1NO-1NC-1NO (EC)-1NC (LO) N/A N/A N/A C320KGT19 C320KGT20 C320KGT21 Description 10 01 11 Price U.S. $ Side Mounted NO-NC 11 2NO-2NC 22 2NO-2NC 22 Size Catalog Number NEMA 8, IEC Z NEMA 6 – 7 IEC T – X C320KA5 C320KA6 C320KA8 For reference only — not part of Catalog Number. See above. NO-NC occupies two positions — L2 and L3, or R2 and R3. See next page. Top Mounted Base Auxiliary Contact Cat. No. C320KGS42 Auxiliary Contact Cat. No. C320KGS22 Note: NCI = Normally Closed early opening designed for use in reversing applications. EC = Early Closing. LO = Late Opening. For reference only — not part of Catalog Number. See above right. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com 34 IEC Contactors & Starters Freedom 34-314 March 2008 Accessories Auxiliary Contact Location NEMA Sizes 3 – 8, IEC Sizes L – Z NEMA Sizes 00 – 2, IEC Sizes A – K The sketches below illustrate the maximum number of auxiliary contacts that can be assembled to a contactor and their locations. The sketches below illustrate the maximum number of auxiliary contacts that can be assembled to a contactor or starter and their locations. Table 34-399. Auxiliary Contacts Catalog Number Size AE16 A–K AN16 Poles Available Mounting Positions Enclosed 3 T1, L1 L1 00 0–2 3 3 T1, L1, R1 T1, L1 L1 L1 AE56 A–K 3 L1, R1 L1, R1 AN56 00 – 2 3 T1, T2 — CE15 A–C D–K G–J G–J 2–4 3 4 5 T1, L1, R1 T1, L1 T1, R1 T1 L1, R1 L1 — — CN15 00 0–2 1, 2 1, 2 2–4 2–3 4 5 T1, L1, R1 T1, L1 T1, L1 T1, L1 L1 L1 — — 10A 20 – 60A 60A 60A 2–4 2–3 4 5 T1, L1, R1 T1, L1 T1, L1 T1, L1 L1 L1 — — CE55 A–K 3 L1, R1 L1, R1 CN55 00 – 2 3 T1, T2 — CN35 Table 34-400. Auxiliary Contacts Size Available Mounting Positions NEMA Size 3, IEC Sizes L – N R2, R3, L1, L2, L3 NEMA Sizes 4 – 5, IEC Sizes P – S L2, L3, R1, R2, R3 NEMA Sizes 6 – 7, IEC Sizes T – X R1 NEMA Size 8, IEC Size Z L2, R2 Available positions on contactors or starters other than what is factory installed. L1 L2 L3 R3 Base Aux. Aux. Aux. Cont. Cont. Cont. R2 R1 Aux. Aux. Base Cont. Cont. Aux. Cont. Front of Contactor Left Side of Contactor Rear Open Type Rear 34 Note: A Base Auxiliary Contact must be added in position R1 before additional auxiliary contacts can be mounted on NEMA Size 3 and IEC Sizes L – N, or in L1 on NEMA Sizes 4 – 5 and IEC Sizes P – S. Right Side of Contactor NEMA Sizes 3 – 5 IEC Sizes L – S Available positions on contactors or starters other than what is factory installed. When a pneumatic timer is mounted on contactor, only side mounted auxiliary contact positions are available. The solid-state timer, when added, takes up side mounted auxiliary contact position. L1 L1 R1 L1 T1 T1 T2 Top View Top View L1 NEMA Sizes 6 – 7 IEC Sizes T, U, V, W and X R1 T1 R1 L1 R1 T1 T2 L1 R1 L2 R2 R1 NEMA Size 8 IEC Size Z Front View Front View Non-reversing Contactors and Starters Reversing Contactors and Starters Figure 34-172. Auxiliary Contact Location Figure 34-171. Auxiliary Contact Location For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters Freedom 34-315 March 2008 Accessories DC Magnet Coils Non-reversing Kit Consists of: ■ 1 Encapsulated DC magnet coil ■ 1 NCI or NO/NCI side mounted auxiliary contact When Ordering Specify Conversion Kit for Field Assembly ■ Catalog Number Note: These kits are supplied with a NO/ NCI side mounted auxiliary contact in place of the NCI contact. Factory Installed DC Coil ■ For factory installed DC magnet coil on AC contactors