ETC H2008B-3 Nema contactors & starters 33-79 Datasheet

NEMA Contactors & Starters
Freedom
33-79
February 2007
Catalog Number Selection
Catalog Number Selection
Table 33-91. Freedom Catalog Numbering System
A N 1 4 A N 0 A 3E 005
Device Type
C396 Electronic Overload FLA Range
(FNVR & FVR Only)
A = Starter
C = Contactor
Standard
E = IEC
N = NEMA
Device Assembly Configuration
70 = Multi-Speed
1 = Non-reversing
5 = Reversing
OLR Type
4 = Starter w/C396 Electronic Overload
5 = Contactor only — no overload relay
6 = Starter w/C306 Bi-Metal OLR
7 = Starter w/C316 Bi-Metal OLR
8 = Starter w/IT. SSOLR
A=
B=
D=
G=
K=
N=
S=
T=
U=
V=
00
0
1
2
3
4
5
6
7
8
Continuous
Amp Rating
9
18
27
45
90
135
270
540
810
1215
Frame G — NEMA Size 2
008 = 1.6 – 8.0A
032 = 6.4 – 32A
045 = 9.0 – 45A
Frame B — NEMA Size 0
P05 = 0.1 – 0.5A
002 = 0.4 – 2.0A
005 = 1.0 – 5.0A
008 = 1.6 – 8.0A
032 = 6.4 – 32A
Frame K — NEMA Size 3
110 = 22 – 110A
Frame D — NEMA Size 1
P05 = 0.1 – 0.5A
002 = 0.4 – 2.0A
005 = 1.0 – 5.0A
008 = 1.6 – 8.0A
032 = 6.4 – 32A
Frame T — NEMA Size 6 600 = 120 – 600A
Frame S — NEMA Size 5 300 = 60 – 300A
Frame U — NEMA Size 7 10C = 200 – 1000A
Frame V — NEMA Size 8 15C = 300 – 1500A
Standard C396 OLR, SEL Reset, SEL Class
C=
B=
N/R =
B=
C=
B=
NEMA Size 00, 0
NEMA Size 1, 2
NEMA Size 3, 4 NEMA Size 5
NEMA Size 6
NEMA Size 7, 8
C306 Bi-Metallic OLR Designation
N = Open
For Starters
Starter
Mounting Option
0=
V=
Horizontal
Vertical
For Contactors Only
2-pole
3-pole
4-pole
5-pole
AC Coil Suffix
Suffix
Coil Volts and Hertz
A=
B=
C=
D=
120/60 or 110/50
240/60 or 220/50
480/60 or 440/50
600/60 or 550/50
E=
H=
J=
K=
208/60
277/60
208 – 240/60 240/50
L=
N=
T=
U=
380 – 415/50
550/50
24/60, 24/50 24/50
V=
W=
Y=
32/50
48/60
48/50
For Contactor Only orders, add B to end of Catalog Number if NEMA Size 00 – 2, 6.
3E, 4E feature set only.
Uses CT with C396 45 mm OLR, 3E, 4E feature set only.
Not required.
NEMA Sizes 00 and 0 only.
NEMA Sizes 00 and 0 only. Sizes 1 – 8 are 24/60 only.
CA08102001E
Frame N — NEMA Size 4 150 = 30 – 150A
3E =
NEMA Enclosure
2=
3=
4=
5=
Frame A — NEMA Size 00
P05 = 0.1 – 0.5A
002 = 0.4 – 2.0A
005 = 1.0 – 5.0A
008 = 1.6 – 8.0A
C396 Electronic OLR Designation (FVNR & FVR Only)
Contactor Frame Size NEMA
Size
33
For more information visit: www.eaton.com
NEMA Contactors & Starters
Freedom
33-85
February 2007
Starters — 3-Phase Non-reversing and Reversing, Full Voltage, Bi-Metallic Overload
Product Selection
When Ordering Supply
■
■
Catalog Number
Heater pack number (see selection
table, Pages 33-117 – 33-118) or full load
current.
