Honeywell HIH-4020 Humidity sensor Datasheet

HIH-4010/4020/4021
Series
Humidity Sensors
DESCRIPTION
The HIH-4010 is an uncovered integrated humidity sensor, the
The HIH-40104020/4021 Series Humidity Sensors are
HIH-4020 is a covered integrated circuit humidity sensor, and
designed specifically for high volume OEM (Original Equipment
the HIH-4021 is a covered, condensation-resistant, integrated
Manufacturer) users.
circuit humidity sensor. All three products are available in two
lead space configurations.
Direct input to a controller or other device is made possible by
this sensor’s near linear voltage output. With a typical current
The RH sensor is a laser trimmed, thermoset polymer
draw of only 200 µA, the HIH-4010/4020/4021 Series is often
capacitive sensing element with on-chip integrated signal
ideally suited for low drain, battery operated systems.
conditioning.
Tight sensor interchangeability reduces or eliminates OEM
The sensing element's multilayer construction provides
production calibration costs. Individual sensor calibration data
excellent resistance to most application hazards such as
is available.
wetting, dust, dirt, oils and common environmental chemicals.
Both products are available in two lead spacing configurations,
The HIH-4010/4020/4021 Series delivers instrumentation-
as well as with or without calibration and data printouts.
quality RH (Relative Humidity) sensing performance in a
competitively priced, solderable SIP (Single In-line Package).
FEATURES
POTENTIAL APPLICATIONS
•
Molded thermoset plastic housing
•
Refrigeration equipment
•
Near linear voltage output vs %RH
•
HVAC (Heating, Ventilation and Air Conditioning)
•
Laser trimmed interchangeability
•
Low power design
•
Medical equipment
•
Enhanced accuracy
•
Drying
•
Fast response time
•
Metrology
•
Stable, low drift performance
•
Battery-powered systems
•
Chemically resistant
•
OEM assemblies
equipment
HIH-4010/4020/4021 Series
TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)
Parameter
Minimum
Typical
Maximum
Unit
Specific
Note
–
–
–
1
–
–
–
–
2
3
4
–
Interchangeability (first order curve)
–
–
–
–
0% RH to 59% RH
-5
5
% RH
–
60% RH to 100% RH
-8
8
% RH
–
Accuracy (best fit straight line)
% RH
-3.5
–
+3.5
Hysterisis
3
% RH
–
–
Repeatability
±0.5
% RH
–
–
Settling time
70
ms
–
–
Response time (1/e in slow moving air)
5
s
–
–
Stability (at 50 %RH in 1 year)
±1.2
%
RH
–
–
Stability (at 50 %RH in 1 year)
±0.5
% RH
–
–
Voltage supply
4
5.8
Vdc
–
Current supply
500
µA
–
200
st
Voltage output (1 order curve fit)
VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25 ºC
Temperature compensation
True RH = (Sensor RH)/(1.0546 – 0.00216T), T in ºC
Output voltage temp. coefficient at 50% RH, 5 V
mV/ºC
–
-4
–
–
Operating temperature
-40[-40]
See Figure 1.
85[185]
ºC[ºF]
–
Operating humidity (HIH-4010)
0
See Figure 1.
100
% RH
5
Operating humidity (HIH-4020)
0
See Figure 1.
100
% RH
5
Operating humidity (HIH-4021)
0
See Figure 1.
100
% RH
–
Storage temperature
-50[-58]
125[257]
ºC[ºF]
–
–
Storage humidity
See Figure 2.
% RH
5
Specific Notes:
General Notes:
1. For HIH-4010/20/21-003/004 catalog listings only.
• Sensor is ratiometric to supply voltage.
2. Includes testing outside of recommended operating zone.
• Extended exposure to >90% RH causes a reversible
3. Includes testing for recommended operating zone only.
shift of 3% RH.
4. Device is calibrated at 5 Vdc and 25 ºC.
• Sensor is light sensitive. For best performance, shield
5. Non-condensing environment. When liquid water falls on the
sensor from bright light.
humidity sensor die, output goes to a low rail condition
indicating no humidity.
FACTORY CALIBRATION DATA
HIH-4010/4020/4021 Sensors may be ordered with a
calibration and data printout. See Table 2 and the order guide
on the back page.
TABLE 2. EXAMPLE DATA PRINTOUT
Model
HIH-4010-003
Channel
92
Wafer
030996M
MRP
337313
Calculated values at 5 V
0.958 V
VOUT at 0% RH
3.268 V
VOUT at 75.3% RH
Linear output for 3.5% RH
accuracy at 25 °C
Zero offset
0.958 V
Slope
30.680 mV/%RH
Sensor RH
(VOUT - zero offset)/slope
(VOUT - 0.958)/0.0307
Ratiometric response for
0% RH to 100% RH
VOUT
VSUPPLY (0.1915 to 0.8130)
2
www.honeywell.com/sensing
For HIH-4010-001/002/003/004 catalog listings only.
For HIH-4020-001/002/003/004 and HIH-4021-001/002/003/
004 catalog listings only.
Humidity Sensors
FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment for HIH-4010 and HIH-4020 catalog listings only.)
Relative Humidity
FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment for HIH-4010 and HIH-4020 catalog listings only.)
Honeywell Sensing and Control
3
HIH-4010/4020/4021 Series
FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.)
4
3.5
Output Voltage (Vdc)
3
2.5
Sensor Response
Sensor Response
Best Linear Fit
2
1.5
1
0.5
0
20
40
60
80
100
Relative Humidity (%RH)
FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.)
4.5
4
3.5
Output Voltage (Vdc)
3
2.5
0C
70 C
2
1.5
1
0.5
0
0
10
20
30
40
50
60
Relative Humidity (%)
4
www.honeywell.com/sensing
70
80
90
100
Humidity Sensors
FIGURE 5. HIH-4010 MOUNTING DIMENSIONS (For reference only. mm/[in])
FIGURE 6. HIH-4020 MOUNTING DIMENSIONS (For reference only. mm/[in])
Honeywell Sensing and Control
5
HIH-4010/4020/4021 Series
FIGURE 7. HIH-4021 MOUNTING DIMENSIONS (For reference only. mm/[in])
6
www.honeywell.com/sensing
Humidity Sensors
FIGURE 8. TYPICAL APPLICATION CIRCUIT
ORDER GUIDE
Catalog
Listing
HIH-4010-001
HIH-4010-002
HIH-4010-003
HIH-4010-004
HIH-4020-001
HIH-4020-002
HIH-4020-003
HIH-4020-004
HIH-4021-001
HIH-4021-002
HIH-4021-003
HIH-4021-004
Description
Integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP
Integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP
Integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP, calibration and data printout
Integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP, calibration and data printout
Covered integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP
Covered integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP
Covered integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP, calibration and data printout
Covered integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP, calibration and data printout
Covered, filtered integrated circuit humidity sensor, 2,45 mm [0.100 in]lead pitch SIP
Covered, filtered integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP
Covered, filtered integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP, calibration and data
printout
Covered, filtered integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP, calibration and data
printout
FURTHER HUMIDITY SENSOR INFORMATION
See the following associated literature at www.honeywell.com/sensing:
• Product installation instructions
• Application sheets:
– Humidity Sensor Performance Characteristics
– Humidity Sensor Theory and Behavior
– Humidity Sensor Moisture and Psychrometrics
– Thermoset Polymer-based Capacitive Sensors
Honeywell Sensing and Control
7
WARNING
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
• Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
009020-1-EN IL50 GLO Printed in USA
January 2007
© 2007 Honeywell International Inc. All rights reserved.
Similar pages