or non-combination starters (open type only), substitute the Code Suffix from table below for the magnet coil identifier in the device Catalog Number. EXAMPLE: For Size 0 AC contactor with a 24V DC coil, change CN15BN3AC to CN15BN3T1C. ■ 2 Blue colored connection wires ■ 1 Instruction publication Operation These DC coil kits have separate pickup and seal windings. A special (side mounted) early-break NCI auxiliary contact is used to either disconnect the pick-up winding or insert the seal winding in series with the pick-up winding, depending on the frame size of the contactor. DC coil kits come in two styles, a suffix 1 and a suffix 4. The 1 suffix contains only the special (side mounted) early break NCI auxiliary contact. The 4 suffix contains a NO contact in the same package as the special (side mounted) early-break NCI auxiliary contact. Application ■ Connect for separate control Not for use with cover control switch operators ■ Use twin break, heavy-duty pilot devices ■ Designed for +10%, -20% rated voltage, continuous duty operation ■ Note: For NEMA Sizes 00 and 0 and IEC Sizes A – F, contactors may utilize either suffix 1 or 4 DC coil kits; starters may utilize suffix 4 DC coil kits only. For NEMA Sizes 1 and 2 and IEC Sizes G – K, both contactors and starters may utilize a suffix 4 DC coil kit only. On the above sizes only, when the special auxiliary package is mounted on the side of a contactor or starter, no standard auxiliary contact may be mounted on the same side. Note: For NEMA Sizes 3 – 5 and IEC Sizes L – S, the special coil NCI clearing contact is an add-on auxiliary (must mount on a base mount auxiliary contact; normally a 1NO). This arrangement will normally account for two of the three contact positions on the side of each contactor or starter. Table 34-401. Product Selection DC Magnet Coils Contactor or Starter Size NEMA Conversion Data Volts IEC Complete Conversion Kit Magnet Coil Coil Number Amps P.U./Seal Watts P.U./Seal NCI Interlock Number Catalog Number Price U.S $ Factory Installed Ship Wt. Code Lbs. (kg) Suffix Adder U.S $ Non-reversing — Kit includes NCI Side Mounted Auxiliary Contact 00 and 0 CN35 – A, B, D D15 Relays A–F 12 24 48 120 9-2988-11 9-2988-12 9-2988-13 9-2988-14 6.4/.28 3.2/.14 1.6/.07 .64/.028 76.8/3.36 76.8/3.36 76.8/3.36 76.8/3.36 C320KGD1 C320KGD1 C320KGD1 C320KGD1 C335KD3R1 C335KD3T1 C335KD3W1 C335KD3A1 1.0 (.5) R1 T1 W1 A1 A–F 12 24 48 120 9-2988-11 9-2988-12 9-2988-13 9-2988-14 6.4/.28 3.2/.14 1.6/.07 .64/.028 76.8/3.36 76.8/3.36 76.8/3.36 76.8/3.36 C320KGD2 C320KGD2 C320KGD2 C320KGD2 C335KD3R4 C335KD3T4 C335KD3W4 C335KD3A4 1.0 (.5) R4 T4 W4 A4 1 and 2 CN35 – G G–K 12 24 48 120 9-2990-1 9-2990-2 9-2990-3 9-2990-4 15.4/.42 7.7/.21 3.9/.11 1.5/.041 185/4.98 185/4.96 185/5.04 185/4.87 C320KGD5 C320KGD5 C320KGD5 C320KGD5 C335KD4R4 C335KD4T4 C335KD4W4 C335KD4A4 1.0 (.5) R4 T4 W4 A4 3 CN35 – K L–N 12 24 48 120 9-3002-1 9-3002-2 9-3002-3 9-3002-4 24/.40 12/.20 6.1/.097 2.5/.038 293/4.84 288/4.75 295/4.67 298/4.57 C320KGD3 C320KGD3 C320KGD3 C320KGD3 C335KD5R1 C335KD5T1 C335KD5W1 C335KD5A1 2.0 (.9) R1 T1 W1 A1 4 and 5 CN35 – N, S P–S 24 48 120 240 9-2026-4 9-2026-3 9-2026-2 9-2026-1 18/.22 9/.11 3.3/.05 1.7/.02 400/5.3 400/5.2 450/5.4 440/4.9 C320KGD3 C320KGD3 C320KGD3 C320KGD3 C335KA3T1 C335KA3W1 C335KA3A1 C335KA3B1 2.5 (1.1) T1B W1B A1B B1B 00 and 0 CN35 – A, B, D D15 Relays A–F 12 24 48 120 9-2988-1 9-2988-2 9-2988-3 9-2988-4 