Size 0
Non-reversing
Starter
Size 3
Vertical
Reversing
Starter
Size 1
Reversing
Starter
Table 33-101. Type AN16/AN56 NEMA — Manual or Automatic Reset Overload Relay — Non-reversing and Reversing
Maximum UL Horsepower NEMA Continuous Service-Limit
Current
Size
Ampere
Rating Rating
(Amperes)
00
9
11
0
18
21
1-Phase
115V 230V 208V
1/3
1
3-Pole
Non-reversing 3-Phase
240V
480V 600V Catalog
Number
Price
U.S. $
3-Pole
Reversing Vertical
Reversing Catalog
Number
Catalog
Number
1
1-1/2
1-1/2
2
2
AN16AN0_C
AN56AN0_C
—
2
3
3
5
5
AN16BN0_C
AN56BN0_C
AN56BNV0_
AN56DNV0_
1
27
32
2
3
10
10
AN16DN0_B
AN56DN0_B
2
45
52
3
7-1/2
10
15
25
25
AN16GN0_B
AN56GN0_B
AN56GNV0_
3
90
104
—
—
25
30
50
50
AN16KN0_
AN56KN0_
AN56KNV0_
4
135
156
—
—
40
50
100
100
AN16NN0_
AN56NN0_
AN56NNV0_
5
270
311
—
—
75
100
200
200
AN16SN0_B
AN56SN0_B
—
6
540
621
—
—
150
200
400
400
AN16TN0_C
AN56TN0_C
—
7
810
932
—
—
200
300
600
600
AN16UN0_B
AN56UN0_B
—
1215
1400
—
—
400
450
900
900
AN16VN0_B
AN56VN0_B
—
8
7-1/2
7-1/2
Price
U.S. $
Note: Starter Catalog Numbers do not include heater packs. Select one carton of three heater packs. Heater pack selection, Pages 33-117 – 33-118.
Underscore (_) indicates coil suffix required, see Table 33-102.
Maximum horsepower rating of starters for 380V 50 Hz applications:
NEMA Size
00
0
1
2
3
4
5
6
7
8
Horsepower
1-1/2
5
10
25
50
75
150
300
600
900
The service-limit current ratings represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods
in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its
continuous current rating. The current rating of overload relays or trip current of other motor protective devices used shall not exceed the service-limit
current rating of the controller.
Common control. For separate 120V control, insert letter D in 7th position of listed Catalog Number. EXAMPLE: AN56VND0CB.
Magnet Coils — AC or DC
Starter coils listed in this section also
have a 50 Hz rating as shown in the
adjacent table. Select required starter
by Catalog Number and replace the
magnet coil alpha designation in the
Catalog Number (_) with the proper
Code Suffix from the adjacent table.
NEMA Size 0
Cat. No. AN56BN0AC
For Sizes 00 – 2 and 5 – 8, the magnet
coil alpha designation will be the next
to last digit of the listed Catalog Number. EXAMPLE: For a 380V, 50 Hz coil,
change AN16BN0_C to AN16BN0LC.
For all other sizes, the magnet coil
alpha designation will be the last digit
of the listed Catalog Number.
For DC Magnet Coils, see Accessories,
Pages 33-98 – 33-99.
Table 33-102. AC Suffix Code
Coil Volts and Hertz
Code Suffix
120/60 or 110/50
240/60 or 220/50
480/60 or 440/50
600/60 or 550/50
A
B
C
D
208/60
277/60
208 – 240/60 240/50
E
H
J
K
380 – 415/50
550/50
24/60, 24/50 24/50
L
N
T
U
32/50
48/60
48/50
NEMA Sizes 00 and 0 only.
NEMA Sizes 00 and 0 only. Sizes 1 – 8 are
24/60 only.
Technical Data. . . . . . . . . .
Overload Relay . . . . . . . . .
Dimensions . . . . . . . . . . . .
Special Modifications . . .
Accessories . . . . . . . . . . . .
Heater Packs . . . . . . . . . . .
Discount Symbol . . . . . . . .
CA08102001E
For more information visit: www.eaton.com
V
W
Y
Pages 33-89 – 33-91
Page 33-113
Pages 33-106 – 33-108
Page 33-100
Pages 33-92 – 33-100
Pages 33-117 – 33-118
1CD1
33
NEMA Contactors & Starters
Freedom
33-117
February 2007
Relays — Thermal Overload
Product Selection
33
75A Overload
Cat. No. C306GN3B
75A Overload
Cat. No. C306GT3B
32A Overload
Cat. No. C306DT3B
32A Overload
Cat. No. C306DN3B
Table 33-168. C306 Thermal Overload Relays
For Use with Freedom
Series Contactors
NEMA
Size
00, 0
1, 2
3
4
5–8
Maximum
Ampere
Rating
Number
of Poles
32 75 105 144 —
3
3
3
3
—
Open Type
Catalog
Number
Number
of Poles
NEMA Size
Maximum
Ampere
Rating
00, 0, 1 1
3
4
5–8
32
75
105
144
—
3
3
3
3
—
Catalog
Number
Price
U.S. $
C306DG3B
C306GG3B
—
NEMA Sizes 5 – 8 use the 32A overload in conjunction with CTs.
