HIH-4010/4020/4021 Series Humidity Sensors DESCRIPTION The HIH-4010 is an uncovered integrated humidity sensor, the The HIH-40104020/4021 Series Humidity Sensors are HIH-4020 is a covered integrated circuit humidity sensor, and designed specifically for high volume OEM (Original Equipment the HIH-4021 is a covered, condensation-resistant, integrated Manufacturer) users. circuit humidity sensor. All three products are available in two lead space configurations. Direct input to a controller or other device is made possible by this sensor’s near linear voltage output. With a typical current The RH sensor is a laser trimmed, thermoset polymer draw of only 200 µA, the HIH-4010/4020/4021 Series is often capacitive sensing element with on-chip integrated signal ideally suited for low drain, battery operated systems. conditioning. Tight sensor interchangeability reduces or eliminates OEM The sensing element's multilayer construction provides production calibration costs. Individual sensor calibration data excellent resistance to most application hazards such as is available. wetting, dust, dirt, oils and common environmental chemicals. Both products are available in two lead spacing configurations, The HIH-4010/4020/4021 Series delivers instrumentation- as well as with or without calibration and data printouts. quality RH (Relative Humidity) sensing performance in a competitively priced, solderable SIP (Single In-line Package). FEATURES POTENTIAL APPLICATIONS • Molded thermoset plastic housing • Refrigeration equipment • Near linear voltage output vs %RH • HVAC (Heating, Ventilation and Air Conditioning) • Laser trimmed interchangeability • Low power design • Medical equipment • Enhanced accuracy • Drying • Fast response time • Metrology • Stable, low drift performance • Battery-powered systems • Chemically resistant • OEM assemblies equipment HIH-4010/4020/4021 Series TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.) Parameter Minimum Typical Maximum Unit Specific Note – – – 1 – – – – 2 3 4 – Interchangeability (first order curve) – – – – 0% RH to 59% RH -5 5 % RH – 60% RH to 100% RH -8 8 % RH – Accuracy (best fit straight line) % RH -3.5 – +3.5 Hysterisis 3 % RH – – Repeatability ±0.5 % RH – – Settling time 70 ms – – Response time (1/e in slow moving air) 5 s – – Stability (at 50 %RH in 1 year) ±1.2 % RH – – Stability (at 50 %RH in 1 year) ±0.5 % RH – – Voltage supply 4 5.8 Vdc – Current supply 500 µA – 200 st Voltage output (1 order curve fit) VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25 ºC Temperature compensation True RH = (Sensor RH)/(1.0546 – 0.00216T), T in ºC Output voltage temp. coefficient at 50% RH, 5 V mV/ºC – -4 – – Operating temperature -40[-40] See Figure 1. 85[185] ºC[ºF] – Operating humidity (HIH-4010) 0 See Figure 1. 100 % RH 5 Operating humidity (HIH-4020) 0 See Figure 1. 100 % RH 5 Operating humidity (HIH-4021) 0 See Figure 1. 100 % RH – Storage temperature -50[-58] 125[257] ºC[ºF] – – Storage humidity See Figure 2. % RH 5 Specific Notes: General Notes: 1. For HIH-4010/20/21-003/004 catalog listings only. • Sensor is ratiometric to supply voltage. 2. Includes testing outside of recommended operating zone. • Extended exposure to >90% RH causes a reversible 3. Includes testing for recommended operating zone only. shift of 3% RH. 4. Device is calibrated at 5 Vdc and 25 ºC. • Sensor is light sensitive. For best performance, shield 5. Non-condensing environment. When liquid water falls on the sensor from bright light. humidity sensor die, output goes to a low rail condition indicating no humidity. FACTORY CALIBRATION DATA HIH-4010/4020/4021 Sensors may be ordered with a calibration and data printout. See Table 2 and the order guide on the back page. TABLE 2. EXAMPLE DATA PRINTOUT Model HIH-4010-003 Channel 92 Wafer 030996M MRP 337313 Calculated values at 5 V 0.958 V VOUT at 0% RH 3.268 V VOUT at 75.3% RH Linear output for 3.5% RH accuracy at 25 °C Zero offset 0.958 V Slope 30.680 mV/%RH Sensor RH (VOUT - zero offset)/slope (VOUT - 0.958)/0.0307 Ratiometric response for 0% RH to 100% RH VOUT VSUPPLY (0.1915 to 0.8130) 2 www.honeywell.com/sensing For HIH-4010-001/002/003/004 catalog listings only. For HIH-4020-001/002/003/004 and HIH-4021-001/002/003/ 004 catalog listings only. Humidity Sensors FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment for HIH-4010 and HIH-4020 catalog listings only.) Relative Humidity FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment for HIH-4010 and HIH-4020 catalog listings only.) Honeywell Sensing and Control 3 HIH-4010/4020/4021 Series FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.) 4 3.5 Output Voltage (Vdc) 3 2.5 Sensor Response Sensor Response Best Linear Fit 2 1.5 1 0.5 0 20 40 60 80 100 Relative Humidity (%RH) FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.) 4.5 4 3.5 Output Voltage (Vdc) 3 2.5 0C 70 C 2 1.5 1 0.5 0 0 10 20 30 40 50 60 Relative Humidity (%) 4 www.honeywell.com/sensing 70 80 90 100 Humidity Sensors FIGURE 5. HIH-4010 MOUNTING DIMENSIONS (For reference only. mm/[in]) FIGURE 6. HIH-4020 MOUNTING DIMENSIONS (For reference only. mm/[in]) Honeywell Sensing and Control 5 HIH-4010/4020/4021 Series FIGURE 7. HIH-4021 MOUNTING DIMENSIONS (For reference only. mm/[in]) 6 www.honeywell.com/sensing Humidity Sensors FIGURE 8. TYPICAL APPLICATION CIRCUIT ORDER GUIDE Catalog Listing HIH-4010-001 HIH-4010-002 HIH-4010-003 HIH-4010-004 HIH-4020-001 HIH-4020-002 HIH-4020-003 HIH-4020-004 HIH-4021-001 HIH-4021-002 HIH-4021-003 HIH-4021-004 Description Integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP Integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP Integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP, calibration and data printout Integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP, calibration and data printout Covered integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP Covered integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP Covered integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP, calibration and data printout Covered integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP, calibration and data printout Covered, filtered integrated circuit humidity sensor, 2,45 mm [0.100 in]lead pitch SIP Covered, filtered integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP Covered, filtered integrated circuit humidity sensor, 2,45 mm [0.100 in] lead pitch SIP, calibration and data printout Covered, filtered integrated circuit humidity sensor, 1.27 mm [0.050 in] lead pitch SIP, calibration and data printout FURTHER HUMIDITY SENSOR INFORMATION See the following associated literature at www.honeywell.com/sensing: • Product installation instructions • Application sheets: – Humidity Sensor Performance Characteristics – Humidity Sensor Theory and Behavior – Humidity Sensor Moisture and Psychrometrics – Thermoset Polymer-based Capacitive Sensors Honeywell Sensing and Control 7 WARNING WARNING MISUSE OF DOCUMENTATION • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: [email protected] Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com/sensing 009020-1-EN IL50 GLO Printed in USA January 2007 © 2007 Honeywell International Inc. All rights reserved.