C320KGD1 C320KGD1 C320KGD1 C320KGD1 C335KD3R1 C335KD3T1 C335KD3W1 C335KD3A1 1.0 (0.9) R1 T1 W1 A1 1 and 2 CN35 – G G–K 12 24 48 120 9-2990-1 9-2990-2 9-2990-3 9-2990-4 C320KGD3 C320KGD3 C320KGD3 C320KGD3 00 and 0 CN35 – A, B, D D15 Relays Reversing 6.4/.28 3.2/.14 1.6/.07 .64/.028 15.4/.42 7.7/.21 3.9/.11 1.5/.041 76.8/3.36 76.8/3.36 76.8/3.36 76.8/3.36 185/4.98 185/4.96 185/5.04 185/4.87 R1 T1 W1 A1 These kits are supplied with a NO/NCI side mounted auxiliary contact in place of the NCI contact. Kit does not include mechanical interlock or crossover wiring. Two NO/NCI top mounted auxiliary contacts are supplied for electrical interlocking. Factory installed DC coils on NEMA contactors and starters include a NO/NC top mounted auxiliary contact on each contactor for electrical interlocking. On IEC contactors and starters, a NC top mounted auxiliary contact is supplied on each contactor for electrical interlocking. Available factory assembled only. Two required per reversing assembly. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com 34 IEC Contactors & Starters Freedom 34-316 March 2008 Accessories Remote Reset Module (32A Overload Relay) 34 Table 34-404. Metal Mounting Plates — Approximate Dimensions and Shipping Weights The C316RR remote reset module for the C316F, C316S and C316U overload relays allows remote resetting of tripped (32A) overload relays by means of an electrical solenoid attachment which mounts on the side of the overload relay. Table 34-402. Product Selection Remote Reset Module Operating Voltage Catalog Number 24V 50/60 Hz 110V 50/60 Hz C316RR1U C316RR1A Price U.S. $ Catalog Number Dimensions in Inches (mm) C321MP1 C321MP2 C321MP3 C321MP4 C321MP5 2.00 (50.8) 2.56 (65.0) 1.80 (45.7) 2.56 (65.0) 1.77 (45.0) 3.88 (98.6) 5.05 (128.3) 6.60 (167.6) 8.08 (205.2) 4.63 (117.6) 1.50 x 3.38 (38.1 x 85.9) 2.00 x 4.50 (50.8 x 114.3) 6.07 (154.2) 2.00 x 7.63 (50.8 x 193.8) 4.27 (108.5) .2 (.1) .4 (.2) .7 (.3) .6 (.3) .3 (.1) C321MP6 C321MP7 C321MP8 C321MP9 2.52 (64.0) 4.20 (106.7) 4.20 (106.7) 5.66 (143.8) 5.14 (130.6) 7.38 (187.5) 4.35 (110.5) 5.05 (128.3) 2.00 x 4.59 (50.8 x 116.6) 3.50 x 6.87 (88.9 x 174.5) 3.50 x 3.86 (88.9 x 98.0) 5.25 x 3.63 (133.4 x 92.2) .4 (.2) .8 (.4) .5 (.2) .8 (.4) C321MP11 C321MP12 C321MP13 8.70 (221.0) 5.71 (145.0) 8.70 (221.0) 11.35 (288.3) 8.08 (205.2) 7.17 (182.1) Metal Mounting Plates Wide High Mounting 7.00 x 10.81 (177.8 x 274.6) 5.25 x 6.75 (133.4 x 171.5) 7.00 x 6.63 (177.8 x 168.4) Ship Wt. Lbs. (kg) 1.2 (.5) .9 (.4) .9 (.4) 2-hole mounting. 3-hole mounting. 3-Pole Top Mounted Fuse Block Kit IEC Sizes A – K, NEMA Sizes 00 – 2 Field mount to Freedom Series starters and contactors. Designed to save space and reduce installation costs. They provide short circuit protection for branch circuits. Table 34-403. For Use on IEC Style Contactors, Starters and Overload Relays Application Catalog Number Contactors IEC Sizes A – F IEC Sizes G – K C321MP1 C321MP2 Non-reversing Starters IEC Sizes A – F IEC Sizes G – K C321MP3 C321MP4 Overload Relays 32A 75A C321MP5 C321MP6 Reversing Starters IEC Sizes A – F IEC Sizes G – K IEC Sizes L – N C321MP7 C321MP12 C321MP11 Reversing Contactors IEC Sizes A – F IEC Sizes G – K IEC Sizes L – N C321MP8 C321MP9 C321MP13 Price U.S. $ Table 34-405. Selection Product Fuse Type Catalog Number Class H Class R — — 30A 250V 30A 250V C350KH21 C350KR21 Class G Class G Class G Class G — — — — 15A 300V 20A 300V 30A 300V 60A 300V C350KG37 C350KG38 C350KG31 C350KG32 Class T Class T — — 30A 300V 60A 300V C350KT31 C350KT32 Class J Class J Type M Class CC — — — — 30A 600V 60A 600V 30A 600V 30A 600V C350KJ61 C350KJ62 C350KM61 C350KC63 Class T Class T — — 30A 600V 60A 600V C350KT61 C350KT62 Price U.S. $ Type M fuse block not approved for branch circuit protection. For use with DIN rail and base mounting adapters listed on Page 34-309. Discount Symbol (Remote Reset). . . . . . . . . 