Series B overload relays have load lugs built into relay base and will only accept Series B heater packs. These relays can be directly attached to
contactor or they can be DIN rail or panel mounted using adapter on Page 33-115.
These relays can be panel mounted only.
For Stand-Alone
Applications
Price
U.S. $
C306DN3B
C306GN3B
C306KN3
C306NN3
—
Heater Pack Selection
Table 33-169. C306 Thermal Overload Relays
NEMA 1 Enclosed
Open Type
Catalog
Number
Price
U.S. $
C306DT3B
C306GT3B
C306KN3
C306NN3
—
Overload relay assembled with mounting adapter for DIN rail or
panel mount.
Panel mount only.
NEMA Sizes 5 – 8 use the 32A overload in conjunction with CTs.
Heater packs H2001B to H2017B and H2101B to H2117B are
to be used only with Series B overload relays Catalog
Numbers C306DN3B (Part No. 10-7016) and C306GN3B
(Part No. 10-7020). The load lugs are built into the overload
relay base to allow load wiring prior to heater pack installation. The previous heater design had integral load lugs.
The Series B heater packs are electrically equivalent to the
previous heater design. Heaters H2018-3 to H2024-3 have
not changed.
Table 33-170. Starters with Series B Overload Relays
NEMA — AN Type
IEC — AE Type
Size
Series
Size
Series
00 – 0
1–2
5
6
7–8
C
B
B
C
B
A–F
G–K
C
B
Note: The series of a starter is the last digit of the listed Catalog
Number. EXAMPLE: AN16DN0AB.
Heater Pack
H2001B – H2017B
Heater Pack
H2101B – H2117B
Heater Pack
H2018 – H2024
Technical Data . . . . . . . .
Dimensions . . . . . . . . . . . .
Replacement Parts . . . . .
Discount Symbol . . . . . . .
CA08102001E
For more information visit: www.eaton.com
Page 33-114
Page 33-116
Pages 33-115 – 33-116
1CD1C
NEMA Contactors & Starters
Freedom
33-118
February 2007
Relays — Thermal Overload
Table 33-171. Standard Trip — Class 20 Heater Selection
Overload
Relay
Size
33
Motor Full Load Ampere Rating
Catalog
Number
(Includes
3 Heater
Packs) Dial Position
A
B
C
D
Table 33-172. Fast Trip — Class 10 Heater Selection
Price
U.S. $
For Use with NEMA Sizes 00 – 0 Series C, NEMA Sizes 1 – 2 Series B;
IEC Sizes A – F Series C, IEC Sizes G – K Series B
32A or
75A
.254
.375
.560
.814
1.20
.306
.452
.676
.983
1.45
.359
.530
.791
1.15
1.71
1.79
2.15
3.23
4.55
6.75
2.16
2.60
3.90
5.50
8.17
2.53
3.04
4.56
6.45
9.58
9.14
14.0
18.7
23.5
10.8
16.9
22.7
28.5
12.4
19.9
26.7
33.5
.411
.607
.907
1.32
1.96
H2001B-3
H2002B-3
H2003B-3
H2004B-3
H2005B-3
29.0
39.6
53.9
34.0
45.5
60.9
39.1
51.5
67.9
11.5
15.7
19.0
24.5
33.4
H2025-3
H2026-3
H2027-3
H2018-3
H2019-3
33.5
45.7
62.2
84.7
106.0
37.5
51.2
69.7
95.0
118.0
41.5
56.7
77.1
105.0
131.0
45.6
62.1
84.6
115.0
144.0
H2020-3
H2021-3
H2022-3
H2023-3
H2024-3
79
118
174
209
—
H2004B-3
H2005B-3
H2006B-3
H2007B-3
H2008B-3
For Use with Size 6 Starters Only — Series B and IEC T – V with 600/5 CT
32A 144
215
258
388
174
259
312
468
205
304
365
547
235
348
419
627
H2005B-3
H2006B-3
H2007B-3
H2008B-3
75A
163
240
