MPU-120S Series Single Output, 180W Compact, U-Channel AC/DC Power Supplies Electrical Specifications Key Features: • 180W Output Power • Universal 90-264 AC Input • Power Factor Correction Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range • EN 60950 Approved Input Frequency Input Current • Compact U-Channel Inrush Current • Five Single Output Models • Meets EN 55022 B • “Finger Safe” Cover Avail. • DIN Rail Kit Available Min. Typ. 90 120 47 See Model Selection Guide Cold Start, 115 VAC Cold Start, 230 VAC 115 VAC 0.99 230 VAC 0.95 Universal Power Factor Correction, See Note 1 Safety Ground Leakage Current Max. 264 370 63 Units VAC VDC Hz 30.0 60.0 A Pk W/VA 0.50 mA Conditions Min. Typ. See Model Selection Guide ±2.0 VIN = Min to Max ±1.0 IOUT = 5% to 100% ±1.0 See Model Selection Guide 115 VAC 15 ±0.03 >125% VOUT (Autorecovery) See Note 3 130 Continuous (Autorecovery) Max. Units 180 %IOUT Conditions Max. Units VAC VDC Output Parameter Output Voltage/Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz), See Note 2 Hold-Up Time Temperature Coefficient Over Voltage Protection Overload Protection Short Circuit Protection % % % mSec %/°C General Parameter Input to Output Isolation Voltage Input to Ground Output to Ground Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions Noise Immunity (EMS) Min. 4,000 5,656 2,000 500 Typ. VAC 65 Standard kHz Criteria Level B B EN 55022 EN 55022 EN 55024 Surge EN 61000-4-4 ±1 kV (L-N) ±2 kV (L-FG & N-FG) Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Size Weight Conditions Min. Typ. Max. -25 +25 +70 -25 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % See Mechanical Drawings (Pages 3 & 4) U-Channel 13.47 Oz (0.382 kg) With Cover 14.10 Oz (0.400 kg) Reliability Specifications Parameter MTBF Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 120 kHours UL 1950, EN 60950 (except 5 & 15 VOUT models) 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Input Model Number Output Current (A) 115 VAC 230 VAC Voltage Current (A) (VDC) W/0 CFM W/30 CFM W/18 CFM % Min. Max Output Power Voltage Adjust Range Max Max Ripple & Capacitive Noise Load (W) (VDC) (mV P-P) Efficiency (%, Typ) (µF) MPU-120S-05YZ 2.0 1.0 5.0 24.0 30.0 --- 5.00 150 4.7 - 5.3 100 100,000 87 MPU-120S-12YZ 2.0 1.0 12.0 10.0 --- 15.0 1.00 180 11.4 - 13.2 50 40,000 90 MPU-120S-15YZ 2.0 1.0 15.0 8.0 --- 12.0 1.00 180 13.5 - 16.0 50 35,000 90 MPU-120S-24YZ 2.0 1.0 24.0 5.0 --- 7.5 1.00 180 22.8 - 26.4 100 20,000 93 MPU-120S-48YZ 2.0 1.0 48.0 2.5 --- 3.75 1.00 180 45.6 - 52.0 200 1,200 93 Load vs Input Voltage For open frame models, see MPO-120S Datasheet Notes: 1. PFC meets EN61000-3-2. 2. Ripple and noise is measured at 20 MHz bandwidth using a 0.1 µF and a 47 µF capacitor connected in parallel as close to the power supply terminals as possible. 3. Overload protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. These units will operate at no load without damage. However they may not meet all specifications. The recommended minimum load is given in the model selection chart above. 5. Each unit includes an input fuse. Since this fuse is not field replaceable, it is recommended that an external fuse be used on the input of the power supply for protection. For these units, a 15A/250V slow blow fuse is recommended. Model Number Temperature Derating: MPU-120S-05 Temperature Derating: All Other Models Block Diagram Page 2 • MPD 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] Mechanical Dimensions: 5V Output Model www.micropowerdirect.com Connections Input Connector (CN1): • Barrier Strip Terminal Block: Anytek Connector: DG28S-B-03P: M3 Screws 3 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Term. Function 1 2 3 AC-Line AC-Neutral Field Grnd Output Connectors: • Two PCB Terminals (Wire Lugs): PCB-50 (M5 Screws) Suitable Wire = 22 - 14 AWG Term. Function 4 5 +VOUT -VOUT Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) Mechanical Dimensions: All Other Models Connections Input Connector (CN1): • Barrier Strip Terminal Block: Anytek Connector: DG28S-B-03P: M3 Screws 3 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Term. Function 1 2 3 AC-Line AC-Neutral Field Grnd Output Connector (CN2): • Barrier Strip Terminal Block: Anytek Connector: DG28S-B-04P: M3 Screws 4 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 Term. Function 4 5 6 7 +VOUT +VOUT -VOUT -VOUT • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Mechanical Dimensions: 5V Output “E” Model Connections Input Connector (CN1): • Barrier Strip Terminal Block: Anytek Connector: DG28S-B-03P: M3 Screws 3 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Term. Function 1 2 3 AC-Line AC-Neutral Field Grnd Output Connectors: • Two PCB Terminals (Wire Lugs): PCB-50 (M5 Screws) Suitable Wire = 22 - 14 AWG Term. Function 4 5 +VOUT -VOUT Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) Mechanical Dimensions: All Other “E” Models Connections Input Connector (CN1): • Barrier Strip Terminal Block: Anytek Connector: DG28S-B-03P: M3 Screws 3 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Term. Function 1 2 3 AC-Line AC-Neutral Field Grnd Output Connector (CN2): • Barrier Strip Terminal Block: Anytek Connector: DG28S-B-04P: M3 Screws 4 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) Page 4 • MPD 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • Term. Function 4 5 6 7 +VOUT +VOUT -VOUT -VOUT E-Mail: [email protected] www.micropowerdirect.com OPTIONAL CONNECTOR - “MOLEX” TYPE Input Output Connections Input Connector (CN1): • “Molex” type connector: Alex Connector: 8673W-050220 5 pins, 2 Removed Mating Connector: 8639 type or equiv. Pin Function 1 2 3 AC-Line AC-Neutral Field Grnd Output Connector (CN2): • “Molex” type connector: Alex Connector: 8673W-080020 8 pins Mating Connector: 8639 type or equiv. Pin Function Pin Function 4 5 6 7 +VOUT +VOUT +VOUT +VOUT 8 9 10 11 -VOUT -VOUT -VOUT -VOUT OPTIONAL CONNECTOR - Clamp TYPE Input Output Connections Input Connector (CN1): • Clamp type connector: Anytek Connector: TI03245 3 terminals, 7.5 mm Centers Suitable Wire = 22 - 14 AWG MicroPower Direct • Term. Function 1 2 3 AC-Line AC-Neutral Field Grnd Output Connector (CN2): • Clamp type connector: Anytek Connector: TI04245 4 terminals, 7.5 mm Centers Suitable Wire = 22 - 14 AWG 292 Page Street Ste D Stoughton, MA 02072 Term. Function 4 5 6 7 +VOUT +VOUT -VOUT -VOUT • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com OPTIONAL DIN Rail Mount: 5V Output Model DIN Rail Mounting Kit A DIN Rail Mounting kit is available from MPD, for use with MPU-120”C” models. The kit contains a mounting clip and three screws. OPTIONAL DIN Rail Mount: All Other Models The clip is attached to the bottom of the unit using the three threaded holes marked “A” on the mechanical diagrams. Screws should not be inserted over 2 mm into the threaded inserts, To order the kit, ask for part no: MPU-120S-DRK MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]