1CD7 Discount Symbol (Mounting Plates) . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters Freedom 34-317 March 2008 Accessories Mechanical Interlock and Reversing Kits Solid-State Timers Mechanical interlocks and reversing kits are designed for field assembly of reversing contactors or starters from Freedom Series components. The Reversing Kits include a Mechanical Interlock, stabilizer bar and a pre-cut, trimmed and formed wire set. Auxiliary contacts, if required, must be ordered separately. See Page 34-313. Solid-State ON DELAY Timer — Side Mounted on Freedom Series NEMA 00 – 2, IEC A – K and C25D, C25E and C25F Frame This timer is designed to be wired in SERIES with the load (typically a coil). When the START button is pushed (power applied to timer), the ON DELAY timing function starts. At the completion of the set timing period, timer and series wired load will both be energized. Table 34-408. Product Selection — Mounted Timer Cat. No. C321KM60B Part No. 23-7165 Wire Set Table 34-406. Reversing Kits (Horizontal Contactor Mounting Only) NEMA Size Application IEC Size Catalog Number 00 0 1 2 3 A–C D–F — G–K — C321KM60K14B C321KM60K13B C321KM60K15B C321KM60K16B C321KM60K17 — — 4 5 — L and M N — — P–S C321KM60K21 C321KM60K18 C321KM60K19 C321KM60K20 C321KM60K44 Price U.S. $ Timing Range Catalog Number .1 – 1.0 Seconds 1 – 30 Seconds 30 – 300 Seconds 5 – 30 Minutes C320TDN1_ C320TDN30_ C320TDN300_ C320TDN2000_ Add operating voltage Suffix to Catalog Number. A = 120V, B = 240V, E = 208V Rated .5 ampere pilot duty – not to be used on larger contactors. Terminal connections are quick connects only. Two per side. Shorting Bar Kits These kits provide phase-to-phase power connections of contactors for field assembly. The kits include bus connections and mounting hardware. The shorting bars connect all three phases of a single contactor. Table 34-409. Product Selection Description Catalog Number NEMA Size 3, IEC Sizes L – N NEMA Size 4, IEC Sizes P – S NEMA Size 5 NEMA Size 6, IEC Sizes T and U C321SB18 C321SB19 C321SB21 C321SB22 Kit includes (2) NC auxiliary contacts. Table 34-407. Mechanical Interlock Only Application Catalog Number Price U.S. $ NEMA Size IEC Size Contactor Mounting 00 – 2 A–K Horizontal C321KM60B 3 L–N Horizontal C321KM30 Price U.S. $ Price U.S. $ Pneumatic Timers — Top Mounted 3 to 4 N to P Horizontal C321KM43 4 P–S Horizontal C321KM40 4 to 5 — Horizontal C321KM45 4 to 6 S to T/U Horizontal C321KM80 5 — Horizontal C321KM50 Attachment mounts on top of any NEMA Size 00 – 2 or IEC Size A – K Freedom Series starter or contactor (top mounted auxiliary contacts can not be installed on device when timer is used). Timer unit has 1NO-1NC isolated timed contacts — circuits in each pole must be the same polarity. Units are convertible from OFF to ON DELAY or vice-versa. 