358
430
646
197
290
432
520
780
230
342
506
608
912
.313
.464
.688
1.02
1.55
2.33
2.79
4.10
6.03
8.58
264
392
580
698
—
11.2
17.5
21.8
27.3
.367
.543
.806
1.20
1.83
.420
.623
.924
1.37
2.10
H2101B-3
H2102B-3
H2103B-3
H2104B-3
H2105B-3
2.74
3.28
4.82
7.09
10.1
3.15
3.77
5.54
8.16
11.6
H2106B-3
H2107B-3
H2108B-3
H2109B-3
H2110B-3
12.8
20.7
25.0
31.0
14.4
23.8
28.1
34.8
H2111B-3
H2112B-3
H2113B-3
H2114B-3
H2004B-3
H2005B-3
H2006B-3
H2007B-3
H2008B-3
28.3
36.6
53.8
32.6
42.3
60.8
37.0
48.1
67.9
41.3
53.8
74.9
H2115B-3
H2116B-3
H2117B-3
For Use with Size 5 Starters Only — Series B and IEC P, R and S with 300/5 CT
32A 51
77
115
138
203
61
93
140
167
246
72
110
164
197
289
82
126
189
226
—
H2104B-3
H2105B-3
H2106B-3
H2107B-3
H2108B-3
For Use with Size 6 Starters Only — Series B and IEC T – V with 600/5 CT
32A 154
230
276
406
186
280
335
492
220
329
394
578
252
378
452
—
H2105B-3
H2106B-3
H2107B-3
H2108B-3
For Use with Size 7 Starters Only — Series B and IEC W – X with 1000/5 CT
32A 169
256
384
460
676
204
310
466
558
820
240
366
543
656
—
274
420
630
754
—
H2104B-3
H2105B-3
H2106B-3
H2107B-3
H2108B-3
For Use with Size 8 Starters Only — Series B and IEC Z with 1500/5 CT
32A For Use with Size 7 Starters Only — Series B and IEC W – X with 1000/5 CT
32A D
Price
U.S. $
For Use with NEMA Size 2, IEC Sizes G – K Only — Series B
H2015B-3
H2016B-3
H2017B-3
10.3
14.3
17.4
22.3
30.5
69
103
152
182
274
C
.260
.384
.570
.846
1.28
9.60
14.4
18.7
23.5
9.2
12.8
15.7
20.2
27.6
59
87
130
156
234
32A or
75A
H2011B-3
H2012B-3
H2013B-3
H2014B-3
44.1
57.4
74.9
Catalog
Number
(Includes
3 Heater
Packs) For Use with NEMA Sizes 00 – 0 Series C, NEMA Sizes 1 – 2 Series B;
IEC Sizes A – F Series C, IEC Sizes G – K Series B
14.0
22.8
30.7
38.5
8.0
11.4
14.3
18.0
24.6
49
72
107
129
194
B
1.92
2.30
3.38
4.96
7.07
For Use with Size 5 Starters — Series B and IEC P, R and S with 300/5 CT
32A A
H2006B-3
H2007B-3
H2008B-3
H2009B-3
H2010B-3
For Use with NEMA Sizes 3 – 4, IEC Sizes L – N Only — Series A
105A or
144A
Motor Full Load Ampere Rating
Dial Position
2.90
3.49
5.23
7.40
11.0
For Use with NEMA Size 2, IEC Sizes G – K Only — Series B
75A
Overload
Relay
Size
254
384
576
690
1014
306
465
699
837
1230
360
549
822
984
—
411
630
945
1131
—
H2104B-3
H2105B-3
H2106B-3
H2107B-3
H2108B-3
Heater packs are shipped 3 to a carton. Catalog Numbers are for
3 heater packs.
Sizes 5 – 8 and IEC P – Z use the 32A overload relay with current
transformers.
For Use with Size 8 Starters Only — Series B and IEC Z with 1500/5 CT
32A 244
360
537
645
969
295
435
648
780
1170
345
513
759
912
1368
396
588
870
1047
—
H2004B-3
H2005B-3
H2006B-3
H2007B-3
H2008B-3
Heater packs are shipped 3 to a carton. Catalog Numbers are for
3 heater packs.
Sizes 5 – 8 and IEC P – Z use the 32A overload relay with current
transformers.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
For more information visit: www.eaton.com
CA08102001E
Similar pages