APPLICATION TOOLING 5-B ID tools and machines ID tools and machines The arrow mark indocates the press that is applicable to the applicator. ID applicator ID applicator ID applicator for discrete wires and jumper wires for 1.27mm(.050") pitch ribbon cables for discrete wires and jumper wires ID applicator for 1.27mm(.050") pitch ribbon cables H2 series HID series H2A series FP series Hand press Pneumatic press Pneumatic press Pneumatic press AP-2H AP-2 AP-2D Auto. ID machines for discrete wires BCD-M5BP Auto. ID machines for shielded wires SCD-M15B HPD-M2A HPD-M2A-HID ID applicator for discrete wires MKD-LP Versatile press applicable to various ID applicators. Specifications Specifications • Dimensions: (W x L x H)130 x 280 x 383mm (5.1" x 11.0" x 15.1") • Weight: Approx. 7kg(15 lb) Note: The difference between the HPD-M2A and the HPD-M2A-HID is the main shaft. HPD-M2A is for the H2A series applicators HPD-M2A-HID is for the HID series applicators Auto. ID machines for 2.5 mm (.098") & 2.0 mm (.079") pitch jumper wires • Dimensions: (W x L x H) 184 x 302 x 491mm (7.2" x 11.9" x 19.3") • Weight: Approx. 30kg(66 lb) • Air pressure : 490 to 690 kPa (5 to 7 kgf/sq.cm) • Strokes: 50 max./minute • Pressure output: Approx. 7.5kN (Approx. 760 kgf)when air pressure is 490 kPa (5 kgf/sq.cm) • Operation method: Air-operated foot valve • Dies: Applicator replacement Versatile press applicable to various ID applicators. Specifications Specifications • Dimensions: (W x L x H)141 x 252 x 301mm (5.6" x 9.9" x 11.9") • Weight: Approx. 16kg(35lb) • Air pressure: 490 to 690 kPa (5 to 7 kgf/sq.cm) • Strokes: 50 max./minute • Pressure output: Approx. 3.8kN (390 kgf) when air pressure is 490 kPa (5 kgf/sq.cm) • Operation method: Air-operated foot valve • Dies: Applicator replacement • Dimensions: (W x L x H)141 x 252 x 301mm (5.6" x 9.9" x 11.9") • Weight: Approx. 16kg(35lb) • Air pressure: 490 to 686 kPa (5 to 7 kgf/sq.cm) • Strokes: 50 max./minute • Applicable connectors: JST's RA, RC & RX connectors • Pressure output: Approx. 3.8kN (Approx. 390 kgf) when air pressure is 490 kPa (5 kgf/sq.cm) • Operation method: Air-operated foot valve • Dies: Applicator replacement Note: For the HR connectors, please use AP-2H press that provides bigger pressure output. RCD-M9BE Pneumatic press for 1.27mm(.050") ribbon cable connectors. Operation is easy and safe as the connector and cable can be set while the sliding applicator is drawn out of the terminating section. Pneumatic press Pneumatic press Optional: Control unit for pneumatic presses MKD-LP+AP-K2N MP-2A MP-CU Pistol tool for discrete wires and jumper wires IDB-12 <Made in Germany> The filter regulator & pressure switch help to make reliable operation even under the air condition is not stable. Light and compact. Specifications Auto. ID machines for multi-harnesses • Dimensions: (W x L x H)200 x 300 x 230mm(7.9" x 11.8" x 9.1") • Weight: Approx. 5kg(11 lb) • Power source: 100/115/220/240V AC, single-phase, 50/60 Hz • Air pressure: 490 to 686 kPa (5 to 7 kgf/sq.cm) • Accessories: Foot switch, power cord CAM-M12B Note: MKD-LP applicators are not applicable to the connectors with glass-filled nylon housings i.e. 12 to 15-circuit DD/DS connectors and 13 to 16-circuit KR connectors. Specifications 948 • Dimensions: (WXLXH)95X515X203mm (3.7"X20.3"X8.0") • Weight: Approx. 