5 to 6 — Horizontal C321KM56 Table 34-410. Maximum Ampere Ratings 6 T and U Horizontal C321KM70 6 to 7 T/U to V – X Horizontal C321KM90 7 V, W and X Horizontal C321KM34 4 or 5 to 5 P – S to 5 Vertical C321KM55 5 to 6 — Vertical C321KM65 6 T and U Vertical C321KM66 6 to 7 T/U to V – X Vertical C321KM67 Without cross-wiring. For use with latest series product. Description Make Break Volts AC 120 240 480 600 30 3 15 1.5 7.5 .75 6 .6 Table 34-411. Product Selection Timing Range Catalog Number .1 to 30 Seconds 10 to 180 Seconds C320TP1 C320TP2 Price U.S. $ Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com 34 IEC Contactors & Starters Freedom 34-318 March 2008 Accessories Locking Cover for Overload Relay — C306 Only Transient Suppressor Kits Snap-on transparent or opaque plastic panel for covering access port to the overload relay trip setting dial — helps prevent accidental or unauthorized changes to trip and reset setting. NEMA Sizes 00 – 2, IEC Sizes A – K Table 34-412. Product Selection Description Min. Ordering Catalog Qty. (Std. Pkg.) Number 34 Clear cover, no accessibility 50 C320PC3 Gray cover, no accessibility, with Auto only nib 50 C320PC4 Gray cover, no accessibility, with Manual only nib 50 C320PC5 Gray cover with FLA dial accessibility, A, B, C, D positions an Auto only nib 50 C320PC6 Gray cover with FLA dial accessibility, A, B, C, D positions and Manual only nib 50 C320PC7 Price U.S. $ Cat. No. C320TS2 These devices mount directly to the coil terminals of Freedom Series contactors or starters NEMA Sizes 00 – 2, IEC Sizes A – K and lighting contactors 10 – 60A. Reversing devices will require two. Control Circuit Fuse Block Finger Protection Shields These panel mounted fuse holders, designed for control circuit protection or other similar low current requirements, have extractor type fuse caps. The Class CC rejection type fuses (KTK-R) used in these holders are intended for use with equipment designated as being suitable for use on systems having high available fault currents. If branch circuit protective device is 45A or greater, C320FBR fuse kit may be required for control circuit protection per NEC 430-72. Snap-on shields for both contactors and starters provide IEC Type IP20 Finger Protection. Prevents accidental contact with line/load terminals. Table 34-413. Product Selection Type Max. Amperes Catalog Number Fuse Holder Only 15 30 C320FB C320FBR Price U.S. $ A fuse is not supplied, but holder will accept a Bussman Type KTK or KTK-R (13/32" x 1-1/2") fuse, 600V maximum. Includes a 5A, 600V KTK-R fuse. DIN Rail Mounting Channel — 35 mm Designed for DIN rail mounting of IEC style contactors and starters. Table 34-415. Product Selection Application Catalog Number NEMA Size 00, IEC Sizes A – C NEMA Size 0, IEC Sizes D – F C320LS1 Price U.S. $ C320LS3 C320LS4 NEMA Size 1 Starters Reversing Starters C320LS5 C320LS6 NEMA Size 2, IEC Sizes G – K Starters Reversing Starters C320LS7 C320LS8 Table 34-417. Product Selection Description Coil Voltage 50/60 Hz Catalog Number Transient Suppressor 24 – 120V 208 – 240V 277 – 480V C320TS1 C320TS2 C320TS3 Price U.S. $ Suppressor is compatible with coil voltages/ ranges as shown, 50 and 60 Hz. NEMA Sizes 3 – 5, IEC Sizes L – S C320LS2 NEMA Sizes 1 – 2, IEC Sizes G – K Contactors Reversing Contactors These kits limit high voltage transients produced in the control circuit when power is removed from the contactor or starter coil. There are three separate suppressors for use on 24 – 120V, 208 – 240V or 277 – 480V coils respectively. This device mounts on top of any side mounted auxiliary contact on Freedom Series NEMA Sizes 3 – 5, IEC Sizes L – S and lighting contactors 100 – 300A. It connects across coil terminals on any 120V contactor or starter magnet coil (reversing starters or contactors require 2). Adapter to DIN Rail Mount Limits high voltage transients produced in the circuit when power is removed from the coil. NEMA 1 – 2 and IEC G – K Contactors Table 34-418. Product Selection Designed to allow DIN rail mounting of NEMA 1 – 2 and IEC G – K contactors. Includes all hardware required to convert contactors from panel mounting to 35 mm DIN rail mounting. Description Coil Voltage Catalog Number Transient Suppressor 120V C320AS1 Price U.S. $ Table 34-416. Product Selection Catalog Number Price U.S. $ C320DN65 DIN Rail Table 34-414. Product Selection Description Catalog Number 1 Meter Length MC382MA1 Price U.S. $ Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters Freedom 34-319 March 2008 Accessories DC/AC Interface Module Adhesive Dust Cover The Catalog Number C320DC Interface Module is an optically isolated solid-state switch which provides a means of operating AC coils with a 5 – 48V DC control signal. It Cat. No. acts as a space saving C320DC interposing relay which can switch a specified 50/60 Hz AC source to the contactor or starter coil. NEMA Sizes 00 – 2, IEC Sizes A – K The module may be directly attached to the coil terminals of any Freedom Series contactor or starter — NEMA Sizes 00 – 3, IEC Sizes A – N and lighting contactors 10 – 100A. It also has provisions for DIN rail mounting. This device mounts on the side of Freedom NEMA Size 00 – 2 and IEC Size A – K contactors. One unit can be mounted on each side and carries UL, cUL and IEC ratings. The device is rated for resistive, inductive and lighting applications. The module will operate coils within the voltage ranges shown below. These adhesive stickers come 25 to a package and provide extra protection from contaminants when applied to the sides of Freedom NEMA Sizes 00 – 2 and IEC Sizes A – K. Adhesive covers are easily applied to side opening where auxiliaries are not installed DC Input: 5 – 48V DC ±10% at mA nominal ■ AC Operating Voltage: 240V AC max. (360 VA) ±10% 50/60 Hz ■ DC Operating Voltage: 30V DC max. (5A) ■ AC Current Rating: ❑ 10A make (inrush) ❑ 1A break (sealed) Table 34-421. Product Selection Description Catalog Number 25 to a package C320DSTCVR Price U.S. $ Add-On Power Pole Kit NEMA Sizes 00 – 2, IEC A – K Table 34-422. Product Selection — Add-On Power Pole Kit UL Ampere Rating Locked Lighting AC-1 Rotor Ballast 600V Tungsten 115V 230V 240V 480V IEC 947 Ampere Rating AC-3 600V AC-5a AC-5b 480V 1NO Power Pole Catalog Number 1/2 12 18 C320PPD10 Inductive Resistive hp 600V 600V 1-Phase Design Characteristics ■ and provide extra protection from metal filings and other debris. 15 20 2 96 20 20 Price U.S. $ Table 34-419. Controller Coil Voltage Ranges Controller Catalog Number Prefix Controller Coil Size or Range Rating Volts AC AE16, AE17, AE56, AE57, CE15, CE55 A–F G–K L–N 24 – 240 48 – 240 110 – 240 AN16, AN56, CN15, CN55 00 – 0 1–2 3 24 _ 240 48 – 240 110 – 240 CN35 10 – 30A 60A 100A 24 – 240 48 – 240 110 – 240 Table 34-420. Product Selection Coil Voltage Catalog Number 6V DC 9V DC C320DC2V6 C320DC2V9 12V DC 24V DC 48V DC C320DC2V12 C320DC2V24 C320DC2V48 Price U.S. $ Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com 34