6.5kg(14lb) • Applicable press: AP-K2N • Applicable connectors: JST'S connectors for discrete wires. Simple and compact pneumatic press without electrically controlled unit. Specifications • Dimensions: (W x L x H)23 x 135 x 175mm (.9" x 5.3" x 6.9") • Weight: 270g(1lb) • Dies: Head adaptor (IDH series) replacement • Compact, light and maintenance free. No inspection or lubrication is necessary. Specifications • Dimensions: (WXLXH)180X150X250mm (7.1"X5.9"X9.8") • Weight: Approx. 10kg(22lb) • Air pressure: 490 to 690kPa (5 to 7kgf/sq.cm) • Dies: Dies-Main body integrated • Strokes: 50 max./minute 949 ID TOOLS ID TOOLS 5-B Hand press: HPD-M2A Pneumatic press: AP-2 or AP-2H Applicator H2A series Hand press: HPD-M2A Hand press: HPD-M2A-HID Applicator Applicator H2 series HID series Pneumatic press: AP-2H Electric press: AP-K2N Pitch-feeding applicator MKD-LP with die set Pneumatic press: AP-2H Electric press: AP-K2N Applicator MKD-LR with die set Pneumatic press: AP-2D Applicator FP series Pistol tool: IDB-12 Head adaptor IDH series Connector Pitch mm(in.) Series 0.8(.031) SUR 1.5(.059) – – – – – SUR H2A-SR H2-SR20ED-X – – – – – SR SSR H2A-SSR H2-SSR20ED-X – – – – – SSR ASR H2A-ASR H2-ASR20ED-X – – – – – ASR CZ H2A-CZ H2-CZ20ED-X – – – – – CZ ZR H2A-ZR H2-ZR20ED-X – MKD-LP + MKD-DS-ZR – – ZA H2A-ZA H2-ZA20ED-X – MKD-LP + MKD-DS-ZA – – H2A-KR/XR H2-KR/XR20ED-X – MKD-LP + MKD-DS-KR (Note 1) MKD - LR + MKD-LR-DS-KR – H2A-KRD H2-KRD20DD-Y – – – – – KRD H2A-KR/XR H2-KR/XR20ED-X – – – – – CK(Note4) CR H2A-CR H2-CR20ED-X – – – – – CR DR H2A-DR H2-DR20ED-X – MKD-LP + MKD-DS-DR – – IDH-DR12 DR DA H2A-DA H2-DA20ED-X – MKD-LP + MKD-DS-DA MKD - LR + MKD-LR-DS-DA – IDH-DA12 DA H2A-DD/DS H2-DD/DS20ED-X – MKD-LP + MKD-DS-DD/DS (Note 1) – – IDH-DD/DS12 H2A-NR H2-NR20ED-X – MKD-LP + MKD-DS-NR – – IDH-NR12 KRD CK (Note 4) DD DS NR 2.54(.100) 3.96(.156) IDH-ZR12 – IDH-KR12 ZR DS NR H2-NRD20DD-Y – MKD-LP + MKD-DS-NRD (Note 2) – – H2-HR20ED-X – MKD-LP + MKD-DS-HR MKD - LR + MKD-LR-DS-HR – IDH-HR12 DB H2A-DB H2-DB20ED-X – MKD-LP + MKD-DS-DB/DC MKD - LR + MKD-LR-DS-DB – IDH-DB/DC12 DB DG H2A-DG – MKD-LP + MKD-DS-DG – – – DG BR H2A-BR – MKD-LP + MKD-DS-BR BR – NRD HR – – – RA – – HID-RA/RX – – FCD-DS FP2-RA/RX – RA RC – – HID-RC – – FCD-DS FP2-RC – RC RX – – HID-RA/RX – – FCD-DS FP2-RA/RX – RX – – – – VR Ribbon cable cutter H2A-VR – H2-VR15DD-Y – – HID-FC MKD-LP + MKD-DS-VR (Note 2) – 2.0(.079) DD H2A-HR H2-BR20ED-X 1.5(.059) KR(Note3) H2A-NRD – 1.0(.039) ZA HR NRD 2.5(.098) 0.8(.031) H2-SUR30ED-X KR (Note 3) 2.0(.079) Pitch mm(in.) H2A-SUR SR 1.0(.039) Connector Series IDH-VR12 – 2.5(.098) 2.54(.100) 3.96(.156) VR Ribbon cable cutter Note 1: MKD-LP applicators are not applicable to the connectors with glassfilled nylon housings i.e. 12 to 15-circuit DD/DS connectors and 13 to 16-circuit KR connectors. Note 2: End-connection only (not through processing) Note 3: ID tools for the standard KR series connectors are not applicable to the ( )KR-4K-** connectors. For ( )KR-4K-**, use the tools for the CR series connectors. Note 4: ID tools for the standard CK series connectors are not applicable to the ( )CK-6H-** connectors. For ( )CK-6H-**, use the tools for the KR/XR series connectors. 950 951